Installation Guide for traxon models including: ProPoint Vista 100W, Super High Brightness Luminaire, ProPoint Vista 100W Super High Brightness Luminaire, Brightness Luminaire, Luminaire
ProPoint Vista 100W INSTALLATION GUIDE V1.0 Cover: ProPoint Vista 1x100W RGBW ProPoint Vista 2x100W RGBW ProPoint Vista 3x100W RGBW ProPoint Vista 1x100W White
File Info : application/pdf, 30 Pages, 3.40MB
DocumentDocumentProPoint Vista 100W INSTALLATION GUIDE V1.0 Cover: ProPoint Vista 1x100W RGBW ProPoint Vista 2x100W RGBW ProPoint Vista 3x100W RGBW ProPoint Vista 1x100W White ProPoint Vista 2x100W White ProPoint Vista 3x100W White CONTENT 1. INTRODUCTION 4 2. INSTALLATION 12 3. POWER AND DATA WIRING 21 4. CONFIGURATION 26 5. TROUBLESHOOTING 28 6. WARRANTY INFORMATION 28 7. APPENDIX 29 www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 2 of 30 SAFETY AND OPERATION This installation guide uses the following special statement categories to alert you to key items: 1. WARNING - Indicates a hazardous situation that, if not avoided, could result in death or serious injury. 2. CAUTION - Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury. 3. NOTICE - Indicates information considered important for the proper operation of the product but not hazard related. 4. Please review this manual completely prior to beginning the installation process and take note of the following: · The ProPoint luminaire and associated accessories must be installed by a qualified person in conjunction with all applicable electrical codes and standards. · The ProPoint luminaire does not contain any user-serviceable parts. Opening of the luminaire will void the warranty. · Do not use the product if the cables are damaged. · Handle the luminaire carefully to prevent damage during installation. Rough handling may damage the internal electronics and void the warranty. · Do not attempt installation in wet or severe weather conditions. · Do not stare directly into the light beam while the unit is illuminated. · IP66 rated. The ProPoint luminaire is not suitable for direct immersion in water. · Do not operate the ProPoint luminaire without a connection to earth surface without a suitable earth connection (refer to local standards). · The ProPoint luminaire is designed for operation at 120-277V AC (ETL)/220-240V AC (CE). Voltages outside of this range may damage the fixture and will void the warranty. · The ProPoint luminaire housing may become hot during normal operation and present a risk of burn injury and fire hazard. Exercise caution when working in proximity to the luminaire and make sure that combustible material does not contact the housing or lens. · Failure to keep the luminaire within the operating temperature range (-30°C to +55°C/-22°F to +131°F) will result in improper operation and will void the product warranty. · Do not use harsh chemicals, cleaning solvents or strong detergents when cleaning the luminaire. · Persons installing this product should make sure: i. The installation complies with all applicable codes, state and local laws, ordinances, standards and safety regulations. ii. The installation environment is carefully studied and suitable surge protection measure(s) is taken. Suggested surge protection measures for outdoor application should reach "Live to Neutral" 5kV, "Live/Neutral to Earth" 10kV. iii. All luminaires can pass surge test up to "Live to Neutral" 1kV, "Live/Neutral to Earth" 2kV according to EN61547 standard. iv. They are qualified or competent in the handling of electrical equipment. www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 3 of 30 1. INTRODUCTION 1.1 Product Overview The ProPoint Vista is an AC line powered, high brightness luminaire. Controllable with DMX512, the ProPoint Vista 100W is a new member of the Vista family, along with the 2x100W and 3x100W, The daisy chain topology, and direct-wire nature of the fixture via the two integral cable whips allow for simple installation into existing installations and new structures, and is ideal for high-rise and tower illumination. This manual is intended for use with DMX/RDM versions of the ProPoint Vista 100W. 1.2 Getting Assistance Additional product information is available on the Traxon web site: · www.traxontechnologies.com & www.osram.us/traxon For additional support, please contact Traxon Technical Support: For Americas Regional Support: · +1 (978) 570-3189 Business Hours Technical Support · +1 (978) 267-5346 After Hours Technical Support · TRXTechSupport2@osram.com For Asia Pacific Regional Support · info@traxontechnologies.com For Europe, Middle