SA1BE4M1 Series Residential Split System Air Conditioner

Quick Reference Data

Table 1. Electrical Specifications & Physical Data

MODEL NUMBER: *SA1BE4M1SN 18K 24K 30K 36K 42K 48K 60K
Volts-Cycles-Phase (1) 208/230-60-1
ELECTRICAL DATA Total Amps 10.0 14.4 15.0 15.1 19.4 21.3 29.0
Delay Fuse Max. (2) 20 30 30 30 40 45 60
Min. Circuit Ampacity 12.4 17.7 18.5 18.6 23.9 26.3 35.6
Coil Area 10.0 11.7 15.2 20.3 22.8 22.8 25.4
Rows-FPI 1-23 1-23 1-18 1-18 1-18 1-18 1-23
Tube Dia MC
CONDENSER DATA Fan Motor Type PSC BLDC
Amps 0.9 0.9 0.9 1.0 1.5 1.5 2.6
HP 0.13 0.13 0.13 0.20 0.25 0.25 0.33
Compressor Data RLA 9.3 13.4 14.1 14.1 17.9 19.8 26.4
LRA 56.6 58.3 73.0 77.0 112.0 109.0 134.0
RECOMMENDED REFRIGERANT SUCTION LINE O.D* 0-24 ft. 3/4" 3/4" 3/4" 3/4" 7/8" 7/8" 7/8"
25-39 ft. 3/4" 3/4" 3/4" 7/8" (3) 7/8" 7/8" 1-1/8" (4)
40-75 ft. 3/4" 3/4" 3/4" 7/8" (3) 7/8" 7/8" 1-1/8" (4)
REFRIGERANT CHARGE: R-410A in ounces for outdoor unit, indoor unit and 15' line set. (5) 34 39 48 57 66 96 81
APPROXIMATE WEIGHT (LBS.) Net 181 123 147 166 198 199 212
Ship 195 138 168 189 222 223 236

(1) Operating Voltage Range: 187v min. – 253v max.

(2) HACR Type Circuit Breakers may be used.

(3) Requires 7/8" to 3/4" reducer from line to unit.

(4) Requires 7/8" to 1-1/8" reducer from line to unit.

(5) Additional charge for line sets above 15 feet. Values based on suction line as follows with 3/8" liquid line:

* For other line set dimensions, refer to the Application Guidelines for Refrigerant Lines Addendum.

Table 2. Control Wiring (24V)

WIRE GAUGE RECOMMENDED MAXIMUM WIRE LENGTH (FT) FROM UNIT TO THERMOSTAT
22 45
20 70
18 115
16 180

Figure 1. Clearance Requirements

A diagram showing recommended clearances for the outdoor unit. The diagram indicates:

  • 6" from Building or Structure
  • 24" for Service Access
  • DO NOT OBSTRUCT
  • TOP OF UNIT
  • 12" or 18" clearance from sides and bottom (See Note)

NOTE: Units require full perimeter clearances. Installer must maintain 18" between two units or 12" between single unit and structure.

A 2" Mounting Pad is shown at the bottom.

Table 3. Unit Dimensions

A table listing the dimensions (Height, Width, Depth) for various SA1BE4M1SN models:

Model *SA1BE4M1 Shown MODEL NUMBER HEIGHT (H) WIDTH (W) DEPTH (D)
*SA1BE4M1SN18K 28 1/2" 23 3/4" 23 3/4"
*SA1BE4M1SN24K 32 1/2" 23 3/4" 23 3/4"
*SA1BE4M1SN30K 29 1/4" 31 3/4" 31 3/4"
*SA1BE4M1SN36K 37 1/4" 31 3/4" 31 3/4"
*SA1BE4M1SN42K 41 1/4" 31 3/4" 31 3/4"
*SA1BE4M1SN48K 41 1/4" 31 3/4" 31 3/4"
*SA1BE4M1SN60K 45 1/4" 31 3/4" 31 3/4"

Table 4. REQUIRED RESTRICTOR OR TXV (CHARGE ADDITION (OZ) / RATED AIRFLOW -SCFM)

This table provides guidance on the required restrictor or TXV and charge addition for various combinations of outdoor and indoor units. It includes instructions for identifying the correct match and notes on necessary changes.

Instructions:

  1. Find the column for the model of outdoor unit that is being installed.
  2. Find the row for the model of the indoor unit that is being installed.
  3. Find the cell in the table where this row and column meet. This cell lists the appropriate orifice/TXV and charge addition for this match. If the text in this cell is BOLD, then a change of orifice is necessary.
  4. If a change in restrictor is necessary, then the appropriate restrictor will already be supplied with the outdoor unit.

