Broan-NuTone Range Hood Installation, Use and Care Manual

Series: BKDD1, BKDF1, BKSA2, BKSM1, BKSR1, CKSL1, NKDF1, NKSA2 and NKSH1

Serial number: 99045655-001K

Safety

⚠️ WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

⚠️ WARNING

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE:

  1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE AND CALL THE FIRE DEPARTMENT.
  2. NEVER PICK UP A FLAMING PAN -- You may be burned.
  3. DO NOT USE WATER, including wet dishcloths or towels -- This could cause a violent steam explosion.
  4. Use an extinguisher ONLY if:
    • You own a Class ABC extinguisher and you know how to operate it.
    • The fire is small and contained in the area where it started.
    • The fire department has been called.
    • You can fight the fire with your back to an exit.

* Based on "Kitchen Fire Safety Tips" published by NFPA.

⚠️ CAUTION

Operation

Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and fresher. Operate the hood as follows:

BKSA2 AND NKSA2 SERIES

BLOWER SWITCH

LIGHT SWITCH

BKSR1 AND NKSH1 SERIES

BLOWER SWITCH

LIGHT SWITCH

BKSM1 AND CKSL1 SERIES

ON/OFF BLOWER PUSH BUTTON: When blower is OFF, push this button to turn ON the blower at the last selected speed. Push this button again to turn OFF the blower. NOTE: If there is no speed selected (all blower speed push buttons up), the blower will not turn ON. In that case, press on the desired speed level push button to activate the blower.

BLOWER SPEED LEVEL PUSH BUTTONS: When blower is ON, change the blower speed by pressing the push button corresponding to the desired speed: one line for LOW, two lines for MEDIUM and three lines for HIGH speed.

ON/OFF LIGHT PUSH BUTTON: When lights are OFF, push once on this button to turn ON the lights at the last selected setting. Push this button again to turn OFF the lights.

LIGHT INTENSITY LEVELS PUSH BUTTON: Push this button to change the light intensity (HIGH or LOW).

BKDD1, BKDF1 AND NKDF1 SERIES

BLOWER BUTTON: When blower is OFF, press this button to turn ON the blower at the last saved speed. If there was no speed saved, the blower will be set on LOW speed. NOTE: When LOW speed is activated from OFF, the blower starts on MEDIUM speed for a very short lapse of time, and then resume to LOW speed. To change the blower speed, press on this button again until the desired speed is reached (from LOW to MEDIUM to HIGH speed to OFF). Each time a blower speed is activated, a beep is heard and LED indicators light up to show the corresponding speed chosen (lower LED for LOW speed, lower and center LEDs for MEDIUM speed and all LEDs for HIGH speed). When blower is on (no matter the speed level), press and hold this button until the beep sound ends; this will turn off the blower and save this blower speed to memory.

LIGHT BUTTON: When lights are OFF, press once on this button to turn ON the lights at the last saved setting. If there was no light setting saved, the lights will be set on LOW intensity. Press another time to set the lights on HIGH intensity. Pressing another time after the HIGH setting will turn OFF the lights. Each time the lights are turned ON, a beep is heard and LED indicators light up to show the corresponding intensity chosen (lower LED for LOW and both LEDs for HIGH). When lights are on (no matter the lighting level), press and hold this button until the beep sound ends; this will turn off the lights and save the chosen light intensity.

The LED modules included with this hood are the latest in LED cooktop illumination technology specially designed to operate in the elevated temperatures of cooking - offering bright lighting and lasting up to 25 times as long as a standard bulb and greater reliability than typical replacement LED bulbs.

FILTER CLEANING REMINDER: When it is time to clean the hood and filters (refer to Cleaning and Maintenance on page 7), the 3 blower button LED indicators will flash slowly for 30 seconds after turning the blower OFF. This will happen every time the blower is turned OFF until the filter cleaning reminder has been reset. Once the cleaning is done, reset the filter cleaning reminder indicators by pressing on blower button for 3 seconds during the 30 seconds the 3 blower button LED indicators flash slowly.

Cleaning and Maintenance

Proper maintenance of the Range Hood will assure proper performance of the unit.

MOTOR

The motor is permanently lubricated and never needs oiling. If the motor bearings make excessive or unusual noise, replace the motor with the exact service motor. The fan blade should also be replaced.

GREASE FILTER(S)

The grease filter(s) should be cleaned frequently. Use a warm dishwashing detergent solution. Clean all-metal filters using a non-phosphate detergent. Discoloration of the filters may occur if using phosphate detergents, or as a result of local water conditions - but this will not affect filter performance. This discoloration is not covered by the warranty.

NON-DUCTED RECIRCULATION FILTER(S)

The non-ducted recirculation filter(s) should be changed every 3 to 6 months. Replace more often if your cooking style generates extra grease, such as frying and wok cooking. Refer to installation instructions included with non-ducted recirculation filter(s).

