TÜV Rheinland EMC Test Report

Report Number: CN24D5Q6 001

Client: IKEA of Sweden AB

Product: LED rope light

Model/Type: L2401

FCC ID: FHO-L2401

Testing Laboratory: TÜV Rheinland (Shanghai) Co., Ltd.

Issue Date: 2025-02-17

General Product Information

The Equipment Under Test (EUT) is an ordinary LED rope light intended for lighting and similar applications. For detailed information, refer to the user's manual.

Ratings and System Details

  • Rated Input: DC 24 V, 200 mA
  • Rated Power: 5 W
  • Power Unit: IKEA of Sweden AB, Model ICPSW24-7-4
  • Power Unit Specifications: Input: AC 100-240 V, 50/60Hz, 0.11 A, 10 W; Output: DC 24 V, Max 0.29 A, Max 7 W

Independent Operation Modes

The basic operation modes are "Off" and "On" with a dimming function.

Description of Interconnecting Cables

No. Interface and Name Shielded or Not Specified Length (m)
1 DC power line Unshielded 3.5 m

Noise Generating and Noise Suppressing Parts

Refer to the circuit diagram for further information.

Highest Frequency Generated or Used

The highest frequency used in the EUT is 16 MHz.

Submitted Documents

Circuit diagram, user's manual, and rating label were submitted.

Test Set-up and Operation Modes

Test Facilities

Laboratory: TÜV Rheinland (Shanghai) Co., Ltd.

Address: Workshop14, North Half of Workshop 10 and Workshop 16, Pingqian (Taicang) Modern Industrial Park, No.525, Yuewang Lingang South Road, Shaxi, Taicang, Jiangsu, China.

The test equipment used complies with CISPR 16-1 series standards for radio interference measurement.

Principle of Configuration Selection

The EUT was configured to measure its highest possible emission level. Test conditions were adapted according to the instructions for use. Radiated emission tests were performed on 2024-12-31, and conducted emission tests were performed on 2025-02-01.

Equipment and Cable Arrangement

Conducted Emission Test Setup: A block diagram shows the Equipment Under Test (EUT) connected to a Line Impedance Stabilization Network (LISN). The LISN is connected to an EMI receiver. A computer is linked to the EMI receiver for data acquisition. A transformer and power supply are also part of the system.

Radiated Emission Test Setup: A block diagram shows the EUT placed on a support structure. An antenna is positioned to receive radiated emissions from the EUT. Both the EUT and antenna are connected to an EMI receiver. The diagram indicates typical distances for testing (e.g., 3 meters).

Test Software, Accessories, and Countermeasures

No special test software was used. No special accessories or auxiliary equipment were employed. No special measures were taken to achieve EMC compliance.

Conformity Decision Rule

For all EMI tests in this report, compliance with limits is determined by directly comparing measurement results with the corresponding limits. Measurement uncertainties are not considered as they are less than the specified values according to CISPR 16-4-2.

Conducted Emission Results (0.15 MHz - 30 MHz)

Tests were performed in a shielded room with AC 120 V, 60 Hz input voltage. The EUT operated in dimming modes.

Mode 1: Lighting on with max lighting output

Figure 1: Spectral Diagrams, Conducted Emission, 150 kHz – 30 MHz, Line L

This section presents spectral data for conducted emissions on the Line L for Mode 1. The data includes quasi-peak and average measurements against frequency, with corresponding limits and margins.

Frequency (MHz) QuasiPeak (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line Corr. (dB)
12.42375017.3560.0042.651000.09.000L110.8
5.75925023.6160.0036.391000.09.000L110.5
2.87925029.6856.0026.321000.09.000L110.2
1.43925030.3556.0025.651000.09.000L110.4
0.36375041.4058.6417.241000.09.000L110.3
0.16125054.8965.4010.501000.09.000L110.3
Frequency (MHz) CAverage (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line Corr. (dB)
12.42600011.4350.0038.571000.09.000L110.8
5.76150016.5250.0033.481000.09.000L110.5
0.48525018.8446.2527.401000.09.000L110.3
0.15225034.3555.8821.531000.09.000L110.3
2.81850021.3746.0024.631000.09.000L110.2
1.91850017.7746.0028.231000.09.000L110.1

Figure 2: Spectral Diagrams, Conducted Emission, 150 kHz – 30 MHz, Line N

This section presents spectral data for conducted emissions on the Line N for Mode 1. The data includes quasi-peak and average measurements against frequency, with corresponding limits and margins.

Frequency (MHz) QuasiPeak (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line Corr. (dB)
12.63075017.5060.0042.501000.09.000N11.1
5.24625021.9760.0038.031000.09.000N10.7
1.45500028.1356.0027.871000.09.000N10.4
2.84325029.0956.0026.911000.09.000N10.6
0.36375041.2758.6417.371000.09.000N10.4
0.16800054.5665.0610.501000.09.000N10.4
Frequency (MHz) CAverage (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line Corr. (dB)
12.41475010.7150.0039.291000.09.000N11.1
5.24625014.4150.0035.591000.09.000N10.7
0.46050017.5746.6829.111000.09.000N10.3
0.15225034.3055.8821.581000.09.000N10.2
2.77350020.4146.0025.591000.09.000N10.6
1.97925018.0046.0028.001000.09.000N10.5

Mode 2: Lighting on with min lighting output

Figure 3: Spectral Diagrams, Conducted Emission, 150 kHz – 30 MHz, Line L

This section presents spectral data for conducted emissions on the Line L for Mode 2. The data includes quasi-peak and average measurements against frequency, with corresponding limits and margins.

