The Vapozon Giovanni D-21 is a multifunctional device with warm steam and ozone. It is characterized by high-quality workmanship, intuitive operation, and a stable tripod. Its lightweight and functional design makes it an excellent opportunity for work in any beauty salon. The telescopic arm allows for quick adjustment, and the vapozone is set on a tripod with adjustable height.
Operation of the Device:
- Disinfects the skin
- Expands pores
- Facilitates removal of blackheads and dead skin by penetrating steam deep into the skin
- Facilitates the secretion of toxins
- Moisturizes and refreshes the skin
- Stimulates skin circulation
- Significantly improves massage results
Specifications:
- On/off switch and switch timer
- Hole/filler
- Gooseneck type tube
- Light on/off switch
- Magnifying lens x3
- Nozzle, emitting hot steam
- Spray tube
- Main body
- Telescopic stand (top post; 2-in-1)
- Telescopic stand (bottom post)
- Base
- Casters
- Cover
- Water container
Instructions for Use:
- Place the unit on a stable, flat surface.
- Check that the hot water seal is tightly clamped. Refill the water level until it approaches the MAX level.
- Turn the timer knob to set the desired operating time of the device (from 0 to 30 minutes).
- Turn on the device by pressing the on/off button. The device will start heating water, and the UV light will come on. Steam will begin to spray about 5 minutes after the water boils. The time may vary depending on the amount of water.
- The UV light can be controlled individually. Press and hold the on/off button for 5 seconds to turn the UV light on or off.
- When the steam starts coming out, bring the device closer to the customer's face. The ideal distance between the nozzle and the customer's face is not less than 20 cm.
- If the device is not used for a long time, pour out the water and dry the container.
CAUTION!!!
- Do not bring the device face or body of the customer too close. This may cause serious skin burns.
- While the device is operating, do not tilt or tip it over. Do not use the device if there is no water in it.
- Do not pour essential oils or any other liquid other than water into the water tank. This can lead to damage to the device or physical injury.
Recommendations:
- Never leave a connected device unattended. Close supervision is necessary when this device is used by, on, or near children or persons with disabilities.
- Use the device for the purpose described in the manual.
- Never use this device if it has a damaged cord or plug. Do not use the device if it is not working properly or if it has been dropped, damaged or fallen into water.
- Never use the device while sleeping.
- Use the device only on a level surface.
- Never use the device too close to your skin; it risks burns.
- Do not add any essential oils or other additives to the water in the reservoir. Otherwise, the device may be damaged.
- Do not use the device if there is no water in it.
- Do not pour any additives into the water container.
- Clean the water tank regularly. Remember to turn off the device and unplug it before cleaning.
- Do not touch the hot water tank.
- Do not touch the water tank when the device is on.
- When you are done, pour out the water and dry the tank.
Installation of the Device:
Follow the diagram provided for installation.
CAUTION!!!
- Do not use a rough cloth to clean the lens. Doing so can scratch the lens and reduce its transparency.
- Do not expose unshielded eyes to direct LED light; it may cause discomfort or damage to vision.
- Clean the water container regularly. Before removing the water container, disconnect the device from the power supply.
Parts List:
Part | Quantity | Image Description |
A | 1PCS | Main body assembly |
B | 1PCS | Spray tube |
C | 1PCS | Telescopic stand (bottom post) |
D | 1PCS | Base component |
E | 1PCS | Base component with casters |
F | 2PCS | Telescopic stand (top post) |
G | 4PCS | Screws for base assembly |
H | 1PCS | Magnifying lamp assembly |
I | 1PCS | Gooseneck tube |
J | 4PCS | Screws for lamp assembly |
The height of the device can be adjusted from 78-95 cm, allowing for optimal positioning for both the operator and the client. The LED magnifier and the vapozone nozzle can be rotated, increasing the range and field of the treatment.
Technical Data:
Parameter | Value |
Voltage | 120-220 V 50 / 60 Hz |
Power | 750 W |
Lamp brightness | 1000-1600 Lx |
Lamp power | 9.5 W |
Dimensions of the device:
The device has adjustable height and rotatable components for flexible positioning.
Safety Measures:
- The device is professional equipment for beauty parlors. Operation should only be performed by qualified cosmetic personnel.
- Do not disassemble the device or use it for purposes other than those indicated in this manual. All servicing and repairs must be performed only by an authorized service technician from ACTIVESHOP Ltd.
- Do not install or operate the device near liquids, wet places, or with wet hands to prevent liquids from entering the device.
- Immediately remove the plug from the outlet and contact authorized service if: a) liquid has gotten into the device, b) the device emits a strange smell, smoke, or makes strange sounds, c) the power cord is damaged, d) the device has been knocked over or its housing is damaged.
- Do not lay any objects on the cables. Do not install the device where someone may step on the power cord.
- For safety purposes, unplug the power cord from the outlet each time you finish working with the device.
- Do not insert anything into the opening of the device. If a foreign object gets into a hole, remove the cord from the outlet and contact the distributor or manufacturer.
- Do not place the device on an unstable cart, shelf, or vehicle. In case of a fall, the device may be damaged.
- To guarantee the established useful life of the device, it is recommended to keep an interval of one minute before pressing the power button again (between switching on and off and vice versa).
- The power supply must comply with the specifications on the nameplate. Otherwise, there is a risk of incorrect operation, damage, or even burning of the device.
CAUTION:
- In case of damage to the power cord or other malfunctions, contact an authorized service center to avoid danger.
- This device can be used by children aged 8 and above, and by persons with reduced physical and mental capabilities and persons with inexperience and lack of familiarity with the equipment, if supervision or instruction is provided on how to use the equipment in a safe manner, so that the associated risks are understood.
- The equipment is not intended for play by children. Do not allow children to play with the equipment.
- Do not leave the device unattended when children or persons without sufficient knowledge of the use of the appliance are in its vicinity.
- This electrical appliance is not a toy. Improper use or contact with the electrical appliance may pose a health risk or lead to death, so use and store the appliance out of the reach of children.
Disposal of the Device:
Dispose of used electrical appliances, fixtures, and packaging at raw material reprocessing centers in accordance with environmental protection principles. Do not dispose of electrical appliances in household waste containers. Follow the rules for discarding this type of equipment. In order to protect the environment in accordance with Directive 2012/19/EC concerning waste electrical and electronic equipment, waste electrical equipment should be collected separately and then handed over to collection centers for waste electronic and electrical equipment. At the end of their useful life, old appliances contain full-value recyclable components, so they should be handed over for reprocessing. Therefore, they should be handed over to appropriate collection points, and they can also be handed over to ACTIVESHOP Ltd.
Storage and Transport:
The device should be transported at a temperature in the range of -20°C to +50°C only in its original packaging. Store the device in a well-ventilated room and a relative humidity of no more than 75%. Operating temperature from +10°C to +40°C. During storage and transportation, the device must not be thrown, dropped, exposed to mechanical shocks, or atmospheric agents.