FAN BLADE

The fan blade should be cleaned frequently. Use a clean cloth soaked with warm detergent solution.

STAINLESS STEEL CLEANING

Do:

Don't:

Avoid when choosing a detergent:

PAINTED FINISH CLEANING:

Clean with warm water and mild detergent only. If discoloration occurs, use a finish polish such as automotive polish. (DO NOT use rough abrasive cleaner or porcelain cleaner.)

Installation

For ADA compliance installation guidelines, please type the model number into our website: www.Broan-NuTone.com.

Recommended Tools and Accessories for Installation

Install Ductwork (Ducted Installations Only)

Follow these steps for installing ductwork:

  1. Determine whether the hood will discharge vertically (3-1/4" x 10" or 7" round), or horizontally (3-1/4" x 10" only).
  2. Decide where the ductwork will run between the hood and the outdoors.
  3. Choose a straight, short duct run to allow the hood to perform most efficiently. Long duct runs, elbows and transitions will reduce the performance of the hood. Use as few of them as possible. When possible, use at least 2 foot straight runs before any turns. Larger ductwork may be required for best performance with longer duct runs.
  4. Install wall cap or roof cap (sold separately); ensure there is no leak in house insulation. Connect metal ductwork to cap and work back towards the hood location. Use 2" metal foil duct tape to seal the joints between ductwork sections.

NOTE: To use 6" round ducting, install a 3-1/4" x 10" to 6" round transition (not included). The performances may be affected.

Contents

Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer.

Make sure that the following items are included:

BKDF1 and NKDF1 Series

Template Description: The included template is used for marking ducting and electrical access holes. It is designed to provide clearance and does not need to be the exact size of the ducting. For framed cabinets, the template can be folded along a graduated scale. Markings indicate locations for 7" round ducting or rectangular ducting (3-1/4" x 10" or 3-1/4" x 14"). Electrical access hole center locations are marked as A (single blower hood) and B (double blower hood). The template should be placed with a specific edge against the back wall or cabinet bottom.

Included Parts (General):

* FIND EZ1 BRACKETS ATTACHED INSIDE OF HOOD

** FIND PARTS BAG BEHIND THE DAMPER ASSEMBLY INSIDE OF HOOD

BKSR1 and NKSH1 Series

BKDD1 Series

BKDF1 Series

BKSA2 and NKSA2 Series

BKDF130SSK

Prepare the Hood

NOTE: Since this manual covers many range hood models, some details in the following illustrations may slightly differ from your unit.

  1. If present, remove all protective polyfilm from the hood and/or parts.
  2. Using the finger cup or tab, remove the grease filters from the hood by pushing down and tilting filter out.
  3. BKDF130SSK only: Remove the non-ducted filters and the power cord from inside the hood. Remove the EZ1 brackets from inside the hood by cutting off the tie wrap (no EZ1 brackets in BKSA2 and NKSA2 Series). Remove both screws holding damper assembly to hood. Remove parts bag (captured behind the damper assembly). Remove damper assembly from inside the hood and keep the screws for further use.
  4. Remove the wiring cover by sliding it out from the hood and set it aside.
  5. BKDF130SSK only: Remove 7" Round Duct Plate from top/back of hood. Keep the screws for further use. All other range hood models: Remove 2 screws from top of hood. Keep the screws for further use.
  6. Remove Electrical Power Cable Knockout from top (vertical wiring) or back (horizontal wiring) of hood. Install an appropriate strain relief, 1/2" diameter (not included).
  7. NON-DUCTED INSTALLATION ONLY: Remove 3 screws retaining the recirculation cover plate to the hood. Discard this plate with its screws.
  8. DUCTED INSTALLATION ONLY: Remove 3-1/4" x 10" vertical, 3-1/4" x 10" horizontal, or 7-inch round knockout plate as appropriate for your ducting method.
  9. Attach 3-1/4" x 10" Damper Assembly on top OR back of hood (if using 3-1/4" x 10" duct) or 7" Round Duct Plate (if using 7-inch round duct) over the knockout opening. When installed, the 3-1/4" x 10" damper assembly must open freely.

Diagram Description (Damper Assembly): Figure 2A shows the 3-1/4" x 10" Damper Assembly and screws. Figure 2B illustrates the correct orientation of the damper flap pivot when attached to the top/back edge of the hood, ensuring it opens correctly. The damper flap pivot should be positioned on the back of the hood.

Diagram Description (7" Round Duct Plate): Figure 3 shows the 7" Round Duct Plate and screws. This plate is used for 7-inch round ducting installations.

NOTE: To accommodate off-center ductwork, the 7" round duct plate can be installed up to 1/2" on either side of the hood center.

