TÜV Rheinland Test Report: BLOMPRAKT E2503

Test Report Number: CN24RVG1 001

Client: IKEA of Sweden AB

Test Item: BLOMPRAKT

Type Number: E2503

Order Date: 2024-09-04

Date of Receipt: 2024-09-29

Test Result: Pass

Tested By: Xuelan Zhang (Project Engineer)

Authorized By: Jacky Chen (Authorizer)

FCC ID: FHO-E2503

IC: 10912A-E2503

Test Firm: TÜV Rheinland (Shanghai) Co., Ltd.

Condition of Test Item at Delivery: Test item complete and undamaged.

Remarks

1. All test equipment used was calibrated according to the laboratory's calibration program and meets relevant standards. Traceability is ensured by the management system. Detailed information on test conditions, equipment, and measurement uncertainty is available upon request.

2. This document is digitally signed as contractually agreed. TÜV Rheinland has not verified legal or other requirements applicable to this document; this is the user's responsibility. Validity of the digital signature can be confirmed by a separate document upon request to the sales department (an environmental fee applies). Verification information is available at go.tuv.com/digital-signature.

3. Test clauses marked with * were subcontracted. Deviations from specifications or customer requirements are listed in the respective test clause.

4. The decision rule for conformity statements is based on the "Zero Guard Band Rule" and "Simple Acceptance" per ILAC G8:2019 and IEC Guide 115:2021, unless otherwise specified. Measurement uncertainty is not accounted for in the report.

Revision History

Report NumberIssue DateContents and Reason for Change
CN24RVG1 0012025-01-14Initial release.

General Product Information

2.1 Product Function and Intended Use: The EUT (equipment under test) is a BLOMPRAKT. Refer to the user's manual for further details.

2.2 Ratings and System Details:

  • Rated input: AC 100-240 V, 50-60 Hz; 250-140 mA
  • Output: Audio 10 W, Lighting 1 W
  • Protection class: II

2.3 Independent Operation Modes:

  1. Continuous playing 1 kHz audio signal by Bluetooth.
  2. Light on with dimming.

2.4 Description of Interconnecting Cables: None.

2.5 Noise Generating and Noise Suppressing Parts: Refer to the circuit diagram for details.

2.6 Highest Frequency Generated or Used: The highest frequency used in the EUT is 2.4 GHz.

2.7 Submitted Documents: Circuit diagram, user's manual, and rating label.

Test Set-up and Operation Modes

3.1 Principle of Configuration Selection: For emission testing, the EUT was configured to measure its highest possible emission level, with test conditions adapted per the instructions for use. Testing sequence: Radiated emission tests were performed from 2024-10-24 to 2024-10-30. Conducted emission tests were performed on 2024-10-24.

3.2 Equipment and Cable Arrangement:

The test setup involves different configurations for conducted and radiated emissions. For conducted emissions, the EUT is connected via a Line Impedance Stabilization Network (LISN) to the power supply, with an EMI receiver and computer monitoring. For radiated emissions, the EUT is placed on a table (0.8m high) at a distance of 3m from the measurement antenna, connected to an EMI receiver and computer.

3.3 Test Software: No special test software was used.

3.4 Special Accessories and Auxiliary Equipment: A Huawei STF-AL10 cell phone was used during the tests.

3.5 Countermeasures to achieve EMC Compliance: No special measures were employed beyond standard setup.

Conformity Decision Rule

For all EMI tests, compliance is determined by comparing measurement results directly with limits, without considering measurement uncertainties, as the uncertainties are less than the values specified in CISPR 16-4-2.

