VEVOR Air Heater KW 2.0, 5.0, 8.0 Manual

VEVOR

Contact: service@vevor.com

Call us:

Working Time: Mon-Fri 8:00 am to 5:00 pm

Contents

  1. Introduction
  2. Product information
  3. Installation
  4. Operation and Control Mode
  5. Circuit
  6. Fault, maintenance and service

I. Introduction

Application fields of heater

The air heater is not affected by the engine and will be installed in the following vehicles on the premise of following the heating power:

Purpose of heater

The heater cannot be applied in the following occasions regarding the regulations for functions:

Installation and operation safety instructions

Outlet of heating air: When the hot air pipeline is placed in the automobile, it should ensure that it is difficult to be contacted and prevent the personnel or materials from damages.

Exhaust system: When placing the exhaust pipe, we should note that the outlet of exhaust pipe should avoid the combustibles and prevent heating or burning the ground combustibles or loading cargos.

Safety instructions for installation and operation

The following measures should not be taken:

Fuel depot:

II. Product information

Complete sets of equipment and installation components of heater

Diagram showing various components of the heater system. Key components include: 1. Heater, 2. Metering oil pump, 3. Control switch, 4. Fixed clamp of exhaust pipe, 5. Output line (positive/negative), 6. Control element transmission line, 7. Exhaust pipe, 8. Combustion air duct, 9. Belting, 10. Dose pump bracket, 11-12. Deoiling pipe, 13. Air outlet hose clamp, 14. Deoiler, 15. Air intake grille, 16. Outlet housing, 17. Air duct, 18. Heater harness.

III. Product information

Technical parameters

Heater Model XL-AIRD5 XL-AIRD3
Level Rating Level Rating
Heating media Air Air
Heat rating Super High-level Middle-level Low-level Close Super High-level Middle-level Low-level Close
Calorific value (w) 5000 3500 2000 900 3000 2200 1600 900
Dielectric flux (kg/h) 185 150 110 60 150 120 60 24
Fuel consumption (L/h) 0.64 0.40 0.28 0.11 0.35 0.25 0.18 0.10
Electric power consumption (W) 40 24 13 7 24 16 10 7
Rated voltage 12V or 24V 12V or 24V
Lower limit under-voltage protection 10.5V or 21V 10.5V or 21V
Lower limit overvoltage protection 16V or 32V 16V or 32V
Environmental temperature, heater When operating: -40°C to +40°C
Non operating: -40°C to +50°C
Non operating: -40°C to +85℃ When operating: -40°C to +40°C
Non operating: -40°C to +50°C
Non operating: -40°C to +85℃
Inlet temperature of hot air +40°C (highest) +40°C (highest)
Weight About 4.5kg About 3kg

Product dimension

Diagram showing the dimensions of the heater. The XL-AIRD5 model has a length of 376mm (375mm), width of 140mm, and height of 132.5mm. It features four M6 mounting holes. The XL-AIRD3 model has an overall length of 326mm, with other dimensions being the same as XL-AIRD5. The diagram also indicates A=Waste gas and B=Fuel.

1. It is used in minimum installation space to open cover, dismantle ignition plug and controller.

2. It is used in the minimum installation distance to draw the heating air.

III. Installation

Installation position

Fasten the heater on the bottom of vehicle or the vehicle wall with four screws on the stand bar of heater. When installing the heater, enough operation space should be reserved in the air inlet and the place to dismantle ignition plug and controller. (The suggested installation position and methods are shown as follows).

Installation position within truck

Within the truck, the heater will be installed in the driving cab.

  1. The heater is located in the front of co-pilot.
  2. The heater is located between driver's seat and co-pilot seat.
  3. The heater is located under the undersurface.
  4. The heater is located under the back seat.
  5. The heater is located in the luggage.

Installation position within RV

Within the RV, the heater is mainly installed in the room or luggage. The heater may also be fastened on the vehicle bottom, but it should prevent the water spraying.

  1. The heater is located at the foot of co-pilot.
  2. The heater is located at the back wall of driving cab.
  3. The heater is located at the back of driver's seat.
  4. The heater is located in the toolkit.
  5. The heater is located in the luggage.

Installation position in car/large car

In car/large car, the heater mainly is installed in the vehicle's passenger room or luggage.

  1. The heater is located in the front of co-pilot.
  2. The heater is located between driver's seat and co-pilot seat.
  3. The heater is located in the bottom.
  4. The heater is located under the counter.
  5. The heater is located in the luggage.

Installation position in the driving cab of excavator

If unable, the heater may be fastened under the vehicle, but we should note the water spraying.

  1. The heater is located in the box at the driver's seat.
  2. The heater is located at the back wall of driving cab.
  3. The heater is located in the protection case.

III. Installation

Installation angle and fastening

Allowable installation angle

As shown in the figure, the normal angle should be used to install the heater. According to different installation conditions, the heater may incline 30° (the flowing direction is downward) at most or rotate 90° around the long axis. (Exhaust pipe position, the ignition plug is upward).

Diagram showing installation angles and component orientation. Shows 1. Inlet of heating air, 2. Position of ignition plug, 3. Flow directions. The heater can be inclined up to 30° or rotated 90°.

Assembly and fastening

The holes used to process waste gas, combustion air and fuel pipe. The mounting face of heater legs should be flat.

