Page 1 of 14

№: PMC20191106001

TEST REPORT

Air Conditioner Test Report Overview

NAME OF SAMPLE: Air Conditioner

APPLICANT: TCL Air Conditioner (Zhongshan) Co., Ltd.

CLASSIFICATION OF TEST: Commission Test

Testing Center of TCL Air Conditioner (Zhongshan) Co., Ltd.
59 Nantou Road West, Nantou, Zhongshan, Guangdong, China

The Rating and Performance Tests for Air-conditioner

DetailInformation
Applicant NameTCL Air Conditioner (Zhongshan) Co., Ltd.
Address59 Nantou Road West, Nantou, Zhongshan, Guangdong, China
ManufacturerTCL Air Conditioner (Zhongshan) Co., Ltd.
Address59 Nantou Road West, Nantou, Zhongshan, Guangdong, China
FactorySame as applicant
Product nameAir conditioner
TrademarkTCL
Model / type referenceTAC-12CS/X8
Rating and characteristics230V~60Hz
Date of receipt of test item2019-11-06
Date(s) of test2019-11-06
Test specification/StandardSASO 2663/2018, SASO GSO ISO 5151: 2010
To compileTan Minjie
AuditWang Jia
The director of the approvalZhang Kaijie
Date of issue2019-11-06

This report is for the exclusive use of TCL's Client and is provided pursuant to the agreement between TCL and its Client. TCL's responsibility and liability are limited to the terms and conditions of the agreement. TCL assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the TCL name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by TCL. This test report relates only to the tested product, and shall not be reproduced except in full, without written approval of TCL. This report by itself does not imply that the material, product, or service is or has ever been under an TCL certification program.

Test Case Verdicts and General Remarks

Test CaseVerdict
Test case does not apply to the test objectN.A.
Test item does meet the requirementPass
Test item does not meet the requirementFail
Procedure deviationN.A.
Non-standard test methodN.A.

General Remarks

The test results presented in this report relate only to the item tested.

The test report is invalid without the official stamp of TCL.

The test report is invalid without the signatures of Author and Reviewer.

Brief Description of the Tested Sample(s) - Ratings

No.DescriptionValue
1Ratings
Rated voltage/rated voltage range (V)230
Rated frequency (Hz)60
Rated input (W)Cooling (T1): 1021, Cooling (T3): 1269, Heating: N/A
Rated capacity (Btu/h)Cooling (T1): 12100, Cooling (T3): 10600, Heating: N/A
Rated current (A)N/A
2Type of power supply☑ Single phase, ☐ Three phase
3Construction of the unit☑ Split type, ☐ Single packaged type, ☐ Multi-split type
4Type of the unit considering if it has the air ducts☐ Spot, ☐ Single-duct, ☐ Double ducts
5The number of the indoor units if multi-split type
6Type of the indoor unit if split type☑ Wall-mounted, ☐ Free-standing, ☐ Ceiling-mounted, ☐ Other type
7Type of outdoor unit if split type☑ Free-standing, ☐ Other type
9Supplementary heating element☐ Yes, ☑ No
10Operation function☐ Cooling mode and heating mode, ☑ Cooling only, ☐ Heating only
11Type of the refrigerantAs attached page
12Mass of refrigerant (kg)As attached page
13Compressor informationAs attached page

Photo of Nameplate

The document includes images of two nameplates: one for the indoor unit and one for the outdoor unit of the TCL Split Type Air Conditioner.

Indoor Unit Nameplate Details:

Outdoor Unit Nameplate Details:

Photo of the Tested Sample

The document displays two photographs of the tested air conditioner units. The first image shows the indoor unit, a white, wall-mounted appliance with a sleek design and a control panel. The second image presents the outdoor unit, a larger, rectangular white appliance with a prominent fan grille on the front, typical of an air conditioner condenser unit.

Photo of Compressor

The document includes a photograph of the compressor label. The label provides the following information:

Warning Information:

  1. This compressor must be grounded.
  2. Terminal cover must be in place and secured whenever power is applied to this compressor.
  3. Failure to do so results in hazardous exposure to high voltage and other dangers.

A small data matrix (QR code-like symbol) is also visible on the label.

