Trane Horizon Outdoor Air Units

Trane Horizon™ Outdoor Air Units

Water-Source Heat Pumps | Air-Source Heat Pumps | Dedicated Outdoor Air Solutions

Horizon Heat Pump Solutions

Trane® Horizon™ Dedicated Outdoor Air System (DOAS) Units are a comprehensive line of products designed for year-round dew point control applications. Water-Source Heat Pumps (WSHP) and Air-Source Heat Pumps (ASHP) are now available on all Horizon models, enabling fully integrated and automated systems that leverage sustainable, high-efficiency comfort technology.

Key Features and Benefits

Moisture Removal

Dedicated Outdoor Air System (DOAS) Units dehumidify outdoor air before it enters a building's air delivery system. This ensures tightly controlled humidity, reduces the latent load, and improves overall energy efficiency. This function focuses on moisture removal, complementing temperature control systems.

Peerless Performance

Horizon DOAS Units with the WSHP option are designed to complement Trane Axiom™ Variable Speed Water-Source Heat Pumps, which feature highly efficient eFlex™ variable speed technology. An Axiom™ WSHP system with a ground loop installation can achieve up to 40 EER and deliver up to 60% energy savings.

Comfort Zone

Horizon DOAS Units are frequently paired with Axiom WSHP systems in multi-tenant buildings to provide fresh supply air for individual comfort system zones.

Broader Horizons: Integration and Application

The introduction of WSHP and ASHP options expands the Horizon series' capabilities, making it compatible with existing high-performance Trane heat pump technologies. This cost-effective renewable energy approach is ideal for new construction or upgrading existing systems.

  • Renovations: Choose the heat pump option appropriate for integration with your facility's existing heat pump system.
  • New Construction: Design a fully-integrated heat pump system from the ground up.

Personal Comfort Applications

Horizon Heat Pump Units are engineered to condition up to 100% outdoor air and can be fully integrated with building heat pump or terminal unit systems. They are well-suited for a wide range of building types, including:

  • Schools
  • Dormitories
  • Hotels/Lodging
  • Apartments
  • Condominiums
  • Assisted Living Facilities
  • Nursing Homes
  • Military Barracks
  • Commercial Food Service

Performance Standards and Heat Pump Systems

Performance Standards

Removing water from the air is known as dehumidification. Integrated Seasonal Moisture Removal Efficiency (ISMRE) is a detailed part-load calculation assessing how well a dedicated outdoor air solution performs under various conditions. The AHRI 920 certification program includes a dehumidification standard for up to 100% outdoor air and an ISMRE rating. Horizon™ Outdoor Air Units are designed to meet this performance benchmark.

Heat Pump Systems

Air and Water Source Heat Pump systems are among the most sustainable and environmentally responsible methods for heating and cooling buildings. Water Source Heat Pumps utilize the building's water loop to manage condenser heat, maximizing system efficiencies and reducing operating costs. All Horizon Air and Water Source Heat Pump Units can be equipped with an Energy Recovery Ventilator option to further enhance unit efficiency and energy savings.

Installation Options

WSHP coil systems offer versatile technology with several installation applications:

  • Boiler/cooling tower integration
  • Ground loop (geothermal) systems
  • Adjacent body of water (e.g., lake, river)

Horizon Outdoor Air Units: Model Range

The Horizon series provides a complete range of solutions for outdoor air units.

Model Tonnage Airflow
OAB 3 to 9 Tons 500 to 3000 CFM
OAD 5 to 15 Tons 625 to 4,000 CFM
OAG 10 to 30 Tons 1000 to 7500 CFM
OAK 12 to 30 Tons 1500 to 9000 CFM
OAN 30 to 54 Tons 3750 to 13,500 CFM

Unit Type Descriptions

Water-Source Heat Pumps (WSHP)

A grey, rectangular Water-Source Heat Pump unit designed for outdoor installation, showing duct connections and a robust casing. WSHP units are ideal solutions for academic, commercial, and institutional applications such as office buildings, hotels, healthcare facilities, schools, condominiums, and apartments.

Air-Source Heat Pumps (ASHP)

A grey, rectangular Air-Source Heat Pump unit, similar in design to the WSHP, with visible components and duct connections, often shown with an optional Energy Recovery Ventilator. ASHP units are well-suited for commercial applications and can be coupled with Energy Recovery Ventilation to maximize energy savings.

Installation and Service

Streamlined Installation

Trane® Horizon components are assembled, piped, wired, and tested at the factory. This facilitates a straightforward job site installation process, ensuring faster setup, increased reliability, and optimal performance.

Service Agreements

Planned maintenance through Trane service agreements helps maintain peak system efficiencies, conserve operating costs, and support budget goals.

Virtual Configurations

Trane provides Building Information Modeling (BIM) objects to support building design. Pre-populated physical and performance data for each product configuration saves time, increases accuracy, and simplifies the construction process.

PDF preview unavailable. Download the PDF instead.

OAU-SLB006-EN 2016 WEB Adobe PDF library 15.00 Adobe Illustrator CC 2015 (Macintosh)

Related Documents

Preview Trane Horizon Outdoor Air Unit Installation, Operation, and Maintenance Manual
Comprehensive guide for the installation, operation, and maintenance of Trane Horizon Outdoor Air Units, including Water Source Heat Pump models OABE, OADE, OAGE, OAKE, and OANE. Covers safety, procedures, and technical details.
Preview Trane Engineers Newsletter: AHRI 920 Standard for DX Dedicated Outdoor-Air Units
This Trane Engineers Newsletter article explains AHRI Standard 920 for rating DX Dedicated Outdoor-Air (DOA) units, comparing it with AHRI 340/360 and its impact on ASHRAE 90.1 efficiency requirements for HVAC systems.
Preview Trane Authorized Government Price List and Equipment Catalog
This document is the Trane Authorized Government Price List, detailing a comprehensive range of commercial HVAC equipment, building energy management systems, rental services, software, and educational materials available for government procurement. It includes product specifications, model numbers, and pricing information.
Preview Specifying DX Dedicated Outside Air Units: A White Paper on AHRI Standards
This white paper from Trane explains the importance of specifying Dedicated Outdoor Air Systems (DOAS) correctly, focusing on AHRI 920-2020 standards for efficiency and performance, and comparing them to older standards like AHRI 340/360.
Preview Trane Axiom Water Source Heat Pump Installation, Operation, and Maintenance Manual
Comprehensive guide for the installation, operation, and maintenance of Trane Axiom Water Source Heat Pumps (GEH/V series), covering model numbers from 0.5 to 25 tons, 50/60 Hz. Includes safety warnings, environmental concerns, model number breakdown, and detailed operational information.
Preview Trane Water Source Heat Pump Axiom™ High Efficiency Vertical Stack Installation, Operation, and Maintenance Manual
Comprehensive guide for the installation, operation, and maintenance of Trane's Axiom™ High Efficiency Vertical Stack Water Source Heat Pump, covering models from 0.75 to 3 Tons.
Preview Trane Odyssey™ Air-Cooled Chillers and Heat Pumps | CGA/CXA/VGA/VXA Models
Explore Trane's Odyssey™ range of air-cooled chillers and heat pumps (models CGA, CXA, VGA, VXA) for light commercial applications. Features include high efficiency, reliability, and simplified installation.
Preview Trane Horizon Outdoor Air Unit OAG: Installation, Operation, and Maintenance Manual
Comprehensive guide for the Trane Horizon Outdoor Air Unit (Model OAG), covering installation, operation, maintenance, safety warnings, and troubleshooting for direct gas-fired systems.