Welcome!
This guide will walk you through step-by-step how to install and get Lockly Guard™ up and running. Installation generally takes less than 30 minutes. If you have any questions please call our VIP hotline (855) 562-5599 for help.
Reference installation parts overview foldout on back page.
Preparation
To complete the installation you will need:
- Phillips Screwdriver (+)
- Flathead Screwdriver (-)
- Tape measure or ruler
Optional:
- Screwdriver with drill bits
- Pliers
Drilling may be required to install this lock. If you are installing your lock on a brand new door, a drill is required if there are no holes prepared for lock installation. Use provided template to bore holes on door.
Preparation continued
Remove existing door hardware, latch or deadbolts before installing the new lock. Use provided template to bore new holes if needed.
- Measure and confirm your door is between 1-3/8" - 2" (35mm - 50mm).
- Measure and confirm the hole in the door is 2-1/8" (54mm).
- Measure and confirm that the backset is between 2-3/8" (60mm) to 2-3/4" (70mm).
- Measure and confirm that hole in the door edge is 1" (25mm).
- Measure and confirm that distance between front door holes is 4" (101.6mm) or 5.5" (139.7mm).
IMPORTANT NOTICE: Use goggles to protect eyes if you need to drill door holes.
Step 1: Installing the Lockset
Measure the distance between center of front door hole to the edge of your door hole to determine the backset. Adjust latchbolt F and deadbolt J according to the backset of your door.
Deadbolt Adjustment J
- I. Push the crank (a) to extend the deadbolt (b).
- II. Hold the metal plate (c) and twist the deadbolt body (d) clockwise till it snaps to 2-3/8".
- III. To return to default status, while the deadbolt (b) is extended, hold the metal plate (c) and twist the deadbolt body (d) counter-clockwise till it snaps to 2-3/4".
Latchbolt Adjustment F
Push the shaft (a) to adjust the lockset to 2-3/8" (60mm) or 2-3/4" (70mm).
Note: the shaft's horizontal and vertical alignment must be sustained during installation to ensure latch will fully extend and lock securely.
Step 1 continued: Installing the Lockset
After adjusting the latchbolt F, determine the orientation of the latchbolt. Facing the door exterior, install the latchbolt according to the opening direction of your door.
Left Out-Swing Door
Right Out-Swing Door
Left In-Swing Door
Right In-Swing Door
Install deadbolt (top) and latchbolt F (bottom) to door and secure with screws K and G. Retract deadbolt, make sure bore hole is horizontally positioned and the spindle shaft is centered.
Available parts for mortise slot: PGA018, PGA019, PGA019S.
Optional: Stainless steel mortise slot cover, 4" or 5.5" Face Plates available. To purchase, please call our Customer Service hotline (855) 562-5599 or email prosales@lockly.com.
Step 2: Changing Handle for Right or Left Swing Doors
The lock ships with handle default for right in-swing or left out-swing door. Check the diagram below if you are unsure of your door orientation.
Door Orientation Diagram:
- Right In-Swing Door
- Left Out-Swing Door
- Left In-Swing Door
- Right Out-Swing Door
No need to change door handle orientation. Skip Step 2.
LEFT-IN SWING and RIGHT OUT-SWING DOORS require changing the door handle orientation. Continue to follow Step 2 to change exterior and interior door handle orientation.
Changing the Exterior Handle Orientation
- Insert key and rotate so that the two white dots align as shown.
- Use the provided pin insert R to push the metal pin located at the 3 o'clock of the base handle, then the other pin at 9 o'clock position. Remove the handle once the pins are compressed.
- Rotate the handle 180° to the other side of the lock.
- Confirm that your installation was complete by checking if the pins are flush against the handle, and has popped out. Adjust the handle accordingly to make sure the pins are fully decompressed and sits flush against the surface.
- Check that your handle works smoothly by giving it a turn up and down.
- Twist key back to horizontal position. The key can be taken out once it goes back to the horizontal position.
- At the back of the exterior assembly, remove the screw on point "R".
