Juno RetroBasics™ 4" & 5/6" LED Adjustable Trim Kit - RBA Series
These instructions provide guidance for installing Juno RetroBasics™ LED adjustable trim kits.
Product Overview
The Juno RetroBasics™ LED trims are designed for use as retrofit trims for existing incandescent housings or with dedicated Juno quick connect housings.
Product Contents: Each unit carton typically contains 1 LED module and 1 E26 adapter (except for L/SKTWHIP models). Please verify all contents before installation.
Required Tools (not included): Safety glasses ? and gloves ?.
Product Listings & Specifications
- ETL certified to U.S. and Canadian safety standards.
- Energy Star qualified.
- Damp location listed.
- RB4A/RB4AC: Minimum lamp compartment diameter: 4 inches (102 mm); Minimum lamp compartment height: 3.47 inches (88 mm). Minimum lamp compartment volume: 39.63 in³ (650 cm³).
- RB56A/RB56AC: Minimum lamp compartment diameter: 5 inches (127 mm); Minimum lamp compartment height: 4 inches (101.6 mm). Minimum lamp compartment volume: 78 in³ (1278cm³).
- Suitable for use in open luminaires.
- Compatible with Type IC or Type Non-IC luminaires.
Important Safety Instructions
⚠️ WARNING: RISK OF DEATH, PERSONAL INJURY, OR PROPERTY DAMAGE
- Read all warnings and instructions included with the fixture and on fixture labels before installation, servicing, or maintenance.
- Installation and service should be performed by a qualified licensed electrician.
- Maintenance should be performed by persons familiar with the luminaire's construction, operation, and associated hazards. Regular maintenance is recommended.
- RISK OF ELECTRIC SHOCK: Disconnect or turn off power before installation or servicing. Verify supply voltage. Make all electrical and grounded connections according to the National Electrical Code (NEC) and applicable local codes. Use UL approved wire connectors.
- RISK OF INJURY: Wear safety glasses and gloves at all times. Avoid direct eye exposure to the light source while it is on.
- RISK OF BURN: Allow lamp/fixture to cool before handling. Do not touch enclosure or light source. Do not exceed maximum wattage.
- RISK OF FIRE: Keep combustible materials away from the lamp/lens. Do not operate near persons or combustible materials affected by heat.
- RISK OF PRODUCT DAMAGE: Never connect components under load. Avoid mounting methods that can cut wire insulation. Never connect an LED product to an unapproved dimmer pack. Allow for adequate airspace around the fixture to prevent overheating. Maximum ambient temperature is 90°C.
- Electrostatic Discharge (ESD): ESD can damage LED fixtures. Use personal grounding equipment during installation or servicing. Do not touch individual electrical components.
- No user-serviceable parts are inside the unit. Do not rewire, reconfigure, modify, or attempt repairs. Field replacement of LED assembly or lamps is not allowed by UL standards. Contact an ABL representative for service.
FCC Compliance
This equipment complies with Part 15 of the FCC Rules for Class B digital devices, designed to provide reasonable protection against harmful interference in residential installations. If interference occurs, try reorienting the antenna, increasing separation, or connecting to a different circuit. Operation is subject to the conditions that the device does not cause harmful interference and accepts any received interference.
Juno LED Trim Kit Compatibility in Recessed Cans
Juno LED Trim Kits are designed to work with most standard UL listed recessed incandescent housings. An E26 adapter must be used with standard medium base incandescent housings. Housing compatibility can be determined by measuring the recessed housing diameter and height. The following chart provides guidelines; actual installation is the best method for determining compatibility.
Feature | RB 4" | RB 5/6" |
---|---|---|
Internal Diameter | 4" min | 5" min |
Internal Height | 3.47" min | 4" min |
Trim Flange Diameter | 5.25" | 7.6" |
Preparation & Installation into Recessed Housing
Trims provided with Torsion Spring Brackets (Models RB56A and RB56AC Only)
- Remove old trim. Ensure input power is 120V. This kit is designed for 5" and 6" recessed housings with torsion spring retaining brackets.
- Install E26 adapter into existing housings with medium base sockets (See Figure 1). Skip to Step 3 if using a dedicated quick connect housing.
- For RB56A models, select desired color temperature using the switch on the trim.
- Pre-bend trim torsion springs to aid installation.
- Plug the orange connector of the E26 socket adapter into the mating orange connector on the trim, pushing firmly to secure (See Figure 2).
- For dedicated quick connect housings, plug the provided connector on the trim into the housing's mating connector, pushing firmly to secure (See Figure 3).
- Insert torsion springs into corresponding retaining brackets, squeezing them together. Slide into brackets, release springs, and gently push trim into housing until flush with ceiling (See Figures 4 & 6). The trim can be aimed by tilting and rotating the adjustable head.
Note: RB56A/RB56AC modules use only torsion springs. No extra grounding connection hardwire kit is supplied. Do not let the module hang unsupported by the connector.
Trims Provided with Retention Spring Clips (Models RB4A and RB4AC Only)
- Remove old trim. Ensure input power is 120V.
- Install E26 adapter into existing housings with medium base sockets (See Figure 1). Skip to Step 3 if using a dedicated quick connect housing.
- For RB4A models, select desired color temperature using the trim switch.
- Slightly tilt the trim head before installation to ensure desired orientation.
- Plug the orange connector of the E26 socket adapter into the trim's mating orange connector, pushing firmly to secure (See Figure 2).
- For dedicated quick connect housings, plug the provided connector on the trim into the housing's mating connector, pushing firmly to secure (See Figure 3).
- Insert friction retention springs into the housing by flexing them inward. Gently push trim into housing until flush with ceiling (See Figures 5 & 6).
Note: RB4A/RB4AC modules use only friction retention springs. No extra grounding connection hardwire kit is supplied. Do not let the module hang unsupported by the connector. Align springs with housing, avoiding obstructions. For removal, pull down and rotate. A flat blade screwdriver may help release clips.
Recommendation: Use gloves to avoid transferring dirt and fingerprints during installation.
Color Temperature Adjustment
For Model SWW5: Select desired CCT (2700K warm, 3000K, 3500K, 4000K cool, or 5000K daylight) by positioning the switch on the trim (See Figure 7).
For Smart Models (RB4AC & RB56AC ONLY): Tunable White CCT settings are configured via supported mobile apps (Amazon Alexa, Google Home, SmartThings). Refer to the Quick Start Guide for pairing instructions.
Recommended Dimming Switches
For Model SWW5: The LED Modules are compatible with many standard residential dimmers. A list of recommended dimmers is available at www.acuitybrands.com (search keyword: RB4A or RB56A). A dimmer not on the list may still be compatible; consult the dimmer manufacturer for details.
For Smart Models (RB4AC & RB56AC ONLY): These models cannot be wired with wall dimmers. Dimming settings are configured via supported mobile apps.