QSFPTEK S7600-24X2C Quick Start Guide

Version 2.0

Introduction

The QSFPTEK S7600-24X2C L3+ aggregation switch is designed with 24x 10G SFP+ ports and 2x 40/100G QSFP28 uplinks. Each QSFP28 port can be split into 4x 10G ports or 4x 25G ports, providing converged 10G, 25G, 40G, and 100G fiber links. This 24-port switch delivers an 880 Gbps switching capacity and 540 Mpps forwarding rate to meet high-performance aggregation layer requirements. The 10GbE network switch is equipped with 2 hot-swap AC power supplies (1+1 redundancy) and 3 built-in smart fans (2+1 redundancy), providing hardware redundancy for enhanced reliability. As a layer 3+ managed switch, it supports full layer 3 features (static routing, RIP, OSPF, BGP, etc.) and advanced data center features such as MLAG for high-reliability and VXLAN, NVGRE, GENEVE tunnel technology for virtual networking. S7600 series aggregation switches support remote direct memory access (RDMA), which over other network APIs for lower latency, CPU load, and higher bandwidth. This 24-port 10Gb switch caters to the Ethernet aggregation platform to HCI (hyper-converged infrastructure), cloud networking, data center, and enterprise applications.

Accessories

Hardware Overview

Front Panel Ports

The front panel includes:

Front Panel LEDs

LEDS Status Description
ID Blue On ID indication function enable
Blue Off ID indication function disable
SYS Green On The system is normal running
Amber On The system occurs alarm or error
- Off No power or system is not run or abnormality
ETH Green On Port link.
Green Blinking Port is receiving or transmitting packets.
Green Off Port not link.
SFP+ (Port 1-24) Green On 10G port link.
Green Blinking 10G packets receiving or transmitting.
SFP+ (Port 1-24) Amber On 1G port link.
Amber Blinking 1G packets receiving or transmitting.
- Off Port not link
QSFP28 (Port 25-26) Green On 100G/40G port link.
Green Blinking 100G/40G packets receiving or transmitting.
QSFP28 (Port 25-26) Amber On 100G/40G port link.
Amber Blinking 100G/40G packets receiving or transmitting.
QSFP28 (Port 25-26) - Off Port not link

Back Panel

The back panel includes a Grounding Point, 3 Built-in Fans, and 2 Hot-swap Power Supplies.

Installation Requirements

Tools Preparation

Temperature/Humidity Requirements

Temperature Humidity
0~45°C 10%~95%

Cleanliness Requirements

Substance Unit Concentration limit
DUST Particle/m3 ≤ 3 X 104 (No visible dust on the tabletop for three days)
SO2 mg/m3 0.2
H2S mg/m3 0.006
NH3 mg/m3 0.05
CI2 mg/m3 0.01

Note: The dust particle size is ≥ 5 µm

Mounting the Switch

Connecting the Power

1. Plug the AC power cord to the switch power port on the back rear.

2. Connect the other end of the power cord to an AC power source equipment.

Connecting the SFP+ Ports

1. Insert the SFP+ module into the SFP+ port.

2. Plug a fiber patch cable into the SFP+ transceiver.

3. Connect the other end of the fiber to the device that you want to realize data communication.

Connecting the QSFP28 Port

1. Insert the QSFP28 module into the QSFP28 port.

2. Plug a fiber patch cable to the QSFP28 transceiver.

3. Connect the other end of the fiber to the device that you want to realize data communication.

Connecting the Management Ports

Connecting the Console Port

1. Prepare a console cable.

2. Insert the RJ45 connector of the console cable into the console port on the switch.

3. Connect the D89 female connector on the other end of the console cable to the serial port on the computer host.

Connecting the ETH Port

1. Prepare a standard RJ45 Ethernet patch cable.

2. Insert one end of the RJ45 Ethernet patch cable into the computer RJ45 port.

3. Connect the RJ45 connector on the other end of the patch cable to the ETH port on the switch.

Connecting the USB Port

1. Prepare a Universal Serial Bus (USB) flash disk.

2. Insert the USB to the switch USB port.

Configuring the Switch

Configuring the Switch Using the Web-based Interface

Step 1: Connect your computer to the switch using an Ethernet cable and open a web browser.

Step 2: Set the IP address of the computer to 192.168.1.x (where "x" is any number from 2 to 254) and the subnet mask to 255.255.255.0.

Step 3: Open a web browser and type http://192.168.1.1 in the address bar. Enter the default username and password (admin/admin).

Step 4: Click sign-in to access the web-based configuration page.

Configuring the Switch Using the Console Port

Step 1: Use the console cable to directly connect the switch console port to your computer.

Step 2: Launch the terminal simulation software such as Hyper Terminal on the computer.

Step 3: Configure the parameters of the terminal emulation software as follows: 115200 bits per second, 8 data bits, no parity, 1 stop bit, and no flow control.

Step 4: Enter the default username and password (admin/admin).

