TCL

Report No.: PMC20240908008 | Page 1 of 15

TEST REPORT: Energy Labeling and Minimum Energy Performance Requirements for Air Conditioners

This report details the energy labeling and minimum energy performance requirements for air conditioners, conducted by the Testing Center of TCL Air Conditioner (Zhongshan) Co., Ltd.

General Information

FieldDetail
Name of SampleAir Conditioner
ApplicantTCL Air Conditioner (Zhongshan) Co., Ltd.
Applicant Address59 Nantou Road West, Nantou, Zhongshan, Guangdong, China
Classification of TestCommission Test
ManufacturerTCL Air Conditioner (Zhongshan) Co., Ltd.
Product NameAir conditioner
TrademarkTCL
Model / Type ReferenceIndoor unit: TAC-12CS/TPXI31; Outdoor unit: TAC-12CU/TPXI31
Rating and Characteristics230V~60Hz
Date of Receipt of Test Item2024-09-08
Date(s) of Test2024-09-08
Date of Issue2024-09-08
Test Specification/StandardSASO 2663:2021, SASO GSO ISO 5151: 2017, ISO 16358-1:2013/Cor 1:2013/AMD1:2019

This report is for the exclusive use of TCL's Client and is provided pursuant to the agreement between TCL and its Client. TCL's responsibility and liability are limited to the terms and conditions of the agreement. Only the Client is authorized to permit copying or distribution of this report in its entirety. Any use of the TCL name or its marks for sale or advertisement of tested material, product, or service must be approved in writing by TCL. This test report relates only to the tested product and shall not be reproduced except in full without written approval of TCL.

To check the authenticity of test reports and certification, please verify the TCL digital signature with the blue banner at the top of the test report. If the digital signature is not displayed, access http://hao.tcl.com/report to verify authenticity.

Test Case Verdicts and General Remarks

Test CaseVerdict
Test case does not apply to the test objectN.A.
Test item does meet the requirementPass
Test item does not meet the requirementFail
Procedure deviationN.A.
Non-standard test methodN.A.

The test results presented in this report relate only to the item tested.

The test report is invalid without the official stamp of TCL.

The test report is invalid without the signatures of Author and Reviewer.

Test Method

The following test methods were applied for cooling mode operations:

Note: If the three short beeps of the buzzer are not clearly heard, power off and operate again.

Brief Description of the Tested Sample(s)

Ratings and Specifications

ParameterValue
Rated Voltage/Range230 V
Rated Frequency60 Hz
Rated Input (Cooling T1 100% Load)1008 W
Rated Input (Cooling T1 50% Load)351 W
Rated Input (Cooling T3)1261 W
Rated Capacity (Cooling T1 100% Load)12000 Btu/h
Rated Capacity (Cooling T1 50% Load)6000 Btu/h
Rated Capacity (Cooling T3)11100 Btu/h
Rated Current4.4 A
Type of Power SupplySingle phase
Construction of the UnitSplit type
Type of Indoor UnitWall-mounted
Operation FunctionCooling only
Type of RefrigerantR410A
Mass of Refrigerant0.650 kg
Compressor Stages TypeVariable capacity unit

Nameplate Information

The nameplate for the indoor unit (TAC-12CS/TPXI31) indicates a cooling capacity of 12000 Btu/h (3.51 kW) for T1 and 11100 Btu/h (3.24 kW) for T3, with a current of 4.6A (T1) and 5.6A (T3). Rated power input is 1008W (T1) and 1261W (T3), and EER is 11.90 Btu/h/W (T1) and 8.80 Btu/h/W (T3). Indoor air volume is 750 m³/h. Maximum allowable pressure is 4.5MPa (discharge) and 1.9MPa (suction). Noise level is 46dB(A) and weight is 11kg. Rated voltage/frequency is 230V~/60Hz.

The nameplate for the outdoor unit (TAC-12CU/TPXI31) shows similar cooling capacities and EERs. Rated power input is 1008W (T1) and 1261W (T3). Maximum allowable pressure is 4.5MPa (discharge) and 1.9MPa (suction). Noise level is 55dB(A) and weight is 23kg. Refrigerant is R410A with a charge of 0.650kg. Outdoor unit water proof protection is IPX4.