- Align the screw hole on point "L" then insert the removed screw and tighten.
Changing the Interior Handle Orientation
- Remove the handle retaining screw and detach the handle. Rotate the handle 180° as shown.
- Insert the handle retaining screw and tighten using a screwdriver.
Step 3: Preparing Lock for Installation
Carefully prepare the lock and ensure the required parts (C, D, E) have been properly attached before installing to door.
- Install Spindle C with the holes side into the base of the lock and align the holes locate in the 3 o'clock and 9 o'clock position.
- Insert locking pin D in to the hole as shown above.
- Carefully bend the end of the locking pin D with a needle nose pliers. Failure to bend the locking pin and turn the handle freely without obstruction will result to malfunction.
- Slotted Barrel Extension E should be installed according to upper door hole distance to the bottom door hole (4" or 5.5"). Use a flathead screwdriver to secure tighten E clockwise.
Step 4: Installing the Lock (Exterior)
- Install fire shield N1 as shown.
- Use a screwdriver to secure the cables in the fire hood. Ensure that the cables are routed out of the U-shaped slot and the fire hood does not press cables.
- Pull the connecting wire in the direction of the arrow.
- Install the fire shield N2 on the outside of the door, on the deadbolt J.
- While aligning the lock straight up-and-down, pass the wiring cable under the latchbolt F then ensure the Slotted Barrel Extension E passes through the hole on the lower part of the deadbolt body J as shown.
- Ensure E is securely installed on the correct position, then insert E to top door hole, passing through below part J.
- Pass the spindle C through the center of the latchbolt, and the round rods through the sides in their respective holes. The cable should run underneath the lockset.
- Check lock alignment and ensure that it is sitting flat and aligned straight.
Step 5: Installing Interconnection Plate Gear
- Select interior cover plate U1 or U2 according to door hole distance and install on to door. (4" use cover plate U1, 5.5" use cover plate U2)
- Insert Positioning Rods V into the holes to the left and right of the Spindle C. The holes are located at the 3 o'clock and 9 o'clock positions.
- Install fire shield N1 as shown. Ensure that the cables are routed out of the U-shaped slot and the fire hood does not press cables.
- Ensure the rods on interior cover plate U1 or U2 is inserted on the holes of the deadbolt, and the cable and spindle C passed through part U.
- Secure interior cover plate U with screws V and replace them with screws O. Tighten clockwise until the mounting plate is secure. (Use O1 or O2 screw for 5.5" and 4" respectively).
- Select the side of the interconnection gear P according to door handle orientation Left or Right. Insert torque blade AD to plate according the distance between the latchbolt and deadbolt. You may strike AD with pliers to insert it to 4" or 5.5" hole.
Select the correct side of the interconnection gear:
- For right swing door: The R side should be facing in front of you after inserting the torque blade.
- For left swing door: The L side should be facing in front of you after inserting the torque blade.
- Install interconnection plate P onto door. Ensure the torque blade AD is inserted horizontally to the deadbolt. The spindle must pass through the plate. Secure the plate with screws M (x3).
Step 6: Installing Interior Assembly (N)
- Connect cable A1 to A2 by hand. Plug B1 into B2, match red side of plug with red on socket - insert tightly. Secure the lock interior with 3 screws AE.
- Align the spindle C to the lock interior and attach the Interior lock to the interconnection plate. Gently push some of the excess cable through the rectangular hole into the door. Place the remaining cable inside the interior assembly and ensure it sits securely onto the interconnection plate gear. Make sure the cable is away and not tangling with the spindle C.
IMPORTANT: If you need to disconnect this cable, use a screwdriver to hold down the tab before carefully unplugging. DO NOT FORCE as this may result in damaging the lock.
- Insert 8 AA batteries into the lock by aligning the positive (+) and negative (-) markings on the batteries to the battery chamber.
- Secure the battery by sliding the cover Q over the lock and turning the screw clockwise on top until tight.
Step 7: Preparing Door Sensor for Installation
Do not mount (install) door sensors yet. You will install in step 9.