Summary of Test Results

Test MethodParameterEnthalpy Test Room Value
COOLING CAPACITY (T1)Total cooling capacity in Btu/h12200
Air conditioner power consumption in W1010
Energy Efficiency Ratio (EER) in Btu/h/W12.08
Total cooling capacity in Btu/h10800
COOLING CAPACITY (T3)Air conditioner power consumption in W1260
Energy Efficiency Ratio (EER) in Btu/h/W8.57
Total cooling capacity in W/
HEATING CAPACITYAir conditioner power consumption in W/
Energy Efficiency Ratio (COP) in W/W/

Test Result:

☑ Pass

Note: If failed, it shall be indicated which part it was fail in.

Sample Information

CategoryTypeDetail
BrandTCL
System (if application)KT3F-31GW/YXA(E/6)(AVS00)
Model No.Indoor (split system only)/
Outdoor (split system only)/
Serial numberIndoor: G440N0200100IB130001Outdoor: G440W0200100IB130001
Air-Conditioner TypeSplit air conditioner
Air DistributionTwo way (Up-down)
Type of systemR410AMass of Refrigerant (kg): 0.730
Heat transferCooling only
Voltage(V)230
Phase1ph
Hz60
CompressorTypeHermetic motor-compressor
BrandRECHI
Model Name44M262UM&FJKE
MakerRECHI PRECISION CO., LTD.
Country of OriginChina
Indoor Fan motorTypeAC motor
BrandBROAD-OCEAN/Welling
Model210900056C
MakerZHONGSHAN BROAD-OCEAN MOTOR Co., LTD. Guangdong Welling Motor Manufacturing Co., Ltd
Country of OriginChina
Outdoor Fan motorTypeAC motor
BrandBROAD-OCEAN/Welling
Model1170040127
MakerZHONGSHAN BROAD-OCEAN MOTOR Co., LTD. Guangdong Welling Motor Manufacturing Co., Ltd
Country of OriginChina
EvaporatorVolume(mm)705mm x 315 mm x 25.4 mm
TypeHydrophilic & Louver Fin; Innergroover tube type
CondenserVolume(mm)765mm x 510 mm x 23.2 mm
TypeLouver or Corrugated Fin; Innergroover tube type
RefrigerantType: R410A730g
DimensionsIndoor(mm)Width:910, Depth:294, Height:206
Outdoor(mm)Width:817, Depth:328, Height:553

Test Report - Cooling Capacity Test (T1)

Data to be recorded for Enthalpy cooling capacity tests

ParameterValue
Test Duration (min)90
Power supplied220-240V
Applied voltage (V)230.0
Frequency (Hz)60
Current (A)4.53
Power Consumption (W)1010
Power factor97.0%
Fan speed settingsHigh speed
Dry bulb temperature, indoor (°C)27.00
Wet bulb temperature, indoor (°C)19.02
Dry bulb temperature, outdoor (°C)35.01
Wet bulb temperature, outdoor (°C)24.00
Barometer (Pa)100.28
Indoor cooling capacity (Btu/h)12200
Sensible cooling capacity (Btu/h)9760
Latent cooling capacity (dehumidifying capacity) (Btu/h)2440
Static pressure (Pa)224
Volume flow rate of air (m³/hr)817
Cooling capacity (Btu/h)12200
EER (Btu/h)/W12.08

Test Record of Cooling Capacity Test (T3)

ParameterValue
Test Duration (min)90
Power supplied220-240V
Applied voltage (V)230.0
Frequency (Hz)60
Current (A)5.65
Power Consumption (W)1260
Power factor97.0%
Fan speed settingsHigh speed
Dry bulb temperature, indoor (°C)29.02
Wet bulb temperature, indoor (°C)19.00
Dry bulb temperature, outdoor (°C)46.01
Wet bulb temperature, outdoor (°C)24.02
Barometer (Pa)100.46
Indoor cooling capacity (Btu/h)10800
Sensible cooling capacity (Btu/h)9828
Latent cooling capacity (dehumidifying capacity)972
Static pressure (Pa)235
Volume flow rate of air (m³/hr)838
Cooling capacity (Btu/h)10800
EER (Btu/h)/W8.57

Functional Performance – Cooling

Operability ConditionResult
Operability at Maximum cooling conditions at T3 conditions☑ Tested, ☐ Declared; Result: ☑ Pass, ☐ Fail
Minimum cooling at T3 conditions☑ Tested, ☐ Declared; Result: ☑ Pass, ☐ Fail
Freeze-up drip at T3 conditions (non-ducted AC)☑ Tested, ☐ Declared; Result: ☑ Pass, ☐ Fail
Condensate control and enclosure sweat performance☑ Tested, ☐ Declared; Result: ☑ Pass, ☐ Fail

Capacity tests at below condition were considered in this report.

