1. Test Purpose
By building test scenarios and simulating the customer's usage environment, we test whether the module's performance meets the customer's requirements.
2. Test Result Summary
Test Items | Test Result |
---|---|
Muti-Version | Pass |
Connectivity | Pass |
Module Basic Information | Pass |
Digital Diagnostic Monitoring | Pass |
3. Test Equipment Used
Vendor | Device | Soft Version/Compatible Brand | Serial Number |
---|---|---|---|
Cisco Switch | C9500-24Y4C | 17.03.03 | / |
FS Optical Transceiver Module | SFP-1G34-BX10 | Cisco Compatible | A1910000061 A1910000051 |
4. Test Data
4.1 Test Scenario
Network Topology
Description: A network topology diagram shows two 1Gbps links. One link connects a Cisco C9500-24Y4C switch to an SFP-1G34-BX10 module. The other link connects another SFP-1G34-BX10 module to a Cisco C9500-24Y4C switch.
Interoperability Test Scenario
Description: An image depicts a rack of network equipment, illustrating the interoperability test setup.
Test Premise
- Confirm the brand, quantity, and placement of the switches to be tested.
- Prepare control cables, test software, and optical fiber patch cords. Power on the switches in advance.
- Locate the Console port on the switch (marked as "CON", "IOIOI", or a computer monitor icon). Connect the switch to the computer using a control cable.
Test Method
Before connecting the software, confirm the control cable's connection port in the computer's device manager (COM and LPT ports). Open SecureCRT Portable software and enter the quick connection interface.
- Protocol selection: Serial
- Port selection: Match the port viewed in the previous step.
- Baud rate selection: Match the baud rate of the port on the target switch.
- Flow control: Do not check this option.
Remaining configurations can keep default values.
Description of SecureCRT Quick Connect Interface: A dialog box with fields for Protocol (Serial), Port (e.g., COM28), Baud rate (e.g., 38400), Data bits (8), Parity (None), Stop bits (1). Options include "Show quick connect on startup", "Save session", "Open in a tab". Buttons: "Connect", "Cancel".
4.2 Test Result
Test Steps
- Insert the optical module into the corresponding rate port of the switch. Connect TX-RX ends with an optical fiber jumper or MTP self-loop device. Verify module connection. If not connected, check jumper or switch port configuration.
- Enter the test interface, input account and password, log in to the switch, and enter privileged mode.
- Using the switch command configuration table, input test commands and view relevant information: port status (connectivity), connection rate, alarm status, module basic information, DDM information, etc. Determine if requirements are met.
Switch Model and Version Information
Command: C9500-24Y4C#show ver
Cisco IOS XE Software, Version 17.03.03 Cisco IOS Software [Amsterdam], Catalyst L3 Switch Software (CAT9K_IOSXE), Version 17.3.3, RELEASE SOFTWARE (fc7) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2021 by Cisco Systems, Inc. Compiled Thu 04-Mar-21 12:32 by mcpre Cisco IOS-XE software, Copyright (c) 2005-2021 by cisco Systems, Inc. All rights reserved. Certain components of Cisco IOS-XE software are licensed under the GNU General Public License ("GPL") Version 2.0. The software code licensed under GPL Version 2.0 is free software that comes with ABSOLUTELY NO WARRANTY. You can redistribute and/or modify such GPL code under the terms of GPL Version 2.0. For more details, see the documentation or "License Notice" file accompanying the IOS-XE software, or the applicable URL provided on the flyer accompanying the IOS-XE software. ROM: IOS-XE ROMMON BOOTLDR: System Bootstrap, Version 17.8.1r[FC1], RELEASE SOFTWARE (P) C9500-24Y4C uptime is 0 minutes Uptime for this control processor is 2 minutes System returned to ROM by PowerOn System image file is "bootflash:cat9k_iosxe.17.03.03.SPA.bin" Last reload reason: PowerOn
