Assembly Instruction

speakON® | Loudspeaker Cable Connector

NL2FXX-W-* & NL4FXX-W-*

Important Safety Information

⚠️ ATTENTION: speakON® is not to be used as an AC mains or power supply connector!

❗ CAUTION: Connector not to be engaged and disengaged in normal used when live or under load.

⚠️ ATTENTION: NE PAS UTILISER POUR COUPER LE COURANT

PRODUCT IS INTENDED FOR FACTORY ASSEMBLY ONLY

Approval Based

EN/IECUL/CSA
ApprovalEN 61984
IEC 61984
UL 1977
CAN/CSA C22.2 No.182.3
Rating250 V ac / 30 A250 V ac / 30 A
Wire size1.0 - 4.0 mm²16 - 11 AWG
Cable O.D.6.0 - 12.0 mm (0.24 - 0.47")6.0 - 12.0 mm (0.24 - 0.47")
*-S:10.0 - 16.0 mm (0.39 - 0.63")10.0 - 16.0 mm (0.39 - 0.63")
*-L:

Assembly Information

Step A: Cable Preparation

Place the bushing (1) and chuck (2) over the cable. Important: Chuck and Bushing cannot be placed over the cable after the assembly or the insert.

Step B: Cable Preparation

Prepare the cable as shown. For 2-pole connectors, strip 27 mm [1.06"] of the outer jacket and 9 mm [0.35"] of the inner conductors. For 4-pole connectors, strip 27 mm [1.06"] of the outer jacket and 9 mm [0.35"] of the inner conductors.

Step C: Wiring and Clamping

Slide the cable into the contacts and clamp. For 2-pole wiring, connect to terminals 1+ and 1-. For 4-pole wiring, connect to terminals 1+, 1-, 2+, and 2-.

Torque Value: 0.7 Nm (6.2 inch-pounds) using a T8 Torx size bit.

Step D: Chuck and Insert Assembly

Position chuck (1) on insert (2).

Step E: Housing Assembly

Slide insert (2) with chuck (1) together into housing (3). Important: Align the chuck by positioning the nose into the keyway. Slide bushing (4) over chuck (1).

Step F: Final Tightening

Hold the connector with the Neutrik tool (5) HTLACA and tighten the bushing with the Neutrik tool (6) HTLACB. For an exact mounting position, use a torque wrench with a 27 mm (1 1/8 inch) hex bit (7) and tighten it to 2.5 Nm (22 inch-pounds / 1.8 lb-ft).

Finished Connector

The finished connectors are the NL2FXX-W-* and NL4FXX-W-* models.

Disassembly Information

For Disassembly:

  1. Use the Neutrik tool HTLACB.
  2. Position the tool on the surfaces and open the clamping sleeve.

Safety Information

❗ CAUTION: To ensure protection category, do not expose the connection to bending forces (e.g., do not attach loads to the cable, no free-dangling cable windings etc.).

⚠️ SAFETY WARNING: For safety and certification reasons, the connector must be replaced in case of any broken parts or excessive wear and tear.

More Information

For more information, visit www.neutrik.com/products/audio/speakon.

Models: NL2FXX-W, NL4FXX-W, NL2FXX-W Loudspeaker Cable Connector, NL2FXX-W, Loudspeaker Cable Connector, Cable Connector, Connector

File Info : application/pdf, 3 Pages, 5.88MB

PDF preview unavailable. Download the PDF instead.

563043 bda 638 v2 speakon nl2fxx w

References

Acrobat Distiller 22.0 (Windows)

Related Documents

Preview Neutrik NL2FXX-W-S speakON Cable Connector: Features & Technical Specifications
Neutrik NL2FXX-W-S speakON cable connector. This 2-pole connector offers industry-standard reliability for loudspeaker connections with a robust twist-lock system, screw terminals, and chuck type strain relief for cables 6-12mm. Features include high current rating, IEC certification, and durable materials.
Preview Neutrik speakON NEU-NL2FXX-W-S Assembly Instructions
Detailed assembly and disassembly instructions for the Neutrik speakON NEU-NL2FXX-W-S loudspeaker cable connector, including safety information and technical specifications.
Preview Neutrik speakON NL4MP-ST Chassis Connector Assembly Instructions
Assembly instructions for the Neutrik speakON NL4MP-ST chassis connector, detailing connection, wiring, panel cutout, and mounting specifications.
Preview Neutrik TRUE1 2+PE powerCON Connector (Male) NT-NAC3M-TRUE1-S Specifications
Detailed specifications for the Neutrik TRUE1 2+PE powerCON Connector (Male), model NT-NAC3M-TRUE1-S. Features include heavy-duty sealed design, UV resistance, IP65/IP67 rating, and breaking capacity (CBC). Covers physical, electrical, mechanical, and environmental characteristics.
Preview Neutrik NC5FBH1-B Connector: Technical Drawing and Specifications
Detailed technical drawing and specifications for the Neutrik NC5FBH1-B connector, including panel cutout dimensions, PCB layout, and assembly information. Features a push-button mechanism.
Preview Neutrik NC3MBH-1 XLR Connector Technical Specifications and Panel Mount Dimensions
Detailed technical specifications and panel cutout dimensions for the Neutrik NC3MBH-1 XLR connector, including layout tolerances and PCB mounting information.
Preview Neutrik powerCON TRUE1 TOP NAC3FX-W-TOP-L Cable Connector Product Manual
Detailed product manual for the Neutrik powerCON TRUE1 TOP NAC3FX-W-TOP-L appliance coupler, covering application instructions, assembly, disassembly, safety guidelines, and technical specifications.
Preview Neutrik powerCON NAC3FXXA-W & NAC3FXXB-W Assembly and Safety Instructions
Comprehensive guide for the assembly, usage, and safety precautions for Neutrik's powerCON locking 3-pole power connectors, models NAC3FXXA-W and NAC3FXXB-W. Includes technical specifications, cable compatibility, and disassembly information.