Troubleshooting

Loading Failure Processing

After loading fails, the system will keep running in the original version. At this time, users should refer to the following steps to re-check:

  1. If physical port connections are good first. If some ports are not connected, then re-connect them to ensure that physical connections are correct, and begin re-loading.
  2. If physical connections are correct, then check the loading process information displayed on the super terminal to verify if there are input errors. If there are input errors, correct them and re-load. For example, when using TFTP protocol, enter incorrect IP addresses of the Server and Switch, name of loading software, or do not specify the correct working path of the correct TFTP server.
  3. If physical connections are good, and there are no input errors in the loading process but the loading fails finally, please contact agents for help.

User Password Lost

If the system password is lost or forgotten, the following method can be used to reset the password:

  1. Enter uBoot operation mode; see Chapter 5 for how to enter.
  2. Input the boot_flash_nopass command to start the system in uBoot mode.

Note: After using the boot_flash_nopass command, the system will clear up the startup-config files; before starting this operation, the startup-config files will be stored in flash:/startup-config.conf.old file.

Power System Troubleshooting

The switch can judge if its power system is faulty according to the PWR indicator on the front panel: when the power system works normally, the PWR indicator shall always keep lighting; when the PWR indicator is off, please check if:

  1. The power line of the switch is connected correctly.
  2. The EPS of the switch matches the power required by the switch.

Configuration System Troubleshooting

After the switch is powered on, if the system is normal, the startup information will be displayed on the configuration terminal; If no display information on the configuration terminal appears, maybe the configuration system is faulty, please check if:

  1. The power is normal.
  2. The cable of the configuration port (Console) is properly connected.

If no problems have been found after the above checks, it is possible that the configuration cable is faulty or the parameter setting of the terminal (such as a super terminal) is incorrect, please check accordingly.

3. Troubleshooting for the terminal displaying hashes:

If the configuration terminal displays hashes, probably the parameter setting of the terminal (such as a super terminal) is incorrect. Please confirm the parameter setting of the terminal (such as HyperTerminal): baud rate: 115200, data bit: 8, parity: no, stop bit: 1, flow control: NA, selecting terminal emulation: VT100.

Support and Other Resources

Product Warranty

S7600 series switches are backed by a 5-year limited warranty supported by QSFPTEK. You are eligible to apply for a return within 14 days and exchange within 90 days of receiving them.

For more details about applying qualifications, please live chat or email sales@qsfptek.com for support.

5 Year Warranty

14-day Return Window

Models: S7600-24X2C, S7600-24X2C L3 Plus Aggregation Switch, L3 Plus Aggregation Switch, Aggregation Switch, Switch

File Info : application/pdf, 12 Pages, 643.84KB

PDF preview unavailable. Download the PDF instead.

S7600-24X2C User Guide

References

WPS 文字

Related Documents

Preview QSFPTEK S7600-48X8C Quick Start Guide
A quick start guide for the QSFPTEK S7600-48X8C L3+ aggregation switch, detailing its features, hardware overview, installation requirements, connection procedures, configuration steps, troubleshooting, and warranty information.
Preview QSFPTEK S7300-24X2C: High-Performance L3 10G Ethernet Switch
Explore the QSFPTEK S7300-24X2C, a stackable L3 10G Ethernet switch for data centers and enterprise networks. Features 24x 10GE SFP+ and 2x 100GE/40GE QSFP28 ports, BVSS stacking, advanced security, and comprehensive IPv6 support.
Preview QSFPTEK S7300-48X2Q4C 48-Port 10G Ethernet L3+ Switch Quick Start Guide
A quick start guide for the QSFPTEK S7300-48X2Q4C, a 48-port 10G Ethernet L3+ Switch with 48x 10G SFP+, 2x 40G QSFP+, and 4x 100G QSFP28 uplink ports. Includes hardware overview, installation requirements, connection guides, and troubleshooting.
Preview QSFPTEK S5300-24T6X Quick Start Guide
A quick start guide for the QSFPTEK S5300-24T6X, a 24-port Gigabit Ethernet L3 switch with 24x 1G RJ45 ports and 6x 10G SFP+ uplinks, supporting stacking.
Preview QSFPTEK S7300-48TE4X2Q Quick Start Guide - Multi-Gigabit L3 Ethernet Switch
This quick start guide provides essential information for setting up and configuring the QSFPTEK S7300-48TE4X2Q, a 48-port multi-gigabit L3 Ethernet switch. Learn about hardware features, installation, connection procedures, web-based and console configuration, and basic troubleshooting.
Preview QSFPTEK S5300-48P6X Quick Start Guide
A quick start guide for the QSFPTEK S5300-48P6X, a 48-port Gigabit Ethernet L2+ PoE+ Switch with 6x 10G SFP+ Uplinks and stacking support. Includes hardware overview, installation requirements, connection guides, and troubleshooting.
Preview QSFPTEK S5300-8TE4X-P Quick Start Guide
A quick start guide for the QSFPTEK S5300-8TE4X-P 8-Port Ethernet L2 Multi-Gigabit PoE Switch, detailing its features, hardware overview, installation, and basic configuration.
Preview QSFPTEK S5600-48S4X Quick Start Guide
A quick start guide for the QSFPTEK S5600-48S4X, a 48-port 1Gb SFP Ethernet L3+ Switch with 48x 1G SFP Ports and 4x 10G SFP+ Uplinks, supporting MLAG, VXLAN. This guide covers introduction, accessories, hardware overview, installation requirements, mounting, configuration, and troubleshooting.