This owner's guide contains important information about safety, use, and disposal. Familiarize yourself with all operating and safety instructions before use. Keep documents for future reference and pass them on with the product.

Intended Use: This product is designed for circulating air in indoor living spaces in the United States only. It is not intended for commercial or industrial use. Unauthorized use or product modification voids the warranty.

⚠️ WARNING: Risk to Children and Impaired Persons

Supervision is required for children 12 years and younger, and individuals with reduced physical, sensory, or mental capabilities, during installation, operation, cleaning, and maintenance. Ensure children do not play with the appliance, its parts, or packaging.

⚠️ INSTALLATION WARNING—To reduce risk of fire, electrical shock, and injury:

⚠️ SAFE USE WARNING—To reduce risk of fire, electrical shock, and injury:

⚠️ SERVICING WARNING—To reduce risk of fire, electrical shock, and injury:

User Servicing Instructions (Fuse Replacement):

  1. Turn off and unplug the appliance.
  2. Grasp the plug (not the cord) and disconnect from the outlet.
  3. For fuse replacement, use only a 5 Amp, 125 Volt fuse approved by Vornado Consumer Service.
  4. Use a small flat-head screwdriver to slide open the fuse cover on the plug.
  5. Gently lift each end of the fuse with the screwdriver to remove it.
  6. Install the replacement fuse by gently pushing each metal end into the receptacle one at a time. Do not push the center of the fuse, as it is fragile.
  7. Slide the fuse cover closed; it should fit completely in the plug without sticking out.
  8. Plug the appliance into the outlet and turn on the power.
  9. If the replacement fuse blows, a short-circuit may be present; discard or return for service.

Note: Do not replace the attachment plug. It contains a safety device (fuse, AFCI, LCDI) that should not be removed. Discard the product if the attachment plug is damaged.

Features

Image Description: The product is a Vornado Whole Room Circulator, shown from the side. It has a distinctive spiral grille pattern and a sturdy, U-shaped metal base. The Vornado logo is visible in the center of the grille.

Getting Started: Base Assembly

Image Description: Two diagrams illustrate the base assembly. The first shows the fan unit being attached to the base, with an arrow indicating to loosen pivot knobs (A) counter-clockwise. The second diagram is a close-up of the pivot mechanism, showing the pivot knob (A), a large rubber washer (B), and a small metal washer (C) in position.

  1. Loosen the pivot knobs (A) by turning them counter-clockwise.
  2. Insert the base between the large rubber washer (B) and the small metal washer (C).
  3. Once both sides of the base are installed, tighten the pivot knobs by turning them clockwise.

Note: Assemble the base only as shown.

Controls

Image Description: The back of the Vornado circulator is shown, with the control panel clearly visible. The control panel has a dial with settings labeled 'O' (power off), 'I' (Low speed), 'II' (Medium speed), and 'III' (High speed).

Power ON/OFF & Speed Selection: Use the dial to select High (III), Medium (II), Low (I) fan speed, or to turn the power off (O).

How to Use: Wall Mount Installation

Image Description: The back of the Vornado circulator is shown, with the keyholes labeled 'A'. The diagram illustrates how to position the fan on screws mounted to a wall.

  1. Locate the Key Holes (A) on the back of the product.
  2. On the wall, find and mark two circles for mounting. For the EXO51 HD, the circles should be 5 inches apart (center to center). For the EXO61 HD, they should be 5.5 inches apart (center to center).
  3. Note: It is recommended to use drywall anchors or mount on a solid surface or wall stud. Do NOT hang the product on the ceiling.
  4. Drill 2 #10 panhead screws into the drywall anchors, solid surface, or wall stud (screws are not included). Screws should be rated for a 10 lb vertical load each.
  5. Leave approximately 1¼ inches of each screw exposed.
  6. Place the wide portions of the Key Holes (A) over the heads of the two screws.
  7. Slide the product down until the screws are inside the narrow portion of the key holes, securing the product to the surface.

Note: Hang the product from a sturdy location using large screws that will support its weight. Ensure the mounting does not impede fan operation or damage the cord. Route the electrical cord safely to avoid tripping or pulling. Avoid placing the product where it could be easily bumped.

Cleaning

Grille Removal: Screwdriver required.

⚠️ WARNING: To reduce the risk of electrical shock and injury, unplug the circulator before removing the grille.

  1. Remove the 6 screws located on the front of the grille.
  2. Dust or wash the Front Grille with mild dishwashing soap. Do not place the grille in a dishwasher, as excessive heat can distort the plastic.
  3. To reattach, align the 6 screw holes and replace all the screws.

Image Description: The front grille of the Vornado circulator is shown. Callouts indicate the locations of six screws around the perimeter of the grille.

? Tip: Use the brush attachment on your household vacuum cleaner to remove any accumulated dust from the Front Grille and Air Inlets.

Cleaning: Blade Removal

Pliers recommended.

⚠️ WARNING: To reduce the risk of electrical shock and injury, unplug the circulator before removing the blade.

