INTRODUCTION
Thanks for choosing the SkyRC BD350 discharger. The BD350 discharger supports most RC batteries and works with the SkyRC T1000* charger, offering a discharge current of up to 40A and a discharge power of 350W.
*More models are expected to be compatible in the future; updates will be posted on the website.
Analyze via Charge Master PC Software
The BD350 is more than a simple battery discharger; it is a powerful test instrument. It measures, graphs, and compares the parameters of various batteries, allowing for precise measurement of battery capacity and performance. Eliminate guesswork when selecting the optimal battery for RC racing.
OPERATION INSTRUCTION
Discharge
Follow these steps for discharging:
- Upon connecting the power supply, the T1000 automatically powers on and enters the main menu.
- Connect the BD350 discharger to the T1000.
Diagram Description: A visual representation shows the BD350 discharger connected to the SKYRC T1000 Maestro charger. The T1000 charger is then connected to a LiPo Battery via Port A.
- Discharge the battery by connecting it to the T1000 on Port A.
- Select 'Discharge' mode on the T1000: set the cut-off voltage, the discharge current, and the number of cells.
- Start the program.
SPECIFICATION
Parameter | Value |
---|---|
Working Voltage | DC 5V |
Discharge Power | 350W |
Discharge Current | 0.1-40A |
Over Temp. Protection | >95°C |
Working Temp. | 0°C~40°C |
Working Humidity | 0%~75% |
Size | 157*105*93mm |
Net Weight | 1224g |
EXPLANATION OF STATUS LEDS
LED | Status |
---|---|
Stays Green | Standby |
Stays Red | Discharging |
Flashes Red | Error |
MAXIMUM DISCHARGE POWER CHART
This chart provides maximum discharge current and power ratings for various battery types and cell counts when discharging at 350W.
Battery Type | No. of Cell | Min. Cut-off Voltage | Discharging power: 350W | ||
---|---|---|---|---|---|
Voltage | Min. Discharge Current (A) | Max. Discharge Current (A) | |||
LiPo | 2S | 6.0 | 8.40 | 40.00 | 40.00 |
3S | 9.0 | 12.60 | 27.77 | 38.88 | |
4S | 12.0 | 16.80 | 20.83 | 29.16 | |
5S | 15.0 | 21.00 | 16.66 | 23.33 | |
6S | 18.0 | 25.20 | 13.88 | 19.44 | |
7S | 21.0 | 29.40 | 11.90 | 16.66 | |
8S | 24.0 | 33.60 | 10.41 | 14.58 | |
LiHV | 2S | 6.2 | 8.70 | 40.00 | 40.00 |
3S | 9.3 | 13.05 | 26.81 | 37.63 | |
4S | 12.4 | 17.40 | 20.11 | 28.22 | |
5S | 15.5 | 21.75 | 16.09 | 22.58 | |
6S | 18.6 | 26.10 | 13.40 | 18.81 | |
7S | 21.7 | 30.45 | 11.49 | 16.12 | |
8S | 24.8 | 34.80 | 10.05 | 14.11 | |
NiMH | 6S | 5.4 | 9.00 | 38.88 | 40.00 |
7S | 6.3 | 10.50 | 33.33 | 40.00 | |
8S | 7.2 | 12.00 | 29.16 | 40.00 | |
9S | 8.1 | 13.50 | 25.92 | 40.00 | |
10S | 9.0 | 15.00 | 23.33 | 38.88 | |
11S | 9.9 | 16.50 | 21.21 | 35.35 | |
12S | 10.8 | 18.00 | 19.44 | 32.40 | |
13S | 11.7 | 19.50 | 17.94 | 29.91 | |
14S | 12.6 | 21.00 | 16.66 | 27.77 | |
15S | 13.5 | 22.50 | 15.55 | 25.92 | |
16S | 14.4 | 24.00 | 14.58 | 24.30 | |
17S | 15.3 | 25.50 | 13.72 | 22.87 | |
18S | 16.2 | 27.00 | 12.96 | 21.60 | |
19S | 17.1 | 28.50 | 12.28 | 20.46 | |
20S | 18.0 | 30.00 | 11.66 | 19.44 |
SAFETY NOTE
Improper usage may lead to fire, property damage, and physical injury.
- Never discharge a battery below its recommended cut-off voltage. Over-discharge may damage the battery and cause fire or explosion.
- Never discharge a battery at a higher discharge rate than it is designed for.
- Never leave the discharger unattended when it is connected to a battery. If any malfunction is found, terminate the process immediately.
- Place the discharger and battery on a non-flammable surface, and keep them away from inflammables.
- Never discharge swollen, leaky, or damaged batteries.
- Batteries shall be discharged within a room temperature range of 10°C-40°C.
- Disconnect the battery and discharger once the discharge process has finished.
- Recharge batteries immediately with an appropriate battery charger after the discharge process is completed.
- Some battery types do not tolerate remaining discharged for extended periods of time.
LIABILITY EXCLUSION
This charger is designed and approved exclusively for use with the types of batteries stated in this Instruction Manual. SkyRC accepts no liability of any kind if the charger is used for any purpose other than that stated. We are unable to ensure that you follow the instructions supplied with the charger, and we have no control over the methods you employ for using, operating, and maintaining the device. For this reason, we are obliged to deny all liability for loss, damage, or costs that are incurred due to incompetent or incorrect use and operation of our products, or which are connected with such operation in any way. Unless otherwise prescribed by law, our obligation to pay compensation, regardless of the legal argument employed, is limited to the invoice value of those SkyRC products which were immediately and directly involved in the event in which the damage occurred.
WARRANTY AND SERVICE
We guarantee this product to be free of manufacturing and assembly defects for a period of one year from the time of purchase. The warranty only applies to material or operational defects present at the time of purchase. During that period, we will repair or replace, free of service charge, products deemed defective due to those causes.
This warranty is not valid for any damage or subsequent damage arising as a result of misuse, modification, or failure to observe the procedures outlined in this manual.
Note:
- The warranty service is valid in China only.
- If you need warranty service overseas, please contact your dealer in the first instance, who is responsible for processing guarantee claims overseas. Due to high shipping costs and complicated custom clearance procedures to send back to China, please understand SkyRC cannot provide warranty service to overseas end-users directly.
- If you have any questions not mentioned in the manual, please feel free to send an email to info@skyrc.com.