Diagram showing assembly and fastening. Shows fastening the heater on the vehicle bottom or horizontally on the vehicle wall. Notes: 1. Ensure space between heater and vehicle bottom. 2. Assembly surface should be flat. 3. Sealing gasket should be assembled. 4. Vehicle wall should be flat. 5. Reinforcement plate (if necessary). 6. Spring sheet. 7. M6 hexagon nut.

Installation of combustion air duct and exhausting device

Guiding device of combustion air

The installation components contain a Flexible combustion air hose with an inner diameter of 25mm. According to installation conditions, the length of the combustion air duct may be shortened to 30cm or prolonged to 1m at most. Fasten the combustion air duct on the heater with a hose clamp. Another end is fastened with a ribbon to prevent shaking and falling.

Diagram illustrating the combustion air duct installation. Shows a flexible hose, hose clamp, and exhaust pipe. Length range is 0.3m-1m.

Safety instructions for guiding device of combustion air

Exhausting device

The installation components should contain one exhaust pipe with an inner diameter of 24mm. According to installation conditions, the length of the exhaust pipe may be shortened to 30cm or prolonged to 1m at most. Fasten one end of the exhaust pipe to the heater with a hose clamp and fasten the other end on the vehicle with a support.

Diagram illustrating the exhaust system. Shows components: 1 & 2. Hose clamp, 3. Exhaust pipe, 4. Combustion air pipe, 5. Inlet and outlet, 6. Sleeve of waste gas pipe, 7. Clip of inlet pipe.

Safety instructions for exhausting device

In the whole operation process from heating, all parts of the waste gas exhaust device will be burnt. Therefore, be sure to install the exhausting device according to the installation instructions.

Protection instructions

It will produce heat and toxic gas during burning time. Please install the exhausting device according to the installation instructions.

III. Installation

Installation notes for heating air duct

Heating air duct

The installation components contain one flexible pipe that the diameter is 75mm.

Safety instructions

Notes

Fuel supply

Installation angle of dose oil

When installing dose oil, note that the nozzle should be upward. The installation angle should be larger than 15°. The installation angle between 15° and 35° should be given priority. As shown in the figure below:

Diagram showing allowable angles for dose oil installation. Angle should be upward. Priority is given to angles between 15°-35°. 0°-15° is not allowed. 35°-90° is allowed.

Connection of oil pipe

When connecting the oil pipe, after inserting heater oil nozzle, pump oil nozzle, oil taker and T-shaped TEE oil nozzle into the rubber hose, it should be connected to the oil pipe in the next end to prevent bubbles in the oil channel, or it will produce noise and influence the combustion effect.

Diagrams showing correct and wrong oil pipe connections. Also shows T-shaped TEE parts. 1. Correct connection; 2. Wrong connection forming bubbles. 1. From oil tank; 2. Lead to auto engine.

Take oil from oil tank near to the oil channel of auto engine with T-shaped TEE parts.

Diagram showing how to take oil from the oil tank to the auto engine oil channel using T-shaped TEE parts.

Components shown: 1. Intake grille protection, 2. Outlet housing, 3. Hose clamp, 4. Soft air duct.

III. Product information

Deoiling Installation Diagram of Deoiler

Diagram illustrating the deoiling installation. Components shown: 1. Deoiler, 2. Connecting hoses, 3. Dosage oil pump, 4. Deoiling pipe, 5. Connecting hose, 6. Oil pipe.

Safety Instructions of Deoiling Pipe Laying

In order to avoid the oil pipe destroy or give rise to noise due to the vibration, the oil pipe shall be fixed firmly.

Please install all oil supply equipment, then, check the adapting pieces and the oil leakage phenomenon after heater has been started and operated for a certain period of time.

The oil pump which is installed on the vehicle will be prohibited to provide oil for the heater.

Operating Requirements of T-shaped Triple Valve Body

In order to avoid the fuel oil injection in the heater and the huge risks under the high pressure of vehicle oil pump, the triple valve body shall be installed between the vehicle oil pump and oil tank, instead of between the vehicle oil pump and engine. The vehicles of which the vehicle oil pump is installed in the oil tank shall apply the deoiler, instead of T-shaped triple valve body, to extract the oil.

Oil Circuit Maintenance and Overhaul Precautions

Please check whether the adapting pieces of oil circuits have become flexible before using the heater in winter. Check whether the connecting hose and oil pipe have become aging. Check whether the connection between the oil circuits have suffered from electric leakage when the heater has been operated for a certain period of time. Any problems found should be solved promptly.

When the heater is used for the first time, the heater is likely to be unable to be started during the early several launching due to the long-term unused behaviors. This is the normal phenomenon, at this moment, please start it for several times until the oil pump can suck up the fuel oil.

IV. Operation and Control Mode

Fuel filling

You shall infill the oil circuit via the fuel oil infilling function when you have installed heater host, oil circuit and electric circuit, otherwise, the heater is likely to fail to be started due to the fuel oil absence in the oil circuit.

