MEAN WELL RS-25 Series 25W Single Output Switching Power Supply
Technical Specification
Features
- Universal AC input / Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- LED indicator for power on
- 100% full load burn-in test
- All using 105°C long life electrolytic capacitors
- Withstand 300VAC surge input for 5 seconds
- High operating temperature up to 70°C
- Withstand 5G vibration test
- No load power consumption <0.5W
- High efficiency, long life and high reliability
- 3 years warranty
Specifications
GTIN CODE: MW Search: https://www.meanwell.com/serviceGTIN.aspx
MODEL | RS-25-3.3 | RS-25-5 | RS-25-12 | RS-25-15 | RS-25-24 | RS-25-48 | |
---|---|---|---|---|---|---|---|
DC VOLTAGE | 3.3V | 5V | 12V | 15V | 24V | 48V | |
RATED CURRENT | 6A | 5A | 2.1A | 1.7A | 1.1A | 0.57A | |
CURRENT RANGE | 0~6A | 0~5A | 0~2.1A | 0~1.7A | 0~1.1A | 0~0.57A | |
RATED POWER | 19.8W | 25W | 25.2W | 25.5W | 26.4W | 27.36W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 80mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 2.85~3.6V | 4.75~5.5V | 10.8~13.2V | 13.5~16.5V | 22~27.6V | 42~54V | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION Note.5 | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1800ms, 23ms/230VAC | 4000ms, 30ms/115VAC at full load | |||||
HOLD UP TIME (Typ.) | 80ms/230VAC | 14ms/115VAC at full load | |||||
VOLTAGE RANGE | 88~264VAC / 125~373VDC (Withstand 300VAC surge for 5sec. Without damage) | ||||||
FREQUENCY RANGE | 47~63Hz | ||||||
EFFICIENCY(Typ.) | 73.5% | 78.5% | 81.5% | 83.5% | 86% | 85% | |
AC CURRENT (Typ.) | 0.7A/115VAC | 0.4A/230VAC | |||||
INRUSH CURRENT (Typ.) | COLD START 45A/230VAC | ||||||
LEAKAGE CURRENT | <2mA / 240VAC | ||||||
OVERLOAD PROTECTION | 110~180% rated output power; Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||
OVER VOLTAGE | 3.8~4.45V | 5.75~6.75V | 13.8~16.2V | 17.25~20.25V | 27.6~32.4V | 55.2~64.8V | |
WORKING TEMP. | -20~+70°C (Refer to "Derating Curve") | ||||||
WORKING HUMIDITY | 20~90% RH non-condensing | ||||||
ENVIRONMENT STORAGE TEMP., HUMIDITY | -40~+85°C, 10~95% RH | ||||||
TEMP. COEFFICIENT | ±0.03%/°C (0~50°C) | ||||||
VIBRATION | 10~500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, AS/NZS 62368.1, EAC TP TC 004, CCC GB4943.1, BSMI CNS14336-1, BIS IS13252(Part1):2010/IEC 60950-1: 2005 approved | ||||||
SAFETY & WITHSTAND VOLTAGE | I/P-O/P:3KVAC / I/P-FG:2KVAC / O/P-FG:0.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/70% RH | ||||||
EMC (Note 6) | EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, GB9254 class B, GB17625.1, EAC TP TC 020, CNS13438 Class B | |||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020 | ||||||
OTHERS | MTBF | 3992.0K hrs min. Telcordia SR-332 (Bellcore); 663.3K hrs min. MIL-HDBK-217F (25°C) | |||||
DIMENSION | 78*51*28mm (L*W*H) | ||||||
PACKING | 0.2Kg; 60pcs/13Kg/0.46CUFT |
Notes:
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 µF & 47 µF parallel capacitor.
- 3. Tolerance: includes set up tolerance, line regulation and load regulation.
- 4. Line regulation is measured from low line to high line at rated load.
- 5. Load regulation is measured from 0% to 100% rated load.
- 6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 7. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
* Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Mechanical Specification
Case No.931A Unit:mm
Overall Dimensions:
The unit has dimensions of 78mm (Length) x 51mm (Width) x 28mm (Height). Key features include mounting holes and a terminal block.
Terminal Pin Assignment:
Pin No. | Assignment | Pin No. | Assignment |
---|---|---|---|
1 | AC/L | 4 | DC OUTPUT -V |
2 | AC/N | 5 | DC OUTPUT +V |
3 | FG |
Additionally, there is a +V ADJ. terminal and an LED indicator.
Block Diagram:
The block diagram illustrates the internal signal flow: AC input (I/P) passes through an EMI FILTER, then RECTIFIERS & FILTER, followed by POWER SWITCHING controlled by PWM CONTROL and O.L.P. (Over Load Protection). The output stage includes RECTIFIERS & FILTER and a DETECTION CIRCUIT, providing the final DC output (+V, -V). The FG (Frame Ground) is connected to the chassis.
Derating Curves:
Ambient Temperature Derating: The derating curve shows that the 3.3V model's load capacity begins to decrease around 50°C ambient temperature, while other models maintain full load capacity up to 70°C ambient temperature. The x-axis represents Ambient Temperature (°C) from -20 to 70, and the y-axis represents Load (%).
Output Derating vs. Input Voltage: This graph shows that the power supply operates at 100% load across the entire input voltage range from 88VAC to 264VAC, with no significant derating required within this range. The x-axis represents Input Voltage (VAC) from 88 to 264, and the y-axis represents Load (%).