KMC Controls Sensor and Thermostat Selection Guide

Introduction to KMC Sensors and Thermostats

KMC Controls manufactures a comprehensive range of pneumatic, analog electronic, and digital sensors and thermostats designed for various HVAC and Building Automation System (BAS) applications. These devices are crucial for monitoring and controlling environmental conditions, with some sensing a single variable like temperature, while others measure multiple variables such as humidity and CO₂.

Sensors are fundamental components that measure physical characteristics of an environment and translate them into signals for control devices. Transmitters are a type of sensor that amplifies and converts these signals into active voltage or current outputs, enabling longer transmission distances. Transducers, while operating on different physical principles, also function as sensors by converting one form of energy to another, often used for pressure or signal conversions in BAS.

Thermostats integrate a sensor with a control device, ranging from simple mechanical switches to advanced digital units. This guide provides an overview of KMC Controls' sensor and thermostat offerings.

For detailed product specifications and further information, consult the KMC Controls website and product data sheets.

KMC Controls, 19476 Industrial Drive, New Paris, IN 46553 | Phone: 877-444-5622 | Fax: 574-831-5252 | Website: www.kmccontrols.com

Thermostats (Integrated Room Temperature Sensor Plus Controller)

Typical ApplicationsTypeDisplayFeaturesModelsVisual Description
AHU, FCU, HPU, RTU, and Custom ApplicationsDigital B-AACLCDBACnet Advanced Application Controller; optional humidity, motion, and CO₂ sensors; programmableBAC-12xxxx, BAC-13xxxx, and BAC-14xxxx FlexStatImage of a KMC FlexStat thermostat with an LCD display.
FCU, HPU, RTUDigital B-ASCColor LCDBACnet Application Specific Controller; optional humidity and motion sensors, configurableBAC-4xxxCW000x AppStatImage of a KMC AppStat thermostat with a color LCD display.
FCU and Baseboard HeatingAnalog ElectronicLCDSix-wire modular jack, single setpointCTE-5201-16Image of a KMC CTE-5201-16 thermostat with an LCD display.
VAV, FCU, Baseboard Heating, and Chilled BeamAnalog ElectronicLCD"Universal" analog electronic replacement, dual setpoint, two analog outputsCTE-5202Image of a KMC CTE-5202 thermostat with an LCD display.
VAVAnalog ElectronicMechanical Indicator on ScaleDesigned for use with CEE/CEP/CSE/CSP-4xxx controller-actuators, single and dual setpoints (replaced by CTE-5202)CTE-100x and CTE-110xImage of KMC CTE-100x/110x thermostats with mechanical dials.
VAVAnalog ElectronicMechanical Indicator on ScaleDesigned for use with CSP-500x controller-actuators, single and dual setpoints (replaced by CTE-5202)CTE-510xImage of a KMC CTE-510x thermostat with a mechanical dial.
VAV and FCUPneumaticMechanical Indicator on Scale1- and 2-pipe, DA and RACTC-16xxImage of a KMC CTC-16xx pneumatic thermostat with a mechanical dial.

Temperature Sensors (Room)

TypeDisplayFeaturesModelsVisual Description
DigitalLCDFor BAC/KMD-58xx and BAC/KMD-7xxx controllers, optional humidity and motion sensorsKMD-1xxx NetSensorImage of a KMC KMD-1xxx NetSensor with an LCD display.
DigitalLCDFor BAC-8xxx SimplyVAV controller-actuatorsSTE-8xxx NetSensorImage of a KMC STE-8xxx NetSensor with an LCD display.
DigitalLCDFor BAC-59xx and BAC-9xxx controllers; optional humidity, motion, and CO₂ sensorsSTE-9xxx NetSensorImage of a KMC STE-9xxx NetSensor with an LCD display.
Thermistor, 10K, Type II and TransmitterLCD or NoneThermistor only or active voltage option, override and setpoint adjustment options, screw terminals or modular jack connectionSTE-60xxImage of a KMC STE-60xx sensor with screw terminals.
Thermistor, 10K, Type IIINoneFlat wall plate with hidden thermistorSTE-1430Image of a KMC STE-1430 wall plate sensor.
Analog Electronic TransmitterNoneWall-mounted humidity transmitters with temperature sensors (thermistors)THE-1102 and THE-1105Image of KMC THE-1102/1105 wall-mounted humidity/temperature transmitters.
Analog Electronic TransmitterNoneFor use with CTE-110x/510x thermostatsTTE-1001Image of a KMC TTE-1001 transmitter.