TIP: Insert a small length of duct over the 3-1/4" x 10" damper assembly (for rectangular ducting) or 7" round (for round ducting) and seal the joint using aluminum foil duct tape to ease connection with the house ductwork.

Prepare the Hood Location

NOTE: Before starting installation, read all the steps of these instructions.

Use the illustration below to identify your kitchen cabinet type.

Cabinet Types: FRAMED CABINET, FRAMELESS CABINET

This manual covers 2 kinds of installation: the standard (without EZ1 brackets) and the EZ1 one-person installation system (using included template and brackets). Please note that the EZ1 one-person installation system is not available for the BKSA2 and NKSA2 Series. However, all Series range hoods can be installed in the standard way. For the standard installation, go to page 20.

EZ1 one-person installation system

EZ1 installation is designed for use with kitchen cabinets that have the same width designation as the range hood width. If the cabinet is greater than 1/2" wider than the range hood width, please use the standard installation method.

  1. Use the proper template for vertical OR horizontal discharge (included) for placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole, only cut the hole for electrical wiring. If replacing a hood and plan to use the existing duct and electrical, steps 2 to 5 may not be necessary. If so, skip to step 6.
  2. Measure and mark the hood center line on cabinet bottom.
  3. Align the center line on template with the hood center line marked on the bottom of the cabinet, placing the edge (where indicated) of the template against back wall. When using with framed cabinet for vertical exhaust installation, fold over rear edge of template equal to the depth of the cabinet frame at the wall (use graduations on template, C locations on template). Tape the template in place. NOTE: When facing the installation, A and B (on template) must be at right.
  4. Drill a 1/8" dia. pilot hole for house wiring, at A location on template.
  5. Use a sharp pencil or 1/8" drill bit to mark the locations for the appropriate duct access holes (16 locations for 7" round duct, or 4 corner locations for rectangular duct). Remove the template.
  6. Draw the border for the exhaust ducting by linking its marks (16 for round duct and 4 for rectangular duct), then cut the opening in the cabinet bottom (vertical exhaust) or in the wall (horizontal exhaust). Drill the house wiring hole by using a 1-1/4" hole saw centered with the pilot hole previously made in step 4.
  7. Install the proper installation brackets according to the type of cabinet (framed or frameless). See below.

Framed Cabinet Installation: Refer to the marking on the brackets to determine the correct installation side and orientation. Mate the corresponding bracket to the cabinet side frame, while placing the rear end of the bracket against the wall. Mark 3 holes (there are 6 holes but only 3 are necessary). Remove the bracket. Using a 7/64" drill bit, drill 3 holes where marked. Assemble the bracket to the side frame using a Phillips screwdriver and 3 provided no. 8 x 5/8" wood screws. Repeat for the other side frame.

Frameless Cabinet Installation: Refer to the marking on brackets to determine the correct installation side and orientation. Align the corresponding bracket to the cabinet side, while placing the rear end of the bracket against the wall. Draw a line on the outer edge of the bracket. Slide the bracket towards the center of the cabinet and align the side edge to the marked line, keeping the rear end edge leaning on the wall. Mark 3 holes. Remove the bracket. Using a 7/64" drill bit, drill 3 holes where marked. Assemble the bracket to the cabinet bottom using a Phillips screwdriver and 3 provided countersunk wood screws. Repeat for the other cabinet side.

Install the Hood (EZ1 Bracket)

NOTE: The following procedure applies to both framed or frameless cabinet installations.

  1. Run house power cable between service panel and hood location.
  2. There are 2 pairs of recessed holes on each side of the top of the hood (on rear: A and B, on front C and D); these holes allow the range hood to hang on the brackets (previously installed).
  3. HORIZONTAL EXHAUST INSTALLATION ONLY: Temporarily hang the hood on the brackets using its 2 recessed REAR HOLES (A and B). While holding the hood, run the house power cable into the hood through the strain relief previously installed in step 6 on page 13.
  4. Unhook the rear holes from the brackets and hang the hood using its 2 recessed FRONT HOLES (C and D). While holding the hood, attach the power cable to the hood using the strain relief.
  5. VERTICAL EXHAUST INSTALLATION AND NON-DUCTED INSTALLATION ONLY: Hang the hood on the brackets using the 2 recessed FRONT HOLES (C and D). While holding the hood, run the house power cable into the hood through the strain relief previously installed in step 6 on page 13. Attach power cable to the hood.
  6. DUCTED INSTALLATION ONLY: Connect the ductwork to the hood and use metal foil duct tape to make joints secure and air-tight. Make sure the damper assembly (or round duct plate) enters the ductwork and that the damper opens and closes freely.
  7. For framed cabinet, secure the hood to the EZ1 brackets using 4 no. 8-18 x 1/2" metal screws (included in parts bag). Insert 2 screws per side, in the slots.
  8. For frameless cabinet, secure the hood to the cabinet using 4 no. 8 x 5/8" round head wood screws (included in parts bag). Insert 2 screws per side, in the slots.

