STIEBEL ELTRON HPA-O 13.1 C Premium
Air-to-Water Heat Pump
Product Overview
The STIEBEL ELTRON HPA-O 13.1 C Premium is a quiet and compact air-to-water heat pump designed for both modernization and new construction projects, focusing on sustainable living comfort. It offers efficient heating and cooling capabilities.
Key Features
- Air-to-water heat pump for heating and cooling, suitable for outdoor installation.
- Environmentally friendly refrigerant with low global warming potential.
- High efficiency and low energy costs due to modern inverter technology.
- Low noise level, ideal for densely built areas.
- "Silent Mode" function for additional noise reduction during nighttime.
- Easy smartphone control (requires additional components).
- Excellent for modernization projects and new, large buildings.
- Supply temperatures up to 65 °C for superior hot water comfort.
- High energy efficiency class A++/A++ even when used with radiators.
HPA-O 13.1 C Premium Unit Image: A visual representation of the outdoor unit of the heat pump.
HPA-O 10.1 C Premium Unit Image: A visual representation of the outdoor unit of the heat pump.
Technical Data
Type | HPA-O 10.1 C Premium | HPA-O 13.1 C Premium |
---|---|---|
Model Number | 206367 | 206368 |
Energy Efficiency Class for Heat Pump W35 (A+++ → D) | A++ | A++ |
Energy Efficiency Class for Heat Pump W55 (A+++ → D) | A++ | A++ |
SCOP 35 °C (EN 14825) | 4.31 | 4.35 |
Heating Output at A7/W35 (EN 14511) | 8.24 kW | 8.24 kW |
Heating Output at A2/W35 (EN 14511) | 7.82 kW | 7.82 kW |
Heating Output at A-7/W35 (EN 14511) | 9.90 kW | 12.34 kW |
Cooling Output at A35/W7 max. | 10.10 kW | 13.91 kW |
Cooling Output at A35/W18, partial load | 8.74 kW | 8.74 kW |
Cooling Output at A35/W18 max. | 13.37 kW | 14.17 kW |
Energy Efficiency Factor at A7/W35 (EN 14511) | 4.61 | 4.61 |
Energy Efficiency Factor at A2/W35 (EN 14511) | 3.82 | 3.82 |
Energy Efficiency Factor at A-7/W35 (EN 14511) | 3.36 | 3.00 |
Cooling Power Factor at A35/W7 max. | 2.33 | 2.27 |
Cooling Power Factor at A35/W18, partial load | 3.46 | 3.46 |
Cooling Power Factor at A35/W18 max. | 2.75 | 2.93 |
Sound Power Level (EN 12102) | 55 dB(A) | 55 dB(A) |
Lower Source Application Limit min. / max. | -20/40 °C | -20/40 °C |
Heating Application Limit max. | 65 °C | 65 °C |
Height | 1045 mm | 1045 mm |
Width | 1490 mm | 1490 mm |
Depth | 593 mm | 593 mm |
Mass | 175 kg | 175 kg |
Compressor Rated Voltage | 400 V | 400 V |
Emergency/Additional Electric Heater Rated Voltage | 400 V | 400 V |
Refrigerant | R452 B | R452 B |
Color | White | White |
Distributors
Our local distributors can provide necessary information.
Find a Distributor: www.stiebel-eltron.pl/pl/info/znajdz-dystrybutora.html
Installation
Installation of units that are not ready for connection must be performed by a qualified installer or an authorized service company.