Thank you for choosing this quality product. To minimise the risk of injury, please follow basic safety precautions when using this product. Read this operating manual carefully and ensure you understand it. Keep these operation instructions in a safe place.
Safety Instructions
Caution!
- In and near standing water, garden ponds, and swimming ponds, the use of this device is only allowed with a fault current protection switch with a triggering nominal current up to 30 mA (according to VDE 0100 Article 702 and 738).
- The device is not suitable for use in swimming pools, paddling pools of any kind or waters in which people or animals may stay during operation. Operation of the device with people being in the danger area is not permitted. Consult an electrician if necessary.
- The device is not intended for use by persons (including children) with impaired or limited physical, sensory, and mental abilities or lack of experience and/or real knowledge, unless they are supervised by a person responsible for their safety or follow the instructions made by this person on how to correctly use the device. Children should be supervised to ensure that they do not play with the device.
Attention!
- Perform a visual inspection of the device before every use. Do not use the device if the safety appliances are damaged or worn out. Never override safety regulations.
- Only use the device according to the intended purpose stated in this manual.
- You are responsible for the safety of the working zone.
- If the cable or the plug is damaged due to external influences, the cable must not be repaired. It must be replaced with a new one. This work can only be carried out by an electrician.
- The voltage of 230 V AC indicated on the nameplate of the device must match the existent mains voltage.
- Never lift, carry, or fix the device by using the power cable.
- Make sure that the electric plug connections are protected from flood and humidity.
- Pull out the power plug before performing any kind of work on the device.
- Avoid exposing the device to direct jets of water.
- The user is responsible for complying with local safety and mounting regulations. Consult an electrician, if necessary.
- The user must take appropriate measures (e.g., installation of an alarm system, a reserve pump, etc.) to prevent damage caused by flooding in case of device malfunctioning.
- In case of device failure, repairs can only be carried out by an electrician.
- The device must never run dry or be operated with its suction line fully closed.
- Do not use this device to operate swimming pools.
- This device must not be integrated into any kind of domestic water circuit meant for potable water.
Warning!
- Thoroughly read all safety warnings and instructions contained within this operation manual. Failure to obey the safety precautions and instructions might cause an electric shock, a fire, and/or severe injuries. Keep all safety precautions and instructions for future use.
Range of Application
This submersible pump is usually installed in basements, providing protection from flooding. Additionally, the pump can be used for transporting water from one spot to another, e.g., at home, in agriculture, in gardening, for sanitary work, and so forth.
Resistance
- The maximum temperature of the pumped liquid should not exceed +35 °C in continuous operation.
- The pump must not be used to pump flammable, gassing, or explosive liquids.
- The pump must not be used to pump other liquids, especially motor fuels, cleaning agents, or other chemical products.
Installation
The pump is installed in a fixed position, either with fixed or flexible tubing.
Attention!
- When installing the pump, do not freely suspend it by its pressure line or power cable. The submersible motor pump needs to be hung up by the appropriate handle or placed on the floor of the shaft.
- To ensure the impeccable functioning of the pump, the shaft floor needs to be kept free of mud and dirt of any kind.
- If the water level is too low, the mud on the shaft floor might quickly dry and hinder the pump from starting. It is therefore necessary to regularly check the pump (by performing tests before operation).
- The float switch is adjusted to allow the pump to start immediately.
Note: The pump shaft should have a minimum size of 40×40×50 cm, so that the float switch can move freely.
Mains Connection
The purchased pond pump is equipped with a protection plug. It is meant to be connected to a 220/230 V~50 Hz safety socket. Ensure the socket is sufficiently protected (min. 6 A) and fully functional. Plug in the plug, and the pump is operational.
Note: If the cable or the plug is damaged due to external influences, the cable must not be repaired. It must be replaced with a new one by an electrician.
Operation Settings
After carefully reading all information and instructions, the pump can be operated by following these steps:
- Check if the pump is resting on the bottom of the shaft.
- Check if the pressure line is properly attached.
- Check if the electric source is 230 V~50 Hz.
- Check if the socket is in a good condition.
- Make sure that the electrical connections and circuits are sufficiently protected from moisture and water.
- Do not allow the pump to run dry.
