SA5000 Flow Sensor
Model: SAD10XDBFRKG/US-100
Product Overview
The SA5000 is a versatile flow sensor designed for monitoring flow rates in various media, including water, glycol solutions, air, and oils. It features an alphanumeric 4-digit red/green LED display and a rotatable housing for flexible installation.
Key Features:
- LED Display unit / Switching status
- Alphanumeric display (4-digit red/green)
- Programming buttons
- Upper part of the housing can be rotated 345°
- Approvals: CE, CRN, CULUS, EAC
- IO-Link communication
Application
Parameter | Specification |
---|---|
Media | water; glycol solutions; air; oils |
Note on media | low-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C) high-viscosity oils with viscosity: > 40 mm²/s (40 °C) |
Medium temperature | -20...90 °C |
Pressure rating | 100 bar |
MAWP (for applications according to CRN) | 100 bar |
Electrical Data
Parameter | Specification |
---|---|
Operating voltage | 18...30 DC V |
Current consumption | < 100 mA |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time | 10 s |
Inputs / Outputs
Number of digital outputs: 2; Number of analog outputs: 1
Parameter | Specification |
---|---|
Total number of outputs | 2 |
Output signal | switching signal; analog signal; frequency signal; IO-Link (configurable) |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / closed; (configurable) |
Max. voltage drop switching output DC | 2.5 V |
Permanent current rating of switching output DC | 250 mA |
Number of analog outputs | 1 |
Analog current output | 4...20 mA (scalable) |
Max. load | 350 Ω |
Short-circuit protection | yes |
Type of short-circuit protection | yes (non-latching) |
Overload protection | yes |
Frequency of the output | 0...1000 Hz |
Measuring/Setting Range
Parameter | Specification |
---|---|
Probe length L | 45 mm |
Operating mode | relative; absolutely liquid; absolutely gaseous |
Note on setting range | Operating mode: relative |
Liquids Measuring range | 0.04...3 m/s |
Liquids Setting range | 0...6 m/s |
Gases Measuring range | 2...100 m/s |
Gases Setting range | 0...200 m/s |
Temperature monitoring Measuring range | -20...90 °C |
Temperature monitoring Resolution | 0.2 °C |
Accuracy / Deviations
Flow monitoring
Parameter | Specification |
---|---|
Temperature drift | 0,003 m/s x 1/K (< 20 °C; > 70 °C) |
Max. temperature gradient of medium | 100 K/min |
Accuracy (in the measuring range) | ± (7% MW + 2% MEW); (for relative mode in the measuring range with: water: 20...70 °C; inlet length: 1,5 m; DN25 (DIN 2448); mounting position according to instructions. Accuracy can differ for other media and mounting positions.) |
Repeatability | 0,05 m/s; (water; Flow velocity: 0,05...3 m/s) |
Temperature monitoring
Parameter | Specification |
---|---|
Temperature drift | ± 0,005 K/°C |
Accuracy | ± 0,3 / ± 1; (water; Flow velocity: 0,3...3 m/s / air; Flow velocity: > 10 m/s) |
Reaction times
Parameter | Specification |
---|---|
Flow monitoring Response time | 0.5 s (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09) |
Temperature monitoring Dynamic response T05 / T09 | 1.5 s (T09); (water; Flow velocity: 0,3...3 m/s) |
Software / programming
Parameter setting options: hysteresis / window; normally open / closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value color.
Interfaces
Parameter | Specification |
---|---|
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
IO-Link device ID | 533 d / 00 02 15 h (REL) |
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode | yes |
Required master port class | A |
Process data analogue | 2 |
Process data binary | 2 |
Min. process cycle time | 3 ms |
Operating conditions
Parameter | Specification |
---|---|
Ambient temperature | -40...80 °C |
Storage temperature | -40...100 °C |
Protection | IP 65; IP 67 |
Tests / approvals
Parameter | Specification |
---|---|
EMC | DIN EN 60947-5-9 |
Shock resistance | DIN EN 60068-2-27 |
Vibration resistance | DIN EN 60068-2-6 |
MTTF | 132 years |
UL approval number | 1003 |
Mechanical data
Parameter | Specification |
---|---|
Weight | 311.5 g |
Material | stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30 |
Materials (wetted parts) | stainless steel (1.4404 / 316L); Gasket: FKM |
Process connection | threaded connection M18 x 1,5 Internal thread |
Displays / operating elements
Element | Description |
---|---|
Display unit | 6 x LED, green (%, m/s, l/min, m³/h, °C, 10³) |
Switching status | 2 x LED, yellow |
Measured values | alphanumeric display, red/green 4-digit |
Electrical connection
Connector: 1 x M12; Contacts: gold-plated
Pinout:
- 1: BN (Brown) - L+
- 2: WH (White) - OUT2
- 3: BU (Blue) - L-
- 4: BK (Black) - OUT1
Output Functions:
- OUT1: Switching output Volumetric flow quantity monitoring, Frequency output Volumetric flow quantity monitoring, IO-Link
- OUT2: Switching output Volumetric flow quantity monitoring, Switching output Temperature monitoring, analog output Volumetric flow quantity monitoring, analog output Temperature monitoring, Frequency output Volumetric flow quantity monitoring, Frequency output Temperature monitoring, Input External Teach
Remarks
MW = Measured value
MEW = Final value of the measuring range
- 540 d / 00 02 1ch (LIQU)
- 547 d / 00 02 23 h (GAS)
Pack quantity: 1 pcs.
Related Documents
![]() |
SA5000 Flow Sensor: Technical Specifications and Features Comprehensive technical data, features, and application details for the IFM SA5000 flow sensor, including electrical, mechanical, and environmental specifications. |
![]() |
ifm SM2001 Magnetic-Inductive Flow Meter Technical Specification Detailed technical specifications, features, and application data for the ifm SM2001 magnetic-inductive flow meter, including electrical, mechanical, and output characteristics, accuracy, and interface information. |
![]() |
ifm Vibration Sensor with IO-Link Interface Device Manual This document provides detailed information on the ifm vibration sensor with IO-Link interface, covering its functions, installation, electrical connection, parameter settings, and troubleshooting. It includes specifications for different models and software versions. |
![]() |
ifm Industrial Sensors and Controls Catalog Explore ifm's comprehensive range of industrial automation sensors and controls, featuring IO-Link technology, photoelectric sensors, inductive sensors, and more. Discover high-quality solutions for enhanced productivity and efficiency. |
![]() |
ifm Magnetic-Inductive Flow Meters: Operating Instructions Comprehensive operating instructions for ifm's magnetic-inductive flow meters, covering installation, functions, parameter settings, and troubleshooting. Features models SM4x20, SM6x20, SM7x20, SM8x20, SM8x30, SM6x21, SM7x21, SM8x21, SM8x31, and others. Visit www.ifm.com for more information. |
![]() |
ifm ZZ1060 IO-Link Master with USB Interface: Setup and Operation Guide Comprehensive guide for setting up and operating the ifm ZZ1060 IO-Link master with USB interface, including connection, parameter setting with ifm moneo|configure free, and process data monitoring. |
![]() |
ifm Flow Monitor SI0558 SI0564 Operating Instructions Detailed operating instructions for the ifm Flow Monitor models SI0558 and SI0564, covering installation, setup, settings, operation, and troubleshooting. |
![]() |
IFM SI1010 Flow Monitor Technical Specifications and Application Guide Detailed technical specifications, application information, and wiring diagrams for the IFM SI1010 compact flow monitor. Learn about its features, electrical and mechanical data, and operating parameters for coolants and oils in machine tools. |