  1. First, remove the nut from the shaft by turning it clockwise to loosen. Remove the washer. Pull the blade straight out from the shaft.
  2. Wipe the Blade with a damp cloth. If the circulator is used in a greasy environment (e.g., kitchen), mild soap or a common household cleaner may be used. Do not use solvents. Do not place the blade in a dishwasher.
  3. To reattach, ensure the flat side of the shaft aligns with the corresponding flat side on the blade's socket. Push the blade onto the shaft until it is fully seated. Do not use a hammer, as this could damage the bearing. Reinstall the washer and nut.

Image Description: The fan unit is shown with the grille removed. A nut ('Nut') is highlighted, indicating its position securing the blade to the motor shaft.

Troubleshooting

PROBLEMPOSSIBLE CAUSE AND SOLUTION
The unit fails to power on.
  • Unit is not plugged in. Plug power cord into an electrical outlet.
  • Ensure unit fan speed setting is selected.
  • Plug fuse has blown. Replace fuse (See User Servicing Instructions).
  • Unit is damaged or needs repair. Cease usage, unplug, and contact Consumer Service.
  • The outlet is worn or damaged. Try another outlet or contact a qualified electrician.
Airflow is weak or slow.
  • Unit set to a low speed setting. Adjust to a higher speed setting.
  • Airflow is blocked. Remove obstruction.
  • Adjust direction of airflow towards the user.
GFCI has tripped.

Under certain conditions, a GFCI (Ground Fault Circuit Interrupter) outlet may trip when changing speeds. If this occurs, try an outlet not connected to a GFCI device. It may also indicate a weak or defective GFCI outlet. Contact a qualified electrician to check the GFCI outlet.

Warranty

Vornado Air LLC warrants this Whole Room Circulator ("Product") to the original consumer or purchaser to be free from defects in material or workmanship for five (5) years from the date of purchase. Vornado will repair or replace the Product at no cost if a defect is discovered within the warranty period.

For Warranty Service:

When contacting Vornado, please have your Product's model number and serial number, along with your name, address, city, state, zip code, email, and phone number.

Warranty Exclusions: This warranty does not cover defects resulting from abuse, modification, mishandling, improper maintenance, commercial use, unauthorized repair, damage during shipment, or acts of God. Using external devices that alter voltage/frequency or shipping to unintended countries voids the warranty. Unauthorized modifications or repairs by non-approved centers are not recommended and not covered.

Limitation of Liability: Repair or replacement is the exclusive remedy. Vornado is not liable for incidental or consequential damages. Implied warranties of merchantability or fitness for a particular purpose are limited to the duration of this warranty.

This warranty provides specific legal rights, which may vary by state.

Company Information:

Designed, engineered, and supported in Andover, KS.

© 2023 Vornado Air LLC. Andover, KS 67002. U.S. Patent Pending. Specifications subject to change without notice. Vornado® is a trademark owned by Vornado Air LLC.

Vornado Air, LLC
415 East 13th Street
Andover, Kansas 67002
800.234.0604 | vornado.com

Models: EXO51 HD Whole Room Circulator, EXO51 HD, Whole Room Circulator, Room Circulator, Circulator

PDF preview unavailable. Download the PDF instead.

EXO 51 HD-EXO 61 HD-Owners Guide Adobe InDesign 18.5 (Macintosh) Adobe PDF Library 17.0

Related Documents

Preview Vornado 293HD Whole Room Circulator Owner's Guide and Safety Instructions
Comprehensive owner's guide for the Vornado 293HD Whole Room Circulator, covering essential safety instructions, product features, setup, cleaning procedures, troubleshooting tips, and warranty information.
Preview Vornado Refresh 8 Whole Room Circulator Owner's Guide and Safety Instructions
Comprehensive owner's guide for the Vornado Refresh 8 Whole Room Circulator, including important safety instructions, features, getting started, cleaning, troubleshooting, and warranty information.
Preview Vornado OSCR32 Tower Circulator Owner's Guide
Comprehensive owner's guide for the Vornado OSCR32 Tower Circulator, detailing safety instructions, features, operation, assembly, troubleshooting, and warranty information.
Preview Vornado Whole Room Circulator Owner's Guide - Models 160, 360, 460, 560, 660
Owner's guide for Vornado Whole Room Circulators, including models 160, 360, 460, 560, and 660. Provides instructions on operation, safety, cleaning, and troubleshooting for optimal whole room air circulation.
Preview Vornado Model 80 Whole Room Circulator Use & Care Guide
Comprehensive use and care guide for the Vornado Model 80 Whole Room Circulator, detailing features, controls, cleaning procedures, troubleshooting tips, and warranty information.
Preview Vornado Whole Room Circulator Owner's Guide
Comprehensive owner's guide for Vornado Whole Room Circulators, including safety instructions, features, setup, cleaning, troubleshooting, and warranty information for models 1303, 5303, 6303, 6803, 7503, and 7803.
Preview Vornado OSC73 Oscillating Tower Circulator Owner's Guide | Safety, Features, How-To
Comprehensive owner's guide for the Vornado OSC73 Oscillating Tower Circulator. Includes safety instructions, features, setup, operation, cleaning, troubleshooting, and warranty information.
Preview Vornado TRANSOM Window Circulator Owner's Guide & Manual
Comprehensive owner's guide for the Vornado TRANSOM Window Circulator. Learn about safety, features, installation, operation, cleaning, troubleshooting, and warranty. Get the most out of your Vornado fan.