Anolis E-box Remote User Manual

Version 1.6

1. Safety Information

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR E-box Remote! Save it for future reference.

DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT!

  • Make sure that the available voltage is not higher than stated on the fixture.
  • Always disconnect the fixture from AC power before removing its cover.
  • Make sure that the supply cables are not damaged by sharp edges. Check the fixture and the cables from time to time.
  • Do not install the fixture near an open flame.
  • This fixture falls under protection class I. Therefore, this fixture has to be connected to a mains socket outlet with a protective earthing connection.
  • Do not connect this fixture to a dimmer pack.
  • Do not cover the fixture with cloth or other materials.
  • The fixture was designed for outdoor use, and it is intended for professional application only. It is not for household use.
  • When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat or dust.
  • Only operate the fixture after having checked that the housing is firmly closed, and all screws are tightly fastened.
  • Operate the fixture only after having familiarized yourself with its functions. Do not permit operation by persons not qualified to operate the fixture. Most damages are the result of unprofessional operation!
  • Unauthorized modifications on the fixture are forbidden due to safety reasons!
  • Please use the original packaging if the fixture is to be transported.
  • If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the warranty becomes void. Furthermore, any other operation may lead to dangers like short-circuit, burns, electric shock etc.

Immunity of the equipment is designed for electromagnetic environments E1, E2, E3, according to the standard EN55103-2 ed.2 - Electromagnetic compatibility. Product family standard for audio, video, audiovisual and entertainment lighting control apparatus for professional use. Part 2: Immunity.

The product (covers and cables) must not be exposed to a high frequency electromagnetic field higher than 3V/m. The installation company should check levels of possible interferences above the tested levels E1, E2, E3 given by this standard (e.g., transmitters in surrounding area), before installing the equipment.

Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment – Emission Requirements according to class B.

The product (covers and cables) must not be exposed to a high frequency electromagnetic field higher than 3V/m.

2. Fixture Description

The E-box Remote features a robust enclosure with various connection points and controls.

Top View Components:

  • A - Top cover
  • B - Top cover screws
  • C - Mounting holes
  • D - Antenna cover
  • E - Display
  • F - Control buttons
  • G - Screws of terminal blocks cover
  • H - Terminal blocks cover

Port Identification (Numbered):

  • 1 - LED Output 1 (cable gland M20x1.5)
  • 2 - LED Output 2 (cable gland M20x1.5)
  • 3 - Power IN (cable gland M20x1.5)
  • 4 - DMX OUT (cable gland M12x1.5)
  • 5 - DMX IN (cable gland M12x1.5)
  • 6 - Ethernet OUT (cable gland M12x1.5)
  • 7 - Ethernet IN (cable gland M12x1.5)

The unit includes a display (E) and four control buttons (F) for operation. The terminal blocks are accessed after removing the top cover (A) and terminal blocks cover (H).

3. Mounting

Fixture must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.

Setting and addressing the E-box Remote without top cover can be done by a qualified person only!

Note for cable glands:

It is recommended to apply an adequate layer of LOCTITE 5331 paste on the plastic holder of the cable gland and LOCTITE 577 on the thread of the gland body before insertion.

Installation Steps:

  1. Remove the top cover (A) by unscrewing four screws (B) to access the display (E) and control buttons (F).
  2. Fasten the E-box Remote on a non-flammable flat surface using the four mounting holes (C) with a diameter of 7 mm.
  3. Remove the terminal blocks cover (H) by unscrewing four screws (G) to access the terminal blocks.
  4. Remove end caps from cable glands before passing cables. Ensure unused cable glands are covered with end caps to maintain the declared IP rating.
  5. Pass DMX and Ethernet cables through M12x1.5 cable glands and connect them to the terminal blocks. Tighten the cables in the glands.
  6. Pass Power and LED output cables through M20x1.5 cable glands and connect them to the terminal blocks. Tighten the cables in the glands.

Cable Gland Diameters:

  • M12x1.5 (DMX IN/OUT, Ethernet IN/OUT): for cables of 3-7mm diameter.
  • M20x1.5 (Power IN, LED Output): for cables of 7-13mm diameter.
  1. Check that all screws and cable glands are firmly tightened.
  2. Screw the terminal blocks cover (H) back onto the E-box Remote.
  3. Connect the E-box Remote to mains power.
  4. Set the E-box Remote using the control panel (E) and buttons (F).
  5. Disconnect the E-box Remote from mains and screw the cover (A) back on.

IMPORTANT: ALWAYS DISCONNECT THE E-BOX REMOTE FROM MAINS BEFORE CONNECTING/DISCONNECTING LED MODULES.

This device falls under protection class I. Therefore, every E-box Remote has to be connected to a mains socket outlet with a protective earthing connection.