Test Results: Emission

5.1 Emission in the Frequency Range up to 30 MHz: Mains Terminal Continuous Disturbance Voltage

Date of Testing: 2024-10-24

Test Procedure: FCC 47 CFR Part 15, Subpart B:2023, ICES-003:2020, ICES-005:2018, ANSI C63.4-2014, CISPR 16-2-1

Frequency Range: 0.15 - 30 MHz

Limits:

  • Quasi-peak limit: 0.15 - 0.5 MHz: 66 to 56 dBμV (decreasing with frequency); 0.5 - 5 MHz: 56 dBμV; 5 - 30 MHz: 60 dBμV
  • Average limit: 0.15 - 0.5 MHz: 56 to 46 dBμV (decreasing with frequency); 0.5 - 5 MHz: 46 dBμV; 5 - 30 MHz: 50 dBμV

Bandwidth of EMI receiver: 9 kHz

Measurement Time: 1 s

Test Site: Shielded room

Input Voltage: AC 120 V, 60 Hz

Operational Mode: Modes 1+2

Ambient Condition: Temperature: 21.5 °C; Relative humidity: 48 %

Expanded Measurement Uncertainty (k=2): 2.33 dB

The minimum margin to the limit was 13.86 dB at 0.350250 MHz. The margin is higher than the expanded measurement uncertainty.

The measurement setup was performed in a shielded room according to ANSI C63.4-2014. Test receivers, quasi-peak detectors, and artificial mains networks (AMN) comply with CISPR 16-1 standards. The EUT was placed on a wooden support 0.8m from the AMN. Power supply lines (neutral and phase) were tested.

Spectral Diagrams and Measurement Results (Conducted Emission, 150 kHz – 30 MHz, Line L)

A spectral diagram illustrates the conducted emission levels. The following table presents the final Quasi-peak and Average measurement results:

Frequency (MHz)QuasiPeak (dBuV)Limit (dBuV)Margin (dB)Meas. Time (ms)Bandwidth (kHz)LineCorr. (dB)
0.32325036.7859.6222.841000.09.000L110.3
0.35025045.0958.9613.861000.09.000L110.3
0.44925032.1756.8924.721000.09.000L110.3
0.47400032.3056.4424.141000.09.000L110.3
0.50100031.5856.0024.421000.09.000L110.3
1.02750031.1656.0024.841000.09.000L110.7
Frequency (MHz)CAverage (dBuV)Limit (dBuV)Margin (dB)Meas. Time (ms)Bandwidth (kHz)LineCorr. (dB)
0.32550023.3849.5726.191000.09.000L110.3
0.35250033.9348.9014.981000.09.000L110.3
0.37275020.0748.4428.371000.09.000L110.3
0.47400017.5646.4428.881000.09.000L110.3
0.70575022.8546.0023.151000.09.000L110.3
1.76550022.4846.0023.521000.09.000L110.2

Spectral Diagrams and Measurement Results (Conducted Emission, 150 kHz – 30 MHz, Line N)

A spectral diagram illustrates the conducted emission levels. The following table presents the final Quasi-peak and Average measurement results:

Frequency (MHz)QuasiPeak (dBuV)Limit (dBuV)Margin (dB)Meas. Time (ms)Bandwidth (kHz)LineCorr. (dB)
0.32325030.5159.6229.111000.09.000N10.5
0.35025037.4758.9621.481000.09.000N10.4
0.44925025.3056.8931.591000.09.000N10.3
0.47400025.3356.4431.121000.09.000N10.2
0.50100024.4556.0031.551000.09.000N10.2
1.02750024.1556.0031.851000.09.000N10.4
Frequency (MHz)CAverage (dBuV)Limit (dBuV)Margin (dB)Meas. Time (ms)Bandwidth (kHz)LineCorr. (dB)
0.32550019.0549.5730.521000.09.000N10.5
0.35250029.2448.9019.661000.09.000N10.4
0.37275015.5748.4432.871000.09.000N10.4
0.70575016.7646.0029.241000.09.000N10.4
1.76550016.5046.0029.501000.09.000N10.5
4.76250012.7246.0033.281000.09.000N10.7

