ActiveShop Giovanni D-21 Vapozone with Magnifying Lamp
Imported by: z o.o., ul. Graniczna 8b, bud. DC2A 54-610 Wrocław, Poland
Website: www.activeshop.com.pl
Revision: A/04/2025
Product Overview
The Giovanni D-21 is a multifunctional vapozone with warm steam and ozone. It features high-quality craftsmanship, intuitive operation, and is ideal for use in any beauty salon. The device is mounted on a lightweight, functional, and stable stand with a telescopic arm for quick adjustments. The height of the vapozone is adjustable.
Device Functions
- Disinfects the skin
- Expands pores
- Facilitates the removal of blackheads and dead skin due to deep steam penetration
- Promotes the excretion of toxins
- Hydrates and refreshes the skin
- Stimulates skin circulation
- Significantly improves massage results
Specifications
- On/Off switch and timer
- Hole/filler
- Gooseneck tube
- Light on/off switch
- Magnifying lens (x3)
- Nozzle for hot steam emission
- Sprayer tube
- Main body
- Telescopic stand (upper column; 2in1)
- Telescopic stand (lower column)
- Base
- Wheels
- Cover
- Water tank
Operating Instructions
- Place the device on a stable, flat surface.
- Ensure the hot water seal is tightened. Fill the water level until it approaches the MAX level.
- Set the desired operating time (between 0 and 30 minutes) by turning the timer knob.
- Turn on the device by pressing the on/off button. The device will begin heating the water, and the UV lamp will also turn on. Steam emission will start approximately 5 minutes after the water boils. The time may vary depending on the amount of water.
- The UV light can be controlled individually. Press and hold the on/off button for 5 seconds to turn the UV light on or off.
- When steam begins to rise, bring the device closer to the client's face. The ideal distance between the nozzle and the client's face is at least 20 cm.
- If the device will not be used for an extended period, empty the water and dry the tank.
Warnings
CAUTION!!! Do not bring the device too close to the client's face or body. There is a risk of severe skin burns.
CAUTION! Do not tilt or tip the device during operation. Do not use the device if it is empty of water.
CAUTION!!! Do not pour essential oils or any liquids other than water into the water tank. This may cause damage to the device or personal injury.
Recommendations
- Never leave a connected device unattended. Close supervision is necessary when this device is used by or near children or persons with disabilities.
- Use the device only for its intended purpose as described in the user manual.
- Never use this device if the cord or plug is damaged. Do not use the device if it malfunctions, has been dropped, damaged, or fallen into water.
- Never use the device while sleeping.
- Use the device only on a flat surface.
- Never use the device too close to the skin, as there is a risk of burns.
- Do not add essential oils or other additives to the water in the tank. Failure to do so may result in damage to the device.
- Do not use the device if it is empty of water.
- Do not pour any additives into the water tank.
- Clean the water tank regularly. Remember to turn off and unplug the device before cleaning.
- Do not touch the hot water tank.
- Do not touch the water tank when the device is switched on.
- When finished, empty the water and dry the tank.
Device Assembly
Follow the diagram for assembly.
CAUTION!!! Do not use a rough cloth to clean the lens. Doing so may scratch the lens and reduce its clarity.
CAUTION!!! Do not expose unprotected eyes to direct LED light, as this may cause discomfort or vision damage.
CAUTION!!! The water tank must be cleaned regularly. Unplug the device from the mains before removing the water tank.
The device height is adjustable from 78-95 cm, allowing the equipment to be positioned at the optimal height for maximum comfort for the operator and client. The LED magnifier and vapozone nozzle can be rotated to increase the range and treatment area.
Technical Data
Voltage | Power | Lamp Brightness | Lamp Power |
120-220 V 50/60 Hz | 750 W | 1000-1600 Lx | 9.5 W |
Device Dimensions
The device has adjustable height from 78-95 cm. The steam nozzle arm extends approximately 45 cm, and the main body has a height of 24 cm. The base has a width of 53 cm.
Safety Precautions
- The device is professional equipment for cosmetic procedures. Operation by qualified cosmetic personnel is recommended to avoid undesirable effects during treatment.
- The device should not be disassembled or used for purposes other than those specified in this user manual. All servicing and repairs must be carried out exclusively by authorized service technicians (ACTIVESHOP Sp. z o.o.).
- The device should not be installed or operated near liquids, wet areas, or with wet hands, to prevent liquids from entering the device.
- In the following cases, immediately unplug the device and contact the official service company ACTIVESHOP Sp. z o.o.: a) liquid has entered the device, b) the device emits a strange odor, smoke, or makes unusual noises, c) the power cord is damaged, d) the device has been overturned or its housing is damaged.
- Do not place any objects on the cables. Do not place the device where the power cable can be stepped on.
- For safety reasons, unplug the power cable from the outlet every time you finish working with the device.
- Do not insert anything into the device's openings. If a foreign object enters an opening, unplug the cord and contact the distributor or manufacturer.
- Do not place the device on an unstable trolley, shelf, or vehicle. The device may be damaged if it falls, causing damage.
- To ensure the fixed lifespan of the device, it is recommended to observe a one-minute pause before pressing the power button again (switching on and off and vice versa).
- The power supply must comply with the specifications on the rating plate. Otherwise, there is a risk of device malfunction, damage, or even burnout.
CAUTION!
- In case of damage to the power cord or other malfunctions, contact an authorized service center to avoid hazards.
- This device can be used by children aged at least 8 years, as well as persons with reduced physical and mental capabilities, or lack of experience and knowledge regarding the device, provided that supervision or instruction is provided for the safe use of the device to understand the associated risks.
- Children should not play with the equipment. Do not allow children to play with the device.
- Do not leave the device unattended when children or persons without adequate knowledge are using the device nearby.
- This electrical appliance is not a toy. Improper use or contact with the electrical appliance can pose health risks or lead to death, therefore the device should be used and stored out of reach of children.
Device Disposal
Used electrical appliances, fittings, and packaging should be disposed of at recycling centers in accordance with environmental protection principles. Electrical appliances should not be placed in household waste bins. Comply with the regulations for the disposal of this type of equipment. For environmental protection, in accordance with Directive 2012/19/EU on waste electrical and electronic equipment, waste electrical and electronic equipment must be collected separately and handed over at collection points for waste electrical and electronic equipment.
Used and old devices contain fully recyclable components and should therefore be handed over for recycling. Therefore, they should be taken to appropriate collection points, as well as ACTIVESHOP Ltd.
Storage and Transport
The device should only be transported in its original packaging, at temperatures between (-) 20°C and (+) 50°C. The device should be stored in a well-ventilated room with a relative humidity of no more than 75%. The operating temperature is between (+) 10°C and (+) 40°C. During storage and transport, the device should not be thrown or dropped, or exposed to mechanical shocks or atmospheric effects.