ModeIndoor Air TemperatureOutdoor Air TemperatureTest Voltage
Dry BulbWet BulbDry BulbWet Bulb
Cooling mode (T1)27193524230V, 60Hz
Cooling mode (T3)29194624230V, 60Hz

Conclusion

Cooling capacity test (for condition T1)

ModeRatedTestedVerifyingRequired EERVerdict
Cooling capacity, Btu/h12100122000.8%>=11495Pass
Cooling power input, W10211010-1.1%<=1072Pass
EER, Btu/W h11.8512.081.9%>=11.80Pass

Cooling capacity test (for condition T3)

ModeRatedTestedVerifyingRequired EERVerdict
Cooling capacity, Btu/h10600108001.9%>=10070Pass
Cooling power input, W12691260-0.8%<=1333Pass
EER, Btu/W h8.358.572.7%>=8.30Pass

Heating capacity

ParameterRatedTestedVerifyingRequiredVerdict
Heating capacity, W////Pass
Heating power input, W////Pass
COP, W/W////Pass

Estimated annual energy consumption (Kwh/Y): 2757

Energy class: (based on rated EER at T1) D

* Verifying limit for test T1

PDF preview unavailable. Download the PDF instead.

5E22A780-556A-42BB-AEDA-C82F20AC1491 Microsoft Word 2019

Related Documents

Preview TCL Air Conditioner Energy Labeling and Performance Test Report
Comprehensive test report detailing the energy labeling and minimum energy performance requirements for TCL split-type air conditioners, including cooling capacity, power consumption, and energy efficiency ratios (EER) under various load conditions.
Preview TCL Air Conditioner Test Report - Model TAC-30CHS/X8
This report details the rating and performance tests conducted on the TCL Split Type Air Conditioner, model TAC-30CHS/X8. It includes cooling and heating capacity tests, functional performance, and a summary of results against specified standards.
Preview TCL Air Conditioner Product Identity Declaration
This document is a Product Identity Declaration from TCL Air Conditioner (Zhongshan) Co., Ltd., confirming that various air conditioner models, including those under the TCL and RUUD brands, are identical in technical design, performance, energy consumption, and star rating. It lists specific model numbers along with their corresponding safety and EMC test report numbers.
Preview Wall Mounted Split-Type Air Conditioners Service Manual
Comprehensive service manual for wall-mounted split-type air conditioners, covering models TAC-07CHSA, TAC-09CHSA, TAC-12CHSA, TAC-18CHSA, and TAC-24CHSA. Includes product dimensions, refrigeration cycle diagrams, operation details, wiring diagrams, parts lists, troubleshooting, and protection codes.
Preview TCL Split Type Air Conditioner Instruction Manual
This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of TCL Split Type Air Conditioners. It covers safety precautions, parts identification, remote controller functions, operating modes, and technical specifications.
Preview TCL Portable Air Conditioner FCC & ICES Test Report
Official test report for TCL portable air conditioners (models TAC-10CHPD/NV, TAC-10CPD/NV, TAC-08CHPD/MZ) confirming compliance with FCC Part 15 Subpart B and ICES-003 standards, conducted by UL-CCIC Company Limited.
Preview Inverter Air Conditioner Service Manual
This service manual provides detailed technical specifications, operation details, and troubleshooting guidance for inverter air conditioners, including models TAC-09CHSA/XA71, TAC-12CHSA/XA71, TAC-18CHSA/XA71, and TAC-24CHSA/XA71.
Preview TCL Inverter Air Conditioner Service Manual
A comprehensive service manual for TCL Inverter Air Conditioners, detailing operation, installation, troubleshooting, and maintenance for models TAC-09CHSD/XAA1I, TAC-12CHSD/XAA1I, TAC-18CHSD/XAA1I, and TAC-24CHSD/XAA1I.