East and Africa Regional Support · info@ecue.com · support@ecue.com www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 4 of 30 1.3 Dimensions FIG.1: ProPoint Vista 1x100W 649mm (25.6") 200mm (7.9") 261mm (10.3") 4-4Ø-1(Ø30m.5m") 200mm 286.8mm (7.9") (11.3") (Ø1Ø.217")mm 636mm (25.0") 300mm (11.8") 100mm (3.9") 636mm (25.0") 261mm (10.3") ProPoint Vista 100W open wire cable lengths Power input cable Cable Length (open wire) Cable Outer Diameter 1830mm (72") 7.8mm (0.31") Data in/out cable (combined) 1830mm (72") 8.1mm (0.32") 144mm (5.7") 187mm (7.4") www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 5 of 30 FIG.2: ProPoint Vista 2x100W 674mm (26.5") 662mm (26.1") 300mm (11.8") 100mm (3.9") 4-Ø13mm Ø27mm 4-(Ø0.5") (Ø1.1") 686mm (27") 215mm (8.5") 4(1883.m9"m) 4(1360.m9"m) 30mm (1.2") 662mm (26.1") 144.2mm (5.7") 342mm (13.5") +90° 230mm 428.6mm (9.1") (16.9") 268mm (10.6") 341.6mm (13.4") 483mm (19") 268mm (10.6") ProPoint Vista 100Wx2 open wire cable lengths Power input cable Cable Length (open wire) 1830mm (72") Cable Outer Diameter 7.8mm (0.31") Data in/out cable (combined) 1830mm (72") 8.1mm (0.32") -30° -30° -30° +30° +90° www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 6 of 30 FIG.3: ProPoint Vista 3x100W 144mm (5.7") 149mm (5.9") 144mm (5.7") 453mm (17.8") 686mm (27") 662mm (26.1") 300mm (11.8") 100mm (3.9") 4-Ø13mm Ø27mm (Ø0.5") (Ø1.1") 200mm (7.9") 430mm (1.6") 710mm (28") 660mm (26") 30mm (1.2") 694mm (27.3") 674mm (26.5") 649mm (25.6") 460mm (18.1") 230mm (9.1") 710mm (28") 380mm (15") 380mm (15") 453mm (17.8") ProPoint Vista 100Wx3 open wire cable lengths Cable Length (open wire) Cable Outer Diameter Power input cable 1830mm (72") 7.8mm (0.31") Data in/out cable (combined) 1830mm (72") 8.1mm (0.32") -30° -20° -20° -30° 0° +90° -30° +20° -20° +30° 662mm (26.1") Additional Accessories (Optional accessory for 2x100W and 3x100W units) A additional accessories kit may be ordered for the 2x100W and 3x100W luminaire models. This kit allows for mounting directly into a suitable angle. The kit can be installed onto the luminaires directly. Additional accessories include a Rock Guard to protect the lens, and an Angled Glare shield and Open Glare shield to help hide the light source. www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 7 of 30 FIG.4: ProPoint Vista 100W Accessories-Full/Half Glare Shield Full Glare Shield 5.2mm/0.2" 626mm/24.65" 130mm/5.11" 130mm/5.11" 130mm/5.11" 130mm/5.11" 148mm/5.83" 191mm/7.52" 170mm/6.69" Half Glare Shield 5.2mm/0.2" 626mm/24.65" 130mm/5.11" 130mm/5.11" 130mm/5.11" 130mm/5.11" 172mm/6.77" 35° 191mm/7.52" 170mm/6.69" www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 8 of 30 FIG.5: ProPoint Vista 100W Accessories-Pole Mounting Supporter/Rock Guard Pole Mounting Supporter 800mm/31.5" 500mm/19.69" 300mm/11.81" 126mm/4.96" 13.3mm/0.52" 25mm/0.98"Ø30mm/1.18" 150mm/5.91" Ø116mm/4.57" 4-M8 158mm/6.22" 8mm/0.31" 90mm/3.54" 30mm/1.18" Rock Gard 620mm/24.41" 30mm/1.18" 179.7mm/7.07" www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 9 of 30 1.4 Packing Contents FIG.6: Packing Contents 1 x ProPoint Vista 100W (size/model based on order) 1.5 Component Overview Luminaire Options The ProPoint Vista 100W luminaire is available in the following sizes: Model 1x100W 2x100W 3x100W Weight Power Consumption Power (Nominal) Factor 14.5kg / 31.96lbs. 100W 28.3 kg / 63 lbs. 200W 0.9 44 kg / 97 lbs. 300W Input Voltage Operating Range Temperature 120-277VAC -30°C to +55°C 50/60 Hz (-22°F to +131°F) Minimum Starting Temperature -20°C (-4°F) The ProPoint Vista 100W luminaire is available with the following optical engines: Model Color Option 1x100W Color Changing (RGBW) White 2x100W Color Changing (RGBW) White 3x100W Color Changing (RGBW) White Lens Options 3° native; 5°, 8°, 10°, 15°, 20°, 30°, 40°, 55°, 80°, 50°x10°, 50°x5° via accessory Internal Louver (Standard) DMX Control Channels 4 1 4 1 4 1 Color Temperature RGBW (White CCT: 4000K standard) Other White CCT and RGBA available 3000K / 4000K 2700K, 3500K, 5000K, 6500K, Red, Green, Blue, Amber available RGBW (White CCT: 4000K standard) Other White CCT and RGBA available 3000K / 4000K 2700K, 3500K, 5000K, 6500K, Red, Green, Blue, Amber available RGBW (White CCT: 4000K standard) Other White CCT and RGBA available 3000K / 4000K 2700K, 3500K, 5000K, 6500K, Red, Green, Blue, Amber available The in-rush current data of ProPoint Vista 100W is shown in the following tables: www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 10 of 30 Description ProPoint Vista 100W ProPoint Vista 2x100W (200W) ProPoint Vista 3x100W (300W) 1 Fixture 30A 60A 90A Description Description ProPoint Vista 100W ProPoint Vista 2x100W (200W) ProPoint Vista 3x100W (300W) 1 Fixture 60A 120A 180A In-rush current @ 120V 2 Fixtures 3 Fixtures ... 