Compressor Details

The compressor is a GMCC KSN98D31UEZW31, operating at 230V, 240Hz, and uses R32/R410A refrigerant. It is manufactured by GMCC Electromechanical (Zhejiang) Co., Ltd. The label includes a warning regarding refrigerant charging, stating that charging R32 or R410A does not depend on the compressor's label, and refers to the air conditioner's label for proper instructions. The compressor model is KT3F-35W/YXABP(E/6)(008786) and was manufactured in May 2023.

Summary of Test Results

The air conditioner underwent enthalpy test room evaluations for cooling capacity under various load conditions.

ConditionTotal Cooling Capacity (Btu/h)Power Consumption (W)Energy Efficiency Ratio (EER)
T1 100% Load12300101812.083
T1 50% Load599035516.873
T31130012758.863

Test Result: Pass

Detailed Cooling Capacity Test Data

The following tables summarize the key parameters recorded during the cooling capacity tests for T1 100% Load, T1 50% Load, and T3 conditions. Each test duration was 90 minutes, with a power supply of 230V~60Hz.

T1 100% Load Test Data

ParameterValue
Applied Voltage (V)230.0
Current (A)4.56
Power Consumption (W)1018
Power Factor97.0%
Fan Speed SettingsHigh speed
Dry Bulb Temperature, Indoor (°C)27.01
Wet Bulb Temperature, Indoor (°C)19.00
Dry Bulb Temperature, Outdoor (°C)35.03
Wet Bulb Temperature, Outdoor (°C)24.01
Barometer (KPa)100.75
Indoor Cooling Capacity (Btu/h)12300
Sensible Cooling Capacity (Btu/h)10750
Latent Cooling Capacity (Btu/h)1550
Air-static Pressure Difference (Pa)251
Volume Flow Rate of Air (m³/hr)755
Cooling Capacity (Btu/h)12300
EER (Btu/h)/W12.083

T1 50% Load Test Data

ParameterValue
Applied Voltage (V)230.0
Current (A)1.59
Power Consumption (W)355
Power Factor97.0%
Fan Speed SettingsHigh speed
Dry Bulb Temperature, Indoor (°C)27.01
Wet Bulb Temperature, Indoor (°C)19.00
Dry Bulb Temperature, Outdoor (°C)35.03
Wet Bulb Temperature, Outdoor (°C)24.01
Barometer (KPa)100.75
Indoor Cooling Capacity (Btu/h)5990
Sensible Cooling Capacity (Btu/h)5225
Latent Cooling Capacity (Btu/h)765
Air-static Pressure Difference (Pa)251
Volume Flow Rate of Air (m³/hr)755
Cooling Capacity (Btu/h)5990
EER (Btu/h)/W16.873

T3 Load Test Data

ParameterValue
Applied Voltage (V)230.0
Current (A)5.71
Power Consumption (W)1275
Power Factor97.0%
Fan Speed SettingsHigh speed
Dry Bulb Temperature, Indoor (°C)29.01
Wet Bulb Temperature, Indoor (°C)19.02
Dry Bulb Temperature, Outdoor (°C)46.00
Wet Bulb Temperature, Outdoor (°C)24.02
Barometer (KPa)100.82
Indoor Cooling Capacity (Btu/h)11300
Sensible Cooling Capacity (Btu/h)9350
Latent Cooling Capacity (Btu/h)1950
Air-static Pressure Difference (Pa)264
Volume Flow Rate of Air (m³/hr)756
Cooling Capacity (Btu/h)11780
EER (Btu/h)/W8.863

Functional Performance – Cooling

Various functional performance tests were conducted, with the following results:

TestResult
Operability at Maximum cooling conditions at T3Pass
Minimum cooling at T3 conditionsPass
Freeze-up drip at T3 conditions (non-ducted AC)Pass
Condensate control and enclosure sweat performancePass
Operability at 52 °CNon Relevant
Operability at minimum cooling conditionsNon Relevant
Freeze up air blockageNon Relevant
Freeze-up dripNon Relevant
Condensate controlNon Relevant
Enclosure sweat performancesNon Relevant

Capacity Tests at Below Condition

The capacity tests were conducted under the following indoor and outdoor air temperature conditions, with a test voltage of 230V, 60Hz:

ModeIndoor Air Temp. (Dry/Wet Bulb °C)Outdoor Air Temp. (Dry/Wet Bulb °C)
Cooling mode (T1 Full load)27 / 1935 / 24
Cooling mode (T1 Half load)27 / 1935 / 24
Cooling mode (T3)29 / 1946 / 24

