Eminere, Eminere MC, Eminere Remote, Eminere Remote MC, Eminere Inground

Repairing Procedure for Loss of Calibration Values for White Colours (Channel CTC)

For service purposes only!

  1. Switch the calibrated Eminere to DMX mode 3 (12 channels).
  2. Send a DMX data packet with data for CTC that meets the calibrated colour:
    • 1800K = 21 CTC
    • 2700K = 66 CTC
    • 3200K = 91 CTC
    • 4200K = 141 CTC
    • 5600K = 211 CTC
    • 6500K = 255 CTC
    It is recommended to also send RGBW values and a Dimmer value to ensure the Eminere responds.
  3. Read the calibrated Eminere in the RDM Manager. The calibration values are stored as 4 bytes in the "LED calibration 4 bytes HEX! (RGBW/RGBA)" field within the "Manufacturer PIDs" section. These values are read from the first processor. (Refer to the accompanying software interface description below).

    Software Interface Description: The RDM Manager software interface is displayed, showing various device control and information panels. Key sections include "Product information" detailing device model and software versions, "DMX512 setup" for DMX addressing, and "El Manufacturer PIDs". The "El Manufacturer PIDs" section contains specific parameters managed by the manufacturer. Within this section, the field labeled "LED calibration 4 bytes HEX! (RGBW/RGBA)" is highlighted by a red bounding box. This field displays the current calibration data for the LED channels, shown as hexadecimal values such as "ff 88 00 08". The procedure instructs users to read and write values to this specific field.

  4. Enter the calibration values (factory values for each fixture) and save them to the Eminere using the save action ▶️. It is possible that both halves of the Eminere lights display different colours during this process. If the colour beam from the Eminere does not change after saving, try modifying one byte of the calibration values, save it, and then revert it to the correct value and save again. If the colour beam still does not change, it indicates that an incorrect CTC value was likely set in the DMX data packet. If the correct CTC colour is not set, the field "LED calibration 4 bytes HEX! (RGBW/RGBA)" will display "FF FF FF FF", and saving the calibration values to the Eminere will fail.
  5. Go to step 2, set a different CTC colour, and repeat steps 3 and 4.

Version 1.0

Date: 12.12.2023

Anolis
A ROBE Business

Models: Eminere MC Remote LED Lighting, Eminere MC, Remote LED Lighting, LED Lighting, Lighting

PDF preview unavailable. Download the PDF instead.

Restoration Of Calibration Values Eminere Microsoft: Print To PDF

Related Documents

Preview Anolis Eminere LED Fixture User Manual
Comprehensive user manual for the Anolis Eminere series of LED lighting fixtures, covering installation, technical specifications, maintenance, and safety instructions.
Preview Anolis Eminere Series LED Lighting Fixture User Manual
Comprehensive user manual for the Anolis Eminere series of LED lighting fixtures (Eminere 1, 2, 3, 4). Covers safety, installation, technical specifications, connections, booster box usage, maintenance, and accessories.
Preview ANOLIS Eminere Remote UV 2 & 4 User Manual
User manual for ANOLIS Eminere Remote UV 2 and UV 4 professional UV LED lighting fixtures. Covers installation, safety, technical specifications, and maintenance for optimal use.
Preview Anolis E-box Remote User Manual
Comprehensive user manual for the Anolis E-box Remote, covering installation, safety, operation modes, menu navigation, DMX protocol, software updates, and technical specifications. Designed for professional lighting applications.
Preview Anolis Eminere Cables and Connectors Installation Instructions
Detailed installation instructions for Anolis Eminere cables and connectors, covering locking, unlocking, and assembly procedures for field-installable connectors. Includes wiring diagrams for US and EU color codes.
Preview Anolis AMBIANE HP111 Pendant Remote Installation Instructions
Comprehensive installation guide for the Anolis AMBIANE HP111 Pendant Remote, detailing steps for mounting, control unit setup, power and data cable connections, and hanging wire adjustments. Includes safety warnings and technical specifications.
Preview Anolis Calumma Remote M User Manual: Installation, Specifications, and Operation
Detailed user manual for Anolis Calumma Remote M MC and SC LED lighting fixtures. Includes safety guidelines, installation instructions, connection diagrams, technical specifications, software updates, and DMX protocol details.
Preview Anolis Calumma XS MC/SC User Manual - Installation, Operation, and Specifications
This user manual provides comprehensive instructions for the Anolis Calumma XS MC and Calumma XS SC lighting fixtures, covering installation, safety, technical specifications, software updates, and maintenance. Learn how to operate your professional lighting equipment effectively.