Frequency (MHz) QuasiPeak (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line Corr. (dB)
5.89875019.6760.0040.331000.09.000L110.6
3.96825020.4156.0035.591000.09.000L110.2
2.62050023.2956.0032.711000.09.000L110.1
0.97575024.4656.0031.541000.09.000L110.7
0.46500030.8756.6025.731000.09.000L110.3
0.15225032.7265.8833.161000.09.000L110.3
Frequency (MHz) CAverage (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line Corr. (dB)
6.31725012.6150.0037.391000.09.000L110.7
24.5467507.8250.0042.181000.09.000L111.1
0.15900021.2355.5234.291000.09.000L110.3
0.97575014.7346.0031.271000.09.000L110.7
0.46500021.9046.6024.711000.09.000L110.3
2.62050014.7046.0031.301000.09.000L110.1

Figure 4: Spectral Diagrams, Conducted Emission, 150 kHz – 30 MHz, Line N

This section presents spectral data for conducted emissions on the Line N for Mode 2. The data includes quasi-peak and average measurements against frequency, with corresponding limits and margins.

Frequency (MHz) QuasiPeak (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line Corr. (dB)
5.50050019.1560.0040.851000.09.000N10.7
3.98175020.4956.0035.511000.09.000N10.7
0.98025022.2456.0033.761000.09.000N10.4
2.67000022.2656.0033.741000.09.000N10.6
0.46725026.7056.5629.861000.09.000N10.2
0.15225032.6165.8833.271000.09.000N10.2
Frequency (MHz) CAverage (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line Corr. (dB)
5.93250011.5850.0038.421000.09.000N10.6
25.5030008.9150.0041.091000.09.000N11.6
0.15900020.7955.5234.721000.09.000N10.3
0.46725019.4446.5627.121000.09.000N10.2
2.57550014.2046.0031.801000.09.000N10.6
0.98025013.9646.0032.041000.09.000N10.4

Radiated Emission Results (30 MHz - 1000 MHz)

Tests were performed in a semi-anechoic chamber with AC 120 V, 60 Hz input voltage. The EUT operated in dimming modes.

Test Distance: 3 meters.

Limits (Quasi-Peak, 3m distance):

  • 30 – 88 MHz: 40 dBuV/m
  • 88 – 216 MHz: 43.5 dBuV/m
  • 216 – 1000 MHz: 46 dBuV/m

Measurement Uncertainty: 5.40 dB.

Minimum Margin: 9.8 dB at 30.242500 MHz.

Mode 1: Lighting on with max lighting output

Figure 5: Spectral Diagrams, Radiated Emission, 30 MHz – 1000 MHz, Horizontal Polarization

This section presents spectral data for radiated emissions in horizontal polarization for Mode 1. The data includes quasi-peak measurements against frequency, with corresponding limits and margins.

Frequency (MHz) QuasiPeak (dBuV/m) Bandwidth (kHz) Height (cm) Pol Azimuth (deg) Corr. (dB/m) Margin - QPK (dB) Limit - QPK (dBuV/m)
32.18250029.1120.000100.0H180.023.810.940.0
34.72875027.8120.000120.0H-67.022.612.240.0
40.79125024.6120.000140.0H124.019.315.440.0
106.63000023.8120.000150.0H-166.018.419.743.5
596.48000032.6120.000180.0H93.026.913.446.0
862.98750035.3120.000200.0H-180.028.810.746.0

Figure 6: Spectral Diagrams, Radiated Emission, 30 MHz – 1000 MHz, Vertical Polarization

This section presents spectral data for radiated emissions in vertical polarization for Mode 1. The data includes quasi-peak measurements against frequency, with corresponding limits and margins.

Frequency (MHz) QuasiPeak (dBuV/m) Bandwidth (kHz) Height (cm) Pol Azimuth (deg) Corr. (dB/m) Margin - QPK (dB) Limit - QPK (dBuV/m)
30.24250030.2120.000100.0V-180.024.79.840.0
36.06250027.5120.000120.0V79.021.912.540.0
69.64875020.2120.000140.0V-108.012.619.840.0
134.51750026.2120.000150.0V111.018.417.343.5
143.49000025.3120.000180.0V-162.018.018.243.5
842.73875035.0120.000200.0V180.028.811.046.0

Mode 2: Lighting on with min lighting output

Figure 7: Spectral Diagrams, Radiated Emission, 30 MHz – 1000 MHz, Horizontal Polarization

This section presents spectral data for radiated emissions in horizontal polarization for Mode 2. The data includes quasi-peak measurements against frequency, with corresponding limits and margins.