Conclusion

The test report concludes with the following verified results for cooling capacity and energy efficiency:

ModeRated ValueTested ValueVerification (%)Required ValueRequired EER/MEPSVerdict
Cooling capacity, Btu/h (T1 100% Load)12000123002.50%>=11400--Pass
Cooling power input, W (T1 100% Load)100810180.99%<=1068--Pass
EER, Btu/W·h (T1 100% Load)11.912.0831.54%>=11.4011.4Pass
Cooling capacity, Btu/h (T1 50% Load)60005990-0.17%>=5700--Pass
Cooling power input, W (T1 50% Load)3453552.90%<=362--Pass
EER, Btu/W·h (T1 50% Load)17.216.873-1.90%>=16.3416.30Pass
Cooling capacity, Btu/h (T3)11100113001.80%>=10545--Pass
Cooling power input, W (T3)126112751.11%<=1324--Pass
EER, Btu/W·h (T3)8.8038.8630.68%>=8.368.30Pass

The report indicates no heating capacity data was recorded for the H1 condition.

Annual Energy Consumption (AEC): 2891 kWh

SEER: 15.20

SEER Class: B

* Verifying limits for test T1: Cooling capacity ≥ 0.95 x rated capacity; Cooling power input ≤ 1.05x rated; Heating capacity ≥ 0.95 x rated capacity; Heating power input ≤ 1.05x rated; EER ≥ 0.95 x rated; COP ≥ 0.95 x rated.

PDF preview unavailable. Download the PDF instead.

PMC20240908008 Microsoft Word 2016

Related Documents

Preview TCL TAC-12CS/X8 Air Conditioner Performance Test Report PMC20191106001
This test report details the rating and performance tests conducted on the TCL TAC-12CS/X8 Air Conditioner, including cooling capacities (T1 and T3 conditions), power consumption, energy efficiency ratios (EER), and compliance with SASO 2663/2018 and SASO GSO ISO 5151: 2010 standards. The report provides comprehensive data on the indoor and outdoor units, refrigerant, and compressor specifications, confirming the product's performance and energy class.
Preview TCL Air Conditioner Test Report - Model TAC-30CHS/X8
This report details the rating and performance tests conducted on the TCL Split Type Air Conditioner, model TAC-30CHS/X8. It includes cooling and heating capacity tests, functional performance, and a summary of results against specified standards.
Preview TCL Air Conditioner Product Identity Declaration
This document is a Product Identity Declaration from TCL Air Conditioner (Zhongshan) Co., Ltd., confirming that various air conditioner models, including those under the TCL and RUUD brands, are identical in technical design, performance, energy consumption, and star rating. It lists specific model numbers along with their corresponding safety and EMC test report numbers.
Preview Wall Mounted Split-Type Air Conditioners Service Manual
Comprehensive service manual for wall-mounted split-type air conditioners, covering models TAC-07CHSA, TAC-09CHSA, TAC-12CHSA, TAC-18CHSA, and TAC-24CHSA. Includes product dimensions, refrigeration cycle diagrams, operation details, wiring diagrams, parts lists, troubleshooting, and protection codes.
Preview TCL Split Type Air Conditioner Instruction Manual
This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of TCL Split Type Air Conditioners. It covers safety precautions, parts identification, remote controller functions, operating modes, and technical specifications.
Preview TCL Portable Air Conditioner FCC & ICES Test Report
Official test report for TCL portable air conditioners (models TAC-10CHPD/NV, TAC-10CPD/NV, TAC-08CHPD/MZ) confirming compliance with FCC Part 15 Subpart B and ICES-003 standards, conducted by UL-CCIC Company Limited.
Preview TCL Inverter Air Conditioner Service Manual
A comprehensive service manual for TCL Inverter Air Conditioners, detailing operation, installation, troubleshooting, and maintenance for models TAC-09CHSD/XAA1I, TAC-12CHSD/XAA1I, TAC-18CHSD/XAA1I, and TAC-24CHSD/XAA1I.
Preview Inverter Air Conditioner Service Manual
This service manual provides detailed technical specifications, operation details, and troubleshooting guidance for inverter air conditioners, including models TAC-09CHSA/XA71, TAC-12CHSA/XA71, TAC-18CHSA/XA71, and TAC-24CHSA/XA71.