About door sensors
Door sensors provide real-time door condition status, such as the ability to verify if the door is securely closed. It also sends push notifications to your phone whenever your door opens and enables voice control.
Lockly Guard™ Vision Duo (698D) comes with a pre-wired door sensors consisting of two parts: Part AA - Wired Sensor and Part AB - Sensor Magnet.
IMPORTANT: Gap must be less than 3/4" when installed. When installed on door, the distance between the wired sensor and sensor magnet must be less than 3/4" in order for the sensor to work. If door frame is higher than door, add included foam pads to level parts AA and AB with each other as much as possible.
TIP: Lockly door sensors comes in Grey (PGA061) and Matte Black (PGA062) that can be ordered through our customer hotline: (855) 562-5599 or by email: prosales@lockly.com.
Removal of Sensor (optional)
There may be circumstances where the sensor cannot be installed because of molding/door limitations or is not aesthetically desirable. The sensor wired to the lock is removable by carefully pulling its connector from the circuit board. If removed, some features and functionality will not be available, such as real-time condition status.
Step 7 continued: Preparing Door Sensors for Installation
When you are installing the door sensors, make sure the arrow of the wired sensor AA is placed next to the arrow of the sensor magnet AB as close as possible.
LEFT
OR
RIGHT
IMPORTANT: Do not install the sensor close to the strike plate H.
If needed add Foam Pads to level AA & AB as much as possible.
The interior assembly comes with the pre-installed wired door sensor setup for a right/left swing doors with 2-3/4" (70mm) backset*. Trim excess part e for doors with 2-3/8" (60mm) backset as shown below.
*Backset - measure the distance of the door edge to the center of the door hole.
Make sure you install the Door Sensor indoors on a clean and dry surface. Gently wipe the surface of your door and door frame where you wish to install the Door Sensor and make sure it's dry before installing.
Keep the Door Sensor away from direct sunlight, high heat locations and large metal objects that may interfere with wireless signals.
DO NOT INSTALL THE SENSORS YET
Step 8: Installing the Door Strike
It is recommended that you use the included strike plate. However, if you find the deadbolt and latchbolt works with your existing strike plate free of any binding or resistance you can use it. Regardless of which strike plate used, deadbolt and latchbolt needs to operate smoothly, free of any binding or resistance. Adjust appropriately as needed.
IMPORTANT: Check the alignment of the screw holes of both latchbolt and strike. Ensure the latchbolt plunger is against the strike plate H.
Make sure the slanted side of Latchbolt F is closing against the slanted part of Strike Plate H.
Before fixing it on to door frame, check the gap between door and door frame should be less than 4.5mm. Attach AF (2mm) or AG (3mm) to the strike plate L to reduce gap, if necessary.
Step 9: Installing the Doors Sensor
Make sure you have prepared the door sensors for installation according to Step 7.
- Peel off the paper layer of the adhesives from the back of the wired sensor AA.
- Position the wired sensor AA to the edge of the door, avoiding the door strike plate. Attach and secure with the adhesives.
- Close the door. Before you peel off the paper layer of the adhesives from the sensor magnet AB, align the arrow with the wired sensor AA. Install AB on to door frame.
NOTE: The arrows must be aligned or as closed as possible (less than 3/4"). If needed, adjust the position of the sensor magnet using provided foam pads to ensure the Lockly logo blinks red when door opens or closes.
Step 10: Download LocklyPro App & Unique Activation Code
Congratulations! You have completed the Lockly Guard™ Vision Duo (698D) physical lock installation. To complete your setup, download the LocklyPro app from the iOS or Google Play app Store and follow on-screen instructions.
Scan or visit Locklypro.com/app
Additionally, you'll need the Activation Card with unique pre-paired QR code to your lock. The card is located in the packaging that your lock came in. This QR code can also be found at the bottom of Vision Connect Hub. Please keep it in a safe place—this QR code is required to complete the setup and will be required if you lose your smartphone or access code.
KEEP THIS CARD!