Temperature Sensors (Other)

TypeDisplayFeaturesModelsVisual Description
Analog Electronic (Thermistor)NoneDuct, immersion, outside air, strap-on optionsSTE-14xxImage of a KMC STE-14xx sensor for duct/immersion mounting.
Analog Electronic (Thermistor)NoneDuct-mounted humidity transmitter with temperature sensorTHE-1002Image of a KMC THE-1002 duct-mounted humidity/temperature transmitter.
Analog Electronic (Thermistor)NoneDuct flow sensor with temp. sensing (for REE-1005)SSE-20xxImage of a KMC SSE-20xx duct flow sensor.
Analog Electronic (Thermistor)NoneDuct temperature transmitter for use with CEE-11xx remote thermostat controllersTTE-2001Image of a KMC TTE-2001 duct temperature transmitter.

Humidity Sensors

TypeDisplayFeaturesModelsVisual Description
DigitalLCDFor BAC/KMD-58xx and BAC/KMD-7xxx controllers, optional humidity and motion sensorsKMD-1xxx NetSensorImage of a KMC KMD-1xxx NetSensor with an LCD display.
DigitalLCDFor BAC-8xxx SimplyVAV controller-actuatorsSTE-8xxx NetSensorImage of a KMC STE-8xxx NetSensor with an LCD display.
DigitalLCDFor BAC-59xx and BAC-9xxx controllers; optional humidity, motion, and CO₂ sensorsSTE-9xxx NetSensorImage of a KMC STE-9xxx NetSensor with an LCD display.
Analog Electronic (Thermistor)NoneDuct-mounted humidity transmitter with temperature sensorTHE-1002Image of a KMC THE-1002 duct-mounted humidity/temperature transmitter.
Analog Electronic TransmitterNoneCompact wall-mounted humidity transmitter with temperature sensor (thermistor)THE-1102Image of a KMC THE-1102 wall-mounted humidity/temperature transmitter.
Analog Electronic TransmitterNoneWall-mounted humidity transmitter with temperature sensor (thermistor)THE-1105Image of a KMC THE-1105 wall-mounted humidity/temperature transmitter.

CO, CO₂, and Smoke Sensors

TypeDisplayFeaturesModelsVisual Description
Smoke—Analog Electronic (Contacts)NoneDuct smoke detectorCAE-1x03Image of a KMC CAE-1x03 duct smoke detector.
CO—Analog ElectronicLCDCO sensors, room and ductSAE-11xxImage of a KMC SAE-11xx CO sensor with an LCD display.
CO₂—Analog ElectronicLCDCO₂ sensors, room and ductSAE-10xxImage of a KMC SAE-10xx CO₂ sensor with an LCD display.
CO₂—DigitalLCDDigital wall sensor for BAC-59xx and BAC-9xxx controllersSTE-9xxx NetSensorImage of a KMC STE-9xxx NetSensor with an LCD display.

Flow and Pressure Sensors

TypeDisplayFeaturesModelsVisual Description
Analog ElectronicNoneFor use with CEP-4xxx controllersSSE-1000/2000Image of KMC SSE-1000/2000 sensors.
Pneumatic (but used with electronic and digital controller)NonePick-up tubes for use with controllers that have flow and pressure sensorsSSS-10xxImage of KMC SSS-10xx pick-up tubes.
Analog Electronic TransducerNoneGauge pressure transducers (P-E/I)TPE-1464-xImage of a KMC TPE-1464-x pressure transducer.
Analog Electronic TransducerNoneLow pressure transducersTPE-1475-2x and TPE-1477-2xImage of KMC TPE-1475-2x/1477-2x low pressure transducers.
Analog Electronic TransducerNoneLiquid differential pressure transducers (P-E/I)TPE-1483-xImage of a KMC TPE-1483-x differential pressure transducer.