Interface Status for C9500-24Y4C
Command: C9500-24Y4C#show interfaces status
Port | Name | Status | Vlan | Duplex | Speed | Type |
---|---|---|---|---|---|---|
Twe1/0/1 | connected | routed | full | 1000 | 1000BaseBX-10D SFP | |
Twe1/0/2 | notconnect | routed | auto | auto | unknown | |
Twe1/0/3 | connected | 1 | full | 1000 | 1000BaseBX-10U SFP | |
Twe1/0/4 | notconnect | 1 | auto | auto | unknown | |
Twe1/0/5 | connected | 1 | full | 1000 | 1000BaseBX-10D SFP | |
Twe1/0/6 | notconnect | 1 | auto | auto | unknown | |
Twe1/0/7 | connected | 1 | full | 1000 | 1000BaseBX-10U SFP | |
Twe1/0/8 | notconnect | 1 | auto | auto | unknown | |
Twe1/0/9 | notconnect | 1 | auto | auto | unknown | |
Twe1/0/10 | notconnect | routed | auto | auto | unknown | |
Twe1/0/11 | notconnect | 1 | auto | auto | unknown | |
Twe1/0/12 | notconnect | 1 | auto | auto | unknown | |
Twe1/0/13 | notconnect | 1 | auto | auto | unknown | |
Twe1/0/14 | notconnect | 1 | auto | auto | unknown | |
Twe1/0/15 | notconnect | routed | auto | auto | unknown | |
Twe1/0/16 | notconnect | 1 | auto | auto | unknown | |
Twe1/0/17 | notconnect | 1 | auto | auto | unknown | |
Twe1/0/18 | notconnect | 1 | auto | auto | unknown | |
Twe1/0/19 | notconnect | 1 | auto | 25G | unknown | |
Twe1/0/20 | notconnect | 1 | auto | 25G | unknown | |
Twe1/0/21 | notconnect | 1 | auto | 25G | unknown | |
Twe1/0/22 | notconnect | 1 | auto | auto | unknown | |
Twe1/0/23 | notconnect | 1 | auto | auto | unknown | |
Twe1/0/24 | notconnect | 1 | auto | auto | unknown | |
Hu1/0/25 | notconnect | routed | auto | auto | unknown | |
Hu1/0/26 | notconnect | routed | auto | auto | unknown | |
Hu1/0/27 | notconnect | routed | auto | auto | unknown | |
Hu1/0/28 | notconnect | routed | auto | auto | unknown |
Test Information
Module Basic Information (from switch side)
Description: IDPROM information for transceiver TwentyFiveGigE1/0/3 and TwentyFiveGigE1/0/7.
Transceiver TwentyFiveGigE1/0/3 Details:
- Description: SFP or SFP+ optics (type 3)
- Transceiver Type: 1000BASE BX10-U (259)
- Product Identifier (PID): GLC-BX-U
- Vendor Revision: A0
- Serial Number (SN): A1910000061
- Vendor Name: FS
- Vendor OUI (IEEE company ID): 00.00.00 (0)
- CLEI code: IPUIAG5RAB
- Cisco part number: 10-2094-02
- Device State: Enabled.
- Date code (yy/mm/dd): 19/02/20
- Connector type: LC.
- Encoding: 8B10B (1)
- Nominal bitrate: GE (1300 Mbits/s)
- Minimum bit rate as % of nominal bit rate: not specified
- Maximum bit rate as % of nominal bit rate: not specified
- The transceiver type is 259
- Link reach for 9u fiber (m): 1xFC, 2xFC-SM(10km) (100)
- Link reach for 50u fiber (m): SR(2km) (0), IR-1(15km) (0), IR-2(40km) (0), LR-1(40km) (0), LR-2(80km) (0), LR-3(80km) (0), DX(40KM) (0), HX(40km) (0), ZX(80km) (0), VX(100km) (0), 1xFC, 2xFC-SM(10km) (0), ESCON-SM(20km) (0)
- Link reach for 62.5u fiber (m): SR(2km) (0), IR-1(15km) (0), IR-2(40km) (0), LR-1(40km) (0), LR-2(80km) (0), LR-3(80km) (0), DX(40KM) (0), HX(40km) (0), ZX(80km) (0), VX(100km) (0), 1xFC, 2xFC-SM(10km) (0), ESCON-SM(20km) (0)
- Nominal laser wavelength: 1310 nm.
- DWDM wavelength fraction: 1310.0 nm.
- Supported options: Tx disable, Tx fault signal, Loss of signal (standard implementation)
- Supported enhanced options: Alarms for monitored parameters
- Diagnostic monitoring: Software Tx disable, Software Tx fault monitoring, Software Rx LOS monitoring. Digital diagnostics supported. Diagnostics are internally calibrated. Rx power measured is "Average power".