IMPORTANT: Make sure your Lockly Guard™ Vision has the latest firmware. Allow updates and follow instructions if prompted. For more info, visit: http://www.locklypro.com/support
NOTE: Power interruption during firmware update may damage the Vision Connect hub. Do not interrupt or turn the power off while firmware update is in progress.
TIPS:
- Remember to register for warranty.
- Allow your mobile phone to receive push notifications.
- Send in-app feedback if you encounter any issues while using the App.
- If you are having difficulty scanning the QR code, we're here to help. Call our customer care team: (855) 562-5599, or visit http://locklypro.com/support for suggestions and troubleshooting tips.
Step 11: Setting the Vision Connect Hub
The Vision Connect Hub connects directly to your Wi-Fi router using the provided LAN cable. Choose an appropriate location for the hub for optimum performance (see below). For optimum connectivity, it is recommended to set up the hub LESS than 100 feet (30 meters) away from the lock, and elevated 3 feet (1 meter) off the ground.
During the setup process position yourself between the lock and the Vision Connect hub—ideally no more than 100 feet (30 meters) apart. Ensure your iOS or Android™ device has both Bluetooth® and Wi-Fi enabled.
TIP: Sometimes distances between hub and lock can vary due to circumstances. If you are having difficulty setting up optimal range of 100/ft or less, we're here to help. Call our customer care team: (855) 562-5599 or by email: prosales@lockly.com, or visit http://locklypro.com/support for suggestions and troubleshooting tips.
Vision Connect Overview
Plug the Wi-Fi Hub into the 5V 1A USB AC adapter and plug the AC adapter to your wall socket.
To enable video doorbell, live monitoring and voice control with Hey Google, you will need to setup the included Vision Connect Wi-Fi hub with the Lockly Guard™ deadbolt smart lock + video doorbell.
Once you have confirmed that your Wi-Fi Hub is ready to connect to your lock, open the LocklyPro App from your smartphone. Make sure you are standing between the Wi-Fi hub and Lockly Guard smart lock, then Add New Device and follow the on screen instructions.
IMPORTANT: Vision Connect stores recorded video on the included TF card. Although the TF card is discrete, it is recommended to locate it in a discrete or secure area to protect your privacy and video recordings.
Ensure the TF card that comes with Vision Connect is properly inserted.
Connect LAN cable to closest Wi-Fi router to the Lockly Guard™ lock (<100ft).
Always keep the Antenna on UP position.
Connect power cable and plug USB power adapter into outlet.
Wait 2 minutes for hub to self calibrate. Once LEDs turn RED and blink yellow.
Vision Connect is now ready to connect to your iOS or Android™ device.
See troubleshooting on next page if LEDs do not meet the described conditions.
Step 12: Pair Lockly Guard™ Vision Lock to App
Launch the LocklyPro App and select "add a new device", then select Lockly Guard™ Vision Duo (698D). You will be prompted to scan the QR code from the Activation Card or Vision Connect Hub (located at the bottom).
IMPORTANT: Make sure your Lockly Guard™ Vision has the latest firmware. Allow updates and follow instructions if prompted. For more info, visit: http://www.locklypro.com/support
NOTE: Power interruption during firmware update may damage the Vision Connect hub. Do not interrupt or turn the power off while firmware update is in progress.
TIPS:
- Remember to register for warranty.
- Allow your mobile phone to receive push notifications.
- Send in-app feedback if you encounter any issues while using the App.
- If you are having difficulty scanning the QR code, we're here to help. Call our customer care team: (855) 562-5599, or visit http://locklypro.com/support for suggestions and troubleshooting tips.