The fuel oil shall be refueled in the following way: Press the rocker switch for 8 times continuously at the following frequency after connecting the power line correctly, namely, open it for 1 second and close it for 1 second. At this moment, the heater will start the fuel oil heating procedures to continuously send out the drive pulse of fuel metering pump and keep it for 5 minutes. During that period, the indicator on the rocker switch will flicker at the one-second on and one-second out frequency, moreover, the buzzer will make beep. You shall pay continuous attention to the fuel oil's position in the oil circuit during the refueling period of fuel oil. When the fuel oil has approached the heater oil inlet for 10cm, please turn off the rocker switch to stop the refueling process.

V. Circuit

Wiring of heater

Safety instructions

It is requested to realize the electrical connection of heater according to the electromagnetic compatibility principle.

Considering that the electromagnetic compatibility will be affected by the misoperation, please abide by the following requirements:

Notes

Please pay attention to the following affairs when the electric wiring and element operation are conducted for the heater:

Diagram of the main control board wiring. Lists connections for Red (1.5mm) positive/negative battery, oil pump, communication, storage battery, indicator, temperature sensor, draught fan, rocker switch, ignition plug, wind turbine, plug A/B, safe electric current. Also lists connections for the main control board itself.

VI. Fault, maintenance and service

Fault and handling

The heater cannot start upon startup:

The heater still does not start, the following should be checked:

The heater is likely to be out of order when the heater is used abnormally. The general using conditions, faults and disposing methods will be listed below.

Item Unit Minimum value Normal value Maximum value
Rated voltage V 21 27 32
Rated voltage A current A 0.06 2 10
dB 35 55 65
Movement
Noise
Fuel oil consumption L/hr 0.138 - 0.472
Recirculating wind flow cfm 30 - 85

Maintenance instructions

Service

When you have any technical problem or your heating equipment is out of order, please contact with the sales installers in time.

After-sales Warranty

Dealer: ____________________

User's name: ____________________ Contact No.: ____________________ MM/DD/YY: ____________________

Fault Code Description

Machine fault Status display Solution
Undervoltage power source Panel display E-01 Raise the power supply voltage
Overvoltage power source Panel display E-02 Reduce the power supply voltage
Ignition plug fault Panel display E-03 Check whether the ignition plug is open-circuit or short-circuit
Oil pump fault Panel display E-04 Check whether the oil pump is disconnected or short-circuit
Machine overheat Panel display E-05 Check the temperature sensor on the shell, or check whether the fan revolution speed is abnormal
Motor fault Panel display E-06 Check the polarity of the magnet and the position of the Hall sensor.
Disconnection fault Panel display E-07 Check the connecting plug to the panel, and verify whether the connection of the blue communication line is abnormal
Flame extinguishment Panel display E-08 Check whether the oil circuit has air or blockage, check whether the shell temperature sensor is malfunctioning, or whether the contact of the socket terminal is abnormal.

The contents in the table are subject to the digital panel. Faults of the panel with remote control function are identical with the description in the above table. Faults of the panel with knob control are identical with the description in the above table, but the display mode of fault is indicated by the times of blinking of an indicators.

12V-24V Common Digital Panel Operation Instruction

1. Indicators

2. Key Function

Description of Setting Parameters (Press the Set Key to Enter)

  1. Time setting: Use the up/down keys to adjust the parameter. Press the OK key, and consecutively set the Hour (24-hour system) and the Minute, and press the OK key to proceed to the next parameter.
  2. Timed startup and shutdown setting: It is off by default, displaying 1-OF; press the up arrow key to activate it, displaying 1-on. Press the OK key to consecutively set the first group of startup/shutdown time values and the second group of startup/shutdown time values, and then press the OK key again to proceed to the next parameter.

Admin password input

Press the up/down arrow keys, and when the correct value appears, press the OK key to proceed to the next digit. After all four digits are input correctly, press the OK key again to proceed to the next parameter.

3. Pump oil volume setting

Press the up/down keys to modify the minimum pump volume, and press the OK key when the required value is set.

4. Fan revolution speed setting

Press the up/down arrow keys to modify the minimum fan revolution speed, and press the OK key when the required value is set.

5. Operating voltage setting

The main board's operating voltage can only be adjusted under the shutdown status. Press the up/down arrow keys to switch the operating voltage to the 12V system (displaying U-12) or to the 24V system (displaying U-24). (Before startup, please check whether the oil pump, the motor and the ignition plug are suitable to each other, to avoid damage).

6. Revolution speed signal selection

Press the up/down arrow keys to set the revolution speed signal. Select 1 if the vane wheel has two magnets with the opposite polarity or has only one magnet. Please select 2 if the vane wheel has two magnets with the same polarity. If the parameter is incorrect, 1-fold speed error will occur.

7. Admin password modification

By default, the OFF status is displayed. Press the OK key if no modification is needed, to skip the password modification and automatically quit after saving the parameters. Press the up arrow key, and when the ON status is displayed, press the OK key to enter the modification status, and input a 4-digit new password, and press the OK key again to save the new password and the adjusted parameters for automatic quit.

Description of Machine Status Query

Under the non-setting status, press the OK key to view cyclically.

Manual Fuel Filling Description

Under the non-setting status, first press and hold the down arrow key, and then press the OK key simultaneously to enter the manual oil pumping interface. When H-OF is displayed, first release the OK key, and then release the down arrow key. Press the up arrow key to activate manual oil pumping, H-ON will be displayed and you will hear the oil pumping noise. Simply press the down arrow key or the Set key to deactivate it and quit the manual oil pumping.

