Quick Installation Guide
Rechargeable Li-ion Battery System
Lynx C Series
(LX C 101-10 | LX C120-10 | LX C138-10 | LX C156-10)
V1.0-2022-10-12
01 Safety Precaution
General Disclaimer
- The information in this user manual is subject to change due to product updates or other reasons. This guide cannot replace the product labels or the safety precautions in the user manual unless otherwise specified. All descriptions in the manual are for guidance only.
- Read through the quick installation guide before installations. For additional information, please see the user manual.
- All operations should be performed by trained and knowledgeable technicians who are familiar with local standards and safety regulations.
- Check the deliverables for correct model, complete contents, and intact appearance. Contact After-sales Service for anything wrong.
- Use insulating tools and wear personal protective equipment (PPE) when operating the equipment to ensure personal safety.
- Strictly follow the installation, operation, and configuration instructions in this guide and relative user manual. The manufacturer shall not be liable for equipment damage or personal injury if you do not follow the instructions. For more warranty details, please visit https://en.goodwe.com/warranty.
Safety Disclaimer
Instructions during Installation
- Please keep Power Off before any operations to avoid danger. Strictly follow all safety precautions outlined in this manual and safety labels on the equipment.
- The Lynx C Series Rechargeable Li-ion Battery System for Commercials and Industries (hereinafter referred to as the Lynx C BS in short) is a high voltage system. Do not touch or operate it. Keep away from it. Only professionals are allowed!
- Please use appropriate tools and take protective measures when installing and maintaining heavy equipment. Improper operations will cause personal injuries.
- Do not use the battery module or Power Control Unit (PCU in short) if it is defective, broken, or damaged.
- Do not disassemble, modify, or replace any part of the battery module or PCU without official authorization from the manufacturer.
- Pay attention to the negative and positive during installation to avoid reverse polarity connection. Otherwise the short circuit may cause personal injuries and equipment damage.
Emergency Measures
Damaged battery modules may leak electrolyte. Do not contact with the liquid leakage or volatile gas. Please contact After-sales Service for help immediately.
- Inhalation: Evacuate from the contaminated area, and seek immediate medical assistance.
- Eye contact: Rinse your eyes for at least 15 minutes with clean water and seek immediate medical assistance.
- Skin contact: Thoroughly wash the touch area with soap and clean water, and seek immediate medical assistance.
- Ingestion: Induce vomiting, and seek immediate medical assistance.
02 Label Description
Symbol | Description | Symbol | Description |
[Warning] ⚠️ | Potential risks exist. Wear proper PPE before any operations. | [Flammable] ? | Keep the equipment away from open flame or ignition source. |
[High Voltage Hazard] ⚡ | High voltage exists during the equipment's running. Ensure the equipment is power off before any operations. | [Keep Away From Children] ? | Keep the equipment away from children. |
[Explosion Risk] ? | Operate the equipment properly to avoid explosion. | [No Water Extinguishing] ?? | No extinguishing with water. |
[Corrosive Electrolytes] ☣️ | The equipment contains corrosive electrolytes. In case of a leak in the equipment, avoid contact the leaked liquid or gas. | [Flammable Materials] ? | Batteries contain flammable materials. Beware of fire. |
[Read Manual] ? | Read through the user manual before any operations. | [End-of-Life Disposal] ♻️ | Do not dispose of the equipment with household garbage at its end of life. Dispose it according to local laws and regulations. Or send it to the manufacturer. |
[Proper Placement & Recycling] ♻️ | Put the battery in the right place and recycle it in compliance with local environmental regulations. | [Safety Protection] ✔️ | Pay attention to safety protection during installation, operation and maintenance. |
[No Stepping] ?? | No stepping. | [Grounding] ⏚ | Grounding. To indicate PE cable connection position. |
CE | CE Marking. | TÜV | TUV Marking. |
RCM | RCM Marking. | - | - |
Check before Power ON
No. | Check Item |
1 | The equipment is firmly installed in a clean place where is well-ventilated and easy to operate. |
2 | Ensure that PE, the battery high voltage copper bus, the inverter power cable, the communication cable and single phase AC cable are connected correctly and securely. |
3 | Cable ties are intact, routed properly and evenly. |
EU Declaration of Conformity
The Lynx C BS sold in the European market meets the following directives and requirements:
- Electromagnetic compatibility Directive 2014/30/EU (EMC)
- Electrical Apparatus Low Voltage Directive 2014/35/EU (LVD)
- Restrictions of Hazardous Substances Directive 2011/65/EU and (EU) 2015/863 (RoHS)
- Waste Electrical and Electronic Equipment 2012/19/EU
- Registration, Evaluation, Authorization and Restriction of Chemicals (EC) No 1907/2006 (REACH)
You can download the EU Declaration of Conformity on the official website: https://en.goodwe.com.
02 Product Introduction
Battery Cabinet
Front View: Length
Right View: Width
Left View: Height
Handle
BS Routing Hole
Slot | Model | Length (mm) | Width (mm) | Height (mm) |
LX C101-10 | 1155 | 730 | 1650 | |
LX C120-10 | 1155 | 730 | 1650 | |
LX C138-10 | 1155 | 730 | 2065 | |
LX C156-10 | 1155 | 730 | 2065 |
Power Control Unit (PCU)
Components
Power Control Unit (PCU)
- 1. Battery Terminal (Positive)
- 2. DC Circuit Breaker
- 3. AC Circuit Breaker
- 4. Main Circuit Breaker
- 5. Indicator
- 6. Battery Terminal (Negative)
- 7. Power Input/Output Port (Negative)
- 8. AC Power Supply Port
- 9. Power Input/Output Port (Positive)
- 10. External COM Port
- 11. Internal COM Port
Battery Module
Diagram description: A rectangular battery module with dimensions 677mm height, 525mm width, and 202mm depth. It features connection points and mounting holes.
