Evonic Fires Insets Instruction Manual

This manual provides comprehensive instructions for the Evonic Fires Insets range of electric fireplaces.

Models Covered

Ev4i, Ev4i4, Ev6i, Ev6i4, Kepler 22, Colorado, Oberon, Topaz, Strellar, Sphera, Argenta 16, Argenta 22.

Contents

  1. EU Directives and UKCA Standards
  2. Important Information and Health & Safety
  3. Components for Insets
  4. Operating Instructions
  5. Installation
  6. Removing the Glass
  7. Fitting the Fascia
  8. Troubleshooting
  9. Warranty

EU Directives and UKCA Standards

All Evonic Fires products meet the requirements of the EC Directives and are in conformity with relevant UK Statutory Instruments.

EC Directives Compliance:

Designated Standards:

UKCA Standards Compliance:

Important Information and Health & Safety

Components for Insets

Name Fuel Sets Suction Lifters Remote Control (Optional) Spacer (Optional) Frame Frame Fret Infill Plate Installation Kit Magnets Cast Frame Fixing Kit Electrical Lead Inset Instruction Manual
Colorado Logs / Pebbles White/Beach / Log & Pebbles / Coals 2 x YES 75mm 1 x 4 x 1 x 1 x 1 x 1 x
Ev4i Logs / Pebbles White/Beach / Log & Pebbles / Coals 2 x YES 1 x 4 x 1 x 1 x 1 x 1 x
Ev4i4 Logs / Pebbles White/Beach / Log & Pebbles / Coals 2 x YES 1 x 4 x 1 x 1 x 1 x 1 x
Ev6i Logs / Pebbles White/Beach / Log & Pebbles / Coals 2 x YES 1 x 4 x 1 x 1 x 1 x 1 x
Ev6i4 Logs / Pebbles White/Beach / Log & Pebbles / Coals 2 x YES 1 x 4 x 1 x 1 x 1 x 1 x
Kepler 22 Logs / Pebbles White/Beach / Log & Pebbles / Coals 2 x YES 75mm 1 x 4 x 1 x 1 x 1 x 1 x
Oberon Logs / Pebbles White/Beach / Log & Pebbles / Coals YES 1 x 1 x fret 2 x screws 1 x 1 x 1 x 1 x 1 x
Strellar Logs / Pebbles White/Beach / Log & Pebbles / Coals 2 x YES 1 x 1 x fret 2 x screws 1 x infill 2 x screws 1 x 1 x 1 x 1 x
Argenta 16 Kindling log set 2 x YES 1 x 4 x 1 x 1 x 1 x 1 x
Argenta 22 Kindling log set 2 x YES 1 x 4 x 1 x 1 x 1 x 1 x
Sphera Kindling log set 2 x YES 1 x 4 x 1 x 1 x 1 x 1 x
Topaz Logs / Pebbles White/Beach / Log & Pebbles / Coals YES 1 x 4 x 1 x 1 x 1 x 1 x

Operating Instructions

Manual Operation

Operate the appliance using the manual rocker switches on the right-hand side. There is no manual dimmer control.

Remote Control Operation

Operate the appliance using the optional remote control. Ensure the appliance's rocker switch is in the I/On position.

Installation

All inset models are designed to fit into a standard 16" wide x 22" high opening. Verify dimensions of both the appliance and the opening before installation. If installing into an existing chimney breast, ensure the flue is adequately blocked off.

Installation Process Overview

The installation process varies slightly by model and desired installation type (Slide In, Tie Back, Free-standing Spacer, Wall Mounted). Refer to the specific sections below.

Slide In Installation (Models: Ev4i, Ev4i4, Ev6i, Ev6i4)

Once dimensions are checked, attach the electrical lead to the power inlet on the back lower right. Connect to mains power, then slide the appliance into the prepared opening. The opening should be approximately 16" (406mm) wide and 22" (559mm) high.

Tie Back Models (Models: Oberon, Strellar)

Strellar Infill Plate: The Strellar model includes an infill plate and 2 screws. Attach the plate by screwing it into the two holes on either side of the plate, aligning with the appliance's front screw holes.