Timed Startup/Shutdown Description

After setting the run time, press the OK key to enter the timed startup/shutdown setting function. By default, OF indicates the off status, and please press the up arrow key to activate the ON status, then you can press the OK key the set the first group of values, with the hour and minute values for the startup to be set first, and secondly enter and set the hour and minute values for the shutdown if the values for the startup are set. Then, press the OK key to enter the second group of values, with similar setting measures as those of the first group. You may specify an interval between the two groups of values. The timing function can only be performed once upon each setting, i.e. if the set timing values are performed, they will be invalid, and you need to reactivate the timing function and set new values for the timing.

Temperature Control Mode Switchover Description

Under the non-setting status, first press and hold the up arrow key, and then press the Set key simultaneously, if the panel displays P-xx (xx indicates pump oil volume), it indicates that you have entered the manual temperature control mode and the pump oil volume for operation is restrained within a range between the current pump oil volume and the initial pump oil volume. When you press the above mentioned keys simultaneously and the panel displays xx °C (xx indicates temperature value), it indicates that you have entered the automatic temperature control mode and the pump oil volume for operation is restrained within a range between the maximum pump oil volume and the initial pump oil volume. Under the two modes, the automatic changes of pump oil volume both depend on the variation of the temperature, but the difference between the two modes is that, under the automatic mode, the pump oil volume can reach the maximum value set for the parameter, which leads to higher temperature of the machine; under the manual mode, the pump oil volume is limited to the current setting value and can not reach the maximum value set for the parameter, thus the equipment's temperature is limited to the selected range, which is more adaptable to certain old-fashioned drivers.

The instructions on the LCD panel

Diagram of the LCD panel showing various indicators: Time display, Ambient temperature display, Set temperature display (automatic temperature control)/set oil mass display (manual temperature control), Historical fault code display, Power supply voltage display, Altitude display. The panel has buttons labeled 'OK', 'Set', '⬆️', '⬇️', 'ON/OFF'.

Warnings

  1. The fixed backboard shall be sealed and separated from the vehicle sheet metal during installation to avoid the physical injury to the driver when the combustion gas flows in the driving cab from the gap.
  2. The exhaust pipe length shall be 30cm at least.
  3. The exhaust gas outlet shall be firmly placed in the empty space.
  4. The exhaust pipe outlet shall not look at the driving direction.

Recommendations

It is suggested to apply the sealant to block off the installation gap when the heater has been fixed.

Instructions for Use of 12V-24V General LCD Panel

1. Button function

2. Query machine status (keep short press of the Confirm button to switch one state at a time to make it display cyclically)

3. Description of fuel filling in manual mode

Under the shutdown state, press the down-regulation button and On/Off button simultaneously to conduct fuel filling manually, which displays ⛽, and after releasing, press up-regulation button and it displays ⛽, the oil pump starts to work. You can hear the sound of the oil pump working and the oil pump icon lights up. Press down-regulation button to display ⛽, exit fuel filling, the oil pump icon disappears. The process of line air evacuation shall be done under watch, when the oil reaches the position of the oil inlet of the machine, it can be stopped. If there is too much oil enters the machine, there will be black smoke when igniting.

4. Description of temperature control mode switching

Press the up-regulation button and On/Off button simultaneously to conduct temperature control mode switch. There are manual temperature control mode (oil mass adjustment ?️ shows, number represents the oil mass) and automatic temperature control mode (temperature adjustment ?️ shows, number represents the temperature). The difference between two modes is that: in automatic mode, pump oil amount can reach the maximum upon parameter setting and the machine heat is higher, the manual pump oil amount is limited to the current setting value and will not reach the maximum oil value set by the parameter, which makes gears clearly shown and is very convenient for the part old hands.

5. Description of remote control code matching

In the shutdown state, long press the LCD panel down-regulation button. Enter the remote control code matching interface to make it display, then press the On button of remote control to transmit the remote control code, and successful code matching will make it automatically exit the code interface. If the code matching fails, it will not enter the start-up state. The code matching state will be automatically exited when it does not receive remote control code over time.