5.2 Emission in the Frequency Range above 30 MHz

5.2.1 Radiated emission (30 MHz - 1 GHz)

Result: Passed

Date of Testing: 2024-10-24~2024-10-30

Test Procedure: FCC 47 CFR Part 15, Subpart B:2023, ICES-003:2020, ICES-005:2018, ANSI C63.4-2014, CISPR 16-2-3

Frequency Range: 30 - 1000 MHz

Limits (3 m distance):

  • 30 – 88 MHz: 40 dBμV/m
  • 88 – 216 MHz: 43.5 dBμV/m
  • 216 – 1000 MHz: 46 dBμV/m

Bandwidth of EMI receiver: 120 kHz

Measurement Time: 1 s

Test Site: Semi-anechoic chamber

Operational Mode: Modes 1+2

Input Voltage: AC 120 V; 60 Hz

Ambient Condition: Temperature: 20.5 °C; Relative humidity: 45 %

Expanded Measurement Uncertainty (k=2): 5.40 dB

The minimum margin to the limit was 8.7 dB at 34.971250 MHz. The margin is higher than the expanded measurement uncertainty.

The radiated disturbance test was conducted in a semi-anechoic chamber with a 3m test distance. The EUT was placed on a 0.8m high wooden table. The table was rotated 360°, and the antenna height was varied from 1m to 4m to find maximum disturbance. Tests were performed with the antenna in horizontal and vertical polarizations.

A spectral diagram illustrates the radiated emission levels. The following table presents the final Quasi-peak measurement results:

Frequency (MHz)QuasiPeak (dBμV/m)Bandwidth (kHz)Height (cm)PolAzimuth (deg)Corr. (dB/m)Margin - QPK (dB)Limit - QPK (dBμV/m)
32.66750027.8120.000200.0H165.023.612.240.0
37.15375024.6120.000150.0H145.021.315.440.0
132.82000021.5120.000200.0H112.018.522.043.5
313.48250026.9120.000200.0H26.020.719.146.0
707.52000032.4120.000120.0H179.026.913.646.0
932.10000033.1120.000100.0H-14.028.912.946.0

Spectral Diagrams and Measurement Results, Vertical Polarization (30 MHz to 1 GHz)

A spectral diagram illustrates the radiated emission levels. The following table presents the final Quasi-peak measurement results:

Frequency (MHz)QuasiPeak (dBμV/m)Bandwidth (kHz)Height (cm)PolAzimuth (deg)Corr. (dB/m)Margin - QPK (dB)Limit - QPK (dBμV/m)
34.97125031.3120.000130.0V115.022.58.740.0
42.24625026.9120.000110.0V145.018.613.140.0
148.82500024.5120.000150.0V89.017.619.043.5
321.12125024.2120.000170.0V78.020.921.846.0
616.36500030.3120.000200.0V-25.027.015.746.0
883.60000033.2120.000200.0V-98.028.712.846.0

5.2.2 Radiated emission (Above 1 GHz)

Result: Passed

Date of Testing: 2024-10-24~2024-10-30

Port: Enclosure

Test Procedure: FCC 47 CFR Part 15, Subpart B:2023, ANSI C63.4-2014, CISPR 16-2-3, ICES-003:2020

Limit: Above 1 GHz, Peak limit: 74 dBμV/m; Average limit: 54 dBμV/m

Frequency Range: 1-18 GHz

Note: The upper frequency for radiated emission measurement is 12 GHz, but actual testing extended to 18 GHz as per FCC Part 15 §15.33(b)(1).

Bandwidth of EMI receiver: 1000 kHz

Measurement Time: 1 s

Test Distance: 3 m

Test Site: Semi-anechoic chamber

Operational Mode: Mode 1

Input Voltage: AC 120 V; 60 Hz

Earthing: No earthing

Ambient Condition: Temperature: 20.5 °C; Relative humidity: 45 %

Expanded Measurement Uncertainty (k=2): 5.08 dB

The minimum margin to the limit was 7.3 dB at 17979.281250 MHz. The margin is higher than the expanded measurement uncertainty.

