Nortek Global HVAC GXH24-36MSK4DH 2/3 Ton Inverter Split System Heat Pump ODU
Submittal Document
Inverter Split System Features and Benefits
- High efficiency heat pump system; up to 20 SEER and 10.5 HSPF
- Unparalleled heating performance; rated to -22°F with 100% nominal capacity to as low as -5°F
- 100% cooling capacity up to 115°F
- Fully-inverter-driven compressor is controlled in 1hz steps, outperforming few-speed compressors
- Side discharge outdoor Unit provides greater installation flexibility, requiring less space
- Capable of a braze-free installation, eliminating corrosive contaminants
- One system with two capacities set via the flip of a dip switch
- Long life PVE oil that does not break down in the presence of moisture
- One of the quietest outdoor units on the market
- Outdoor unit is sea coast rated showing no unexpected corrosion in 1500 hr salt spray test
- Control board indicates errors on easy-to-read display; no counting flashes
- Compatible with most 24V heat pump thermostats; non-communicating
- Multi-level self protection ensures a long, trouble-free equipment life
- Intelligent defrost ensures defrost operation only operates when needed
- Built-in base pan heater provides protection from freezing and ice build-up
- Built-in crankcase heater protects the compressor
- Fits standard mini-split-style outdoor unit wall brackets
- 10 Year, non-transferable, parts and compressor warranty; no registration requirement
- Includes Flexible Suction Line Connector for easily routing piping through the side or back
- Accumulator and oil separator protects the compressor
- Refrigerant Adjustment Tank removes or adds refrigerant to the circuit as needed
- Pre-charged for 31 feet of line set. No refrigerant adjustment needed for less than 31'
- Copper-tube/aluminum fin outdoor and indoor coil
- Independent lab-tested and verified heating operation to -22°F (78% of nominal capacity)
- Independent lab-tested and verified cooling operation to 130°F (78% of nominal capacity)
System Ratings
2 Ton | 3 Ton | |
---|---|---|
Rated Cooling Capacity | 24,000 | 36,000 |
Rated Heating Capacity | 24,000 | 36,000 |
SEER | 20 | 18 |
HSPF | 10.5 | 10 |
EER (95°) | 12.5 | 11 |
Voltage (Min-Max) | 187-253 | 187-253 |
MCA | 24 | 24 |
MOCP | 30 | 30 |
Ambient Operating Ranges
- Cooling: 5°F to 130°F
- Heating: -22°F to 75°F
- Max. Sound Pressure dB(A): 62 dB
Outdoor Unit Data
Compressor: Type: Inverter Rotary, RLA: 16, Model: QXFT-F310zN450, Oil: Polyvinylether (PVE)
Fan Motor: Type: Brushless DC, RLA: 0.53, Model: B-SWZ150A
Physical Characteristics
- Net Weight (lbs): 217.2
- Gross Weight (lbs): 240.3
- Height: 37"
- Width: 32-1/4"
- Depth: 18-1/8”
Refrigerant Piping Data
- Refrigerant Type: R-410A
- Max. Piping Length (ft): 98.4
- Pre-charged Amount (lbs): 93
- Max. Piping Height (ft): 49.2
- Pre-Charged Length (ft): 31.1
- Additional amount (Oz/ft.): 0.32
- ODU Connection Size (Liquid): 3/8"
- ODU Connection Size (Gas): 3/4"
Outdoor Unit Dimensions
Front View: Width: 37", Depth: 18-1/8"
Side View: Height: 32-1/4", Depth: 19-1/8"
Top View: Width: 24", Depth: 18-1/8"
Typical Installation Minimum Clearances
- Front: >12"
- Side: >4"
- Rear: >40" (for covered installation, refer to manual for details)
Covered Installation Examples
Diagram shows outdoor unit installed on a wall, with clearances for snow/water and roof overhangs. Another diagram shows installation on a balcony or deck with specified clearances.
Heating Capacity Comparison
2 Ton Unit
This graph compares the heating capacity (Btu/h) of the M-1 Ultra unit against two other models (Company B and 16 SEER) across various outdoor temperatures from -22°F to 48°F.
3 Ton Unit
This graph compares the heating capacity (Btu/h) of the M-1 Ultra unit against two other models (Company B and 16 SEER) across various outdoor temperatures from -22°F to 48°F.