Standard Installation (without EZ1 brackets)

  1. Use the proper diagram below for placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole, only cut the hole for electrical wiring.
  2. Install part-way four (4) ROUND HEAD no. 8 x 5/8" mounting screws into shims/cabinet, according to the proper diagram above. (Mounting screws are included in parts bag, but wood shims and shim mounting screws are not included).

Install the Hood (Standard Installation)

  1. Run house power cable between service panel and hood location. Run the house power cable into the hood through the strain relief previously installed in step 6 on page 13.
  2. Hang hood from (4) mounting screws previously installed. Slide hood back towards wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood. Tighten screws securely. Attach power cable to the hood using the strain relief.
  3. DUCTED INSTALLATION ONLY: Connect ductwork to hood and use metal foil duct tape to make joints secure and air-tight. Make sure the damper assembly (or round duct plate) enters the ductwork and that the damper opens and closes freely.

Connect the Wiring

⚠️ WARNING

Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally.

NOTE: For BKDF130SSK range hood, the included cord connection kit can be used to perform the wiring. Refer to instructions packed with the cord connection kit.

NOTE: The following procedure applies to all models.

  1. Connect House Power Cable to range hood wiring: BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw.
  2. Reinstall wiring cover and attach it to the hood using its retaining screw.

⚠️ CAUTION

Ensure both tabs on inner top of hood are engaged in their corresponding slots in wiring cover. Also, take care not to pinch wires while reinstalling wiring cover.

Wiring Diagram Color Codes:

Light Bulbs

(BKSA2, BKSM1, BKSR1, CKSL1, NKSA2 and NKSH1 Series only)

The BKSA2, BKSM1, BKSR1, CKSL1, NKSA2 and NKSH1 Series range hoods require two shielded Halogen Bulbs (120 V, 50 W max., MR16 or PAR16 with GU10 base) (included only with BKSM1, BKSR1, CKSL1 and NKSH1 Series range hoods).

⚠️ WARNING

Do not touch lamps during or soon after operation. Burns may occur. In order to prevent the risk of personal injury, only install shielded halogen lamps. Also, never install a cool beam, a dichroic lamp, a lamp not suitable for use in recessed luminaires or identified for use in enclosed fixtures.

Bulb Installation:

  1. Align the bulb leads with the small indentations located on the border of the lamp location on hood, then install the bulbs by placing the bulb leads into their grooves in the socket.
  2. Gently push upwards and turn clockwise until secure.

NOTE: The Suction Cup Tool (included with hood) can be used to install and remove light bulbs. Press suction cup tool on bulb and rotate counterclockwise to remove bulb or clockwise to install bulb.

⚠️ CAUTION

Most GU10 LED replacement bulbs commonly found in the market are not designed for use in a cooking environment and might not perform as advertised. Their usage with this product is not recommended.

Install the Filter(s)

Ducted Installation Only: Re-install grease filter(s) removed in step 2 on page 12, under "Prepare the Hood".

Non-ducted Installation Only: According to your range hood model, purchase one or two non-ducted filters from your local distributor or retailer (see product specification label for filter type). NOTE: The non-ducted filters are included with BKDF130SSK range hood. Attach the non-ducted filter(s) following instructions packed with the non-ducted filter(s).

Wiring Diagrams

Wiring diagrams are provided for different series to illustrate electrical connections.

BKDD1, BKDF1 AND NKDF1 SERIES

Control Board Connections: J1 (Line, Neutral, Ground), J2 (Motor), J4 (LED), J6 (Override), J10 (Interface).

Wiring Color Code: BLACK (BK), BLUE (BL), BROWN (BN), BROWN/WHITE (BN/W), GREEN/YELLOW (G/Y), ORANGE (O), RED (R), WHITE (W).

Fan Motor Connections: Pins 1-6 are labeled with corresponding wire colors (e.g., 1-W, 2-G/Y, 3-BK, 4-O, 5-R, 6-BN/W).

BKSM1 AND CKSL1 SERIES

Control Buttons: Motor On/Off, Motor Speeds (Low, Medium, High), Lights On/Off, Lights High/Low.

Wiring Color Code: BLACK (BK), BLUE (BL), BROWN (BN), BROWN/WHITE (BN/W), GREEN/YELLOW (G/Y), ORANGE (O), RED (R), WHITE (W), YELLOW (Y).

Fan Motor Connections: Pins 1-6 are labeled with corresponding wire colors (e.g., 1-W, 2-G/Y, 3-BK, 4-O, 5-R, 6-BN/W).

BKSA2, BKSR1, NKSA2 AND NKSH1 SERIES

Control Switches: Light Switch (Low, High), Motor Switch (Low, High).