- Transceiver temperature operating range: not specified
- Minimum operating temperature: 0 C
- Maximum operating temperature: 70 C
- High temperature alarm threshold: +75.000 C
- High temperature warning threshold: +70.000 C
- Low temperature warning threshold: +0.000 C
- Low temperature alarm threshold: -5.000 C
- High voltage alarm threshold: 3630.0 mVolts
- High voltage warning threshold: 3460.0 mVolts
- Low voltage warning threshold: 3130.0 mVolts
- Low voltage alarm threshold: 2970.0 mVolts
- High laser bias current alarm threshold: 110.000 mAmps
- High laser bias current warning threshold: 100.000 mAmps
- Low laser bias current warning threshold: 2.000 mAmps
- Low laser bias current alarm threshold: 1.000 mAmps
- High transmit power alarm threshold: -1.0 dBm
- High transmit power warning threshold: -2.0 dBm
- Low transmit power warning threshold: -10.0 dBm
- Low transmit power alarm threshold: -11.0 dBm
- High receive power alarm threshold: -1.0 dBm
- High receive power warning threshold: -2.0 dBm
- Low receive power warning threshold: -24.0 dBm
- Low receive power alarm threshold: -24.9 dBm
- External Calibration: bias current slope = 1.000
- External Calibration: bias current offset = 0
Transceiver TwentyFiveGigE1/0/7 Details:
- Description: SFP or SFP+ optics (type 3)
- Transceiver Type: 1000BASE BX10-U (259)
- Product Identifier (PID): GLC-BX-U
- Vendor Revision: A0
- Serial Number (SN): A1910000051
- Vendor Name: FS
- Vendor OUI (IEEE company ID): 00.00.00 (0)
- CLEI code: IPUIAG5RAB
- Cisco part number: 10-2094-02
- Device State: Enabled.
- Date code (yy/mm/dd): 19/02/20
- Connector type: LC.
- Encoding: 8B10B (1)
- Nominal bitrate: GE (1300 Mbits/s)
- Minimum bit rate as % of nominal bit rate: not specified
- Maximum bit rate as % of nominal bit rate: not specified
- The transceiver type is 259
- Link reach for 9u fiber (m): 1xFC, 2xFC-SM(10km) (100)
- Link reach for 50u fiber (m): SR(2km) (0), IR-1(15km) (0), IR-2(40km) (0), LR-1(40km) (0), LR-2(80km) (0), LR-3(80km) (0), DX(40KM) (0), HX(40km) (0), ZX(80km) (0), VX(100km) (0), 1xFC, 2xFC-SM(10km) (0), ESCON-SM(20km) (0)
- Link reach for 62.5u fiber (m): SR(2km) (0), IR-1(15km) (0), IR-2(40km) (0), LR-1(40km) (0), LR-2(80km) (0), LR-3(80km) (0), DX(40KM) (0), HX(40km) (0), ZX(80km) (0), VX(100km) (0), 1xFC, 2xFC-SM(10km) (0), ESCON-SM(20km) (0)
- Nominal laser wavelength: 1310 nm.
- DWDM wavelength fraction: 1310.0 nm.
- Supported options: Tx disable, Tx fault signal, Loss of signal (standard implementation)
- Supported enhanced options: Alarms for monitored parameters
- Diagnostic monitoring: Software Tx disable, Software Tx fault monitoring, Software Rx LOS monitoring. Digital diagnostics supported. Diagnostics are internally calibrated. Rx power measured is "Average power".