Examples:

MODEL NUMBER: *SA1BE4M1SN 18K 24K 30K 36K 42K 48K 60K
ID RESTRICTOR SUPPLIED WITH OD UNIT: 0.051 0.057, 0.058 0.062 0.068, 0.069 0.077
OUTDOOR UNIT BOM CHARGE (OZ.) 34 39 48 57 66 96 81
ID RESTRICTOR INSTALLED WITH ID UNIT MODELS SUPPLIED WITH ID REQUIRED RESTRICTOR OR TXV (CHARGE ADDITION (OZ) / RATED AIRFLOW -SCFM)
B6BM-X
B6BM-X24K-A 669564 669564 (18/600) 669564 (23/705) -- -- -- -- --
B6BM-X24K-B 669564 669564 (18/600) 669564 (23/705) -- -- -- -- --
B6BM-X30K-A 669565 -- 669565 (21/875) -- -- -- -- --
B6BM-X30K-B 669565 -- 669565 (21/875) -- -- -- -- --
B6BM-X36K-B 669566 -- -- 669567 (19/1225) -- -- --
B6BM-X42K-B 669567 -- -- -- 669568 (22/1450) -- --
B6BM-X48K-C 669568 -- -- -- -- 669578 (29/1660) --
B6BM-X60K-C 669578 -- -- -- -- -- --
B6BMM0 0.051 0.058 (14/800) 0.051 0.058
B6BMM024K-A 0.055 (18/660) 0.058 (14/800) -- -- -- -- --
B6BMM024K-B 0.055 (18/660) 0.058 (14/800) -- -- -- -- --
B6BMM030K-A 0.062 -- 0.062 (3/895) -- -- -- --
B6BMM030K-B 0.062 -- 0.062 (3/895) -- -- -- --
B6BMM042K-B 0.074 -- -- 0.069 (11/1225) 0.074 (13/1260) -- --
B6BMM060K-C 0.087 -- -- -- -- 0.077 (-15/1440) 0.087 (8/1635)
B6BMMX B6BMMX24K-A 669564 669564 (0/600) 669564 (0/715) -- -- -- -- --
B6BMMX24K-B 669564 -- 669564 (2/715) -- -- -- -- --
B6BMMX30K-A 669565 -- 669565 (0/945) -- -- -- -- --
B6BMMX30K-B 669565 -- 669565 (0/1015) -- -- -- -- --
B6BMMX36K-B 669566 -- -- 669566 (13/1190) -- -- --
B6BMMX48K-C 669568 -- -- -- 669568 (22/1375) 669568 (0/1670) --
B6BMMX60K-C 669578 -- -- -- -- -- 669578 (3/1545)

NOTES:

THE CHARGE ADDITIONS PROVIDED IN THIS DOCUMENT ARE ESTIMATES BASED ON TEST DATA AND SHOULD ONLY BE A STARTING POINT. AFTER FOLLOWING THESE DIRECTIONS PLEASE ADJUST THE REFRIGERANT AMOUNT BASED ON THE APPROPRIATE CHARGING TABLES OR CHARTS IN THE INSTALLATION INSTRUCTIONS OR CHARGING LABEL.

PDF preview unavailable. Download the PDF instead.

1021481A Adobe PDF Library 15.0 Adobe InDesign CC 13.1 (Windows)

Related Documents

Preview GSA2QE4M1S Series Split System Air Conditioner Quick Reference Data
Quick reference data for the GSA2QE4M1S Series Split System Air Conditioner with Quick Connect Couplings, including physical data, refrigerant charge, and required restrictor or TXV information.
Preview VSA3BD4M Series Residential Split System Air Conditioner Quick Reference Data
Quick reference data for the VSA3BD4M Series Residential Split System Air Conditioner, including refrigerant line sizes, R-410A charge amounts, and required restrictor or TXV with charge addition for various indoor and outdoor unit combinations. This document provides essential specifications for installation and setup.
Preview SA3MD4M Series Split System Air Conditioner Quick Reference Data
Quick reference data for the SA3MD4M Series Split System Air Conditioner for Manufactured Housing, including physical data, refrigerant charge, and restrictor/TXV information.
Preview Split System Air Conditioner Installation Instructions for Manufactured Housing
Comprehensive installation guide for Nortek Global HVAC SA3MD4M1 series split system air conditioners, covering safety, electrical, refrigerant charging, and maintenance procedures for manufactured housing.
Preview B6BV Series Air Handler Technical Specifications and Features
Detailed technical specifications, features, benefits, electrical data, dimensions, and blower performance data for the B6BV Series Air Handler by Nortek Global HVAC.
Preview E7 Series Electric Furnaces: Technical Specifications, Features, and Accessories
Comprehensive technical specifications, features, benefits, model identification, electrical data, physical dimensions, airflow data, and accessories for the E7 Series Electric Furnaces manufactured by Nortek Global HVAC.
Preview KG7S Series High Efficiency Gas Furnaces Technical Specifications
Detailed technical specifications, features, benefits, and performance data for the KG7S Series High Efficiency Upflow/Horizontal and Downflow Gas Furnaces by Nortek Global HVAC. Includes model identification, dimensions, airflow data, and accessories.
Preview GSH2BE4M1(R,S)P Series Split System Heat Pump Replacement Parts
Comprehensive replacement parts list for the Nortek Global HVAC GSH2BE4M1(R,S)P Series 14 SEER split system heat pump designed for manufactured housing. Includes detailed part numbers for various components across different models.