Lithonia Lighting Quantum LED Exit Signs
Features & Specifications
INTENDED USE: Ideal for applications requiring attractive, quick-installation exit signs and low energy consumption. Certain airborne contaminants can diminish the integrity of acrylic and/or polycarbonate. Refer to the Acrylic-Polycarbonate Compatibility table for suitable uses.
CONSTRUCTION: Engineering-grade thermoplastic housing is impact-resistant, scratch-resistant, and corrosion-proof. UL94V-0 flame rating. UV-stable resin resists discoloration from natural and man-made light sources. Rugged unibody housing snaps together with no additional mechanical fasteners. Faceplate and back cover are interchangeable on housing. Positive snap-fit tabs hold faceplate securely, yet easily removable for lamp compartment access. Universal directional Chevron inserts are easily removed and reinserted. Uniform illumination without shadows or hot spots. Reinforced, impact-resistant color panels. Letters 6" high with 3/4" stroke, with 100 ft. viewing distance rating, based upon UL924 standards.
U.S. Patent: No. 5,526,251; 5,611,163; 5,739,639; 5,954,423; 5,988,825; 6,152,581; D383,501; D495,751 and 6,502,044. Other patents pending.
OPTICS: LEDs mounted on printed circuit boards. Low energy consumption – less than one watt. LED lamp operates in normal (AC input) and emergency (DC input) modes. The typical life of the exit LED lamp is >5 years, based on 24/7 operation.
ELECTRICAL: Dual voltage input capability (120/277V) and 120V through 277V for MVOLT with SD. Low-voltage disconnect prevents excessively deep discharge that can permanently damage battery. Conveniently located test switch and LED provide visual and manual means of monitoring system. Constant-current series charger minimizes energy consumption and provides low operating costs. Printed circuit boards are 100% quality tested during manufacturing. Current-limiting charger circuitry protects printed circuit boards from shorts. AC/LV reset (line latch) allows battery connection before AC power is applied and aids in preventing battery damage from deep discharge. Crystal oscillator timing system with watchdog protection for precision accuracy. Brownout protection is automatically switched to emergency mode when supply voltage drops below 80% of nominal.
Battery: Sealed, maintenance-free nickel-cadmium battery delivers 90-minutes capacity to emergency lamps. Two-state constant-current charge maximizes battery life and automatically recharges after battery discharge.
Diagnostics: Single-point microcomputer control for all electronic features. Single multi-chromatic LED indicator to display two-state charging, test activation and three-state diagnostic status. SELF-DIAGNOSTICS (SD and AELR option) - Test switch provides manual activation of 30-second diagnostic testing for on-demand visual inspection. Self-diagnostic testing for five minutes every 30 days and 90 minutes every six months. Diagnostic evaluation of LED light source, AC to DC transfer, charging and battery condition. Continuously monitors AC functionality. AELR option: STAR (Self-testing Automated Reporting) radio transmits monthly and annual test results and diagnostics information for automated reporting requirements. For more information visit AcuityBrands.com/STAR.
INSTALLATION: Universal mounting canopy for top or end mount. Back mount standard for single face only. Easily removed mounting knockouts. J-box pattern on back panel. Housing snaps to canopy with four positive-locking tabs. Cam-locking pin tightly secures housing to canopy. Ships standard as single face exit with additional face plate and color panel. Allows capability to convert a single sided exit to a double sided exit in the field.
Specifications
Length | Depth | Height | Weight | |
11-3/4" (29.8 cm) | 2" (5.1 cm) | 7-5/8" (19.3 cm) | 2.6 lbs (1.2 kgs) |
All dimensions are in inches (centimeters) unless otherwise specified.
LISTINGS: UL damp location listed 50°-104°F (10°-40°C) standard. NOM Certified (see options). Meets UL924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. Meets all applicable FCC Title 47, Part 15, Subpart B requirements.
WARRANTY: 5-year limited warranty. (Battery is prorated.) This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-and-conditions
Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice.