Power Connection Wiring:

Connection L N Ground
Wire (CE) Brown Blue Green/yellow
Wire (US) Black White Green

4. Eminere Remote Modes

The E-box Remote menu allows switching connected Emineres Remote to two modes:

  • Standard: LED modules are switched to an internal serial connection. DMX addressing is automatic (default DMX address = 1), adjustable via E-box Remote or RDM. This is the default mode.
  • Pass-Thr (Pass through): LED modules are switched to an internal parallel connection. DMX addressing must be done manually via the Robe Universal Interface (or its wireless version Robe Universal Interface WTX) and the RDM Manager software.

Note: RDM manager and DMX controller cannot be connected at the same time.

The E-box Remote and connected Eminere Remotes can be configured using the RDM Manager software. The interface allows setting DMX address and Personality for each LED module.

When no DMX is received, the unit defaults to a Demo mode. This can be modified by setting a desired look via DMX and saving it via RDM by setting "Init position LEDs" to 1.

The last Eminere on each DMX line may be terminated by setting the ‘Manufacturer PID’ 'Terminator active' to ‘1’. Ensure the fixture is not already terminated with a 120 Ohm resistor.

The function "Pixel swap" from the RDM control panel allows swapping the pixel order. Pixel Swap 0 disables this function, while Pixel Swap 1 enables it, reordering the pixels in the chain.

5. E-box Remote Menu

The E-box Remote is equipped with a 2-row LCD display and four buttons for addressing and configuring the fixture's behavior.

Control Buttons:

  • ESCAPE button: To escape a function or menu.
  • ENTER button: To select a function or confirm an adjusted value.
  • UP and DOWN buttons: To navigate within the menu.

Important: After changing any setting, disconnect and reconnect power to the E-box Remote to activate the changes.

Some menu items are not accessible if the "Pass-Thr" option is selected for E-box mode (menu Personality).

5.1 DMX Addr

  • Set DMX Address: Sets the DMX start address for the fixture. This is the first channel the E-box Remote responds to from a DMX controller. (Not available in Pass-Thr mode).
  • IP address: Allows setting the fixture's IP address for network identification.
  • Default Address: Uses the fixture's MAC address for the IP address.
  • Custom Address: Allows manual entry of an IP address (e.g., 172.16.254.1).
  • Network mask: Sets the network mask for IP address subnetting.

5.2 Info

Provides information about the fixture and connected Eminere Remotes.

  • Software version: Displays software versions of the E-box Remote and connected Emineres.
  • Databox: Shows the E-box Remote version.
  • PWR-1 v1: Displays the version of connected Eminere Remotes. Update to the latest version if multiple versions are present.
  • WL: Version of the wireless DMX module (if installed).
  • IP Addr: Shows the current IP address.
  • RDM UID: Reads the RDM UID.
  • MAC Adr: Reads the MAC address.
  • Outputs Info: Provides information about connected Emineres per output (e.g., Fixture Count, Footprint).
  • Temp: Displays the internal temperature of the E-box Remote.

5.3 Personality

Modifies the E-box Remote's operating behavior.

  • DMX Preset: Selects the Eminere Remote channel mode (accessible in Standard mode only). Options include Total, Fixture, Pixel, and Output modes.
  • DMX Input: Chooses the DMX data input source: Wired DMX, Wireless DMX, Wireless Out DMX, or Ethernet.
  • Ethernet Settings: Configures Ethernet operation modes (Art-Net, sACN, MA Net, MA Net2) and parameters.
  • Display Settings: Adjusts display properties like Off Timer, Lightness, and Contrast.
  • RGB(W) Split: Determines how the last pixel of a DMX Universe is handled if channels are insufficient (Disabled or Enabled).
  • Input Data: Selects the type of input data (RGBW or RGB).
  • DMX Hold: Keeps the last received DMX values if data reception is interrupted.
  • E-box mode: Selects the connection method for Eminere Remotes (Standard or Pass-Thr).
  • Default setting: Resets fixture personalities to factory defaults.

5.4 Test Programs

Runs test sequences without an external controller.

  • Colors: Runs a color-changing loop for all LEDs (requires Standard mode).
  • Pixels: Runs a pixel program loop (requires Standard mode; number of pixels depends on DMX Preset setting).

5.5 Stand Alone

Allows fixtures to execute pre-set programs without a controller (requires Standard mode).

  • Auto Run: Selects a program to play automatically on power-up.
  • Off: Disables Auto Run.
  • Test C: Runs a color-changing test on connected LED modules.
  • Test P: Runs a pixel program test on connected LED modules.

5.6 Special Settings

  • Wireless: Provides information about wireless DMX operation (Stat, Unlink).
  • Software Update: Enters update mode. Updates the E-box Remote and connected Eminere Remotes (Standard mode) or only Eminere Remotes (Pass-Thr mode).

6. Software Update

Software updates for the E-box Remote can be performed via an Ethernet connection using ROBE Uploader software or via the Robe Universal Interface (Robe Universal Interface WTX and ROBE RDM Uploader software). The ROBE Uploader automates the update process.

For more information, visit: https://www.robe.cz/robe-uploader/

Examples of connections for software update:

  • By means of the Ethernet connection: A computer running ROBE Uploader connects via an Ethernet switch to the E-box Remote.
  • By means of the Robe Universal Interface: A computer connects to the Robe Universal Interface via USB, and the interface connects to the E-box Remote via a DMX data cable.