- Transceiver temperature operating range: not specified
- Minimum operating temperature: 0 C
- Maximum operating temperature: 70 C
- High temperature alarm threshold: +75.000 C
- High temperature warning threshold: +70.000 C
- Low temperature warning threshold: +0.000 C
- Low temperature alarm threshold: -5.000 C
- High voltage alarm threshold: 3630.0 mVolts
- High voltage warning threshold: 3460.0 mVolts
- Low voltage warning threshold: 3130.0 mVolts
- Low voltage alarm threshold: 2970.0 mVolts
- High laser bias current alarm threshold: 110.000 mAmps
- High laser bias current warning threshold: 100.000 mAmps
- Low laser bias current warning threshold: 2.000 mAmps
- Low laser bias current alarm threshold: 1.000 mAmps
- High transmit power alarm threshold: -1.0 dBm
- High transmit power warning threshold: -2.0 dBm
- Low transmit power warning threshold: -10.0 dBm
- Low transmit power alarm threshold: -11.0 dBm
- High receive power alarm threshold: -1.0 dBm
- High receive power warning threshold: -2.0 dBm
- Low receive power warning threshold: -24.0 dBm
- Low receive power alarm threshold: -24.9 dBm
- External Calibration: bias current slope = 1.000
- External Calibration: bias current offset = 0
3. Read the DDM information of the module
DDM Information for TwentyFiveGigE 1/0/3
Command: C9500-24Y4C#show interfaces twentyFiveGigE 1/0/3 transceiver detail
ITU Channel not available (1490.0 nm). Transceiver is internally calibrated. mA: milliamperes, dBm: decibels (milliwatts), NA or N/A: not applicable. ++: high alarm, +: high warning, -: low warning, --: low alarm. A2D readouts (if they differ), are reported in parentheses. The threshold values are calibrated.
Port | Temperature Threshold (Celsius) | ||||
---|---|---|---|---|---|
High Alarm | High Warn | Low Warn | Low Alarm | ||
Twe1/0/3 | 26.6 | 75.0 | 70.0 | 0.0 | -5.0 |
Port | Voltage Threshold (Volts) | ||||
---|---|---|---|---|---|
High Alarm | High Warn | Low Warn | Low Alarm | ||
Twe1/0/3 | 3.28 | 3.63 | 3.46 | 3.13 | 2.97 |
Port | Current Threshold (milliamperes) (mA) | |||||
---|---|---|---|---|---|---|
High Alarm | High Warn | Low Warn | Low Alarm | |||
Twe1/0/3 | N/A | 14.9 | 110.0 | 100.0 | 2.0 | 1.0 |
Port | Optical Transmit Power Threshold (dBm) | |||||
---|---|---|---|---|---|---|
High Alarm | High Warn | Low Warn | Low Alarm | |||
Twe1/0/3 | N/A | -5.3 | -1.0 | -2.0 | -10.0 | -11.0 |
Port | Optical Receive Power Threshold (dBm) | |||||
---|---|---|---|---|---|---|
High Alarm | High Warn | Low Warn | Low Alarm | |||
Twe1/0/3 | N/A | -5.0 | -1.0 | -2.0 | -24.0 | -24.9 |
DDM Information for TwentyFiveGigE 1/0/7
Command: C9500-24Y4C#show interfaces twentyFiveGigE 1/0/7 transceiver detail
ITU Channel not available (1490.0 nm). Transceiver is internally calibrated. mA: milliamperes, dBm: decibels (milliwatts), NA or N/A: not applicable. ++: high alarm, +: high warning, low warning, --: low alarm. A2D readouts (if they differ), are reported in parentheses. The threshold values are calibrated.
Port | Temperature Threshold (Celsius) | ||||
---|---|---|---|---|---|
High Alarm | High Warn | Low Warn | Low Alarm | ||
Twe1/0/3 | 26.6 | 75.0 | 70.0 | 0.0 | -5.0 |
Port | Voltage Threshold (Volts) | ||||
---|---|---|---|---|---|
High Alarm | High Warn | Low Warn | Low Alarm | ||
Twe1/0/3 | 3.28 | 3.63 | 3.46 | 3.13 | 2.97 |
Port | Current Threshold (milliamperes) (mA) | |||||
---|---|---|---|---|---|---|
High Alarm | High Warn | Low Warn | Low Alarm | |||
Twe1/0/3 | N/A | 14.9 | 110.0 | 100.0 | 2.0 | 1.0 |
Port | Optical Transmit Power Threshold (dBm) | |||||
---|---|---|---|---|---|---|
High Alarm | High Warn | Low Warn | Low Alarm | |||
Twe1/0/3 | N/A | -5.3 | -1.0 | -2.0 | -10.0 | -11.0 |
Port | Optical Receive Power Threshold (dBm) | |||||
---|---|---|---|---|---|---|
High Alarm | High Warn | Low Warn | Low Alarm | |||
Twe1/0/3 | N/A | -5.0 | -1.0 | -2.0 | -24.0 | -24.9 |
Test Conclusion
After completing the above test content, all the test information should be copied and pasted into a TXT document.