6. Description of parameter setting procedure (press setting button to enter setting state)

  1. Time setting: Press the up-regulation button or down-regulation button to adjust parameters setting parameters of hour (24-hour system) and minute in turn, and press confirm button to confirm the parameters to enter the next item.
  2. Timed start-up setting: Closed by default, it shows OFF. Press up-regulation button to start up, it shows ON, press confirm button to enter. Setting of hours, minutes in turn. Timing is the countdown, maximum is 99 minutes and 59 seconds.
  3. Timed shutdown setting: Closed by default, it shows OFF. Press up-regulation button to start up, it shows ON, press confirm button to enter. Setting of hours, minutes in turn. Timing is the countdown, maximum is 99 minutes and 59 seconds.
  4. Setting of pump oil amount: Press up-regulation button or down-regulation button to modify minimum pump oil amount, after it reaches the required number, press confirm button to enter maximum oil mass setting. Press up-regulation button or down-regulation button to modify the maximum pump oil amount, after it reaches the required number, press confirm button to enter the next item.
  5. Fan speed setting: Press up-regulation button or down-regulation button to modify minimum fan speed, after it reaches the required number, press confirm button to enter maximum speed setting. Press the up-regulation button or down-regulation button to modify the maximum fan speed to reach the required value, and then press confirm button to enter the next item.
  6. Operating voltage setting: Main board operating voltage can only be selected under the shutdown state. Press up-regulation button or down-regulation button to switch the setting of the operating voltage, adjust the 12V system to U-12 or 24V system to U-24 to complete the selection. Before start-up, check whether the oil pump, motor and ignition plug of the machine are matched, thus avoiding damage.
  7. Selection of speed signal: When it displays S, press up-regulation button or down-regulation button to set the speed signal. Select 1 if the vane wheel has two magnets with the same polarity. Select 2 (default value) if the vane wheel has different polarity of the magnets or only one magnet. This parameter is incorrectly selected, which will lead to the speed difference of 1 time.
  8. Selection of ignition plug power: When it displays P, press up-regulation button or down-regulation button to modify the numbers (135W, 240W, 345W, 480W, 5=85W, 6=90W), and default value is 5. It is recommended to adopt default values, or make modification after verification.
  9. Administrative password modification: It initially displays OFF, press confirm button to skip the password modification and save above modified parameters. Press the up-regulation button when modifying, then press confirm button to enter password modification state when it displays ON. Press up-regulation button or down-regulation button to adjust. And after entering the 4-digit password correctly, press the confirm button to enter the next digit, then save the new password and adjust the settings parameters to exit automatically.

Precautions: For clock time, set the timing of start-up and shutdown, and it will take effect immediately after setting. After setting all parameters after the administrator's password, you must press confirm button until to the item 9 to exit, through which we could save the set parameters. If quitting in the midway, previous adjustment data will be lost and invalid. Please check each new digit of password carefully and save it, through which you can enter to the parameter modification next time.

Instructions for Use of 12V-24V General LCD Panel

Diagram of the LCD panel showing current status: 35°C, 4500 RPM. Buttons are labeled: Up Arrow, Down Arrow, ON/OFF, Set, Confirm.

1. Button function

2. Query machine status (keep short press of the Confirm button to switch one state at a time to make it display cyclically)

3. Description of fuel filling in manual mode

Under the shutdown state, press the down-regulation button and setting button simultaneously to conduct fuel filling manually, which displays ⛽, and after releasing, press up-regulation button and it displays ⛽, the oil pump starts to work. You can hear the sound of the oil pump working and the oil pump icon lights up. Press down-regulation button to display ⛽, exit fuel filling, the oil pump icon disappears. The process of line air evacuation shall be done under watch, when the oil reaches the position of the oil inlet of the machine, it can be stopped. If there is too much oil enters the machine, there will be black smoke when igniting.

4. Description of temperature control mode switching

Press the up-regulation button and confirm button simultaneously to conduct temperature control mode switch. There are manual temperature control mode (oil mass adjustment ?️ shows, number represents the oil mass) and automatic temperature control mode (temperature adjustment ?️ shows, number represents the temperature). The difference between two modes is that: in automatic mode, pump oil amount can reach the maximum upon parameter setting and the machine heat is higher, the manual pump oil amount is limited to the current setting value and will not reach the maximum oil value set by the parameter, which makes gears clearly shown and is very convenient for the part old hands.

5. Description of remote control code matching

In the shutdown state, press power button and confirm button simultaneously in the remote control first, then text of waiting for matching appears on the remote control, then keep long press up-regulation and down-regulation buttons of LCD panel. When showing HFR it enters the remote control code matching interface, upon success, it will automatically exit the interface, then, it shows normal working parameter. If the code matching failed, it would not enter the normal state of displaying working parameters. The code matching state will be automatically exited when it does not receive remote control code over time.

6. Description of parameter setting procedure (press setting button to enter setting state)

  1. Time setting: Press the up-regulation button or down-regulation button to adjust parameters setting parameters of hour (24-hour system) and minute successively, and press confirm button to confirm the parameters to enter the next item.
  2. Timed start-up setting: Closed by default, it shows OFF. Press up-regulation button to start up, it shows ON, press confirm button to enter. Setting of hours, minutes in turn. Timing is the countdown, maximum is 99 minutes and 59 seconds.
  3. Timed shutdown setting: Closed by default, it shows OFF. Press up-regulation button to start up, it shows ON, press confirm button to enter. Setting of hours, minutes in turn. Timing is the countdown, maximum is 99 minutes and 59 seconds.
  4. Setting of pump oil amount: Press up-regulation button or down-regulation button to modify minimum pump oil amount, after it reaches the required number, press confirm button to enter maximum oil mass setting. Press up-regulation button or down-regulation button to modify the maximum pump oil amount, after it reaches the required number, press confirm button to enter the next item.
  5. Fan speed setting: Press up-regulation button or down-regulation button to modify minimum fan speed, after it reaches the required number, press confirm button to enter maximum speed setting. Press the up-regulation button or down-regulation button to modify the maximum fan speed to reach the required value, and then press confirm button to enter the next item.
  6. Operating voltage setting: Main board operating voltage can only be selected under the shutdown state. Press up-regulation button or down-regulation button to switch the setting of the operating voltage, adjust the 12V system to U-12 or 24V system to U-24 to complete the selection. Before start-up, check whether the oil pump, motor and ignition plug of the machine are matched, thus avoiding damage.
  7. Selection of speed signal: When it displays S, press up-regulation button or down-regulation button to set the speed signal. Select 1 if the vane wheel has two magnets with the same polarity. Select 2 (default value) if the vane wheel has different polarity of the magnets or only one magnet. This parameter is incorrectly selected, which will lead to the speed difference of 1 time.
  8. Selection of ignition plug power: When it displays P, press up-regulation button or down-regulation button to modify the numbers (135W, 240W, 345W, 480W, 5=85W, 6=90W), and default value is 5. It is recommended to adopt default values, or make modification after verification.
  9. Administrative password modification: It initially displays OFF, press confirm button to skip the password modification and save above modified parameters. Press the up-regulation button when modifying, then press confirm button to enter password modification state when it displays ON. Press up-regulation button or down-regulation button to adjust. And after entering the 4-digit password correctly, press the confirm button to enter the next digit, then save the new password and adjust the settings parameters to exit automatically.