Wiring Color Code: BLACK (BK), BLUE (BL), BROWN (BN), BROWN/WHITE (BN/W), GREEN/YELLOW (G/Y), ORANGE (O), RED (R), WHITE (W), YELLOW (Y).

Fan Motor Connections: Pins 1-6 are labeled with corresponding wire colors (e.g., 1-W, 2-G/Y, 3-BK, 4-O, 5-R, 6-BN/W).

Service Parts

Replacement parts are available from the manufacturer. Use genuine replacement parts only to ensure proper function and safety.

BKDD1 SERIES

KEY NO. PART NO. DESCRIPTION QUANTITY (30" STAINLESS) QUANTITY (30" WHITE)
1 S97020030 / S97020031 RECIRCULATION COVER PLATE, WHITE (INCLUDING SCREWS) / STAINLESS STEEL (INCLUDING SCREWS) 1 1
2 S97020534 3-1/4" X 10" DAMPER ASSEMBLY (INCLUDING SCREWS) 1 1
3 S97020409 BLOWER MOTOR (INCLUDING 4 SCREWS AND 1 CAPACITOR) 1 1
4 S97020407 FANPELLER (INCLUDING ITEM 5) 1 1
5 SR99420635 CLIP FOR FANPELLER 1 1
6 S99010431-002 GREASE FILTER - MICRO MESH - OBLONG - TYPE C3 (SET OF 2) 1 1
7 S97020444 LED MODULE (PAIR) 1 1
8 S97020445 TRANSFORMER 24 V 18 VA (WITH SCREWS) 1 1
9 S97020431 / S97020432 CAPTOUCH CONTROL LED, STAINLESS (WITH SCREWS) / WHITE (WITH SCREWS) 1 1
* S97020452 WIRE HARNESS 1 1
* S98011637 WIRING COVER 1 1
* S97020360 PARTS BAG INCLUDING: 4 METAL SCREWS NO. 8-18 X 1/2", 6 ROUND HEAD NO. 8 X 5/8" WOOD SCREWS, 6 NO. 8 X 1/2" COUNTERSUNK SCREWS 1 1
* S97020466 NON-DUCTED FILTER - TYPE XC (SET OF 2) (NON-DUCTED INSTALLATION ONLY) 1 1
* S99527587 NON-DUCTED FILTER CLIP KIT (INCLUDES 4 CLIPS) 1 1
* S97020470 EASY INSTALL KIT (INCLUDING HARDWARE) 1 1

BKDF1 SERIES

KEY NO. PART NO. DESCRIPTION QUANTITY (30" STAINLESS) QUANTITY (30" WHITE)
1 S97020030 / S97020031 RECIRCULATION COVER PLATE, WHITE (INCLUDING SCREWS) / STAINLESS STEEL (INCLUDING SCREWS) 1 1
2 S97020534 3-1/4" X 10" DAMPER ASSEMBLY (INCLUDING SCREWS) 1 1
3 S97020409 BLOWER MOTOR (INCLUDING 4 SCREWS AND 1 CAPACITOR) 1 1
4 S97020407 FANPELLER (INCLUDING ITEM 5) 1 1
5 SR99420635 CLIP FOR FANPELLER 1 1
6 S99010434-002 GREASE FILTER - MICRO MESH - TYPE C2 (SET OF 2) 1 1
7 S97020444 LED MODULE (PAIR) 1 1
8 S97020445 TRANSFORMER 24 V 18 VA (WITH SCREWS) 1 1
9 S97020431 / S97020432 CAPTOUCH CONTROL LED, STAINLESS (WITH SCREWS) / WHITE (WITH SCREWS) 1 1
* S97020452 WIRE HARNESS 1 1
* S98011637 WIRING COVER 1 1
* S97020360 PARTS BAG INCLUDING: 4 METAL SCREWS NO. 8-18 X 1/2", 6 ROUND HEAD NO. 8 X 5/8" WOOD SCREWS, 6 NO. 8 X 1/2" COUNTERSUNK SCREWS 1 1
* S97020466 NON-DUCTED FILTER - TYPE XC (SET OF 2) (NON-DUCTED INSTALLATION ONLY) 1 1
* S99527587 NON-DUCTED FILTER CLIP KIT (INCLUDES 4 CLIPS) 1 1
* S97020470 EASY INSTALL KIT (INCLUDING HARDWARE) 1 1
* SR680508 7'' ROUND DUCT PLATE (INCLUDING SCREWS) 1 1

