Secop HMK95AA Compressor Technical Data
Model: HMK95AA
Designation: 220-240V/50Hz 1~
Sales Code: 15853800
Single Pack Details
Single Pack Code: 195B4542
Position | Title | Code | Quantity |
---|---|---|---|
1 | Compressor HMK95AA | 15853800 | 1 |
2 | Screw for cable clamp | 10636000 | 1 |
3 | Screw for cable clamp | 10636200 | 1 |
4 | Cover | 10636401 | 1 |
5 | Rubber grommet 16.5mm | 10639900 | 4 |
6 | Sleeve | 10640100 | 4 |
7 | Earth screw | 10641201 | 1 |
8 | Cable clamp | 11341000 | 1 |
9 | Terminal board 4.8mm | 15163500 | 1 |
Compressor Design
- Oil type: Mineral
- Oil viscosity: 5cST
- Oil quantity: 162cm³ / 5.5fl.oz
- Refr. charge - tech. limit: 150g / 5.3oz
- Free gas volume comp.: 1500cm³ / 50.7fl.oz
- Weight: 7.9kg / 17.4lbs
- Motor protection: external
- Winding resistance main: 21.1Ω (at 25°C)
- Winding resistance aux: 19.1Ω (at 25°C)
- Max. winding temp.: 130°C / 266°F
- Max. discharge temp.: 130°C / 266°F
Compressor Dimensions
Housing
- A Height: 174mm / 6.85in
- B Height: 167mm / 6.57in
- C Length shell: 194mm / 7.64in
- D Length w. cover: 238mm / 9.37in
- E Width: 151mm / 5.94in
Connectors
Suction | Discharge | Process | ||
---|---|---|---|---|
X | Y | Z | ||
Diameter (inside, outside) | øi 6.16-6.24 / øi 0.24-0.25 | øi 5.1-5.2 / øi 0.2-0.2 | øi 6.11-6.29 / øi 0.24-0.25 | |
Material | copper | copper | copper | |
Horizontal angle | +2° | 54° | 35° | 45° |
Vertical angle | +2° | 35° | 40° | 35° |
Position I/h/w [mm] | 120/92/57 | 112/106/81 | -86/94/72 | |
[in] | 4.7/3.6/2.2 | 4.4/4.2/3.2 | -3.4/3.7/2.8 | |
Straight tube I. [mm] | 14 | 14 | 14 | |
[in] | 0.5 | 0.5 | 0.5 |
General Configurations with HMK95AA
Conf. 1
- Motor configuration: RSIR
- Power supply (nominal): 220-240V/50Hz
- Number of phases: 1
- Voltage range: 187-264V
- Approvals: VDE
- Starting torque: LST
- Note: Various options of connectors are possible - please contact SECOP-Sales.
Applications with HMK95AA
Conf. 1
- Refrigerant: R600a
- Application: LBP
- System cooling: static
- Hot gas defrost: -/-
- Long interval pull down: -/-
Electrical Data - Configurations with HMK95AA
Conf. 1
- Starting device type: PTC
- Run capacitor: -/-
- Start capacitor: -/-
- LRA (locked rotor amps / 4s/ U(N)): 4.6A
- RLA (rated load amps / 1s/ U(N)): 1A
- Cut in current (U(N)): 10.1A
Ambient/Machine Room Temperatures
- Ambient temperature range: 10-43°C / 50-110°F
- Machine room temperature range: 10-48°C / 50-119°F
- Compressor cooling: static
Operation Pressure Range
Condensing pressure (saturation temperature):
Evaporation pressure (saturation temperature):
Return gas temp.:
Liquid temp.:
Ref. mass flow:
Cooling capacity:
COP:
EER:
P1:
Current consumption:
[A]:
[kg/h]:
[°C]
[°F]
[W]
[Btu/h]
[kcal/h]
[W/W]
[Btu/Wh]
[kcal/Wh]
[W]
[A]
[kg/h]
-23
-10
166.9
570
143.6
1.53