Precautions: For clock time, set the timing of start-up and shutdown, and it will take effect immediately after setting. After setting all parameters after the administrator's password, you must press confirm button until to the item 9 to exit, through which we could save the set parameters. If quitting in the midway, previous adjustment data will be lost and invalid. Please check each new digit of password carefully and save it, through which you can enter to the parameter modification next time.

2018 Main Board Fault Code Description

Machine fault LCD panel display Digital panel display Knob panel display Handling method
Power supply under voltage E-01 1 indicator light flash. Boost supply voltage
Power supply with over pressure ⚡⚡ E-02 2 indicator lights flash. Reduce supply voltage
Ignition plug fault ⚡⚡⚡ E-03 3 indicator lights flash. Check whether the ignition plug is in open circuit or short circuit.
Oil pump fault ⚡⚡⚡⚡ E-04 4 indicator lights flash. Check whether the oil pump is disconnected or short circuit.
The machine is overheating ⚡⚡⚡⚡⚡ E-05 5 indicator lights flash. Check the temperature sensor on the shell or whether the fan has the abnormal rotation speed.
Motor fault ⚡⚡⚡⚡⚡⚡ E-06 6 indicator lights flash. Check the magnet polarity, the Hall sensor location or the looseness conditions of wiring terminal.
Broken connection fault ⚡⚡⚡⚡⚡⚡⚡ E-07 7 indicator lights flash. Check the connecting plug of the panel, and whether the blue harness connection has become loose or disconnected.
The flame is extinguished. ⚡⚡⚡⚡⚡⚡⚡⚡ E-08 8 indicator lights flash. Check whether the oil circuit has air or blockage, check whether there is fault on temperature sensor on the shell or whether the connector terminal has become loose.
Sensor fault ⚡⚡⚡⚡⚡⚡⚡⚡⚡ E-09 9 indicator lights flash. Check whether the sensor plug is loose, broken, or in short circuit.
Failure in ignition ⚡⚡⚡⚡⚡⚡⚡⚡⚡⚡ E-10 10 indicator lights flash. Check whether the oil circuit is blocked, or the oil transportation is not smooth, the oil pump is stuck, the volatilization net is blocked due to the oil product problem, and other reasons that cause that 2 ignition fails to burn normally.

The LCD panel fault display is that graphics and numbers are displayed at the same time, the numeral number is same as the digital panel class content.

Bi-directional Remote Control Operation Instructions

1. Operation instruction of buttons

2. Remote control pairing operation

In the shutdown state, first long press down-regulation button on the LCD panel that needs to be paired first. Showing HFR means it enters the remote control code matching interface. Then press the power button and confirm button on the remote control at the same time, the text of waiting matching remote control appears on the remote control, the remote control and switch enter the automatic matching process, and after successful code matching, it will automatically exit the code interface and displays the normal working parameters. If the code matching failed, it would not enter the normal state of displaying working parameters. The code matching state will be automatically exited when it does not receive remote control code over time.

3. Temperature control mode switching

When the temperature control mode is selected by remote control, only press the up-regulation button and down-regulation button at the same time to display the temperature when switching to automatic temperature control, and it will display the oil mass if the temperature is controlled manually.

4. Working status adjustment

The working status of the heater can be adjusted at any time by remote control. The methods are as follows:

Instructions for use of bi-directional remote control receiving

Introduction of buttons:

Lighting instructions

There is the light under the switch button, long lighting indicates the start-up and flashing indicates that there is a fault.

Introduction of button functions

Fuel filling in manual mode

In shutdown state, start the manual oil pumping by pressing On/off button 5 times continuously and quickly. Please press the On/Off button gently to stop the oil pumping when the air has been removed from the oil circuit. This process requires observation of specially-assigned person to avoid excessive fuel entering the machine and black smoke at start-up.

Remote control pairing

In the start-up state, press On/Off button 5 times continuously and quickly, the indicator light flashing means it has entered the remote control pairing waiting state. At the same time, press the power button (setting button) on the remote control for a long time to start the remote control pairing. Wait for auto-completion of pairing to exit.