60A 90A ... 120A 180A ... 180A 270A ... In-rush current @ 230V 2 Fixtures 3 Fixtures ... 120A 180A ... 240A 360A ... 360A 540A ... n Fixtures n*30A n*60A n*90A Present time 0.38ms 0.38ms 0.38ms n Fixtures n*60A n*120A n*180A Present time 0.38ms 0.38ms 0.38ms 1.6 Additional Accessories Termination Kit A ProPoint termination kit (part number AM243520054) may be purchased separately. This kit contains the following components: - (6) Splicing wire connectors: For use in connecting data cable conductors. See section 3.2 for additional information on usage. NOTE Wire nuts are not permissible for use with data connections and will void warranty. - 120 Ohm resistor for use in terminating the DMX512 data line at the last luminaire. See section 2.6 for additional information on usage. FIG.7: ProPoint Termination Kit www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 11 of 30 2. INSTALLATION Each ProPoint Vista 100W luminaire is shipped with a mounting bracket suitable for Surface/Pole mount applications. This mounting plate is pre-installed at the mounting interface of the luminaire. 2.1 Surface Mount Installation Required Tools 2x100W Model 3x100W Model 14mm and 17mm Hex Key 14mm and 17mm Hex Key Surface Mount Installation FIG.8: ProPoint Vista 100W Surface Mount Installation Preparation · Remove the ProPoint Vista 100W luminaire from the packaging and place the unit on a level surface. Bracket Preparation and Mounting CAUTION It is the installer's responsibility to ensure that the mounting surface can handle the static weight of the fixture as well as dynamic loading from environmental factors such as wind and snow/ice buildup. The use of Grade 5 or higher hardware is recommended. · Make sure that the bolts on the mounting surface align with the holes on the surface mount bracket · Install the luminaire to the mounting surface and secure using appropriate hardware (by others). NOTICE The ProPoint Luminaire should be installed with the power and data cables exiting the housing directly down when the luminaire is mounted on a vertical surface. For applications that require horizontal orientation of the power and data cables, the installer shall apply RTV silicone to the cable gland entry points. The luminaire shall not be installed with the power and data cabling oriented up. www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 12 of 30 Surface Mount Installation Steps · After placing the stainless steel mounting bracket on the mounting surface, mark the positions of 4 mounting holes and drill 4 x M12 expanding anchors into the holes with the electric drill. FIG.9: Surface Mounting Step 1 90mm (3.5" (Screws are not included) 662mm (26.1" 500mm (19.7" 300mm (11.8") 100mm (3.9" (1.1" 27mm 4-13mm (0.5" Bracket Installation · Mark the positions of mounting holes and drill M12 expanding anchors into the holes with the electric drill. Fix the M12*50 hex bolt/12 flat washer/12 Spring washer as the following picture shows to install the bracket. NOTICE It is the responsibility of the installer to ensure that the mechanical fixings are appropriate for the task and if necessary, approved by a structural engineer as the installation scenario is unique for each luminaire FIG.10: Bracket Mounting · After aligning 4 13mm holes and expansion screws on the floor of the stainless steel mounting bracket, lock the mounting bracket. www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 13 of 30 FIG.11: Surface Mounting Step 2 · Loosen the adjusting bolts with 17mm Hex Key, adjust the overall angle of the luminaire and tighten the adjusting bolts. · Loosen the adjusting bolts with 14mm Hex Key, adjust the single-head exposure angle and tighten the adjusting bolts. CAUTION Do not rotate the luminaire more than 180 degrees. Rotating more than 180 degrees may cause the power and/or data cables to bind inside the unit resulting in damage. FIG.12: Surface Mounting Step 3 11mm hex key can adjust the mounting bracket screw, can be used to adjust the single moudle angle of the whole luminaire. 