480, 482, 680 and 682 Digital Weight Indicators Panel Mount Option

The 480, 482, 680 and 682 Digital Weight Indicators with universal enclosures can be panel mounted with a kit (PN 151099). This document discusses the process of panel mounting the indicators with universal enclosures.

Manuals and additional resources are available from Rice Lake Weighing Systems at www.ricelake.com/manuals. Warranty information can be found on the website at www.ricelake.com/warranties.

WARNING: Disconnect power to indicator before installing in panel mount kit.

NOTE: For more information about 480, 482, 680 and 682 indicators, see:

Parts Breakdown

This section lists parts provided in the panel mount option kit (PN 151099):

Figure 1. Panel Mount Kit: Illustrates the components of the panel mount kit, including a bezel bracket, exterior and interior gaskets, a reinforcement plate, lock nuts, and clamp assemblies.

Item No. Part No. Description Qty
1 158033 Panel Mount Bezel Bracket without gasket 1
2 52946 Gasket, Exterior Panel Mount 1
3 52947 Gasket, Interior Panel Mount 1
4 167433 Reinforcement Plate 1
5 162913 Lock nut, M6 x 1 2
6 166164 Clamp Assembly 2
NS 53412 Cutout Template 1

Bezel Bracket Dimensions

Figure 2. Bezel Bracket Dimension Diagram: Shows the bezel bracket with dimensions labeled A, B, C, and D, indicating the overall width, cutout width, height, and depth.

A B C D
Dimensions 10.50 in (266.70 mm) 9.59 in (243.58 mm) 7.00 in (177.80 mm) 6.09 in (154.68 mm)

Installation

Perform the following to install an indicator in the panel mount kit:

  1. If attached, remove the tilt stand from the indicator enclosure. For more information on tilt stand removal, see the indicator's technical manual.
  2. Place cutout template on required position on panel and carefully trace outside. Ensure cutout will be far enough from panel edge to accommodate bezel dimensions (See Figure 2) and install clamping assembly. Figure 3. Remove Tilt Stand and Trace Cutout Lines depicts this process, showing the tracing of the cutout template on the panel.
  3. Remove reinforcement plate and retain for later. Cutout traced lines on panel to make a 9.8 in W x 6.3 in H (249 mm W x 160 mm H) opening in the panel.

    NOTE: If multiple units are being mounted, ensure the panels are horizontally spaced 14 inches on center.

  4. Peel adhesive backing from the bezel gaskets, then press bezel into the panel cutout.
  5. Place the reinforcing plate over the bracket from the inside of the panel. Figure 4. Insert Bezel Bracket illustrates the bezel bracket inserted into the panel with the reinforcing plate positioned on the interior.
  6. Follow the indicator's technical manual to install cabling and back plate of the indicator.
  7. Insert the indicator into the panel mount bezel from the inside panel. Align the mounting studs to the slot in the bracket.
  8. Place one clamp assembly over the mounting stud.
  9. Install one M6 x 1 lock nut on the mounting stud, tighten only until the locking feature is engaged and the nut does not rotate off the stud. The clamp assembly will be able to rotate on the stud.

    IMPORTANT: Do not over tighten, this contact must slide when the clamp is applied in Step 10.

    Figure 5. Install Indicator shows the alignment of mounting studs and the inner and outer screws of the clamp assembly.
  10. Tighten the inner screws of the clamp assembly (see Figure 5), engaging the clamp bar in the bezel bracket while the indicator presses tight against the inner bezel gasket.
  11. Tighten the outer screws of the clamp assembly until the bezel is held loosely against the panel.
  12. Repeat Steps 8 through 11 for opposite side with remaining clamp and nut.
  13. Tighten inner and outer screws of both clamp assemblies until the front bezel is held securely against the front surface of the panel. Figure 6. Tighten Clamp Assembly visually represents the tightening of the clamp assembly screws.

Indicator Removal

  1. Loosen the outer screws on one clamp assembly to relieve pressure on the center screw.
  2. Loosen the center screw so that the clamp assembly can be pulled out of the way of the back panel of the indicator. There is no need to completely remove the clamp assembly.
  3. Remove the back panel of the indicator and perform the required maintenance as noted by the indicator manual.
  4. Tighten the center screw of the clamp assembly, engaging the clamp bar in the bezel bracket as shown, until the indicator is pressed securely against the inner bezel gasket.
  5. Tighten the outer screws of the clamp assembly until the front bezel is held securely against the front surface of the panel.
Models: 480, 482, 682, Digital Weight Indicators, 480 Digital Weight Indicators, Weight Indicators, Indicators

File Info : application/pdf, 4 Pages, 609.15KB

PDF preview unavailable. Download the PDF instead.

a 158130 pnlmnt 48x 68x enus revd

References

Related Documents

Preview Rice Lake Weight Indicator Guide
A comprehensive guide to Rice Lake Weighing Systems' digital weight indicators and controllers, covering programmable, general purpose, basic weighing, signal conditioning transmitters, specialty, and remote display indicators.
Preview Rice Lake Weight Indicator Guide: Programmable, General Purpose, and Specialty Scales
Explore Rice Lake Weighing Systems' comprehensive range of digital weight indicators, including programmable, general purpose, basic weighing, signal conditioning transmitters, specialty, checkweighing, counting, and large display models. Find detailed features and specifications for each series.
Preview Rice Lake Digital Weight Indicators: A Comparative Feature Matrix
Compare features of Rice Lake's extensive family of digital weight indicators, from basic models to advanced programmable units, including display types, connectivity, I/O, and protocols.
Preview Rice Lake Indicators and Controllers Product Catalog
Explore the comprehensive range of Rice Lake Weighing Systems' indicators and controllers, designed for precision and reliability in various industrial applications. This catalog details models like the 120/120 Plus, IQ Plus 210, CW-90, CW-90X, 380 Synergy Series, 380X Synergy Series, 381 Synergy Series, and 480/482 Legend Series, highlighting their features, specifications, and applications.
Preview Rice Lake Weighing Systems Synergy Series Digital Weight Indicators Comparison
A detailed comparison of Rice Lake Weighing Systems' Synergy Series digital weight indicators, including models 380, 380X, 381, 680HE, 680 Plus, and 682 Plus, covering specifications such as IP rating, display, battery, connectivity, and protocols.
Preview 480/482 Legend Series Concurrent Fast/Slow Setpoint Batching Routine Guide
Guide to configuring and wiring the Rice Lake 480/482 Legend Series Indicator for a concurrent fast/slow setpoint batching routine, including setpoint configuration and wiring details.
Preview 680 Synergy Plus Digital Weight Indicator Technical Manual
Explore the comprehensive technical manual for the Rice Lake Weighing Systems 680 Synergy Plus Digital Weight Indicator. This guide covers installation, operation, configuration, maintenance, and troubleshooting for industrial weighing applications.
Preview Manual Técnico 680 Synergy Plus - Rice Lake Weighing Systems
Manual técnico completo para el indicador digital de pesaje 680 Synergy Plus de Rice Lake Weighing Systems. Cubre instalación, configuración, operación, mantenimiento y solución de problemas.