NKDF1 SERIES

KEY NO. PART NO. DESCRIPTION QUANTITY (30" STAINLESS) QUANTITY (30" WHITE)
1 S97020030 / S97020031 RECIRCULATION COVER PLATE, WHITE (INCLUDING SCREWS) / STAINLESS STEEL (INCLUDING SCREWS) 1 1
2 S97020534 3-1/4" X 10" DAMPER ASSEMBLY (INCLUDING SCREWS) 1 1
3 S97020409 BLOWER MOTOR (INCLUDING 4 SCREWS AND 1 CAPACITOR) 1 1
4 S97020407 FANPELLER (INCLUDING ITEM 5) 1 1
5 SR99420635 CLIP FOR FANPELLER 1 1
6 S99010434-002 GREASE FILTER - MICRO MESH - TYPE C2 (SET OF 2) 1 1
7 S97020444 LED MODULE (PAIR) 1 1
8 S97020445 TRANSFORMER 24 V 18 VA (WITH SCREWS) 1 1
9 S97020431 / S97020432 CAPTOUCH CONTROL LED, STAINLESS (WITH SCREWS) / WHITE (WITH SCREWS) 1 1
* S97020452 WIRE HARNESS 1 1
* S98011637 WIRING COVER 1 1
* S97020360 PARTS BAG INCLUDING: 4 METAL SCREWS NO. 8-18 X 1/2", 6 ROUND HEAD NO. 8 X 5/8" WOOD SCREWS, 6 NO. 8 X 1/2" COUNTERSUNK SCREWS 1 1
* S97020466 NON-DUCTED FILTER - TYPE XC (SET OF 2) (NON-DUCTED INSTALLATION ONLY) 1 1
* S99527587 NON-DUCTED FILTER CLIP KIT (INCLUDES 4 CLIPS) 1 1
* S97020470 EASY INSTALL KIT (INCLUDING HARDWARE) 1 1

BKSM1 SERIES

KEY NO. PART NO. DESCRIPTION QUANTITY (30" STAINLESS) QUANTITY (30" WHITE)
1 S97020030 / S97020031 RECIRCULATION COVER PLATE, WHITE (INCLUDING SCREWS) / STAINLESS STEEL (INCLUDING SCREWS) 1 1
2 S97020534 3-1/4" X 10" DAMPER ASSEMBLY (INCLUDING SCREWS) 1 1
3 S97020409 BLOWER MOTOR (INCLUDING 4 SCREWS AND 1 CAPACITOR) 1 1
4 S97020407 FANPELLER (INCLUDING ITEM 5) 1 1
5 SR99420635 CLIP FOR FANPELLER 1 1
6 S99010434-002 GREASE FILTER - MICRO MESH - TYPE C2 (SET OF 2) 1 1
7 S97020427 MECHANICAL PUSH-BUTTON CONTROL (6 BUTTONS) 1 1
8 S97020450 WIRE HARNESS 1 1
* S98011637 WIRING COVER 1 1
* S97020292 PARTS BAG INCLUDING: 4 METAL SCREWS NO. 8-18 X 1/2", 6 ROUND HEAD NO. 8 X 5/8" WOOD SCREWS, 6 NO. 8 X 1/2" COUNTERSUNK SCREWS, 1 SUCTION CUP TOOL 1 1
* S97020466 NON-DUCTED FILTER - TYPE XC (SET OF 2) (NON-DUCTED INSTALLATION ONLY) 1 1
* S99527587 NON-DUCTED FILTER CLIP KIT (INCLUDES 4 CLIPS) 1 1
* S97020470 EASY INSTALL KIT (INCLUDING HARDWARE) 1 1
* SV05921 SHIELDED HALOGEN BULB 50 W, GU10 2 2

CKSL1 SERIES

KEY NO. PART NO. DESCRIPTION QUANTITY (30" STAINLESS)
1 S97020031 RECIRCULATION COVER PLATE, STAINLESS STEEL (INCLUDING SCREWS) 1
2 S97020534 3-1/4" X 10" DAMPER ASSEMBLY (INCLUDING SCREWS) 1
3 S97020408 BLOWER MOTOR (INCLUDING 4 SCREWS AND 1 CAPACITOR) 1
4 S97020407 FANPELLER (INCLUDING ITEM 5) 1
5 SR99420635 CLIP FOR FANPELLER 1
6 S99010434-002 GREASE FILTER - MICRO MESH - TYPE C2 (SET OF 2) 1
7 S97020427 MECHANICAL PUSH-BUTTON CONTROL (6 BUTTONS) 1
8 S97020450 WIRE HARNESS 1
* S98011637 WIRING COVER 1
* S97020292 PARTS BAG INCLUDING: 4 METAL SCREWS NO. 8-18 X 1/2", 6 ROUND HEAD NO. 8 X 5/8" WOOD SCREWS, 6 NO. 8 X 1/2" COUNTERSUNK SCREWS, 1 SUCTION CUP TOOL 1
* S97020466 NON-DUCTED FILTER - TYPE XC (SET OF 2) (NON-DUCTED INSTALLATION ONLY) 1
* S99527587 NON-DUCTED FILTER CLIP KIT (INCLUDES 4 CLIPS) 1
* S97020470 EASY INSTALL KIT (INCLUDING HARDWARE) 1
* SV05921 SHIELDED HALOGEN BULB 50 W, GU10 2