11mm hex key can adjust the mounting bracket screw, can be used to adjust the angle of the whole luminaire. www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 14 of 30 2.2 Pole Mount Installation (Vertical Mounting only) Required Tools 2x100W Model 3x100W Model 14mm and 17mm Hex Key 14mm and 17mm Hex Key Pole Mount Installation FIG.13: ProPoint Vista 100W pole Mount Installation Preparation · Remove the ProPoint luminaire from the packaging and place the unit on a level surface. Pole Mounting Steps · Mark the positions of the 4 mounting holes and then drill 4 x M12 holes with an electric drill. Mount the luminaire bracket to the post mount plate using suitable M12 fixings (e.g. M12 bolt, spring washer and locking M12 nut). www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 15 of 30 FIG.14: Pole Mounting Step 1 102 16 · Fix the inner hexagon screw to fasten the pole mounting supporter onto the pole. FIG.15: Pole Mounting Step 2 4-M8*10 hex socket screw 4 mm hex key to fasten screws (Screws and pole are not included) www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 16 of 30 · Pull the power and data cabling through the pole fitting (by others). Install the luminaire onto the pole fitting and secure mounting screws and lock nuts. FIG.16: Pole Mounting Step 3 M12*50 hex bolt / 12 flat washer /12 Spring washer M12 Nut Put the connected signal cable/power cable into the pole (Screws and pole are not included) · Fix the luminaire and use a suitable inner Hex Key to adjust the luminaire to a target angle. FIG.17: Pole Mounting Step 4 14 mm hex key to adjust the angle of single module 17 mm hex key to adjust the angle of whole luminaire www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 17 of 30 Recording the UID (DMX/RDM Model Only) Each ProPoint Vista 100W luminaire is marked with a Unique Identifier (UID) on the product label. This UID is used to address the luminaire for correct operation. Example: 16DC:0834AA0B AA0B represents the designation shown on the label. Before completing installation, record each luminaire's UID in a manner similar to the table included at the end of this manual. FIG.18: UID Location Record the UID code and physical location from the label located on the side of each luminaire. UID: *0834 2.3 Power Wiring The ProPoint Vista 100W luminaire is supplied with a 1.8 meter (6 foot) long power feed cable. This cable may be field-cut to the required length by the installer. WARNING Risk of electrical shock. Make sure that the branch circuit is disconnected prior to installation or inspection.. CAUTION CAUTION Make sure that the cable is protected from cuts and abrasions that may result in damage to the outer jacket. IP failure induced by stressed/damaged cable entry points during or after installation will void the product warranty. NOTICE NOTICE A voltage divider is recommended (and may be required by local electrical code) when a single junction box is utilized for termination of the power supply and data cables. Cable bend radius must NOT be less than the Minimum Bending Radius (4 X Cable Diameter) as specified by cable manufacturer and the Non-Bendable Length of 5cm (2in) near the cable gland MUST be adhered to. In addition to the Minimum Bending Radius, ensure that 5cm (2in) of cable at the connector junction is kept straight. www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 18 of 30 2.4 Glare Shield Installation (Optional Accessory) Required Tools 2x100W Model 3x100W Model 5mm and 3mm Hex Keys 6mm and 4mm Hex Keys Preparation · Remove the ProPoint luminaire from the packaging and place the unit on a level surface. FIG.19: Accessories Structure Accessories Installation · Fix the screws as the following picture shows to install the additional accessories as your requirements. FIG.20: Accessories Mounting Spread Lens Frame Mounting Angled Glare Shield Mounting Rock Guard Mounting Open Glare Shield Mounting CAUTION Ensure that the mounting surface and hardware are suitable for the luminaire weight. www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 19 of 30 Final Installation NOTE For ease of installation and Safety, the following step may require 2 people to perform. This is largely dependent on the location/orientation of the junction box and the size of the fixture being mounted. All installers should refer to their occupational safety and best practice guidelines when performing these tasks. · Install the luminaire onto the mounting bracket and secure the set screws and lock nuts. CAUTION Ensure that the power and data cabling is routed so that the luminaire mounting interface does not crush the power and/or data cable jacketing. · Tighten both set screws so that each screw engages securely in the surface mount bracket groove. CAUTION Both set screws must engage within the groove. Failure of the set screws to engage the groove could result in the luminaire separating from