FP2070 SERIES

QUICK START GUIDE

Product Code

FP2070T-V2: 800 x 480, WVGA, 7" color TFT with 4-wire analog resistive touch screen with 2 serial ports, one USB Type C port & 1 USB Host port.

FP2070TN-V2: 800 x 480, WVGA, 7" color TFT with 4-wire analog resistive touch screen with 2 serial ports, one USB Type C port, one USB Host port & 1 Ethernet Port.

FP2070T-E: 800 x 480, WVGA, 7" color TFT with 4-wire analog resistive touch screen with 2 serial ports, one USB Type C port & 1 USB Host port. It supports upto 3 expansions.

FP2070TN-E: 800 x 480, WVGA, 7" color TFT with 4-wire analog resistive touch screen with 2 serial ports, one USB Type C port, one USB Host port & 1 Ethernet Port. It supports upto 3 expansions.

GETTING STARTED

User should follow the given sequence to configure and use any FlexiPanels series unit:

  1. Install FlexiSoft Software.
  2. Create a PZM application using FlexiSoft software.
  3. Connect programming cable.
  4. Download Firmware i.e. driver for the HMI.
  5. Download application.
  6. Now FP unit is ready to use in the system.

For More Information, Visit https://www.renuelectronics.com

SPECIFICATIONS

SpecificationsProduct Dimensions
Power (Base)24VDC (+20%) @200mA, 4.8W (T-V2 module)

7", 800 x 480 pixels, WVGA color TFT with 4-wire analog resistive touch screen

Power24VDC (+20%, -15%) @230mA, 5.52W (TN-V2 module)
Power (With 3 Expansions)24VDC (+20%) @220mA, 5.28W (T-E type module)
24VDC (+20%) @250mA, 6W (TN-E type module)
Display7", 800 x 480 pixels, WVGA color TFT with 4-wire analog resistive touch screen
LEDs1
RAM32MB max.
User Application8MB
Ladder Memory2MB
Alarm Memory1350 Alarms
Retentive Memory8000 Words
Data Log4MB
Keep Memory Registers1000 Words
Panel Cutout Dimensions127.00(H) x 175.00(W)mmPANEL CUTOUT DIMENSIONS
175.0
127.0
R3.0(4X)
57.5
31.00
5.00
Panel Cutout Dimensions: 127(H) x 175.00(W)mm
Panel Thickness: Maximum 6mm
Mounting Clamps: 4
Tighten the mounting screws evenly to a torque between 0.4N/m to maintain water and dust resistance.
Dimensions138(H) x 186.0(W) x 31.0(D)mm186.00
174.00
126.00
138.00
WeightApprox. 400gm
Communication2 x RS232/RS485
USB Ports1 USB Type C & 1 USB Host
SD cardMicro SD card supported (4 to 32 GB)
Ethernet1 Ethernet Port
Expansions*Supports 3 Expansion slot
Environment & ApprovalsOperating Temperature
0°C to 50°C
Storage Temperature
-30°C to 85°C
Humidity
10 to 90% (Noncondensing)
Shock
25g, 11ms, 6 shocks per axis, Total 18 shocks (X, Y, Z)
Vibration
5~150Hz, 3g peak, (X, Y, Z)
Protection
Front panel-IP66, Rare panel-IP20
APPROVALSCE, UL (Class 1 DIV 2), UKCA, REACH& RoHS [*Note: Applicable only for FP2070Tx-E models. #Note -Applied for FP2070TN-V2 and FP2070TN-E model]

Earthing

The optimum method for Earthing electronic equipment is to earth it separately from other high-power systems, to earth more than one unit of electronic equipment with a single-point earth. The Earthing marked terminal (see below) is provided on the unit.

DC+ DC- Earth
24Vdc

[Note: Do not use an earth that has an unstable impedance, such as painted screws or earth subject to vibration.]

COMMUNICATION

This section provides information regarding communication interfaces supported by this product.

COM1

FP2070Tx-E has one terminal block port (COM1) which support RS232 / RS485 signal levels.

2-wire RS485 pinout

Pin numberSignal
1TX+
2TX-
3RX+
4RX+
5GND and Shield
6RX-
7NC
8NC
9TX-
10RX-

4-wire RS485 pinout

Pin numberSignalPin numberSignal
1TX+1TX+
4RX+4RX+
5GND and Shield5GND and Shield
8TX-8TX-
9RX-9RX-

USB Type C Port

  1. USB Type C, compliant with USB 2.0 specification, self-powered device.
  2. Connector used: Micro USB Type C Female connector.

COM2

FP2070Tx-E has one DB9 female port (COM2) which support RS232 / RS485 signal levels.

