Page 1 of 14
№: PMC20191106001
NAME OF SAMPLE: Air Conditioner
APPLICANT: TCL Air Conditioner (Zhongshan) Co., Ltd.
CLASSIFICATION OF TEST: Commission Test
Testing Center of TCL Air Conditioner (Zhongshan) Co., Ltd.
59 Nantou Road West, Nantou, Zhongshan, Guangdong, China
Detail | Information |
---|---|
Applicant Name | TCL Air Conditioner (Zhongshan) Co., Ltd. |
Address | 59 Nantou Road West, Nantou, Zhongshan, Guangdong, China |
Manufacturer | TCL Air Conditioner (Zhongshan) Co., Ltd. |
Address | 59 Nantou Road West, Nantou, Zhongshan, Guangdong, China |
Factory | Same as applicant |
Product name | Air conditioner |
Trademark | TCL |
Model / type reference | TAC-12CS/X8 |
Rating and characteristics | 230V~60Hz |
Date of receipt of test item | 2019-11-06 |
Date(s) of test | 2019-11-06 |
Test specification/Standard | SASO 2663/2018, SASO GSO ISO 5151: 2010 |
To compile | Tan Minjie |
Audit | Wang Jia |
The director of the approval | Zhang Kaijie |
Date of issue | 2019-11-06 |
This report is for the exclusive use of TCL's Client and is provided pursuant to the agreement between TCL and its Client. TCL's responsibility and liability are limited to the terms and conditions of the agreement. TCL assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the TCL name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by TCL. This test report relates only to the tested product, and shall not be reproduced except in full, without written approval of TCL. This report by itself does not imply that the material, product, or service is or has ever been under an TCL certification program.
Test Case | Verdict |
---|---|
Test case does not apply to the test object | N.A. |
Test item does meet the requirement | Pass |
Test item does not meet the requirement | Fail |
Procedure deviation | N.A. |
Non-standard test method | N.A. |
The test results presented in this report relate only to the item tested.
The test report is invalid without the official stamp of TCL.
The test report is invalid without the signatures of Author and Reviewer.
No. | Description | Value |
---|---|---|
1 | Ratings | |
Rated voltage/rated voltage range (V) | 230 | |
Rated frequency (Hz) | 60 | |
Rated input (W) | Cooling (T1): 1021, Cooling (T3): 1269, Heating: N/A | |
Rated capacity (Btu/h) | Cooling (T1): 12100, Cooling (T3): 10600, Heating: N/A | |
Rated current (A) | N/A | |
2 | Type of power supply | ☑ Single phase, ☐ Three phase |
3 | Construction of the unit | ☑ Split type, ☐ Single packaged type, ☐ Multi-split type |
4 | Type of the unit considering if it has the air ducts | ☐ Spot, ☐ Single-duct, ☐ Double ducts |
5 | The number of the indoor units if multi-split type | |
6 | Type of the indoor unit if split type | ☑ Wall-mounted, ☐ Free-standing, ☐ Ceiling-mounted, ☐ Other type |
7 | Type of outdoor unit if split type | ☑ Free-standing, ☐ Other type |
9 | Supplementary heating element | ☐ Yes, ☑ No |
10 | Operation function | ☐ Cooling mode and heating mode, ☑ Cooling only, ☐ Heating only |
11 | Type of the refrigerant | As attached page |
12 | Mass of refrigerant (kg) | As attached page |
13 | Compressor information | As attached page |
The document includes images of two nameplates: one for the indoor unit and one for the outdoor unit of the TCL Split Type Air Conditioner.
The document displays two photographs of the tested air conditioner units. The first image shows the indoor unit, a white, wall-mounted appliance with a sleek design and a control panel. The second image presents the outdoor unit, a larger, rectangular white appliance with a prominent fan grille on the front, typical of an air conditioner condenser unit.
The document includes a photograph of the compressor label. The label provides the following information:
A small data matrix (QR code-like symbol) is also visible on the label.
Test Method | Parameter | Enthalpy Test Room Value |
---|---|---|
COOLING CAPACITY (T1) | Total cooling capacity in Btu/h | 12200 |
Air conditioner power consumption in W | 1010 | |
Energy Efficiency Ratio (EER) in Btu/h/W | 12.08 | |
Total cooling capacity in Btu/h | 10800 | |
COOLING CAPACITY (T3) | Air conditioner power consumption in W | 1260 |
Energy Efficiency Ratio (EER) in Btu/h/W | 8.57 | |
Total cooling capacity in W | / | |
HEATING CAPACITY | Air conditioner power consumption in W | / |
Energy Efficiency Ratio (COP) in W/W | / |
☑ Pass
Note: If failed, it shall be indicated which part it was fail in.