the surface mount bracket. · Tighten both lock nuts over the set screws. Grasp the luminaire body and rotate it back and forth on the mounting bracket to ensure that the fixture is securely fastened. CAUTION Do not rotate the luminaire more than 180 degrees. Rotating more than 180 degrees may cause the power and/or data cables to bind inside the unit resulting in damage. www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 20 of 30 3. POWER AND DATA WIRING 3.1 Data Wiring The ProPoint Vista 100W luminaire is supplied with a 1.8 meter (6 foot) long data cable. This cable may be fieldcut to the required length by the installer. The ProPoint Vista 100W luminaire utilizes a "daisy chain" wiring topology for DMX data communication. Data connections are made via the DMX input and output wiring pairs in the data cable. Utilization of a "star" wiring topology (via t-taps, y-cables, etc.) is not permitted. Installed data cabling shall conform to the requirements outlined in ANSI E1.11 Entertainment Technology USITT DMX512-A, Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. All cabling shall utilize stranded conductors. Solid core conductors shall not be used and can result in denial of warranty. A maximum of 32 ProPoint luminaires may be connected to a DMX data line. The maximum overall data line length (from DMX controller to the last unit in the daisy chain) is 300m (984ft). WARNING Risk of electrical shock. Ensure that branch circuit power is disconnected prior to performing installation or inspection of data wiring. CAUTION Make sure that the cable is protected from cuts and abrasions that may result in damage to the outer jacket. CAUTION IP failure induced by stressed/damaged cable entry points during or after installation will void the product warranty. NOTICE A voltage divider is recommended and may be required by local electrical code) when a single junction box is utilized for both power supply and data cable termination. NOTICE Cable bend radius must NOT be less than the Minimum Bending Radius (4 x Cable Diameter) as specified by cable manufacturer and the Non-Bendable Length of 5cm (2in) near the cable gland MUST be adhered to. In addition to the Minimum Bending Radius, ensure that 5cm (2in) of cable at the connector junction is kept straight Installation Steps 1. Determine the required length of data cable. Make sure to account for cable management (routing, drip loops, etc.) prior to removal of unneeded cable. 2. Make sure that there is sufficient cable to account for thermal expansion and contraction. 3. Insert the data cable into the pole. The cable entry points shall be protected with fittings suitable for maintaining a water-tight installation. NOTICE The use of RTV silicone is required at all terminal box penetration points. 4. Connect the luminaire DMX input and output conductors to the contractor installed DMX wiring. NOTICE All data wire connections shall be made using cage clamp style connectors included in the termination kit (ordered separately). Wire nut connections of the data conductors shall not be used and will void the warranty. www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 21 of 30 5. Install the termination resistor (included in the termination kit) between the Data - and Data + conductors on the last unit in the control. See Figure 23 for specific wire connections. NOTICE Termination is required for proper operation and shall be applied at the last unit of the daisy chain only. Failure to apply termination correctly will void the warranty. FIG.21: DMX Termination Detail To ProPoint luminaire Data pair to luminaire Orange Red Grey Purple DMX- IN DMX+ IN DMX- OUT DMX+ OUT DMX + DMX - Data pair from luminaire WAGO 221-412 Lever Nut (Typical of 6) DMX + DMX - 120 Ohm Terminator NOTE · Maintain data pair wire twist at all connection points. · To prevent short circuits, do not strip more conductor insulation than required for connection. · The use of wire nuts is not acceptable and will void the warranty. · Data termination shall be made in weatherproof enclosure by others. Use suitable cable glands and apply RTV silicone at all entry points. NOTICE Data shall enter each luminaire using the DMX In wire pair (Orange and Red conductors). A 120 Ohm termination resistor shall be installed on the DMX Out wire pair (between Grey and Purple conductors). Failure to terminate at the last luminaire will void the warranty and may result in control issues. FIG.22: DMX Termination Detail www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 22 of 30 FIG.23: 100W Wiring Details