Sealey Information Requirements for Gaseous/Liquid Fuel Local Space Heaters
Product Identification and General Specifications
Model Identifier(s): ABI600COMBO
Indirect Heating Functionality: Yes
Direct Heat Output: 50 kW
Indirect Heat Output: NA kW
Fuel Type: Liquid
Specify Fuel: Diesel / Kerosene
Space Heating Emissions (NOx): 108 [mg/kWhinput] (GCV)
Heat Output and Efficiency
Item | Symbol | Value | Unit | Item | Symbol | Value | Unit |
---|---|---|---|---|---|---|---|
Nominal heat output | Pnom | 50 | kW | Useful efficiency at nominal heat output | ηnom | 96.0 | % |
Minimum heat output (indicative)* | Pmin | NA | kW | Useful efficiency at minimum heat output (indicative)* | ηmin | NA | % |
Seasonal space heating efficiency | ηs | 89.1 | % |
* Enter figure or NA
Auxiliary Electricity Consumption and Heat Output/Room Temperature Control
Item | Symbol | Value | Unit | Item | Yes | No | |
---|---|---|---|---|---|---|---|
At nominal heat output | elmax | 0.900 | kW | Single stage heat output, no room temperature control | Yes ✔ | No | |
At minimum heat output | elmin | NA | kW | Two or more manual stages, no room temperature control | Yes | No ✔ | |
With mechanical thermostat room temperature control | Yes | No ✔ | |||||
With electronic room temperature control | Yes ✔ | No | |||||
With electronic room temperature control plus day timer | Yes | No ✔ | |||||
With electronic room temperature control plus week timer | Yes | No ✔ |
Power Consumption and Other Control Options
Item | Symbol | Value | Unit | Item | Yes | No | |
---|---|---|---|---|---|---|---|
In off-mode | Po | NA | W | Other control options (multiple selections possible) | |||
In standby mode | Psm | NA | W | Room temperature control, with presence detection | Yes | No ✔ | |
In idle mode | Pidle | NA | W | Room temperature control, with open window detection | Yes | No ✔ | |
In networked standby mode | Pnsm | NA | W | With distance control option | Yes | No ✔ | |
Standby mode with display information or status | NA | W | With adaptive start control | Yes | No ✔ | ||
With working time limitation | Yes | No ✔ | |||||
With black bulb sensor | Yes | No ✔ | |||||
With self-learning functionality | Yes | No ✔ | |||||
With control accuracy | Yes | No ✔ |
Permanent Pilot Flame Power Requirement
Item | Symbol | Value | Unit | ||||
---|---|---|---|---|---|---|---|
Pilot flame power required (if applicable)* | Ppilot | NA | kW |