Refrigerant Monitor

TypeDisplayFeaturesModelsVisual Description
Analog ElectronicNoneFirstWatch refrigerant sight glass monitorSLE-1001Image of a KMC SLE-1001 refrigerant monitor.

Miscellaneous

KMC Controls also offers a wide range of Veris data servers, current transformers, monitors, meters, sensors, and accessories to complement a complete BAS installation. For detailed product descriptions and specifications, visit Veris.com and use the search function.

Digital/Electronic Handling Precautions

When installing, servicing, or operating digital and electronic sensors, thermostats, and controllers, take precautions to prevent electrostatic discharge (ESD). Discharge accumulated static electricity by touching a grounded object before handling devices.

NOTICE: OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE DEVICES.

[ESD Warning Symbol: Triangle with lightning bolt and hand icon]

Important Notices

KMC Controls and its logo are registered trademarks of KMC Controls, Inc. Other product and brand names mentioned are trademarks of their respective owners.

All rights reserved. Reproduction, transmission, or translation of this publication without written permission from KMC Controls, Inc. is prohibited.

The information in this document is for informational purposes only and is subject to change without notice. KMC Controls, Inc. makes no warranties regarding this document and is not liable for any damages arising from its use.

Support

Additional resources, including product specifications, installation guides, configuration details, and application support, are available on the KMC Controls website (www.kmccontrols.com). Access to all files requires logging into the KMC Partners site.

[Image: Computer monitor and tablet displaying KMC Controls branding and product information]

PDF preview unavailable. Download the PDF instead.

sss-1000 selectionguide Adobe InDesign CC 2015 (Windows) Adobe PDF Library 15.0

Related Documents

Preview KMC Controls Sensor and Thermostat Selection Guide
Comprehensive selection guide for KMC Controls' range of HVAC and Building Automation System (BAS) sensors and thermostats, including digital, analog, and pneumatic models with detailed features and applications.
Preview KMC Airflow Measurement System (AFMS) Gen6 Controller, Sensors, and Actuator
Learn about the KMC Airflow Measurement System (AFMS) Gen6, designed for accurate and reliable measurement of outdoor, return, and supply airflow in HVAC systems. This system enhances building wellness and indoor air quality assurance.
Preview KMC Room Sensor and Thermostat Mounting and Maintenance Application Guide
Comprehensive guide from KMC Controls on the proper mounting, installation, and maintenance of their room sensors and thermostats for optimal performance, including troubleshooting tips and best practices.
Preview STE-9000 Series NetSensors Installation Guide | KMC Controls
Step-by-step installation guide for KMC STE-9000 Series NetSensors, detailing mounting, wiring, and connection to Conquest controllers. Includes important notices and contact information.
Preview KMC Conquest Airflow Measurement System Installation Guide
This guide provides comprehensive instructions for installing and configuring the KMC Conquest Airflow Measurement System (AFMS), including various sensors, controllers, and network connections for optimal HVAC system performance.
Preview KMC STE-9000 Series Digital Room Sensors Quick Reference Guide
Quick reference guide for KMC STE-9000 Series NetSensors, detailing control buttons, occupancy modes, features, and support resources for digital space temperature sensors used with KMC Conquest controllers.
Preview KMC Conquest Gen5 Controllers Application Guide
This comprehensive application guide details KMC Conquest Gen5 controllers, covering installation, configuration, sequences of operation for HVAC systems, and troubleshooting. It is a key resource for building automation professionals.
Preview KMC Conquest Airflow Measurement System Installation and Wiring Guide
Comprehensive guide for installing and wiring the KMC Conquest Airflow Measurement System (AFMS), including models BAC-5901AC(E)-AFMS and BAC-9311AC(E)-AFMS. Covers component mounting, sensor connections, network setup, and power requirements for efficient HVAC system control.