Pin No.Signal
1DB9 em(RS422/RS485)
2TXD(RS232)
3RXD(RS232)
4RX+(RS422/RS485)
5GND
6NC
7NC
8TX-(RS422/RS485)
9RX-(RS422/RS485)

Cables:

RS232 pinout

Pin numberSignalPin numberSignal
2TXD2RXD
3RXD3TXD
5GND5GND

Ethernet Port

  1. Fully compliant with IEEE 802.3 / 802.3u standards.
  2. 10/100 Mbps support.
  3. Connector used: Standard shielded RJ-45 female jack with in-built speed and link activity indication LEDs.
  4. Default IP Address: 192.168.0.254
  5. Default Subnet Activity Mask: 255.255.255.0

UL APPROVAL

CONTROL DRAWING NO# CNTL/DWG/FP2070/0218VER.NO.: 1.00
Hazardous LocationNon-Hazardous Location
Class I Division 2 Groups A B C and D
FP2070Associated Apparatus
USB Port
JP5
V max = 3.3 VDC
I max = 150 mA
L = 0
C = 9 pF
Voc, Isc, La and Ca to be determined per Table 1

TABLE 1:

Nonincendive. EquipmentAssociated Apparatus
V max (or Ui)Voc or Vt (or Uo)
I max (or Ii)Isc or It (or Io)
Ci + CcableCa (or Co)
Li + LcableLa (or Lo)

Capacitance and inductance of the field wiring from the nonincendive equipment to the associated apparatus shall be calculated and must be included in the system calculations as shown in Table 1. Where the cable capacitance and inductance per foot are not known, the following values shall be used: Ccable = 60 pF/ft., Lcable = 0.2 pH/ft. Wiring method must be in accordance with ANSI/NFPA70

REVISION HISTORY

Rev.DescriptionDate
1.0First Draft14/08/2020
1.1Added Website Information27/08/2020
1.2Updated Communication Information07/09/2020
1.3Updated IP rating02/06/2021
1.4Replaced USB type from Micro to Type C11/10/2021
1.5Remove Micro USB Pinout dia08/12/2021
1.6Logo Updated20/09/2022
1.7Specification updated09/06/2025

RENU Electronics Pvt. Ltd® reserves the right to change or discontinue specifications and features without prior notice.

Models: FP2070 SERIES Analog Resistive Touch Screen, FP2070 SERIES, Analog Resistive Touch Screen, Resistive Touch Screen, Touch Screen

File Info : application/pdf, 2 Pages, 698.25KB

PDF preview unavailable. Download the PDF instead.

qs-manaul-fp2070-series-qs-r17

References

Microsoft Word 2010 Microsoft Word 2010

Related Documents

Preview FlexiPanels FP2 V2 Basic HMI Series Datasheet
Datasheet for the RENU FlexiPanels FP2 V2 Basic HMI series, featuring a 7" Color TFT display, analog resistive touch screen, and various communication options.
Preview Renu FlexiPanels FP2 V2 Basic HMI Series Datasheet
Datasheet for the Renu FlexiPanels FP2 V2 Basic HMI series, featuring a 7" TFT display, analog resistive touch screen, and various communication and environmental specifications.
Preview FP2070TN-LE2016RP-A0402U Quick Start Guide
This guide provides a quick start overview for the RENU FP2070TN-LE2016RP-A0402U HMI panel, detailing its specifications, product dimensions, panel cutout dimensions, and communication interfaces.
Preview FP2043 Series Quick Start Guide
A quick start guide for the FP2043 Series of devices, detailing specifications, communication interfaces, and getting started instructions.
Preview FP2070TN-LE2016RP-A0402U FlexiPanels FP2 HMI Datasheet
Detailed specifications and features of the RENU FlexiPanels FP2 FP2070TN-LE2016RP-A0402U, a 7-inch color TFT HMI with local and pluggable I/Os, offering advanced controller functions and robust connectivity.
Preview FlexiPanels FP2 V2 Basic HMI Series Datasheet
Datasheet for the RENU FlexiPanels FP2 V2 Basic HMI series, featuring a 4.3" color TFT display, RS232/RS485 communication, and industrial approvals.
Preview FlexiPanels FP2 V2 Basic HMI Series: Technical Specifications and Features
Explore the FlexiPanels FP2 V2 Basic HMI series, featuring a 4.3" color TFT display, robust connectivity options including RS232, RS485, USB, and Ethernet, and compliance with CE, UL Class I Div 2, RoHS, and IP66 standards. This document details model specifications, supported protocols, and application examples.
Preview Renu FP4070 Series Quick Start Guide
A quick start guide for the Renu FP4070 Series HMI, detailing specifications, product dimensions, communication interfaces, and UL approvals.