www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide -- ProPoint Vista fixtures ship with two -- Each DMX512 link must be -- Data cabling from DMX source to first cable whips: One cable whip for power properly terminated to prevent fixture and between subsequent input, consisting of two wires plus a ground, and one cable whip for signal reflections. ProPoint Vista fixtures shall be Cat5e UTP or higher (stranded type only) or DMX512 RDM input/output. other cable type suitable for DMX -- No more than (32) fixtures on a single DMX512 link, max 300m total (source to last fixture). communication. Consult DMX standard for additional guidance. V1.0 04/21 General Notes -- All data cabling must adhere to ANSI E1.11-2008 (R2013) Entertainment Technology USITT DMX512-A, Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. -- Fixture is RDM compatible. -- Fixtures allow a universal input of 120VAC to 277VAC. -- Data termination shall utilize cage clamp terminal blocks, or equivalent. Wire nuts are not permissible and will void warranty. -- The method of line voltage termination, both for data and power, is at the discretion of the installing contractor, and/or engineer. Splicing and/or joining of cables must adhere to all applicable electrical codes. -- Cables must be spliced/joined in a weatherproof enclosure/junction box, which is to be properly rated and provided by others. P. 23 of 30 FIG.24: 100Wx2 Wiring Details www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide -- ProPoint Vista fixtures ship with two -- Each DMX512 link must be -- Data cabling from DMX source to first cable whips: One cable whip for power properly terminated to prevent fixture and between subsequent input, consisting of two wires plus a ground, and one cable whip for signal reflections. ProPoint Vista fixtures shall be Cat5e UTP or higher (stranded type only) or DMX512 RDM input/output. other cable type suitable for DMX -- No more than (32) fixtures on a single DMX512 link, max 300m total (source to last fixture). communication. Consult DMX standard for additional guidance. V1.0 04/21 General Notes -- All data cabling must adhere to ANSI E1.11-2008 (R2013) Entertainment Technology USITT DMX512-A, Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. -- Fixture is RDM compatible. -- Fixtures allow a universal input of 120VAC to 277VAC. -- Data termination shall utilize cage clamp terminal blocks, or equivalent. Wire nuts are not permissible and will void warranty. -- The method of line voltage termination, both for data and power, is at the discretion of the installing contractor, and/or engineer. Splicing and/or joining of cables must adhere to all applicable electrical codes. -- Cables must be spliced/joined in a weatherproof enclosure/junction box, which is to be properly rated and provided by others. P. 24 of 30 FIG.25: 100Wx3 Wiring Details www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide -- ProPoint Vista fixtures ship with two -- Each DMX512 link must be -- Data cabling from DMX source to first cable whips: One cable whip for power properly terminated to prevent fixture and between subsequent input, consisting of two wires plus a ground, and one cable whip for signal reflections. ProPoint Vista fixtures shall be Cat5e UTP or higher (stranded type only) or DMX512 RDM input/output. other cable type suitable for DMX -- No more than (32) fixtures on a single DMX512 link, max 300m total (source to last fixture). communication. Consult DMX standard for additional guidance. V1.0 04/21 General Notes -- All data cabling must adhere to ANSI E1.11-2008 (R2013) Entertainment Technology USITT DMX512-A, Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories. -- Fixture is RDM compatible. -- Fixtures allow a universal input of 120VAC to 277VAC. -- Data termination shall utilize cage clamp terminal blocks, or equivalent. Wire nuts are not permissible and will void warranty. -- The method of line voltage termination, both for data and power, is at the discretion of the installing contractor, and/or engineer. Splicing and/or joining of cables must adhere to all applicable electrical codes. -- Cables must be spliced/joined in a weatherproof enclosure/junction box, which is to be properly rated and provided by others. P. 25 of 30 4. CONFIGURATION 4.1 Luminaire Addressing and Control The ProPoint Vista 100W 2x100W luminaire utilizes 4 DMX channels for the RGBW unit, and 1 DMX channel for the White units and for the ProPoint Vista 100W 3x100W, utilizes 8 DMX channels for the RGBW unit, and 2 DMX channel for the White units. The