The radiated disturbance test was conducted in a semi-anechoic chamber with a 3m test distance. The EUT was placed on a 0.8m high poly table. The table was rotated 360°, and the antenna height was varied from 1m to 4m. Tests were performed with the antenna in horizontal and vertical polarizations.

The spectral diagrams show measurement results with peak detector (indicated by red 'x') and average detector (indicated by blue '+'). The following tables present the final Peak and Average measurement results:

Spectral Diagrams and Measurement Results, 1-18 GHz, Horizontal Polarization

Frequency (MHz)MaxPeak (dBμV/m)Meas. Time (ms)Bandwidth (kHz)Height (cm)PolAzimuth (deg)Corr. (dB/m)Margin - PK+ (dB)Limit - PK+ (dBμV/m)
2414.71875049.01000.01000.000100.0H-180.0-15.725.074.0
2445.00000041.41000.01000.000100.0H-180.0-15.832.674.0
2473.15625039.71000.01000.000100.0H-180.0-15.834.374.0
7308.59375046.61000.01000.000100.0H-180.0-6.027.474.0
14418.31250051.21000.01000.000100.0H-180.03.422.874.0
17979.28125057.21000.01000.000100.0H-180.013.016.874.0
Frequency (MHz)Average (dBμV/m)Meas. Time (ms)Bandwidth (kHz)Height (cm)PolAzimuth (deg)Corr. (dB/m)Margin - AVG (dB)Limit - AVG (dBμV/m)
2414.71875030.61000.01000.000100.0H-180.0-15.723.454.0
2445.00000022.71000.01000.000100.0H-180.0-15.831.354.0
2473.15625023.21000.01000.000100.0H-180.0-15.830.854.0
7308.59375032.71000.01000.000100.0H-180.0-6.021.354.0
14418.31250039.21000.01000.000100.0H-180.03.414.854.0
17979.28125046.71000.01000.000100.0H-180.013.07.354.0

Spectral Diagrams and Measurement Results, 1-18 GHz, Vertical Polarization

A spectral diagram illustrates the radiated emission levels. The following tables present the final Peak and Average measurement results:

Frequency (MHz)MaxPeak (dBμV/m)Meas. Time (ms)Bandwidth (kHz)Height (cm)PolAzimuth (deg)Corr. (dB/m)Margin - PK+ (dB)Limit - PK+ (dBμV/m)
1497.78125032.91000.01000.000100.0V280.0-18.441.174.0
2465.71875035.51000.01000.000100.0V280.0-15.838.574.0
7202.34375048.71000.01000.000100.0V280.0-5.425.374.0
7953.53125048.51000.01000.000100.0V280.0-3.025.574.0
14201.56250051.51000.01000.000100.0V280.02.422.574.0
17956.43750058.11000.01000.000100.0V280.012.616.074.0
Frequency (MHz)Average (dBμV/m)Meas. Time (ms)Bandwidth (kHz)Height (cm)PolAzimuth (deg)Corr. (dB/m)Margin - AVG (dB)Limit - AVG (dBμV/m)
1497.78125020.91000.01000.000100.0V280.0-18.433.154.0
2465.71875022.61000.01000.000100.0V280.0-15.831.454.0
7202.34375033.11000.01000.000100.0V280.0-5.420.954.0
7953.53125035.51000.01000.000100.0V280.0-3.018.654.0
14201.56250038.01000.01000.000100.0V280.02.416.054.0
17956.43750045.21000.01000.000100.0V280.012.68.854.0

Photographs of the Test Set-Up

Refer to the test setup file.