Fault state description

Machine fault State display Handling method
Power supply under voltage The indicator light flashes 1 time. Boost supply voltage
Power supply with over pressure The indicator light flashes 2 times. Reduce supply voltage
Ignition plug fault The Indicator light flashes 3 times. Check whether the ignition plug is in open circuit or short circuit.
Oil pump fault The indicator light flashes 4 times. Check whether the oil pump has suffered from broken line or short circuit.
The machine is overheating The indicator light flashes 5 times. Check the temperature sensor on the shell or whether the fan has the abnormal rotation speed.
Motor fault The indicator light flashes 6 times. Check the magnet polarity, the Hall sensor location or the looseness conditions of wiring terminal.
Broken connection fault The indicator light flashes 7 times. Check the connecting plug of the panel, and whether the blue harness connection has become loose or disconnected.
The flame is extinguished. The indicator light flashes 8 times. Check whether the oil circuit has air or blockage, check whether there is fault on temperature sensor on the shell or whether the connector terminal has become loose.
Sensor fault The indicator light flashes 9 times. Check whether the sensor plug is loose, broken, or in short circuit.
Failure in ignition The indicator light flashes 10 times. Check whether the oil circuit is blocked, or the oil transportation is not smooth, the oil pump is stuck, the volatilization net is blocked due to the oil product problem, and other reasons that cause that 2 ignition fails to burn normally.

Operation instructions for parking heater

The control panel is shown below

Diagram of the parking heater control panel. It features a digital display showing temperature and mode, and several buttons: 1. Overshift key, 2. On/off key, 3. Downshift key, 4. Setting key, 5. Deterministic key, 6. Work status symbol, 7. Display ambient temperature, 8. Timing symbol, 9. Plateau symbol, 10. Fault symbol, 11. Display data parameters, 12. Host schematic.

Use operation

1. Switching operation

2. Manual oiling operation

In shutdown state, two seconds after pressing the ⬆️ and ⬇️ at the same time, manual control of pumping, stop oiling after releasing the key. Please use cautiously!

3. Plateau model operation

At the same time, press the button for 2 seconds to enter the plateau mode. ⬆️ display start plateau mode, press the "*" and "OK" key for two seconds to exit the plateau mode at the same time. Please use cautiously!

4. Setting timing switch time operation

Two seconds after pressing the "OK" and ⬆️ key at the same time, enter the timing setup time interface, the following figure is shown. Tab ON flicker, display shows 10.1 hours on time. If it display OFF, it means setting a timed shutdown time.

Diagram showing timing setup interface. Shows ON/OFF status, time values (e.g., 10.1 h), and buttons.

  1. Press ⬆️ or ⬇️ key to adjust time value, time range: 1-24 hours.
  2. Short press "O" key, switch to adjust digital bits.
  3. Short press "O" key, switching the Timed Start-up and Timed Shut-down Time value.
  4. Short press "OK" key, save the settings and exit the interface.
  5. Press "*" key for 2 seconds, do not save the settings, exit this interface.

6) Starting Timing Function

At the same time, long press the "*" and ⬆️ key to start the timing function, start the timing boot in the shutdown state, start the timing shutdown in the boot state, press the OK key short to see the remaining time.

6. Remote control code-matching operation

In shutdown state, simultaneous long press "O" and ⬇️ for two seconds, enter remote control code as follows.

Diagram showing remote control code matching interface with digits 0, C, I.

  1. Press ⬆️ or ⬇️ key to adjust the third digit value for remote control coding, the numerical range is 1-5, corresponding five remote controls.
  2. Choose the Code of Remote Controller, arbitrarily press a key of the remote control, Machine Coding Successfully and Exit Coding State.
  3. Short press "*" key to exit remote control code.

*Remote Control Requirements: 433mhz, 24-bit code. Remote control function is optional function, please specify if you need to place an order.

7. Fault alarm

Show the following figure, corresponding to the failure symbol flicker, and corresponding to the failure device icon flicker, display data as fault code, its meaning please refer to the fault table.

Diagram showing fault symbols and device icons that flicker during a fault.

*Spark plug, oil pump, fan, sensor, power supply and other symbols, flicker indicates that the corresponding device failure.

Fault table

Fault code Cause of failure Solutions
E-2 Power supply voltage range: Normal range: 24V (18-32V), 12V (9-16V). Check whether the battery or generator is normal and whether the fuse is aging.
E-3 Ignition plug failure 1) Check whether the ignition plug connector is loose or the wire is short-circuited to the housing.
2) Detect whether the ignition plug is damaged.
E-4 Oil Pump Failure Check for damage, loosening, oxidation, short circuit and breaking of oil pump connections and connectors.
E-5 High temperature alarm (intake > 50 C ; case > 230 C) 1) Check whether the heating duct is unobstructed.
2) Excessive gap between magnet on wind turbine and Hall sensor on controller.
3) Check whether the temperature sensor is normal.
E-6 Fault of Fan 1) Check whether the impeller is stuck.
2) Check if the connection plug-in is loose.
3) Excessive gap between magnet on wind turbine and Hall sensor on controller.
4) Whether the line is short-circuit or open-circuit; leakage of motor.
E-8 Flameout 1) Check for oil shortage, low temperature solidification of oil, blockage of oil pipeline and blockage of oil pump.
2) Check whether the intake and exhaust ducts are unblocked.
3) Check whether the housing temperature sensor is in full contact with the housing and whether the pressure spring is strong.
Unsuccessful start 1) The shell temperature is too high to blow the cooling shell for 3 minutes after starting.
2) There is a lot of white smoke in the exhaust gas.
2.1) Check that the filter beside the ignition plug is clean and not cleaned or replaced.
2.2) Check whether the fuel injection is effective.
2.3) Check whether the ignition plug is aging.
2.4) Is the clearance of the internal wind turbine too large?
2) A small amount of white smoke or no smoke in the exhaust gas.
E-9 Sensor failure 3.1) Check for oil shortage, frozen or blocked oil pipelines.
3.2) Check whether the pump is jammed or damaged and the pump is powerless to pump.
3.3) Check whether the intake and exhaust passages of combustion are unobstructed.
3.4) Check whether the ignition plug is damaged.
4) The ignition is normal but the failure of ignition is still reported.
Check whether the housing temperature sensor is in full contact with the housing, whether the pressure spring is strong, whether the sensor is normal.
Whether the temperature sensor connectors and connectors are damaged or loosened, whether the sensor is damaged or not.

