User's Manual: Waste Water Pump

Model: 62935

[Image: A submersible waste water pump with a power cable and float switch.]

Please read and follow the operating instructions and safety information prior to initial operation. Technical changes reserved! Illustrations, functional steps, and technical data may deviate insignificantly due to continuous further developments.

Introduction

Thank you for choosing this quality product. To minimise the risk of injury, please follow basic safety precautions when using this product. Read this operating manual carefully and ensure you understand it. Keep these operation instructions in a safe place.

Safety Instructions

Caution!

Attention!

Warning!

Range of Application

This submersible pump is usually installed in basements, providing protection from flooding. Additionally, the pump can be used for transporting water from one spot to another, e.g., at home, in agriculture, in gardening, for sanitary work, and so forth.

Resistance

Installation

The pump is installed in a fixed position, either with fixed or flexible tubing.

Attention!

Note: The pump shaft should have a minimum size of 40×40×50 cm, so that the float switch can move freely.

Mains Connection

The purchased pond pump is equipped with a protection plug. It is meant to be connected to a 220/230 V~50 Hz safety socket. Ensure the socket is sufficiently protected (min. 6 A) and fully functional. Plug in the plug, and the pump is operational.

Note: If the cable or the plug is damaged due to external influences, the cable must not be repaired. It must be replaced with a new one by an electrician.

Operation Settings

After carefully reading all information and instructions, the pump can be operated by following these steps:

Maintenance Guidelines

This submersible pump is a certified quality product subject to strict final inspection. Regular inspection and maintenance are recommended to ensure a longer lifespan and interruption-free operation.

Important Instructions!

Cleaning the Impeller

If there are excessive residues collected in the pump casing, the bottom part of the pump needs to be demounted as follows:

  1. Remove the suction cage from the housing of the pump.
  2. Clean the impeller with clear water.
  3. Important! The pump must not be placed or supported on the impeller.
  4. Follow the previous steps in reverse order to reassemble the pump.

Setting the Switch-Point

Fix the cable of the float switch to the cable clip found on the casing of the pump to set the desired switch-on and switch-off height.

Troubleshooting

ProblemCauseSolution
Pump does not startNo power supplyCheck power supply.
Float switch does not switchPlace float switch in a higher position.
No flowInlet filter cloggedClean inlet filter with water stream.
Pressure hose kinkedAdjust hose.
Pump does not switch offFloat switch cannot sinkPlace pump properly on the shaft floor.
Insufficient flowInlet filter cloggedClean inlet filter.
Reduced pumping performance due to dirty water or water containing abrasive materialClean pump and replace worn parts.
The pump switches itself off after short running periodThermal switch stops pump due to waste water.Pull power plug. Clean pump and shaft.
Water too hot, thermal switch stops pumpEnsure that the maximal water temperature does not exceed 35 °C.

Technical Specifications

Power consumption (W)400
Intake voltage (V)230
Frequency (Hz)50
Flow rate (/h)7500
Max. immersion depth (m)7
Max. lifting height (m)6.5
Max. particle size (mm)5
Length of cable (m)10

Regulations for Waste Disposal

The Waste Electrical and Electronic Equipment Directive (WEEE Directive, 2012/19/EU) of the EU was implemented in the German law related to electrical and electronic equipment and appliances.

All WilTec electric devices that fall under the WEEE directive are labelled with the symbol of a crossed-out wheeled rubbish bin. This symbol indicates that this electric device must not be disposed of with the domestic waste. [Symbol: Crossed-out wheeled rubbish bin]

WilTec Wildanger Technik GmbH is registered with the German registration authority EAR (Stiftung Elektro-Altgeräte Register) under the WEEE-registration number DE45283704.

Disposal of used electrical and electronic devices (intended for use in the countries of the European Union and other European countries with a separate waste collection system for these devices).

The symbol on the packaging or the product itself indicates that this product must not be treated as normal domestic waste but must be disposed of at a recycling collection station for electrical and electronic waste.

By disposing of this product correctly, you contribute to the protection of the environment and the health of your fellow people. Inappropriate disposal threatens the environment and health.

Material recycling helps to reduce the consumption of raw materials.

Additional information about the recycling of this product can be provided by your local commune, the municipal waste disposal facilities, or the store where you purchased the product.

Address: WilTec Wildanger Technik GmbH, Königsbenden 12 / 28, 52249 Eschweiler, Germany.

Important Note:

Reproduction and any commercial use (of parts) of this operating manual requires a written permission of WilTec Wildanger Technik GmbH.

External Links

Models: 62935 Waste Water Pump, 62935, Waste Water Pump, Water Pump, Pump

File Info : application/pdf, 7 Pages, 368.64KB

PDF preview unavailable. Download the PDF instead.

62935-doc-en

References

Microsoft Word 2016 Microsoft Word 2016

Related Documents

Preview XPOtool Waste Water Pump 61962 Instruction Manual
Comprehensive instruction manual for the XPOtool 61962 Waste Water Pump, covering safety, installation, operation, maintenance, and technical specifications. Learn how to safely and effectively use your submersible pump.
Preview XPOtool EPC-2 Pressure Switch Operation Manual
Comprehensive operation manual for the XPOtool EPC-2 pressure switch, detailing technical specifications, installation, operation, troubleshooting, and safety guidelines.
Preview XPOtool 63003 Piston Pump Paint Sprayer Operation Manual
Comprehensive operation manual for the XPOtool 63003 Piston Pump Paint Sprayer. Covers safety, assembly, operation, maintenance, troubleshooting, and parts. Essential guide for safe and effective use.
Preview Istruzioni d'uso Pressostato XPOtool Serie EPC-2
Manuale d'uso completo per il pressostato XPOtool serie EPC, modello EPC-2 (articolo 51566). Include istruzioni di sicurezza, dati tecnici, guide operative, risoluzione problemi e indicazioni per lo smaltimento fornite da WilTec Wildanger Technik GmbH.
Preview XPOtool Airbrush Extraction System with Water Wall (Model 34280) - Operation Manual
Comprehensive operation manual for the XPOtool Airbrush Extraction System with Water Wall (Model 34280). This guide provides essential safety instructions, a detailed parts list, assembly procedures, operational guidance, filter maintenance, and disposal regulations for the airbrush spray booth.
Preview XPOtool Dump Cart User Manual (Models 30261, 30329)
Comprehensive user manual for the XPOtool Dump Cart (models 30261, 30329), covering safety instructions, parts list, technical specifications, and assembly overview. Learn how to safely operate and maintain your dump cart.
Preview XPOtool Hand Winch 1500 kg (62974) Operation Manual
Official operation manual for the XPOtool 1500 kg Hand Winch (Model 62974). Includes comprehensive safety instructions, maintenance guidelines, technical specifications, parts identification, and contact information from WilTec Wildanger Technik GmbH.
Preview XPOtool Mototrivella (2 Person) User Manual and Safety Guide
Comprehensive user manual for the XPOtool Mototrivella (2 Person), covering assembly, operation, safety instructions, maintenance, and troubleshooting for models 62350, 62351, 62650-62663.