List of Test and Measurement Instruments

Equip.DescriptionModelManufacturerLast DateDue Date
9061503Shielded enclosure10.055x3.605x3.000Frankonia08.11.202308.11.2028
9023229EMI test receiverESR3Rohde&Schwarz03.08.202403.08.2025
G1824248Dual display multimeterF45Fluke28.06.202428.06.2025
9062744EMI measurement softwareEMC32-E+(10.60.20)Rohde&SchwarzN/AN/A
G1830003Artificial mains networkENV432Rohde&Schwarz11.10.202411.10.2025
G18113783m semi-anechoic chamberSAC3Frankonia03.12.202303.12.2026
G1811391EMI test receiverESCIRohde&Schwarz17.10.202417.10.2025
G1811425Bilog antennaCBL 6112DTeseq20.04.202320.04.2026
9062745EMI measurement softwareEMC32-MEB (10.60.20)Rohde&SchwarzN/AN/A
G1822695Spectrum analyserFSP30Rohde&Schwarz15.07.202415.07.2025
G1825371PreamplifierEMC051845SETaiwan EMCI24.07.202424.07.2025
G1811417Log periodic antennaHL050Rohde&Schwarz19.04.202319.04.2026

List of Figures

  • Figure 1: Spectral Diagrams, Conducted Emission, 150 kHz – 30 MHz, L
  • Figure 2: Spectral Diagrams, Conducted Emission, 150 kHz – 30 MHz, N
  • Figure 3: Spectral Diagrams and measurement results, horizontal polarization (30 MHz to 1 GHz)
  • Figure 4: Spectral Diagrams and measurement results, vertical polarization (30 MHz to 1 GHz)
  • Figure 5: Spectral Diagrams and measurement results, 1-18 GHz, horizontal polarization
  • Figure 6: Spectral Diagrams and measurement results, 1-18 GHz, vertical polarization

End of test report.

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=8240855 Microsoft Word for Microsoft 365; modified using iTextSharp™ 5.5.13.3 ©2000-2022 iText Group NV (AGPL-version)

Related Documents

Preview IKEA BLOMPRAKT E2503 RF Test Report - FCC & IC Compliance
This report details the RF testing and compliance results for the IKEA BLOMPRAKT E2503 speaker, covering conducted and radiated emissions, band-edge, and power spectral density tests according to FCC and IC regulations.
Preview IKEA LED2405G8NA Self-Ballasted LED Lamp EMC Test Report
Comprehensive EMC test report for the IKEA LED2405G8NA self-ballasted LED lamp, detailing conducted and radiated emissions testing against FCC and IC standards. Includes test results, limits, and equipment specifications.
Preview TÜV Rheinland Test Report: IKEA BLOMPRAKT E2503 Bluetooth Speaker Compliance
This comprehensive test report from TÜV Rheinland details the compliance verification of the IKEA BLOMPRAKT E2503 speaker, covering Bluetooth and 2.4GHz proprietary functions against FCC and RSS standards.
Preview BLOMPRAKT E2503 RF Exposure Compliance Report
Details the Radio Frequency (RF) exposure compliance for the IKEA BLOMPRAKT E2503 device, including test results, product classification, and adherence to FCC and IC exposure limits.
Preview TÜV Rheinland EMC Test Report for IKEA LED Rope Light L2401
This document is a TÜV Rheinland EMC test report for the IKEA LED Rope Light, model L2401. It details conducted and radiated emission tests performed according to FCC Part 15 Subpart B and ICES-005 standards, confirming compliance.
Preview IKEA E2503 BLOMPRAKT Technical Specifications and Product Information
Detailed technical specifications, product information, and regulatory markings for the IKEA E2503 BLOMPRAKT smart home device. Includes input/output power, dimensions, FCC/IC IDs, and country versions.
Preview TÜV Rheinland Test Report: IKEA E2400-T Wireless Charger with Light (VÄSTMÄRKE)
This report details the EMC testing conducted by TÜV Rheinland for the IKEA E2400-T Wireless Charger with Light (VÄSTMÄRKE). It covers conducted and radiated emissions according to FCC and ICES standards.
Preview IKEA of Sweden AB Attestation Statement for FCC Filing - Not Covered Entity Applicant
Attestation statement from IKEA of Sweden AB confirming they are not a covered entity applicant for FCC filing purposes, referencing FCC ID FHO-E2503 and product BLOMPRAKT.