Strellar & Oberon Installation: Attach the electrical lead to the power inlet on the back lower right and plug into mains power. Using the Cast Frame fixing kit, drill and fit 2 wall plugs and 2 screw eyes inside the wall opening. Thread the electrical cable through an appliance hole, then through the eye screws, and back through another appliance hole. Move the appliance into the opening, pull the cable end against the appliance, feed the barrel clamp onto the cable, and screw it tight while maintaining tension. Cut the cable approximately 50mm from the barrel clamp.

With Spacer (Models: Colorado, Kepler 22)

To convert to a free-standing unit, fit an optional spacer. Before securing, attach the electrical lead to the inlet at the back bottom corner. Position the spacer at the back of the appliance, aligning three screw holes on both the appliance and spacer. Screw them together. The electrical lead can then slot into the semi-circular hole, allowing the appliance to sit free-standing on the floor.

Wall Mounted Installation (Models: Ev4i4, Ev6i4, Topaz)

Once measurements are confirmed, plug in the appliance and slide it into the prepared opening. The appliance can then be screwed to the wall using the four screw holes indicated.

Model Dimensions

Model Width Height Depth Frame (G)
Overall (A) Insert (B) Overall (C) Insert (D) Overall (E) Insert (F)
Colorado 460mm 382mm 605mm 550mm 130mm 75mm 55mm
Ev4i 480mm 382mm 590mm 550mm 145mm 75mm 70mm
Ev4i4 480mm 382mm 620mm 550mm 145mm 75mm 70mm
Ev6i 625mm 382mm 590mm 550mm 145mm 75mm 70mm
Ev6i4 625mm 382mm 645mm 550mm 145mm 75mm 70mm
Kepler 22 645mm 382mm 605mm 550mm 135mm 75mm 60mm
Oberon 515mm 382mm 615mm 550mm 200mm 75mm 125mm
Strellar 515mm 382mm 615mm 550mm 200mm 75mm 125mm
Sphera 475mm 382mm 600mm 550mm 204mm 75mm 50mm
Argenta 16 464mm 382mm 590mm 550mm 127mm 75mm 52mm
Argenta 22 638mm 382mm 605mm 550mm 125mm 75mm 50mm
Topaz 645mm 382mm 605mm 550mm 135mm 75mm 60mm

Removing the Glass

Instructions vary slightly by model series.

For Ev4i, Ev4i4, Ev6i, Ev6i4, Kepler 22, Strellar, Argenta 16, Argenta 22:

  1. Unscrew the two screws and remove the bottom glass retainer from the appliance.
  2. The glass can now be removed from the appliance. To replace the glass, follow the steps in reverse.

For Sphera:

  1. Unscrew the two screws and remove the top plate.
  2. With the top plate removed, slide the glass upwards to remove.

Fuel Sets

Once the appliance is installed and front glass removed, lay out your fuel set as desired. Replace the glass panel by reversing the removal steps.

Fitting the Fascia

Magnets

The following models have a fascia attached with magnets:

Slotted (Models: Oberon, Strellar)

The Oberon and Strellar cast fascia is secured to the front of the appliance with two top-mounted clips and a mounting bracket. Line up the two clips with the top of the mounting bracket and slot them down into the bracket.

The cast frame can now be screwed to the appliance using the 2x screws supplied. Screw holes are located at the lower part of the frame. Once fitted, the fret panel can be fitted in front of this.

Troubleshooting

Applies to: Colorado / Ev4i / Ev4i4 / Ev6i / Ev6i4 / Kepler 22 / Oberon / Strellar / Topaz / Argenta 16 / Argenta 22.

For information on 'Colorado Blower Access & Clean', please refer to the maintenance series videos. (QR codes for external links are excluded).

Report a Fault

If you experience difficulties or problems with your appliance, please contact Evonic Fires for assistance. (QR codes for external links are excluded).

Warranty

Evonic Fires offers a 5-year warranty: 1 year parts & labour + 4 years parts supplied, applicable for products purchased from 1st May 2022. Appliances despatched prior to this date may have a standard 2-year warranty.

To receive your Extended Warranty, the product must be purchased from an authorised stockist and registered with Evonic Fires via the online form at evonicfires.co.uk/register-your-product. The warranty period commences on the date of purchase.