7. DMX Protocol

This section details the DMX channel assignments for controlling the LEDs.

Channel DMX Value Function Type of control
1 0-255 Red LEDs (Pixel 1) proportional
2 0-255 Green LEDs (Pixel 1) proportional
3 0-255 Blue LEDs (Pixel 1) proportional
4 0-255 White LEDs (Pixel 1) proportional
5 0-255 Red LEDs (Pixel 2) proportional
6 0-255 Green LEDs (Pixel 2) proportional
7 0-255 Blue LEDs (Pixel 2) proportional
8 0-255 White LEDs (Pixel 2) proportional
: : : :
Depends on number of pixels N 0-255 White LEDs (Pixel N) proportional

8. Technical Specifications

Input voltage 120-240 V AC; 277V AC
Frequency 50/60Hz
Power consumption 520W
Fuse 1 T6.3A/500V AC
Fuse 2 T8A/250V AC
Fuse 3 T8A/250V AC
LED Output
Number of outputs 2
Voltage 48V DC
Max output power 380W per output
Total Output power 480W max. per fixture
Control
Supported protocols USITT DMX 512, RDM, ArtNet, MA Net, MA Net2, sACN, Kling-Net
Operating modes Pixel (12 LEDs) or Fixture mode
Connection
Power IN terminal block
Ethernet IN/OUT terminal block
DMX IN/OUT terminal block
LED Outputs terminal block
Operating ambient temperature range -20/+40°C (-4°F / +104°F)
Cooling System convection
Protection factor IP65 (CE), Suitable for Wet Locations (US)
IK Rating IK10
Weight 5.5 kg (12.13 lbs)
Dimensions
mm [inch]

Width: 360 mm [14 3/16"]

Height: 110 mm [4 5/16"]

Depth: 160 mm [6 5/16"]

9. Disposing of the Product

To preserve the environment, please dispose of or recycle this product at the end of its life according to the local regulations and codes.

10. Change Log

This section summarizes changes in the user manual.

Version of the manual Date of issue Description of changes
1.1 26/01/2022 Description of connection blocks modified
1.2 24/02/2022 Description of the fixture corrected
1.3 14/03/2022 Design of the manual changed
1.4 07/04/2022 Menu DMX preset added, menu Devices removed, Eminere connection changed
1.5 28/04/2022 Eminere connection changed
1.6 17/08/2022 Eminere connection changed

August 17, 2022

Specifications are subject to change without notice.

Copyright © 2021-2022 Robe Lighting - All rights reserved

Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701 Valasske Mezirici

Models: E-Box Remote, E-Box, Remote

File Info : application/pdf, 20 Pages, 3.32MB

PDF preview unavailable. Download the PDF instead.

User manual E-box Remote v1.6 August 2022 0

References

Microsoft: Print To PDF

Related Documents

Preview Anolis Eminere LED Fixture User Manual
Comprehensive user manual for the Anolis Eminere series of LED lighting fixtures, covering installation, technical specifications, maintenance, and safety instructions.
Preview Anolis Eminere Series LED Lighting Fixture User Manual
Comprehensive user manual for the Anolis Eminere series of LED lighting fixtures (Eminere 1, 2, 3, 4). Covers safety, installation, technical specifications, connections, booster box usage, maintenance, and accessories.
Preview Eminere Calibration Repair Procedure: Loss of White Colour Values (CTC)
Step-by-step guide for Anolis Eminere lighting fixtures to repair loss of calibration values for white colours (CTC) using DMX and RDM Manager.
Preview ANOLIS Eminere Remote UV 2 & 4 User Manual
User manual for ANOLIS Eminere Remote UV 2 and UV 4 professional UV LED lighting fixtures. Covers installation, safety, technical specifications, and maintenance for optimal use.
Preview Anolis Calumma XS MC/SC User Manual - Installation, Operation, and Specifications
This user manual provides comprehensive instructions for the Anolis Calumma XS MC and Calumma XS SC lighting fixtures, covering installation, safety, technical specifications, software updates, and maintenance. Learn how to operate your professional lighting equipment effectively.
Preview Anolis Calumma Remote M User Manual: Installation, Specifications, and Operation
Detailed user manual for Anolis Calumma Remote M MC and SC LED lighting fixtures. Includes safety guidelines, installation instructions, connection diagrams, technical specifications, software updates, and DMX protocol details.
Preview Ambiane HP111 Recessed User Manual - Anolis LED Lighting
Comprehensive user manual for the Anolis Ambiane HP111 Recessed LED luminaire, covering installation, technical specifications, DMX/DALI/RDM control, maintenance, and software updates.
Preview Ambiane TD LED Fixture User Manual and Installation Guide
Comprehensive user manual and installation guide for the Anolis Ambiane TD LED lighting fixture, detailing setup, control protocols (DMX, DALI, 0-10V), technical specifications, and software update procedures.