5.22
1.31
109.3
0.76
1.79
ASHRAE LBP
-25
-13
125.0
427
107.6
1.19
4.07
1.02
105.0
0.74
1.63
cecomaf LBP
-35
-31
72.9
249
62.7
0.99
3.38
0.85
73.7
0.63
0.89
EN12900 LBP
-23
-10
134.4
459
115.7
1.28
4.38
1.10
104.7
0.75
1.96
ARI540 LBP
-23
-10
175.0
598
150.6
1.77
6.04
1.52
99.0
0.74
1.88
AHAM LBP
-35
-31
72.5
248
62.4
0.96
3.29
0.83
75.4
0.62
0.86
opt
Performance Tables
pe | pc | Cooling capacity | COP | EER | P1 | m | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
[°C] | [°F] | [W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | [A] | [kg/h] | |
cond. pressure pc= 45/113 | -35 | -31 | 72.5 | 248 | 62.4 | 0.96 | 3.29 | 0.83 | 75.4 | 0.62 | 0.86 |
-30 | -22 | 104.4 | 357 | 89.9 | 1.21 | 4.12 | 1.04 | 86.5 | 0.67 | 1.24 | |
return gas temp. RGT=32/90 | -25 | -13 | 141.8 | 484 | 122.1 | 1.45 | 4.94 | 1.25 | 98.0 | 0.73 | 1.69 |
-23 | -10 | 155.8 | 532 | 134.1 | 1.53 | 5.22 | 1.31 | 102.0 | 0.75 | 1.86 | |
liquid temp. Tliq= 45/113 | -20 | -4 | 184.7 | 631 | 158.9 | 1.68 | 5.75 | 1.45 | 109.7 | 0.78 | 2.20 |
-15 | 5 | 233.0 | 796 | 200.5 | 1.92 | 6.56 | 1.65 | 121.2 | 0.84 | 2.78 | |
-5 | 23 | 345.9 | 1181 | 297.7 | 2.41 | 8.23 | 2.08 | 143.5 | 0.96 | 4.15 | |
cond. pressure pc= 55/131 | -35 | -31 | 66.7 | 228 | 57.4 | 0.85 | 2.89 | 0.73 | 78.9 | 0.60 | 0.87 |
-30 | -22 | 92.9 | 317 | 79.9 | 1.02 | 3.47 | 0.87 | 91.4 | 0.67 | 1.21 | |
return gas temp. RGT=32/90 | -25 | -13 | 125.0 | 427 | 107.6 | 1.19 | 4.07 | 1.02 | 105.0 | 0.74 | 1.63 |
-23 | -10 | 137.3 | 469 | 118.1 | 1.25 | 4.27 | 1.08 | 109.8 | 0.77 | 1.79 | |
liquid temp. Tliq= 55/131 | -20 | -4 | 163.0 | 557 | 140.3 | 1.36 | 4.66 | 1.17 | 119.5 | 0.81 | 2.13 |
-15 | 5 | 207.0 | 707 | 178.2 | 1.54 | 5.25 | 1.32 | 134.8 | 0.89 | 2.71 | |
-5 | 23 | 312.6 | 1067 | 269.0 | 1.88 | 6.41 | 1.61 | 166.6 | 1.04 | 4.11 |
Electrical Accessories / Wiring Diagram
A diagram shows the electrical connections for the RSIR compressor, including the terminal board, cover, cable clamp, and thermostat. It also indicates the 5th contact (optional) and the power supply connections.
Service/Repair – R600a
Visuals illustrate the proper handling and connection of components for R600a refrigerant, emphasizing safety precautions with warning symbols (crossed-out tools, exclamation mark) and correct procedures (check mark).
Compressor Fixation
Details on compressor fixation methods are provided, including a baseplate diagram with dimensions and mounting hole specifications. It also shows details for 'Bolt joint' and 'Snap-on' mounting accessories, along with their respective order codes.
Application Notes
- Provision for PE Grounding is located at the PE Stamp on the compressor.
- Housing with dip-tray fixture (omega bracket).
- Various options of connectors are possible - please contact SECOP-Sales.