The product must be adequately serviced and maintained. Evonic Fires provides maintenance call-outs at a cost.

During the extended warranty period, only parts supplied or authorised by Evonic Fires can be used for repairs. Contact the service department at service@evonicfires.co.uk or call 01789 263868 for spare parts.

Consumable items (glass, screens, LEDs, filters, power supplies) subject to normal wear and tear or requiring routine maintenance are not covered by the extended warranty but are covered for the first 12 months.

To make a warranty claim, provide evidence (pictures, videos). Failure to supply evidence may invalidate or delay the claim. A service charge applies for engineer visits after the first year. Work carried out by third parties must be approved in advance.

Warranty Exclusions and Limitations

The Evonic Extended Warranty does not cover:

Repaired or replaced products are covered for the remainder of the original warranty period. Claims must be reported within 14 days of fault occurrence. For faults in years 2-5, CK Fires Ltd will send necessary components free of charge.

CK Fires Ltd's total liability is limited to the purchase price paid for the goods, except where prohibited by statute. CK Fires Ltd may choose to replace goods or refund the purchase price. UK law prevails for products sold outside the UK and Ireland. The Evonic Fires Extended Warranty does not affect statutory rights.

Contact Information:

CK Fires Ltd / Evonic Fires
1, Evonic House, Clifford Park, Clifford Lane,
Stratford-on-Avon, CV37 8HW
Tel: +44 (0)1789 263868
Fax: +44 (0)1789 293080
Email: sales@evonicfires.co.uk
Website: www.evonicfires.co.uk

Follow us on: Instagram | Facebook | Twitter | LinkedIn @evonicfires

Models: Ev4i E-Touch Inset Electric Fire, E-Touch Inset Electric Fire, Electric Fire, Ev4i4, Ev6i, Ev6i4

File Info : application/pdf, 30 Pages, 3.52MB

PDF preview unavailable. Download the PDF instead.

Insets-Instruction-Guide-Issue-7

References

Adobe PDF Library 16.0.7 Adobe InDesign 17.2 (Windows)

Related Documents

Preview Evonic Fires Insets Instruction Manual
Comprehensive instruction manual for Evonic Fires Insets, detailing installation, operation, components, troubleshooting, and warranty information for various models including Ev4i, Ev6i, Colorado, Oberon, Strellar, and C1 series.
Preview Evonic Fires Insets Instruction Manual: Installation, Operation & Warranty
Comprehensive instruction manual for Evonic Fires Insets, covering installation guides, operating instructions for manual, remote, and e-smart controls, model dimensions, troubleshooting, and warranty information.
Preview Evonic Fires Insets Instruction Manual
Comprehensive instruction manual for Evonic Fires Insets electric fireplaces, covering installation, operation, app control, troubleshooting, and warranty information.
Preview Evonic Fires Insets Installation Manual
Comprehensive installation manual for Evonic Fires Insets, covering safety, installation procedures, control methods, troubleshooting, and warranty information for various models including Kepler, Colorado, Oberon, Strellar, Topaz, Sphera, Argenta, and e-lectra series.
Preview Evonic Fires Insets Instruction Manual: Installation, Operation & Troubleshooting
This comprehensive instruction manual provides detailed guidance on installing, operating, and troubleshooting Evonic Fires Insets. It includes model dimensions, safety information, warranty details, and E-Touch app instructions.
Preview Evonic Fires Black Edition Inset Installation Manual
Comprehensive installation manual for Evonic Fires Black Edition inset fireplaces. Learn about setup, operation, troubleshooting, and warranty for your new electric fireplace.
Preview Evonic Fires Inset Electric Fire Instruction Guide & Technical Specifications
Comprehensive guide for installing, operating, and troubleshooting Evonic Fires inset electric fireplaces, including models like Colorado, Iowa, Detroit, Memphis, Kansas, and Kepler 22. Features safety, installation, and warranty information.
Preview Evonic Fires Inset Electric Fireplace: Installation, Operation, and Troubleshooting Guide
Comprehensive instruction manual for Evonic Fires inset electric fireplaces, covering installation, operating instructions, safety, technical specifications, troubleshooting, and warranty for models Colorado, Iowa, Detroit, Memphis, Kansas, and Kepler 22.