Ordering Information
Catalog Number¹ | Description |
LQM S W 3 G 120/277 M6 | Quantum® LED thermoplastic exit, Stencil Face, White, Single with extra faceplate and color panel for field conversion to double face, Green, Dual voltage, Master pack of 6 |
LQM S 3 R 120/277 M6 | Quantum® LED thermoplastic exit, Stencil Face, Black, Single with extra faceplate and color panel for field conversion to double face, Red, Dual voltage, Master pack of 6 |
LQM S 3 G 120/277 M6 | Quantum® LED thermoplastic exit, Stencil Face, Black, Single with extra faceplate and color panel for field conversion to double face, Green, Dual voltage, Master pack of 6 |
LQM S W 3 R 120/277 X2 M6² | Quantum® LED thermoplastic exit, Stencil Face, White, Single with extra faceplate and color panel for field conversion to double face, Red, Primary and secondary AC inputs provided, Lamps wired on two separate circuits, Master pack of 6 |
LQM S 3 R 120/277 EL N M6 | Quantum® LED thermoplastic exit, Stencil Face, Black, Single with extra faceplate and color panel for field conversion to double face, Red, Dual voltage, Emergency battery back-up, Sealed, maintenance free nickel-cadmium battery, Master pack of 6 |
LQM S 3 R MVOLT EL N SD M6 | Quantum® LED thermoplastic exit, Stencil Face, Black, Single with extra faceplate and color panel for field conversion to double face, Red, 120 - 277V, Emergency battery back-up, Sealed, maintenance free nickel-cadmium battery, Emergency operation with self-diagnostic, Master pack of 6 |
LQM S 3 R MVOLT EL N SD AELR M6 | Quantum® LED thermoplastic exit, Stencil Face, Black, Single with extra faceplate and color panel for field conversion to double face, Red, 120 - 277V, Emergency battery back-up, Sealed, maintenance free nickel-cadmium battery, Self-diagnostics with Automatic Emergency Lighting Reporting, Master pack of 6 |
Example: LQM S 3 R MVOLT EL N SD M6
Accessories: Order as separate item.
- ELA WG1: Back-mount wireguard ³
- ELA LQMUS12: 12" stem kit ⁴
Notes:
- LQM available with Custom Signage. See spec sheet, Custom-Signage.
- Both circuits can be energized at the same time.
- See spec sheet ELA-WG.
- See spec sheet ELA-Stemkits.
Enabled with STAR
Emergency Lighting with Self-Testing Automated Reporting (STAR) enables self-testing and automated reporting to aid in life safety code compliance. Build your solution and choose your preferred deployment from Mobile STAR, where test data is logged in each individual unit and broadcast to the CLAIRity™+ app, or Connected STAR, where test data is logged in the STAR Gateway by IOTA® and emailed directly. Leave the ladders, disruptions and written records behind with emergency lighting solutions with STAR!
MOBILE STAR
CONNECTED STAR
Specifications
ELECTRICAL
Primary Circuit
Type¹ | Typical LED life² | Supply voltage | Input amps | Max. watts |
Red LED AC Only | >5 years | 120 | .62 | .05 |
277 | .69 | .06 | ||
Green LED AC Only | >5 years | 120 | .62 | .05 |
277 | .74 | .06 | ||
Red LED Emergency | >5 years | 120 | .71 | .05 |
277 | .92 | .06 | ||
Green LED Emergency | >5 years | 120 | .66 | .05 |
277 | .70 | .06 |
BATTERY
Nickel Cadmium
Voltage | Typical shelf life³ | Typical life³ | Maintenance⁴ | Temperature range |
1.2 | 3 years | 6-8 years | none | 50°F - 104°F (10°C -40°C) |
Notes:
- LED lamps operate in normal (AC input) and emergency (DC input) modes.
- Based on 24/7 operation. The typical life of the exit LED lamp is 5 years.
- At 77°F (25°C).
- All life safety equipment, including emergency lighting for path of egress must be maintained, serviced and tested in accordance with all National Fire Protection Association (NFPA) and local codes. Failure to perform the required maintenance, service, or testing could jeopardize the safety of occupants and will void all warranties. Temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity.
Mounting
All dimensions are inches (centimeters) unless otherwise specified.
Shipping weight: 2.6 lbs. (1.2 kgs.)