Frequency (MHz) QuasiPeak (dBuV/m) Bandwidth (kHz) Height (cm) Pol Azimuth (deg) Corr. (dB/m) Margin - QPK (dB) Limit - QPK (dBuV/m)
30.84875029.7120.000100.0H-180.024.410.340.0
34.60750027.9120.000120.0H59.022.712.140.0
70.13375019.7120.000140.0H-110.012.620.340.0
126.15125023.8120.000160.0H81.018.719.743.5
262.67875025.8120.000180.0H-145.020.920.246.0
872.68750035.3120.000200.0H180.028.710.746.0

Figure 8: Spectral Diagrams, Radiated Emission, 30 MHz – 1000 MHz, Vertical Polarization

This section presents spectral data for radiated emissions in vertical polarization for Mode 2. The data includes quasi-peak measurements against frequency, with corresponding limits and margins.

Frequency (MHz) QuasiPeak (dBuV/m) Bandwidth (kHz) Height (cm) Pol Azimuth (deg) Corr. (dB/m) Margin - QPK (dB) Limit - QPK (dBuV/m)
31.81875029.4120.000100.0V180.023.910.640.0
33.15250028.7120.000120.0V-57.023.411.340.0
61.04000020.4120.000140.0V135.012.819.640.0
134.03250024.7120.000150.0V-144.018.418.843.5
547.13125032.1120.000180.0V88.026.613.946.0
914.15500035.1120.000200.0V-180.028.810.946.0

List of Test and Measurement Instruments

Equipment Description Model Manufacturer Last Calibration Date Due Date
Shielded enclosure10.055x3.605x3.000Frankonia08.11.202308.11.2028
EMI test receiverESR3Rohde & Schwarz03.08.202403.08.2025
Dual display multimeterF45Fluke28.06.202428.06.2025
EMI measurement softwareEMC32-E+(10.60.20)Rohde & SchwarzN/AN/A
Artificial mains networkENV432Rohde & Schwarz11.10.202411.10.2025
3m semi-anechoic chamberSAC3Frankonia03.12.202303.12.2026
EMI test receiverESCIRohde&Schwarz17.10.202417.10.2025
Bilog antennaCBL 6112DTeseq20.04.202320.04.2026
EMI measurement softwareEMC32-MEB (10.60.20)Rohde & SchwarzN/AN/A

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=8082215 Microsoft Word for Microsoft 365; modified using iTextSharp™ 5.5.13.3 ©2000-2022 iText Group NV (AGPL-version)

Related Documents

Preview IKEA LED2405G8NA Self-Ballasted LED Lamp EMC Test Report
Comprehensive EMC test report for the IKEA LED2405G8NA self-ballasted LED lamp, detailing conducted and radiated emissions testing against FCC and IC standards. Includes test results, limits, and equipment specifications.
Preview BLOMPRAKT E2503 EMC Test Report - TÜV Rheinland
This report details the Electromagnetic Compatibility (EMC) testing conducted by TÜV Rheinland for the IKEA BLOMPRAKT E2503. It covers conducted and radiated emissions tests performed according to FCC 47 CFR Part 15, Subpart B:2023 and ICES-003:2020, ICES-005:2018 standards.
Preview IKEA LED Light Chain J2520 EMC Test Report - TÜV Rheinland
This report details the Electromagnetic Compatibility (EMC) testing conducted by TÜV Rheinland on the IKEA LED Light Chain, model J2520, according to FCC Part 15 and ICES-005 standards.
Preview IKEA SMÅSNÖRE L2401 LED Rope Light Specifications and Compliance
Technical specifications and regulatory compliance details for the IKEA SMÅSNÖRE L2401 LED rope light, including input voltage, power, certifications (UL, CSA, FCC), and manufacturer information.
Preview TÜV Rheinland Test Report: IKEA E2400-T Wireless Charger with Light (VÄSTMÄRKE)
This report details the EMC testing conducted by TÜV Rheinland for the IKEA E2400-T Wireless Charger with Light (VÄSTMÄRKE). It covers conducted and radiated emissions according to FCC and ICES standards.
Preview TÜV Rheinland Test Report for IKEA B2406 LED Lamp - EMC Compliance
This report details the Electromagnetic Compatibility (EMC) testing conducted by TÜV Rheinland on the IKEA B2406 LED Lamp, covering conducted and radiated emissions according to FCC and ICES standards.
Preview IKEA LED2418G3CF Self-Ballasted LED Lamp EMC Test Report
This report details the Electromagnetic Compatibility (EMC) testing conducted on the IKEA self-ballasted LED lamp, model LED2418G3CF, by TÜV Rheinland. It covers conducted and radiated emissions according to FCC and ICES standards.
Preview TÜV Rheinland EMC Test Report for IKEA LED Light Chain J2504
This report from TÜV Rheinland details the Electromagnetic Compatibility (EMC) testing performed on the IKEA LED light chain (Model J2504) according to FCC Part 15 Subpart B and ICES-005 standards. It includes conducted and radiated emission test results, equipment details, and test setup configurations.