NKSH1 SERIES

KEY NO. PART NO. DESCRIPTION QUANTITY (30" STAINLESS) QUANTITY (30" WHITE) QUANTITY (30" BLACK)
1 S97020030 / S97020031 / S97020029 RECIRCULATION COVER PLATE, WHITE (INCLUDING SCREWS) / STAINLESS STEEL (INCLUDING SCREWS) / BLACK (INCLUDING SCREWS) 1 1 1
2 S97020534 3-1/4" X 10" DAMPER ASSEMBLY (INCLUDING SCREWS) 1 1 1
3 S97020408 BLOWER MOTOR (INCLUDING 4 SCREWS AND 1 CAPACITOR) 1 1 1
4 S97020407 FANPELLER (INCLUDING ITEM 5) 1 1 1
5 SR99420635 CLIP FOR FANPELLER 1 1 1
6 S99010434-002 GREASE FILTER - MICRO MESH - TYPE C2 (SET OF 2) 1 1 1
7 S97020422 / S97020421 / S97020420 ELONGATED ROCKER SWITCH, GREY (INCLUDING SCREWS) / WHITE (INCLUDING SCREWS) / BLACK (INCLUDING SCREWS) 1 1 1
8 S97020448 WIRE HARNESS 1 1 1
* S98011637 WIRING COVER 1 1 1
* S97020292 PARTS BAG INCLUDING: 4 METAL SCREWS NO. 8-18 X 1/2", 6 ROUND HEAD NO. 8 X 5/8" WOOD SCREWS, 6 NO. 8 X 1/2" COUNTERSUNK SCREWS, 1 SUCTION CUP TOOL 1 1 1
* S97020466 NON-DUCTED FILTER - TYPE XC (SET OF 2) (NON-DUCTED INSTALLATION ONLY) 1 1 1
* S99527587 NON-DUCTED FILTER CLIP KIT (INCLUDES 4 CLIPS) 1 1 1
* S97020470 EASY INSTALL KIT (INCLUDING HARDWARE) 1 1 1
* SV05921 SHIELDED HALOGEN BULB 50 W, GU10 2 2 2

BKSR1 SERIES

KEY NO. PART NO. DESCRIPTION QUANTITY (30" STAINLESS) QUANTITY (30" WHITE)
1 S97020030 / S97020031 RECIRCULATION COVER PLATE, WHITE (INCLUDING SCREWS) / STAINLESS STEEL (INCLUDING SCREWS) 1 1
2 S97020534 3-1/4" X 10" DAMPER ASSEMBLY (INCLUDING SCREWS) 1 1
3 S97020408 BLOWER MOTOR (INCLUDING 4 SCREWS AND 1 CAPACITOR) 1 1
4 S97020407 FANPELLER (INCLUDING ITEM 5) 1 1
5 SR99420635 CLIP FOR FANPELLER 1 1
6 S99010430-002 GREASE FILTER - OPEN MESH - TYPE C1 (SET OF 2) 1 1
7 S97020422 / S97020421 ELONGATED ROCKER SWITCH, GREY (INCLUDING SCREWS) / WHITE (INCLUDING SCREWS) 1 1
8 S97020448 WIRE HARNESS 1 1
* S98011637 WIRING COVER 1 1
* S97020292 PARTS BAG INCLUDING: 4 METAL SCREWS NO. 8-18 X 1/2", 6 ROUND HEAD NO. 8 X 5/8" WOOD SCREWS, 6 NO. 8 X 1/2" COUNTERSUNK SCREWS, 1 SUCTION CUP TOOL 1 1
* S97020466 NON-DUCTED FILTER - TYPE XC (SET OF 2) (NON-DUCTED INSTALLATION ONLY) 1 1
* S99527587 NON-DUCTED FILTER CLIP KIT (INCLUDES 4 CLIPS) 1 1
* S97020470 EASY INSTALL KIT (INCLUDING HARDWARE) 1 1
* SV05921 SHIELDED HALOGEN BULB 50 W, GU10 2 2

