Secop NL7F Compressor - Technical Data
Model: NL7F
Designation: 220-240V/50Hz 1~
Sales Code: 105G6706
Single Pack Details
Codice Imballo Singolo: 195B4206
Posizione | Titolo | Codice | Quantità |
---|---|---|---|
1 | Compressor NL7F | 105G6706 | 1 |
2 | PTC starting device (220V, 25Ohm, 6.3mm) | 103N0011 | 1 |
3 | Protection screen for PTC | 103N0476 | 1 |
4 | Cord relief | 103N1010 | 1 |
5 | Cover | 103N2010 | 1 |
6 | Bolt joint for one compressor | M6 | ø16mm | 118-1917 | 1 |
Compressor Design and Specifications
Oil type: Polyolester
Oil viscosity: 19,2 cST
Oil quantity: 265cm³ / 9fl.oz
Refrigerant: R134a
Displacement: 7,27cm³ / 0,44 cu.in
Weight: 9,6kg / 21,2lbs
Motor protection: Internal
Winding resistance main: 13,3Ω (at 25°C)
Winding resistance aux: 14,1Ω (at 25°C)
Max. winding temp.: 125°C / 257°F
Max. discharge temp.: 130°C / 266°F
Compressor dimensions:
- Height: 189,5mm / 7,46in
- Height (shell): 183,5mm / 7,22in
- Length (shell): 205mm / 8,07in
- Length (with cover): 254mm / 10in
- Width: 166mm / 6,54in
Connectors:
Suction (X) | Discharge (Y) | Process (Z) | |
---|---|---|---|
Diameter (inside, outside): | øi 6,11-6,29 / øi 0,24-0,25 | øi 5,12-5,22 / øi 0,2-0,21 | øi 6,11-6,29 / øi 0,24-0,25 |
Material: | copper | copper | copper |
Horizontal angle: | +2° | 0° | 0° |
Vertical angle: | +2° | 15° | 155° |
Position l/h/w: | 126/76/78 mm (4,9/3/3,1 in) | 133/103/54 mm (5,2/4/2,1 in) | -107/94/72 mm (-4,2/3,7/2,8 in) |
Straight tube l.: | 12 mm (0,5 in) | 12 mm (0,5 in) | 12 mm (0,5 in) |
Configurations
Conf. 1 (CSIR)
Motorconfiguration: CSIR
Power supply: 220-240V/50Hz
Number of phases: 1
Voltage range: 198-254V
Approvals: VDE, EAC
Starting torque: HST
Application: LBP
System cooling: static
Starting device type: relay
Start capacitor: 80μF
LRA (locked rotor amps / 4s): 5,9A
RLA (rated load amps / 1s): 1,2A
Cut in current: 10,4A
Conf. 2 (RSIR)
Motorconfiguration: RSIR
Power supply: 220-240V/50Hz
Number of phases: 1
Voltage range: 198-254V
Approvals: VDE, EAC
Starting torque: LST
Application: LBP
System cooling: static
Starting device type: PTC
Start capacitor: -/-
LRA (locked rotor amps / 4s): 5,9A
RLA (rated load amps / 1s): 1,2A
Cut in current: 10,4A
Ambient Temperatures / System Cooling
Ambient temperature min.: 10°C / 50°F
Ambient temperature max.: 38°C / 101°F
T ambient | LBP | MBP | HBP |
---|---|---|---|
32°C / 90°F | static | n/a | n/a |
38°C / 100°F | static | n/a | n/a |
43°C / 110°F | n/a | n/a | n/a |
Operation Pressure Range
Condensing pressure (sat. temp.):
Condensing pressure [bara]:
Evaporation pressure (sat. temp.):
Evaporation pressure [bara]:
(Diagrams showing condensing and evaporation pressure ranges are present but not included in this text-based format.)