code of use

  1. It is prohibited to use in high humidity, conductive dust, flammable and explosive gases, dust, materials, corrosive media, strong light, strong magnetic, high voltage and high current equipment nearby.
  2. Voltage range of power supply: DC24V controller is suitable for (18-32) V; DC12V controller is suitable for (9-16) V; different voltage controllers are not universal, and it is forbidden to use beyond the applicable voltage range.
  3. The 5KW controller must be used on the 5KW organism; the 2KW controller must be used on the 2KW organism.
  4. If the controller or external device is damaged, it must be replaced by the prototype device and professionals.
  5. It is forbidden to open the controller shell privately.
  6. Equipment must be installed strictly and must be used under safe conditions.
  7. The company is not responsible for the loss and liability of the controller due to the misconnection short circuit and damage of the external devices and lines.
  8. At the high temperature of the body, the fan can not operate, so it must be cooled quickly for the body to make its temperature. Cooling air is injected from the combustion inlet to make the body temperature less than 100 °C. Prevent high temperature from burning parts or causing fire.

Our company is not responsible for any loss or liability caused by the failure to install and use according to Article 1 to 6.

Models: B08X4PK6FT, B08W4WM5SS, B08RHSJ9P1, KW 2.0 5.0 8.0 Diesel Air Heater 8KW, KW 2.0, KW 5.0, KW 8.0, KW 2.0 Diesel Air Heater 8KW, KW 5.0 Diesel Air Heater 8KW, KW 8.0 Diesel Air Heater 8KW, Diesel Air Heater 8KW, Diesel Air Heater, Air Heater 8KW, Air Heater, Heater

PDF preview unavailable. Download the PDF instead.

B1M0 UGftiL GPL Ghostscript 9.52

Related Documents

Preview VEVOR Air Heater KW 2.0/5.0/8.0 Manual - Installation, Operation, and Maintenance Guide
Comprehensive manual for VEVOR Air Heater models KW 2.0, 5.0, and 8.0 (XL-AIRD3, XL-AIRD5). Covers installation, operation, technical specifications, troubleshooting, and maintenance for 12V and 24V systems.
Preview VEVOR Diesel Air Heater Manual: XMZ-D1 & XMZ-D2 Operation and Installation Guide
Comprehensive guide for VEVOR diesel air heaters (models XMZ-D1, XMZ-D2), covering installation, operation, safety precautions, troubleshooting, and Bluetooth connectivity. Learn how to install, use, and maintain your VEVOR diesel heater for optimal performance.
Preview VEVOR Diesel Heater Manual: Models XMZ-D1 & XMZ-D2 - Operation, Installation, and Safety
Comprehensive instruction manual for VEVOR Diesel Heaters (Models XMZ-D1, XMZ-D2). Covers product functions, safety guidelines, installation procedures, internal structure, model comparison, packing lists, remote and Bluetooth operation, troubleshooting, and contact information.
Preview VEVOR Diesel Heater (XMZ-D1, XMZ-D2) User Manual and Installation Guide
Comprehensive user manual and installation guide for VEVOR Diesel Heaters, models XMZ-D1 and XMZ-D2. Covers safety instructions, product functions, internal structure, installation positions, model specifications, packing list, operation, troubleshooting, and Bluetooth connectivity.
Preview VEVOR Diesel Heater User Manual & Installation Guide
Comprehensive user manual for VEVOR Diesel Heaters, including models XMZ-L-D1, XMZ-W-D1, and XMZ-F-D1. Covers safety, installation, operation, troubleshooting, and maintenance.
Preview VEVOR Diesel Heater CY-5002 & CY-5004: User Manual, Safety, and Operation Guide
Comprehensive user manual and safety guide for VEVOR Diesel Heaters, models CY-5002 and CY-5004. Covers installation, operation, troubleshooting, technical specifications, and Bluetooth control.
Preview VEVOR Diesel Heater Manual - XMZ-L-D4, XMZ-W-D4 Installation and Operation Guide
Comprehensive guide for VEVOR Diesel Heaters (Models XMZ-L-D4, XMZ-W-D4), covering safety instructions, product functions, installation, power supply, remote control operation, and troubleshooting.
Preview VEVOR Diesel Heater: User Manual and Operation Guide
Comprehensive user manual for VEVOR Diesel Heaters, including models XMZ-TB20 Pro, XMZ-TB40, XMZ-TB30, and XMZ-HTB1. Learn about installation, operation, safety, and troubleshooting.