Category | Type | Detail |
---|---|---|
Brand | TCL | |
System (if application) | KT3F-31GW/YXA(E/6)(AVS00) | |
Model No. | Indoor (split system only) | / |
Outdoor (split system only) | / | |
Serial number | Indoor: G440N0200100IB130001 | Outdoor: G440W0200100IB130001 |
Air-Conditioner Type | Split air conditioner | |
Air Distribution | Two way (Up-down) | |
Type of system | R410A | Mass of Refrigerant (kg): 0.730 |
Heat transfer | Cooling only | |
Voltage(V) | 230 | |
Phase | 1ph | |
Hz | 60 | |
Compressor | Type | Hermetic motor-compressor |
Brand | RECHI | |
Model Name | 44M262UM&FJKE | |
Maker | RECHI PRECISION CO., LTD. | |
Country of Origin | China | |
Indoor Fan motor | Type | AC motor |
Brand | BROAD-OCEAN/Welling | |
Model | 210900056C | |
Maker | ZHONGSHAN BROAD-OCEAN MOTOR Co., LTD. Guangdong Welling Motor Manufacturing Co., Ltd | |
Country of Origin | China | |
Outdoor Fan motor | Type | AC motor |
Brand | BROAD-OCEAN/Welling | |
Model | 1170040127 | |
Maker | ZHONGSHAN BROAD-OCEAN MOTOR Co., LTD. Guangdong Welling Motor Manufacturing Co., Ltd | |
Country of Origin | China | |
Evaporator | Volume(mm) | 705mm x 315 mm x 25.4 mm |
Type | Hydrophilic & Louver Fin; Innergroover tube type | |
Condenser | Volume(mm) | 765mm x 510 mm x 23.2 mm |
Type | Louver or Corrugated Fin; Innergroover tube type | |
Refrigerant | Type: R410A | 730g |
Dimensions | Indoor(mm) | Width:910, Depth:294, Height:206 |
Outdoor(mm) | Width:817, Depth:328, Height:553 |
Parameter | Value |
---|---|
Test Duration (min) | 90 |
Power supplied | 220-240V |
Applied voltage (V) | 230.0 |
Frequency (Hz) | 60 |
Current (A) | 4.53 |
Power Consumption (W) | 1010 |
Power factor | 97.0% |
Fan speed settings | High speed |
Dry bulb temperature, indoor (°C) | 27.00 |
Wet bulb temperature, indoor (°C) | 19.02 |
Dry bulb temperature, outdoor (°C) | 35.01 |
Wet bulb temperature, outdoor (°C) | 24.00 |
Barometer (Pa) | 100.28 |
Indoor cooling capacity (Btu/h) | 12200 |
Sensible cooling capacity (Btu/h) | 9760 |
Latent cooling capacity (dehumidifying capacity) (Btu/h) | 2440 |
Static pressure (Pa) | 224 |
Volume flow rate of air (m³/hr) | 817 |
Cooling capacity (Btu/h) | 12200 |
EER (Btu/h)/W | 12.08 |
Parameter | Value |
---|---|
Test Duration (min) | 90 |
Power supplied | 220-240V |
Applied voltage (V) | 230.0 |
Frequency (Hz) | 60 |
Current (A) | 5.65 |
Power Consumption (W) | 1260 |
Power factor | 97.0% |
Fan speed settings | High speed |
Dry bulb temperature, indoor (°C) | 29.02 |
Wet bulb temperature, indoor (°C) | 19.00 |
Dry bulb temperature, outdoor (°C) | 46.01 |
Wet bulb temperature, outdoor (°C) | 24.02 |
Barometer (Pa) | 100.46 |
Indoor cooling capacity (Btu/h) | 10800 |
Sensible cooling capacity (Btu/h) | 9828 |
Latent cooling capacity (dehumidifying capacity) | 972 |
Static pressure (Pa) | 235 |
Volume flow rate of air (m³/hr) | 838 |
Cooling capacity (Btu/h) | 10800 |
EER (Btu/h)/W | 8.57 |
Operability Condition | Result |
---|---|
Operability at Maximum cooling conditions at T3 conditions | ☑ Tested, ☐ Declared; Result: ☑ Pass, ☐ Fail |
Minimum cooling at T3 conditions | ☑ Tested, ☐ Declared; Result: ☑ Pass, ☐ Fail |
Freeze-up drip at T3 conditions (non-ducted AC) | ☑ Tested, ☐ Declared; Result: ☑ Pass, ☐ Fail |
Condensate control and enclosure sweat performance | ☑ Tested, ☐ Declared; Result: ☑ Pass, ☐ Fail |
Mode | Indoor Air Temperature | Outdoor Air Temperature | Test Voltage | ||
---|---|---|---|---|---|
Dry Bulb | Wet Bulb | Dry Bulb | Wet Bulb | ||