ProPoint Vista 100W luminaires are shipped with a default DMX address of 001. For installations where independent control of luminaires is required, the DMX address will need to be modified using a controller that supports Remote Device Management (RDM). · Connect an RDM capable control device to the DMX line ahead of the first luminaire. · Enable RDM discovery per the instructions of the controller manufacturer. · The controller will discover available ProPoint luminaires. These luminaires can be identified by the prefix 16DC in each unit's UID. · Using the RDM identify function, locate a single unit in the installation. The associated luminaire will flash. · Note the physical location of the flashing unit and then disable the identify function. · Determine the desired address for the identified luminaire and enter it in the address field of the RDM controller. · Continue the above process until all units have been addressed. · Record the UID data and associated addresses at the end of this document. · Test each luminaire to verify correct addressing prior to completing installation. ProPoint Power-Up and Loss of Data Behavior The ProPoint Vista 100W luminaire will exhibit the following behavior upon power-up and loss of DMX data: Power-Up with no DMX data present Luminaire will illuminate at full power Power-Up with DMX data present Loss of DMX data Luminaire will respond based on the DMX values being received Luminaire will hold the last valid DMX values received until a power cycle or until DMX is restored. DMX Channel Functions RGBW Unit DMX Channel 1 2 3 4 White Unit Function Red Intensity Green Intensity Blue Intensity White Intensity DMX Channel 1 Function White Intensity Supported RDM Parameters www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 26 of 30 Parameter ID 0x00F0 0x1000 0x0081 0x0082 0x0200 0x0201 Description DMX Start Address Identify Device Manufacturer Label Device Label Sensor Definiton Sensor Value Supported RDM Sensors Sensor Number Sensor Description Default Value 1 0 Traxon Technologies ProPoint xx N/A N/A Note Changing value to 1 will cause fixture to flash Read Only Parameter Read Only Parameter Read Only Parameter Unit of Measure Safe Operating Range #0 Driver Temperature Celsius #1 Drive Voltage DC Volts #2 Driver Current mA #3 On-Line Time ks www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 27 of 30 5. TROUBLESHOOTING Problem Cause Solution Product does NOT light up after installation Incorrect Power Connection · Check Mains Power · Check power supply leads and wire connections · Ensure output wires are connected with proper polarity Shadowing Flickering Light source covered · Check for cables, wires or unwanted debris covering LED light source Incorrect power input/ Excess products connected · Ensure the input voltage is correct · Ensure the power supplies are not overloaded due to an excess of fixtures connected · Ensure that only 32 Devices are connected on single daisy chain, remove any excess devices and power cycle the fixture feed power. Check and see if issue still exists. All fixtures respond the same to data input Improper addressing · Confirm the fixtures in the run do not share the same address(es) · Readdress fixtures 6. WARRANTY INFORMATION Traxon Technologies warrants this product against material and workmanship defects for a period of five (5) years from date of purchase, provided that the purchased items are used under the conditions stated in this user manual. Please refer to www.traxontechnologies.com or www.osram.us/traxon for all warranty terms and conditions. www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 28 of 30 7. APPENDIX UID/Address Recording Table Luminaire UID Unit 1 Unit 2 Unit 3 Unit 4 Unit 5 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 Unit 11 Unit 12 Unit 13 Unit 14 Unit 15 Unit 16 Unit 17 Unit 18 Unit 19 Unit 20 Unit 21 Unit 22 Unit 23 Unit 24 Unit 25 Unit 26 Unit 27 Unit 28 Unit 29 Unit 30 Unit 31 Unit 32 DMX Address DMX Universe # Fixture Mounting Location Note NOTE Do not exceed 32 luminaires on a single DMX data line. Termination resistor must be installed at the last luminaire only. www.traxontechnologies.com | www.osram.us/traxon ©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXONTM, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Installation Guide V1.0 04/21 P. 29 of 30 Please check for the latest updates and changes on the Traxon website. © 2021 TRAXON TECHNOLOGIES ALL RIGHTS RESERVED. Information is subject to change without prior notice. www.traxontechnologies.com | www.osram.us/traxon