Optimization + Standard Conditions
Refrigerant: R134a, 220V/50Hz, CSIR, static, VDE, EAC
pe [°C/°F] | pc [°C/°F] | RGT [°C/°F] | Tliq [°C/°F] | Cooling capacity | COP | EER | Power consumption | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | P1 [W] | I [A] | m [kg/h] | |||||
-23,3 / -10 | 54,4 / 130 | 32,2 / 90 | 32,2 / 90 | 186,1 | 636 | 160,2 | 1,21 | 4,12 | 1,04 | 154,2 | 1,04 | 3,61 | |
-25 / -13 | 55 / 131 | 32 / 89,6 | 55 / 131 | 136,1 | 465 | 117,1 | 0,93 | 3,19 | 0,80 | 145,9 | 1,02 | 3,25 | |
-35 / -31 | 40 / 104 | 20 / 68 | 40 / 104 | 89,5 | 306 | 77,0 | 0,86 | 2,94 | 0,74 | 104,0 | 0,97 | 1,96 | |
-23,3 / -10 | 48,9 / 120 | 4,44 / 40 | 48,9 / 120 | 153,8 | 525 | 132,3 | 1,02 | 3,50 | 0,88 | 150,1 | 1,02 | 4,06 | |
-23,3 / -10 | 40,6 / 105 | 32,2 / 90 | 32,2 / 90 | 209,5 | 716 | 180,3 | 1,45 | 4,95 | 1,25 | 144,7 | 1,01 | 4,07 | |
-35 / -31 | 45 / 113 | 32 / 89,6 | 45 / 113 | 84,1 | 287 | 72,4 | 0,83 | 2,84 | 0,72 | 100,9 | 0,95 | 1,81 |
Performance Tables (R134a, 220V/50Hz, CSIR, static, VDE, EAC):
pe [°C/°F] | pc [°C/°F] | RGT [°C/°F] | Tliq [°C/°F] | Cooling capacity | COP | EER | Power consumption | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | P1 [W] | I [A] | m [kg/h] | |||||
-35 / -31 | 45 / 113 | 32 / 90 | 32 / 90 | 84,1 | 287 | 72,4 | 0,83 | 2,84 | 0,72 | 100,9 | 0,95 | 1,81 | |
-30 / -22 | 49,5 / 113 | 32 / 90 | 32 / 90 | 119,5 | 408 | 102,8 | 1,00 | 3,41 | 0,86 | 119,8 | 0,96 | 2,58 | |
-25 / -13 | 55 / 131 | 32 / 89,6 | 32 / 89,6 | 163,9 | 560 | 141,0 | 1,17 | 3,99 | 1,01 | 140,1 | 1,00 | 3,55 | |
-23,3 / -10 | 54,4 / 130 | 32 / 90 | 32 / 90 | 181,0 | 618 | 155,8 | 1,23 | 4,19 | 1,06 | 147,4 | 1,01 | 3,93 | |
-20 / -4 | 57,7 / 136 | 32 / 90 | 32 / 90 | 217,3 | 742 | 187,0 | 1,34 | 4,58 | 1,15 | 162,1 | 1,05 | 4,72 | |
-15 / 5 | 62,8 / 145 | 32 / 90 | 32 / 90 | 280,0 | 956 | 241,0 | 1,51 | 5,14 | 1,30 | 185,9 | 1,13 | 6,10 | |
-10 / 14 | 67,9 / 158 | 32 / 90 | 32 / 90 | 352,1 | 1202 | 303,0 | 1,66 | 5,67 | 1,43 | 212,0 | 1,24 | 7,70 |
Performance Tables (R134a, 220V/50Hz, RSIR, static, VDE, EAC):
pe [°C/°F] | pc [°C/°F] | RGT [°C/°F] | Tliq [°C/°F] | Cooling capacity | COP | EER | Power consumption | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | P1 [W] | I [A] | m [kg/h] | |||||
-35 / -31 | 45 / 113 | 32 / 90 | 32 / 90 | 70,9 | 242 | 61,1 | 0,73 | 2,50 | 0,63 | 97,1 | 0,92 | 1,69 | |
-30 / -22 | 50 / 122 | 30 / 86 | 30 / 86 | 99,0 | 338 | 85,2 | 0,82 | 2,80 | 0,71 | 120,8 | 0,96 | 2,36 | |
-25 / -13 | 55 / 131 | 30 / 86 | 30 / 86 | 136,1 | 465 | 117,1 | 0,93 | 3,19 | 0,80 | 145,9 | 1,02 | 3,25 | |
-23 / -10 | 54 / 129 | 32 / 90 | 32 / 90 | 150,8 | 515 | 129,8 | 0,97 | 3,33 | 0,84 | 154,7 | 1,04 | 3,61 | |
-20 / -4 | 57 / 135 | 32 / 90 | 32 / 90 | 182,4 | 623 | 156,9 | 1,06 | 3,61 | 0,91 | 172,6 | 1,10 | 4,37 | |
-15 / 5 | 62 / 144 | 32 / 90 | 32 / 90 | 237,9 | 813 | 204,8 | 1,18 | 4,04 | 1,02 | 201,2 | 1,20 | 5,73 | |
-10 / 14 | 67 / 157 | 32 / 90 | 32 / 90 | 303,0 | 1035 | 260,8 | 1,31 | 4,46 | 1,12 | 231,9 | 1,33 | 7,33 |
Electrical Accessories / Wiring Diagram
(Diagrams illustrating electrical accessories and wiring for CSIR and RSIR configurations are present but not included in this text-based format.)
Components (CSIR):
- a2 relay: 117U6000
- start capacitor (80μF): 117U5015
- b plastic cover: 103N2010
- d cord relief: 103N1010
- g protection screen for PTC: 103N0476
Alternative components (CSIR):
- b plastic cover: 103N2011
Components (RSIR):
- a1 PTC starter (220V, 25Ohm, 4.8mm): 103N0018
- b plastic cover: 103N2010
- d cord relief: 103N1010
- g protection screen for PTC: 103N0476
Alternative components (RSIR):
- a1 PTC starter (220V, 25Ohm, 6.3mm): 103N0011
- b plastic cover: 103N2011
- d cord relief: 103N1010
- g protection screen for PTC: 103N0476
Service/Repair Information
Warning: Handling of R600a and R290 refrigerants requires specific safety precautions. Refer to relevant safety data sheets and guidelines.
Brazing on Suction Connectors (Direct Intake):
Maximum temperature at socket: 150°C / 302°F.
Brazing solder: phosphor (LP7) or silver.
Refer to Product Bulletin: Brazing on Suction Connectors (Compressors with Direct Suction Intake).