Model: DMS05

Product Accessories

Reminder: Please check if the accessories are complete upon receipt. If any are missing, contact customer service at support@tacklifetools.com.

Battery Installation

Please refer to the illustration for battery installation, noting the positive [+] and negative [-] poles. After installation, place the auxiliary strap back into the battery compartment and close the battery cover. To remove the battery, gently pull the auxiliary strap.

The device shows a "Boot page" after battery installation. Short press the button to turn on, entering metal detection mode. The detector will display its status on the LCD screen.

Modes of Operation

Metal Detection: Ferrous Metal

The maximum detection depth for ferrous metals is 120mm (approximately 4-3/4 inches). For optimal accuracy, use when the measured object is a standard steel-reinforced copper pipe with a diameter of 18mm. Move the detector at a constant speed of ≤ 6cm/s.

The detector displays a magnetic metal icon when detecting ferrous metals. When an object is detected, a yellow or red indicator light illuminates. The percentage display on the screen gradually increases as the edge of the object is detected, reaching 100% at the center point.

Metal Detection: Non-magnetic Metal

The maximum detection depth for non-magnetic metals (like copper) is 80mm (approximately 3-1/8 inches). When the center is detected, a buzzer will sound. The detection method is the same as for ferrous metals.

The detector displays a non-magnetic metal icon when detecting non-magnetic metals. Similar to ferrous metal detection, indicator lights (yellow or red) illuminate when an object is detected, and the percentage display increases towards the center.

Wood Stud Detection

This mode is suitable for detection on gypsum boards. Detection requires the device to be held lightly close to and always in contact with the wall. Move the detector at a constant speed of ≤ 4cm/s.

To switch between "exact" and "deep" detection modes, long press the Wood Studs Button for 3 seconds. The green light will flash, and a beep will sound.

Interpreting indicators in wood mode:

When an object is detected, the yellow or red indicator lights up. The percentage display gradually increases as the edge of the object is detected, reaching 100% at the center point.

Alternating Current (AC) Detection

When the AC power symbol on the detector flashes, it signifies that AC power is nearby. AC power can be detected simultaneously with other objects (metal or wood), and the AC power symbol will be displayed.

Warning: If the wall contains live wires, exercise extreme caution. Ensure power, gas, and water are turned off before drilling. The red light flashes and emits a rapid tone when AC power is detected.

Live cables can be detected in both metal mode and foreign object mode (if the cable cross-section is ≥4mm²).

Wire Detection

The maximum detection depth for a live cable is 50mm (approximately 2 inches). If the cable is not charged, the detection depth will be reduced.

Conditions that can affect measurement depth include:

Moisture Measurement

Warning: If used incorrectly, the probe tip may cause injury. When the equipment is not in use, always replace the protective cover and keep the tool away from children.

To locate leaks in water pipes within a wall, take measurements at various locations; the leak point is identified where the tool displays the highest reading. The method for building moisture measurement is the same as for wood measurement.

Calibration Note: After a significant change in ambient temperature, wait at least 30 minutes for the measurement to ensure accuracy.

Measurement Process:

  1. Remove the probe cover.
  2. Place the probe on the measurement surface without applying excessive force.

Working Humidity Range:

Conditions to Avoid: Avoid direct sunlight, avoid moisture, avoid wearing jewelry, and avoid placing the device close to home appliances.

Calibration

To ensure the accuracy of measurement data, the probe must be inserted into the measurement material during measurement and maintain good contact.

Metal Mode Calibration

At the current position (whether on the wall or in the air), press and hold the metal button for 5 seconds. The green light will turn on again, indicating successful calibration.

Cable Mode Calibration

If the device emits an alarm sound in every corner of the room, this may be due to high humidity or strong static electricity on the wall. To calibrate, at the current position (on the wall or in the air), long press the button. The green light will turn on again, and the signal strength percentage will display 0%. Release the button to continue detection.

Wood Mode Calibration

Attach the device to the wall in an area confirmed to be free of objects for calibration (when there is no object, the display percentage should show 0% and no AC icon). Long press the wood mode button for 2 seconds. The green light will light up again, and a beep will sound. Release the button to continue detection.

Component Description

Technical Specifications

ParameterSpecification
Maximum detection depthFerrous metals: 4-3/8" / 120mm
Non-ferrous metals (copper): 3-1/8" / 80mm
Copper wire (≥4mm²): 2" / 50mm (220V@50Hz/110V@60Hz)
Foreign body mode (wood detection): Exact 20mm / Deep 38mm
Moisture detection depth: 0.3" / 8mm
Metal pattern (moisture): 0-85% RH
Foreign body mode (moisture): 0-60% RH
Moisture detection depth (Wood): 5%-50% RH / ±2%
Building materials (moisture): 1.4%-33% RH / ±2%
General parametersAutomatic shutdown time: 5 Mins
Range of working temperature: -10°C to 50°C / 14°F to 122°F
Storage temperature range: -20°C to 70°C / -4°F to 158°F
Working humidity range: 35%-55% RH
Battery1 x 9V Battery

*Repeated detection multiple times to improve accuracy.

Maintenance, Service, and Cleaning

Disposal of Waste

Damaged detectors, product accessories, and packaging must be recycled and used in a manner that meets environmental requirements. When the product is not in use, the battery must be removed from the instrument. If left for a long time, the battery may corrode or discharge automatically.

The right to modify is reserved.

Models: Stud Finder, DMS05

PDF preview unavailable. Download the PDF instead.

B1P gHyHxWS

Related Documents

Preview TACKLIFE DMS03 Stud Finder User Manual: Detect Studs, Metal, and AC Wires
This user manual provides detailed instructions for the TACKLIFE DMS03 stud finder, covering battery installation, operation modes for detecting studs, metal, and AC wires, calibration, specifications, and maintenance.
Preview Tacklife DMS05 Stud Finder User Manual
User manual for the Tacklife DMS05 Stud Finder, detailing its features, operation, and technical specifications for detecting metals, wood studs, and AC wires, as well as measuring moisture content.
Preview TACKLIFE DMS03 Stud Finder User Manual: Detect Studs, Metals, and Wires
Comprehensive user manual for the TACKLIFE DMS03 Stud Finder. Learn how to accurately detect studs, metal objects, and live AC wires in walls, ceilings, and floors. Includes technical specifications and operating instructions for safe and efficient project planning.
Preview TACKLIFE VT02 Advanced AC Voltage Detector User Manual
User manual for the TACKLIFE VT02 Advanced AC Voltage Detector, providing safety information, operating instructions, technical specifications, and warranty details.
Preview TACKLIFE PID03B Hammer Drill User Manual
This user manual provides comprehensive safety instructions, operating procedures, and technical specifications for the TACKLIFE PID03B Hammer Drill, ensuring safe and effective use of the power tool.
Preview TACKLIFE Miter Saw User Manual EMS01A
Comprehensive user manual for the TACKLIFE Miter Saw Model EMS01A, covering safety instructions, device description, operation, maintenance, and troubleshooting.
Preview TACKLIFE PCD04C Cordless Impact Drill/Driver User Manual
Comprehensive user manual for the TACKLIFE PCD04C Cordless Impact Drill/Driver, covering safety instructions, specifications, product features, battery usage, and charging procedures.
Preview TACKLIFE PBS01A Bandsaw: User Manual and Operating Guide
Comprehensive user manual for the TACKLIFE PBS01A Bandsaw, covering setup, operation, safety guidelines, maintenance, and troubleshooting for woodworking enthusiasts.