Maintenance Guidelines
This submersible pump is a certified quality product subject to strict final inspection. Regular inspection and maintenance are recommended to ensure a longer lifespan and interruption-free operation.
Important Instructions!
- Properly disconnect the pump from its power supply by removing its plug from the socket before performing any maintenance work.
- In case of the pump being transported or moved around a lot, clean it with clear water after every use.
- If the pump remains stationary for a longer time, check the function of its lock switch every 3 months.
- Fibrous material that might have accumulated within the pump housing should be removed with water.
- Every 3 months, the shaft bottom should be freed from mud.
- Remove residues on the float switch with clear water.
Cleaning the Impeller
If there are excessive residues collected in the pump casing, the bottom part of the pump needs to be demounted as follows:
- Remove the suction cage from the housing of the pump.
- Clean the impeller with clear water.
- Important! The pump must not be placed or supported on the impeller.
- Follow the previous steps in reverse order to reassemble the pump.
Setting the Switch-Point
Fix the cable of the float switch to the cable clip found on the casing of the pump to set the desired switch-on and switch-off height.
- The float switch is installed so that the switch-on and switch-off point can be reached without any problem. To check this, place the pump into a container filled with water, carefully lift the float switch by hand and lower it again. Observe if the pump switches itself on and off.
- To ensure the pump switches itself on and off properly, the length of the cable comprised between the float switch and fixing clip must be a minimum of 10 cm.
- When setting the float switch, make sure that the water has a minimum level of 15 mm to prevent the pump from running dry.
Troubleshooting
Problem | Cause | Solution |
---|---|---|
Pump does not start | No power supply | Check power supply. |
Float switch does not switch | Place float switch in a higher position. | |
No flow | Inlet filter clogged | Clean inlet filter with water stream. |
Pressure hose kinked | Adjust hose. | |
Pump does not switch off | Float switch cannot sink | Place pump properly on the shaft floor. |
Insufficient flow | Inlet filter clogged | Clean inlet filter. |
Reduced pumping performance due to dirty water or water containing abrasive material | Clean pump and replace worn parts. | |
The pump switches itself off after short running period | Thermal switch stops pump due to waste water. | Pull power plug. Clean pump and shaft. |
Water too hot, thermal switch stops pump | Ensure that the maximal water temperature does not exceed 35 °C. |
Technical Specifications
Power consumption (W) | 400 |
Intake voltage (V) | 230 |
Frequency (Hz) | 50 |
Flow rate (/h) | 7500 |
Max. immersion depth (m) | 7 |
Max. lifting height (m) | 6.5 |
Max. particle size (mm) | 5 |
Length of cable (m) | 10 |
Regulations for Waste Disposal
The Waste Electrical and Electronic Equipment Directive (WEEE Directive, 2012/19/EU) of the EU was implemented in the German law related to electrical and electronic equipment and appliances.
All WilTec electric devices that fall under the WEEE directive are labelled with the symbol of a crossed-out wheeled rubbish bin. This symbol indicates that this electric device must not be disposed of with the domestic waste. [Symbol: Crossed-out wheeled rubbish bin]
WilTec Wildanger Technik GmbH is registered with the German registration authority EAR (Stiftung Elektro-Altgeräte Register) under the WEEE-registration number DE45283704.
Disposal of used electrical and electronic devices (intended for use in the countries of the European Union and other European countries with a separate waste collection system for these devices).
The symbol on the packaging or the product itself indicates that this product must not be treated as normal domestic waste but must be disposed of at a recycling collection station for electrical and electronic waste.
By disposing of this product correctly, you contribute to the protection of the environment and the health of your fellow people. Inappropriate disposal threatens the environment and health.
Material recycling helps to reduce the consumption of raw materials.
Additional information about the recycling of this product can be provided by your local commune, the municipal waste disposal facilities, or the store where you purchased the product.
Address: WilTec Wildanger Technik GmbH, Königsbenden 12 / 28, 52249 Eschweiler, Germany.
Important Note:
Reproduction and any commercial use (of parts) of this operating manual requires a written permission of WilTec Wildanger Technik GmbH.
External Links
- For contact information: https://www.wiltec.de/contacts/
- For the most recent version of this manual in several languages: https://www.wiltec.de/docsearch
- XPOtool Website: https://www.XPOtool.com