Step 13: Vision Connect Status & Troubleshooting
LED INDICATORS
HUB | STATUS | |
---|---|---|
Solid red ON | After connecting LAN cable and power adapter, wait for 2mins for Vision Connect to self calibrate. | Power ON/ Successfully paired |
Yellow slow blinking | READY TO CONNECT | Network connected |
If you experience any of the following, power down and disconnect hub, repeat connection process:
During Setup
LED INDICATORS | HUB | STATUS |
---|---|---|
Red slow blinking | Pairing / Network NOT yet connected |
|
Red fast blinking | Pairing unsuccessful | |
Yellow OFF | Router or LAN cable issue NO network connection |
|
Blinking red goes to blue, then turns OFF | Resetting |
During Firmware Update
LED INDICATORS | HUB | STATUS |
---|---|---|
Blue slow blinking | Update in progress* | |
Blue ON | Update Successful | |
Blinking from red to blue | Update has failed |
*Power interruption during firmware update may damage the Vision Connect hub. Do not interrupt or turn the power off while firmware update is in progress.
Step 14: Connecting Your Lockly Guard™ Vision Duo (698D)
The App will take you through the following steps, make sure the smart lock has been properly installed. You will need your activation card that is included in the box to proceed.
ADD NEW DEVICE
Select A Device
Connect Vision Connect Hub
1. Connect power supply to Vision Connect hub.
2. Connect network cable to router.
3. When Vision Connect is successfully connected to the router, the LED light will be flashing yellow.
4. When Vision Connect is connected to the Internet, the LED light will be solid red.
Find the Activation Card
Scan the QR Code
Scan the QR Code
5. Find the Activation Card in the package box.
6. Ensure the battery of LOCKLY Vision is full, scan the QR code from the Activation Card or Vision Connect Hub (located at the bottom).
If you can't scan LOCK SERIAL, Then enter manually
Input Activation Code
Set the Admin Code
Please set the Administrator Access Code. This is the code to unlock your LOCKLY. Use 6-8 digit code.
Match Admin Code
Confirm your Admin Code by entering your code into the keypad below. Press any button that includes the number you need.
Successfully Connected
Please name this device so that you can easily recognize it in the future.
Congratulations! Your Lockly Guard™ Vision Duo (698D) is now - set up.
You may proceed to Add the Door Sensors.
FCC Warning:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. It should be installed and operated with minimum distance 20cm between the radiator & your body.
IC WARNING
This equipment contains licence-exempt transmitter(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions:
- (1) This device may not cause interference.
- (2) This device must accept any interference, including interference that may cause undesired operation of the device.
L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes:
- L'appareil ne doit pas produire de brouillage;
- L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
IC Radiation Exposure Statement
This equipment meets the exemption from the routine evaluation limits in section 2.5 of RSS-102. It should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body.
Cet équipement est conforme à l'exemption des limites d'évaluation habituelle de la section 2.5 de la norme RSS-102. Il doit être installé et utilisé à une distance minimale de 20 cm entre le radiateur et toute partie de votre corps.
WARNING: This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov.
Installation Overview & Parts List
This lock can be installed for both right swing and left swing doors. The lock ships ready for a right swing door installation. If you wish to change the orientation of the lock for a Left Swing door, follow instructions on Installation Guide (Step 2).
Part List:
- Battery Cover (Q)
- Interior Assembly (X)
- Interconnection Plate (P)
- Torque Blade (AD)
- Interior Cover Plate (U1 4" / U2 5.5")
- Latch (F)
- Latchbolt Strike Plate (H)
- Wired Sensor (AA)
- Sensor Magnet (AB)
- Deadbolt (J)
- Fire Shield (N1, N2)
- Slotted Barrel Extension (E)
- Exterior Assembly (B)
- Touchscreen Cover (PGA717) (N)
- Spindle (C)
- Locking Pin (D)
- Clamping Tool (R)
- Positioning Rod For installing mounting plate (U)
- Keys (S)
- Vision Connect Hub (Y)
- TF Card (T)
- Power Adapter (Z)
- Power Plug (Y1)
- Activation Card (W)
- Doorbell Decal (B1, B2)
- Foam Pads
- Strike Plate Spacer (optional)
- Guests and Deliveries Please Ring Doorbell on Door Lock
Screws:
- BM4 x 24MM Screw (AE) (3x)
- PM5 Screw (M) (3x)
- KM4 Screw (3x)
- KA4 x 20MM Screw (K) (4x)
- ST5 x 70MM Screw (K1) (2x)
Screw sizes for door thickness:
- O1: KM4 x 25mm, for door thickness, 1-3/8"~1-2/3" (35~43mm)
- O2: KM4 x 32mm, for door thickness, 1-2/3"~2" (43~50mm)
Measurements for backset:
- 2-3/8" (60mm)
- 2-3/4" (70mm)
IMPORTANT NOTES
- Lockly Guard installs differently from other door locks. Professional installer(s) and locksmiths must read and follow Lockly Guard installation and user manuals to prevent damaging the product. Failure to do so may also result in the smart lock not responding correctly to lock and unlocking commands and will require re-installation.
