Foreword

Thanks for purchasing the Comica EJoy D10 Pro.

Main Features

Important Notices

Wired Mode (XLR Output): When outputting analog audio through the XLR port, other functions like status indicator light, EQ, gain adjustment, RGB light, and real-time monitoring are unavailable, only audio signal is delivered.

Version Compatibility: The one-channel version is not compatible with the two-channel version. The one-channel version supports stereo monitoring, while the two-channel version does not (both versions are mono output).

Computer Connection (Microphone TX): When connecting the mic to a computer, select "Comica_EJoy D10 Pro TX" as the output and input device in sound settings.

Computer Connection (Receiver RX): When connecting the receiver to a computer, select "Comica_EJoy D10 Pro RX" as the output and input device in sound settings.

Gain Adjustment: If input volume is too loud when connected to a computer, adjust the computer's "Microphone Properties-Levels" to reduce gain (Windows example shown).

Microphone Placement: Aim the microphone capsule at the sound source for optimal recording.

Environmental Precautions:

Regulatory Compliance: EJoy D10 Pro has type certification according to Japan Radio Law Article 38-24(1).

Packing List

EJoy D10 Pro(A) (One-channel Version)

EJoy D10 Pro(D) (One-channel Version)

EJoy D10 Pro(A) COMBO (Dual-channel Version)

EJoy D10 Pro(D) COMBO (Dual-channel Version)

Components and Instruction

Microphone (TX)

Components:

Component Details:

Installation and Usage

Boom Arm Kit Installation

  1. Clamp the boom arm base onto the desktop and tighten the bottom screw clockwise to secure it.
  2. Insert the boom arm into the base socket. Use the screws on the side of the base to fix and adjust the arm's angle.
  3. Connect the microphone's threaded hole to the boom arm's screw, rotating clockwise to fasten.
  4. Adjust and fix the microphone's position using the locking knob on the boom arm.

Desktop Stand Kit Installation

  1. Connect the microphone's threaded hole to the screw of the desktop mic stand, rotating clockwise to fasten.
  2. Adjust the microphone's angle using the locking knob on the microphone.

Usage

Wired Mode

1. Digital Output

Connect the microphone to a smartphone or computer using the audio output cable. Choose whether to monitor the audio based on your needs.

Note: When connecting to Lightning port devices, please purchase a USB C-Lightning adapter/cable that supports OTG function.

The microphone automatically turns on when connected to a device and powers off after 10 minutes of disconnection.

2. Analog Output

Connect the microphone to an audio interface, recorder, or mixer using an XLR-XLR or XLR-3.5mm TRS audio cable.

Note: When using the XLR port for analog audio output, functions like status indicator light, EQ, gain adjustment, RGB light, and real-time monitoring are unavailable, only the audio signal is transmitted.

Please purchase the appropriate XLR-XLR or XLR-3.5mm TRS audio cable separately if connecting to XLR interface devices.

The microphone automatically turns on when connected to a device and powers off after 10 minutes of disconnection.

Wireless Mode

Pairing

The microphone and receiver are paired by default. If re-pairing is necessary:

  1. Turn on the microphone (TX). Simultaneously long press the EQ Effect Button and RGB Light Button to enter pairing status.
  2. Connect the receiver (RX) to a device to establish a wireless connection. After successful pairing, the microphone's (TX) status indicator light will remain solid blue.

Pairing Indicator Status:

Troubleshooting: If pairing fails on some mobile phones (e.g., HUAWEI, OPPO), ensure the phone's OTG function is enabled (most phones have it enabled by default).

Usage (Connecting Receiver

Refer to the connection diagrams for connecting the receiver to various devices (smartphones, laptops, desktops).

Note: When connecting to Lightning port devices, please purchase a USB C-Lightning adapter/cable that supports OTG function.