Cooling mode (T1) | 27 | 19 | 35 | 24 | 230V, 60Hz |
Cooling mode (T3) | 29 | 19 | 46 | 24 | 230V, 60Hz |
Mode | Rated | Tested | Verifying | Required EER | Verdict |
---|---|---|---|---|---|
Cooling capacity, Btu/h | 12100 | 12200 | 0.8% | >=11495 | Pass |
Cooling power input, W | 1021 | 1010 | -1.1% | <=1072 | Pass |
EER, Btu/W h | 11.85 | 12.08 | 1.9% | >=11.80 | Pass |
Mode | Rated | Tested | Verifying | Required EER | Verdict |
---|---|---|---|---|---|
Cooling capacity, Btu/h | 10600 | 10800 | 1.9% | >=10070 | Pass |
Cooling power input, W | 1269 | 1260 | -0.8% | <=1333 | Pass |
EER, Btu/W h | 8.35 | 8.57 | 2.7% | >=8.30 | Pass |
Parameter | Rated | Tested | Verifying | Required | Verdict |
---|---|---|---|---|---|
Heating capacity, W | / | / | / | / | Pass |
Heating power input, W | / | / | / | / | Pass |
COP, W/W | / | / | / | / | Pass |
Estimated annual energy consumption (Kwh/Y): 2757
Energy class: (based on rated EER at T1) D
![]() |
TCL Air Conditioner Energy Labeling and Performance Test Report Comprehensive test report detailing the energy labeling and minimum energy performance requirements for TCL split-type air conditioners, including cooling capacity, power consumption, and energy efficiency ratios (EER) under various load conditions. |
![]() |
TCL Air Conditioner Test Report - Model TAC-30CHS/X8 This report details the rating and performance tests conducted on the TCL Split Type Air Conditioner, model TAC-30CHS/X8. It includes cooling and heating capacity tests, functional performance, and a summary of results against specified standards. |
![]() |
TCL Air Conditioner Product Identity Declaration This document is a Product Identity Declaration from TCL Air Conditioner (Zhongshan) Co., Ltd., confirming that various air conditioner models, including those under the TCL and RUUD brands, are identical in technical design, performance, energy consumption, and star rating. It lists specific model numbers along with their corresponding safety and EMC test report numbers. |
![]() |
Wall Mounted Split-Type Air Conditioners Service Manual Comprehensive service manual for wall-mounted split-type air conditioners, covering models TAC-07CHSA, TAC-09CHSA, TAC-12CHSA, TAC-18CHSA, and TAC-24CHSA. Includes product dimensions, refrigeration cycle diagrams, operation details, wiring diagrams, parts lists, troubleshooting, and protection codes. |
![]() |
TCL Split Type Air Conditioner Instruction Manual This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of TCL Split Type Air Conditioners. It covers safety precautions, parts identification, remote controller functions, operating modes, and technical specifications. |
![]() |
TCL Portable Air Conditioner FCC & ICES Test Report Official test report for TCL portable air conditioners (models TAC-10CHPD/NV, TAC-10CPD/NV, TAC-08CHPD/MZ) confirming compliance with FCC Part 15 Subpart B and ICES-003 standards, conducted by UL-CCIC Company Limited. |
![]() |
Inverter Air Conditioner Service Manual This service manual provides detailed technical specifications, operation details, and troubleshooting guidance for inverter air conditioners, including models TAC-09CHSA/XA71, TAC-12CHSA/XA71, TAC-18CHSA/XA71, and TAC-24CHSA/XA71. |
![]() |
TCL Inverter Air Conditioner Service Manual A comprehensive service manual for TCL Inverter Air Conditioners, detailing operation, installation, troubleshooting, and maintenance for models TAC-09CHSD/XAA1I, TAC-12CHSD/XAA1I, TAC-18CHSD/XAA1I, and TAC-24CHSD/XAA1I. |