FP2070 SERIES
QUICK START GUIDE
Product Code
FP2070T-V2: 800 x 480, WVGA, 7" color TFT with 4-wire analog resistive touch screen with 2 serial ports, one USB Type C port & 1 USB Host port.
FP2070TN-V2: 800 x 480, WVGA, 7" color TFT with 4-wire analog resistive touch screen with 2 serial ports, one USB Type C port, one USB Host port & 1 Ethernet Port.
FP2070T-E: 800 x 480, WVGA, 7" color TFT with 4-wire analog resistive touch screen with 2 serial ports, one USB Type C port & 1 USB Host port. It supports upto 3 expansions.
FP2070TN-E: 800 x 480, WVGA, 7" color TFT with 4-wire analog resistive touch screen with 2 serial ports, one USB Type C port, one USB Host port & 1 Ethernet Port. It supports upto 3 expansions.
GETTING STARTED
User should follow the given sequence to configure and use any FlexiPanels series unit:
- Install FlexiSoft Software.
- Create a PZM application using FlexiSoft software.
- Connect programming cable.
- Download Firmware i.e. driver for the HMI.
- Download application.
- Now FP unit is ready to use in the system.
For More Information, Visit https://www.renuelectronics.com
SPECIFICATIONS
Specifications | Product Dimensions | |
---|---|---|
Power (Base) | 24VDC (+20%) @200mA, 4.8W (T-V2 module) |
7", 800 x 480 pixels, WVGA color TFT with 4-wire analog resistive touch screen |
Power | 24VDC (+20%, -15%) @230mA, 5.52W (TN-V2 module) | |
Power (With 3 Expansions) | 24VDC (+20%) @220mA, 5.28W (T-E type module) 24VDC (+20%) @250mA, 6W (TN-E type module) | |
Display | 7", 800 x 480 pixels, WVGA color TFT with 4-wire analog resistive touch screen | |
LEDs | 1 | |
RAM | 32MB max. | |
User Application | 8MB | |
Ladder Memory | 2MB | |
Alarm Memory | 1350 Alarms | |
Retentive Memory | 8000 Words | |
Data Log | 4MB | |
Keep Memory Registers | 1000 Words | |
Panel Cutout Dimensions | 127.00(H) x 175.00(W)mm | PANEL CUTOUT DIMENSIONS 175.0 127.0 R3.0(4X) 57.5 31.00 5.00 Panel Cutout Dimensions: 127(H) x 175.00(W)mm Panel Thickness: Maximum 6mm Mounting Clamps: 4 Tighten the mounting screws evenly to a torque between 0.4N/m to maintain water and dust resistance. |
Dimensions | 138(H) x 186.0(W) x 31.0(D)mm | 186.00 174.00 126.00 138.00 |
Weight | Approx. 400gm | |
Communication | 2 x RS232/RS485 | |
USB Ports | 1 USB Type C & 1 USB Host | |
SD card | Micro SD card supported (4 to 32 GB) | |
Ethernet | 1 Ethernet Port | |
Expansions* | Supports 3 Expansion slot | |
Environment & Approvals | Operating Temperature 0°C to 50°C Storage Temperature -30°C to 85°C Humidity 10 to 90% (Noncondensing) Shock 25g, 11ms, 6 shocks per axis, Total 18 shocks (X, Y, Z) Vibration 5~150Hz, 3g peak, (X, Y, Z) Protection Front panel-IP66, Rare panel-IP20 | |
APPROVALS | CE, UL (Class 1 DIV 2), UKCA, REACH& RoHS [*Note: Applicable only for FP2070Tx-E models. #Note -Applied for FP2070TN-V2 and FP2070TN-E model] |
Earthing
The optimum method for Earthing electronic equipment is to earth it separately from other high-power systems, to earth more than one unit of electronic equipment with a single-point earth. The Earthing marked terminal (see below) is provided on the unit.
DC+ DC- Earth
24Vdc
[Note: Do not use an earth that has an unstable impedance, such as painted screws or earth subject to vibration.]
COMMUNICATION
This section provides information regarding communication interfaces supported by this product.
COM1
FP2070Tx-E has one terminal block port (COM1) which support RS232 / RS485 signal levels.
2-wire RS485 pinout
Pin number | Signal |
---|---|
1 | TX+ |
2 | TX- |
3 | RX+ |
4 | RX+ |
5 | GND and Shield |
6 | RX- |
7 | NC |
8 | NC |
9 | TX- |
10 | RX- |
4-wire RS485 pinout
Pin number | Signal | Pin number | Signal |
---|---|---|---|
1 | TX+ | 1 | TX+ |
4 | RX+ | 4 | RX+ |
5 | GND and Shield | 5 | GND and Shield |
8 | TX- | 8 | TX- |
9 | RX- | 9 | RX- |
USB Type C Port
- USB Type C, compliant with USB 2.0 specification, self-powered device.
- Connector used: Micro USB Type C Female connector.
COM2
FP2070Tx-E has one DB9 female port (COM2) which support RS232 / RS485 signal levels.
Pin No. | Signal |
---|---|
1 | DB9 em(RS422/RS485) |
2 | TXD(RS232) |
3 | RXD(RS232) |
4 | RX+(RS422/RS485) |
5 | GND |
6 | NC |
7 | NC |
8 | TX-(RS422/RS485) |
9 | RX-(RS422/RS485) |
Cables:
RS232 pinout
Pin number | Signal | Pin number | Signal |
---|---|---|---|
2 | TXD | 2 | RXD |
3 | RXD | 3 | TXD |
5 | GND | 5 | GND |
Ethernet Port
- Fully compliant with IEEE 802.3 / 802.3u standards.
- 10/100 Mbps support.
- Connector used: Standard shielded RJ-45 female jack with in-built speed and link activity indication LEDs.
- Default IP Address: 192.168.0.254
- Default Subnet Activity Mask: 255.255.255.0
UL APPROVAL
CONTROL DRAWING NO# CNTL/DWG/FP2070/0218 | VER.NO.: 1.00 |
---|---|
Hazardous Location | Non-Hazardous Location |
Class I Division 2 Groups A B C and D | |
FP2070 | Associated Apparatus |
USB Port | |
JP5 V max = 3.3 VDC I max = 150 mA L = 0 C = 9 pF | Voc, Isc, La and Ca to be determined per Table 1 |
TABLE 1:
Nonincendive. Equipment | Associated Apparatus |
---|---|
V max (or Ui) | Voc or Vt (or Uo) |
I max (or Ii) | Isc or It (or Io) |
Ci + Ccable | Ca (or Co) |
Li + Lcable | La (or Lo) |
Capacitance and inductance of the field wiring from the nonincendive equipment to the associated apparatus shall be calculated and must be included in the system calculations as shown in Table 1. Where the cable capacitance and inductance per foot are not known, the following values shall be used: Ccable = 60 pF/ft., Lcable = 0.2 pH/ft. Wiring method must be in accordance with ANSI/NFPA70
REVISION HISTORY
Rev. | Description | Date |
---|---|---|
1.0 | First Draft | 14/08/2020 |
1.1 | Added Website Information | 27/08/2020 |
1.2 | Updated Communication Information | 07/09/2020 |
1.3 | Updated IP rating | 02/06/2021 |
1.4 | Replaced USB type from Micro to Type C | 11/10/2021 |
1.5 | Remove Micro USB Pinout dia | 08/12/2021 |
1.6 | Logo Updated | 20/09/2022 |
1.7 | Specification updated | 09/06/2025 |
RENU Electronics Pvt. Ltd® reserves the right to change or discontinue specifications and features without prior notice.