Specifications

Transmitting Power +10dBm
Reception Sensitivity -97dBm
Antenna Type Ceramic Antenna
Wireless Delay <20ms
Type Dynamic
Directivity Cardioid
Microphone Sensitivity -56dB re 1V/Pa(1.6mV @ 94dB SPL) ±2dB @ 1kHz
Frequency Range 55Hz ~ 16kHz
Maximum SPL 128dB (@ 1% THD)
Signal / Noise 72dB SPL(A-weighted, as per IEC651)
Equivalent Noise 22dB SPL(A-weighted, as per IEC651)
Dynamic Range 106dB SPL(A-weighted, as per IEC651)
Sampling Rate 48kHz
Bit Depth Microphone Recording: 24-bit; Headphone Monitoring: 16-bit
Digital Output Interface USB-C
Analog Output Interface XLR 3-pin
Monitoring Interface 3.5mm TRS/TRRS
Battery Type Lithium Polymer 930mAh 3.7V
Standby Time RGB off: 45 hours; RGB on: 25 hours
Net Weight Microphone Body: 228g; RX: 3.3g
Dimension Microphone Body: Φ56mm x L160mm; RX: 32.7 x 15.5 x 7mm
Operating Temperature 0℃~+50℃
Storage Temperature -20℃~+60℃

Contact and Support

Website: comica-audio.com

Social Media:

Email: support@comica-audio.com

Phone: 400-8303-981

COMICA is a registered trademark owned by Commlite Tech Co., Ltd.

Models: D10 PRO, EJoy D10 PRO RGB Cardioid Dynamic Wireless Microphone, EJoy D10 PRO, RGB Cardioid Dynamic Wireless Microphone, Cardioid Dynamic Wireless Microphone, Dynamic Wireless Microphone, Wireless Microphone, Microphone

File Info : application/pdf, 36 Pages, 8.92MB

PDF preview unavailable. Download the PDF instead.

202502121439129642 Adobe PDF library 17.00 Adobe Illustrator 27.5 (Windows)

Related Documents

Preview Comica EJoy D10 RGB Cardioid Dynamic Microphone User Manual
User manual for the Comica EJoy D10, a professional RGB cardioid dynamic microphone. Learn about its features, installation, usage, and technical specifications.
Preview Comica EJoy D10 PRO RGB Dynamic Wireless Microphone User Manual
Comprehensive user manual for the Comica EJoy D10 PRO RGB dynamic wireless microphone, covering features, specifications, setup, and usage in wired and wireless modes.
Preview Comica EJoy D10 RGB Dynamic Microphone User Manual
User manual for the Comica EJoy D10 RGB unidirectional dynamic microphone, detailing features, specifications, setup, and usage for both digital and analog outputs.
Preview COMICA STM-USB USB Condenser Cardioid Microphone User Manual
Comprehensive user manual for the COMICA STM-USB, a versatile USB condenser cardioid microphone for studio quality audio, live streaming, and recording. Features include gain control, mute function, real-time monitoring, and multiple pickup patterns.
Preview Comica CVM-SV20 Stereo Condenser Shotgun Video Microphone User Manual
User manual for the Comica CVM-SV20, a professional stereo condenser shotgun video microphone designed for cameras, camcorders, and smartphones. Features include all-aluminum construction, super anti-interference, and adjustable sensitivity.
Preview COMICA VM10 PRO Mini Cardioid Digital Shotgun Microphone User Manual
Comprehensive user manual for the COMICA VM10 PRO, a mini cardioid digital shotgun microphone. Learn about its features, installation, and specifications for professional audio recording.
Preview Comica Vimo Q User Manual: Four-Channel Mini Wireless Microphone System
Comprehensive user manual for the Comica Vimo Q, a four-channel mini wireless microphone system. Learn about its features, setup, operation, and specifications for professional audio recording with cameras, smartphones, and PCs.
Preview COMICA BoomX-D MI 2.4G Digital Dual-Channel Wireless Microphone User Manual
User manual for the COMICA BoomX-D MI, a 2.4G digital dual-channel wireless microphone system. This guide covers features, components, installation, usage, pairing, and specifications for optimal audio capture.