- 1. Connector for Battery Communication
- 2. Battery Positive Polarity
- 3. Battery Negative Polarity
- 4. Battery Hoisting Hole
- 5. Battery Fixing Hole
03 Installation
Deliverables
The following items are included in the package. 'N' denotes quantity depends on the specific system configuration.
Item | Description | Quantity |
Battery Module | Main battery unit | x N |
Battery Cabinet and Accessories | Cabinet structure and mounting hardware | x 1 |
Power Control Unit (PCU) | Main control electronics | x 1 |
DC Circuit Breaker | For DC power isolation | x 1 |
AC Circuit Breaker | For AC power isolation | x 1 |
Main Circuit Breaker | Primary circuit protection | x 1 |
Communication Cables | For data transfer | x 1 |
Power Cables | For electrical connection | x 1 |
Mounting Brackets | For securing components | x N |
Cable Ties | For cable management | x N |
User Manual | Detailed instructions | x 1 |
Grounding Cable | For safety grounding | x 1 |
PPE Kit | Personal Protective Equipment | x 1 |
Fasteners | Screws and bolts | x 4 |
Tools | Specific installation tools | x N |
Space Requirements
Ensure the following clearances around the battery system for proper ventilation and access:
- Front: 600mm
- Rear: 300mm
- Left Side: 600mm
- Right Side: 600mm
Angle Requirements
The battery system should be installed on a level surface. No specific angle requirements are indicated, implying a vertical, upright installation.
BS Installation
Follow these steps for the Battery System (BS) installation:
- Step 1: Position the battery cabinet.
- Step 2: Install the battery modules into the cabinet. This involves sliding modules into designated slots.
- Step 3: Secure the battery modules. Ensure a gap of 30-100mm between modules if multiple are installed side-by-side or stacked, as indicated by the diagram.
Diagram description: Shows a cabinet with slots for battery modules. Step 1 shows placing the cabinet. Step 2 shows inserting a module. Step 3 shows securing modules with a specified gap.
- Step 4: Connect internal components. This includes connecting power and communication cables between battery modules and the PCU. Torque specifications for M6 screws are 4.5-6 N·m.
- Step 5: Install the Power Control Unit (PCU) and connect it to the battery modules and external power/communication interfaces. The diagram shows numbered connection points and components within the cabinet.
Diagram description: Illustrates the internal wiring and component layout. Numbered points indicate connection locations for power and communication cables. Torque for M6 fasteners is specified as 4.5-6 N·m.
04 Electrical Connection
Cable Specification
No. | Cable | Type | Requirement |
1 | PE Cable | Single-core copper cable | Cross-sectional area of conductor SPE: 8mm². |
2 | Power cable to connect with the inverter | 1000V PV cables | Outer diameter of the cable: 11mm~13mm. Cross-sectional area of conductor S: 35mm². |
3 | Others | Delivered cable or connecting bar | Use the delivered cable or connecting bar. |
Connecting PE Cable
Diagram description: Shows a connection point labeled 'L' and a PE terminal. The PE cable (8mm²) is connected to the grounding terminal.
Connecting Inverter Communication Cable
Diagram description: Shows connections for communication cables to the PCU. Torque for M5 screws is 3.5-4.5 N·m.
No. | Definition |
3 | CANH |
4 | CANL |
7 | RS485A |
8 | RS485B |
Others | NA |
Connecting Battery Communication Cable
Diagram description: Shows numbered connection points (1-17) on the PCU and battery modules, illustrating the daisy-chain communication wiring between battery modules and the PCU. This ensures data exchange between all units.
Connecting Power Connecting Bar
Diagram description: Illustrates the connection of power busbars between battery modules and to the PCU. Torque for M8 screws is 10-12 N·m.
Connecting Inverter Power Cable
Diagram description: Shows the connection of the main power cable from the inverter to the PCU. The diagram indicates a specific orientation and a 'Click' confirmation for secure connection. The cable diameter is specified as 20±1mm.
(Optional) Connecting Single Phase AC Power Cable
Diagram description: Illustrates the optional connection of a single-phase AC power cable, likely for auxiliary power or specific configurations, showing connection points 1, 2, and 3.
05 Power ON and OFF
Power ON
Self-powered:
Diagram description: Shows a sequence of actions involving switches or indicators labeled 1, 2, and 3, indicating the power-on sequence for self-powered operation.
External single phase AC powering:
Diagram description: Shows a sequence of actions involving switches or indicators labeled 1 and 2, indicating the power-on sequence when using external AC power.
Power OFF
Self-powered:
Diagram description: Shows a sequence of actions involving switches or indicators labeled 1, 2, and 13, indicating the power-off sequence for self-powered operation.
External single phase AC powering:
Diagram description: Shows a sequence of actions involving switches or indicators labeled 1 and 2, indicating the power-off sequence when using external AC power.
06 Commissioning
Commissioning can be performed using the PV Master APP or the SEMS Portal.
For more information, please scan the following QR for User Manual. Lynx C Series User Manual
[Note: QR code replaced with text description as per instructions.]
Official Website
GoodWe Technologies Co., Ltd.
No. 90 Zijin Rd., New District, Suzhou, 215011, China