- This product is recommended for residential use. Please check your office building or property management policies and regulations before installation.
DO NOT RETURN to the stores. Please call our customer care team: (855) 562-5599 to help you with any issues or concerns you might have.
Contact Information
We're here to help!
Email: prosales@lockly.com
Support: locklypro.com/support
© Copyright 2022 Lockly All rights reserved
Patent Information: US Patent NO. US 9,881,146 B2 | US Patent NO. US 9,853,815 B2 | US Patent NO. US 9,875,350 B2 | US Patent NO. US 9,665,706 B2 | US Patent NO. US 11,010,463 B2 | AU Patent NO. 2013403169 | AU Patent NO. 2014391959 | AU Patent NO. 2016412123 | UK Patent NO. EP3059689B1 | UK Patent NO. EP3176722B1 | Other Patents Pending
The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc., and any use of such marks by Lockly is under license. Other trademarks and trade names are those of their respective owners. Google, Android and Google Play are trademarks of Google LLC.
Model Number: PGD698D
File Info : application/pdf, 41 Pages, 6.29MB
DocumentDocumentReferences
Adobe Illustrator 24.1 (Windows) Adobe PDF library 15.00Related Documents
![]() |
Lockly Guard Duo Faceplate - Unified Door Hardware Discover the Lockly Guard Duo Faceplate, an optional accessory designed to enhance the aesthetic of your Lockly Guard Duo, Vision Duo, and Lux Compact smart locks. This faceplate unifies the look of interconnected deadbolts and latches, and can conceal pre-existing door frame holes for a cleaner installation. |
![]() |
Lockly Guard Smart Lock User Manual and Z-Wave Module Guide Comprehensive user manual for the Lockly Guard smart lock (models 679L, 679D) and its Z-Wave module. Covers features, operation, installation, maintenance, safety, and Z-Wave integration. |
![]() |
Lockly Guard Defender Smart Lock User Manual (238LM/238LE) Comprehensive user manual for the Lockly Guard Defender smart lock (models 238LM/238LE), covering installation, setup, features, locking/unlocking methods, troubleshooting, and safety precautions. |
![]() |
Lockly Vision Smart Lock & Video Doorbell Installation Guide Get started with your Lockly Vision smart lock and video doorbell. This guide provides step-by-step installation instructions and information on using the Lockly app and BILT interactive instructions. |
![]() |
Lockly Vision Elite Deadbolt Edition: Installation Guide Comprehensive installation guide for the Lockly Vision Elite Deadbolt Edition smart lock, covering preparation, step-by-step installation, hub setup, app pairing, and troubleshooting. |
![]() |
Lockly Vision Elite Deadbolt Edition Installation Guide Step-by-step installation guide for the Lockly Vision Elite Deadbolt Edition smart lock, covering preparation, installation steps, hub setup, app configuration, and troubleshooting. |
![]() |
Lockly Vision Smart Lock + Video Doorbell User Manual Comprehensive user manual for the Lockly Vision Deadbolt Edition smart lock and video doorbell, detailing features, setup, operation, and troubleshooting for enhanced home security. |
![]() |
Lockly Guard Deadbolt User Manual: PGD728F ZU & PGD728 ZU Comprehensive user manual for the Lockly Guard Deadbolt smart lock, covering installation, features like PIN Genie keypad, Z-Wave integration, fingerprint recognition, access codes, and troubleshooting for models PGD728F ZU and PGD728 ZU. |