BKSA2 AND NKSA2 SERIES

KEY NO. PART NO. DESCRIPTION QUANTITY (30" STAINLESS)
1 S97020031 RECIRCULATION COVER PLATE, STAINLESS STEEL (INCLUDING SCREWS) 1
2 S97020534 3-1/4" X 10" DAMPER ASSEMBLY (INCLUDING SCREWS) 1
3 S97020408 BLOWER MOTOR (INCLUDING 4 SCREWS AND 1 CAPACITOR) 1
4 S97020407 FANPELLER (INCLUDING ITEM 5) 1
5 SR99420635 CLIP FOR FANPELLER 1
6 S99010436 GREASE FILTER - OPEN MESH - TYPE A0 1
7 S99030367 ROCKER SWITCH, GREY (SET OF 2) 1
8 S97020448 WIRE HARNESS 1
* S98011637 WIRING COVER 1
* S97018623 PARTS BAG INCLUDING: 5 ROUND HEAD NO. 8 X 5/8" WOOD SCREWS, 1 SUCTION CUP TOOL 1
* S97020464 NON-DUCTED FILTER - TYPE XA (1PC.) (NON-DUCTED INSTALLATION ONLY) 1
* S99527587 NON-DUCTED FILTER CLIP KIT (INCLUDES 4 CLIPS) 1
* SV05921 SHIELDED HALOGEN BULB 50 W, GU10 2

REPLACEMENT PARTS AND REPAIRS: In order to ensure your unit remains in good working condition, you must use Broan-NuTone LLC or Venmar Ventilation ULC genuine replacement parts only. Broan-NuTone LLC or Venmar Ventilation ULC genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety. Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit, which will result in premature failing. Broan-NuTone LLC and Venmar Ventilation ULC recommend to contact a certified service depot for all replacement parts and repairs.

Warranty

Limited Warranty

Warranty Period and Exclusions: Broan-NuTone LLC and Venmar Ventilation ULC (either being the "Company") warrants to the original consumer purchaser of its product ("you") that the product (the "Product") will be free from material defects in the Product or its workmanship for a period of one (1) year from the date of original purchase (or such longer period as may be required by applicable law). For Range Hood Product that includes built-in LED modules, the Company warrants the LED modules and driver to be free from material defects for a period of three (3) years from the date of purchase. The limited warranty period for any replacement parts provided by the Company and for any Products repaired or replaced under this limited warranty shall be the remainder of the original warranty period (or such longer period as may be required by applicable law).

This warranty does not cover fluorescent lamp starters, tubes, halogen and incandescent bulbs, fuses, filters, ducts, roof caps, wall caps and other accessories for ducting that may be purchased separately and installed with the Product. This warranty also does not cover (a) normal maintenance and service, (b) normal wear and tear, (c) any Products or parts which have been subject to misuse, abuse, abnormal usage, negligence, accident, improper or insufficient maintenance, storage or repair (other than repair by the Company), (d) damage caused by faulty installation, or installation or use contrary to recommendations or instructions, (e) any Product that has been moved from its original point of installation, (f) damage caused by environmental or natural elements, (g) damage in transit, (h) natural wear of finish, (i) Products in commercial or nonresidential use, or (j) damage caused by fire, flood or other act of God or (k) Products with altered, defaced or removed serial numbers. This warranty covers only Products sold to original consumers in the United States and Canada by the Company or its U.S. and Canadian distributors authorized by the Company. This warranty supersedes all prior warranties and, subject to applicable law, is not transferable from the original consumer purchaser.

No Other Warranties

This Limited Warranty contains the Company's sole obligation and your sole remedy for defective products. The foregoing warranties are exclusive and in lieu of any other warranties and conditions, express or implied. THE COMPANY DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS WARRANTIES AND CONDITIONS, AND DISCLAIMS AND EXCLUDES ALL WARRANTIES AND CONDITIONS IMPLIED BY LAW, INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. To the extent that applicable law prohibits the exclusion of implied warranties or conditions, the duration of any applicable implied warranty or condition is limited to the period specified for the express warranty above. Some jurisdictions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Any oral or written description of the Product is for the sole purpose of identifying it and shall not be construed as an express warranty. Whenever possible, each provision of this Limited Warranty shall be interpreted in such manner as to be effective and valid under applicable law, but if any provision is held to be prohibited or invalid, such provision shall be ineffective only to the extent of such prohibition or invalidity, without invalidating the remainder of such provision or the other remaining provisions of the Limited Warranty.

Remedy

During the applicable limited warranty period, the Company will, at its option, provide replacement parts for, or repair or replace, without charge, any Product or part thereof, to the extent the Company finds it to be covered by and in breach of this limited warranty under normal use and service. The Company will ship the repaired or replaced Product or replacement parts to you at no charge. You are responsible for all costs for removal, reinstallation and shipping, insurance or other freight charges incurred in the shipment of the Product or part to the Company. If you must send the Product or part to the Company, as instructed by the Company, you must properly pack the Product or part--the Company is not responsible for damage in transit. The Company reserves the right to utilize reconditioned, refurbished, repaired or remanufactured Products or parts in the warranty repair or replacement process. Such Products and parts will be comparable in function and performance to an original Product or part and warranted for the remainder of the original warranty period (or such longer period as may be required by applicable law). Company reserves the right, in its sole discretion, to refund the money actually paid by you for the Product in lieu of repair or replacement. If the Product or component is no longer available, replacement may be made with a similar product of equal or greater value, at Company's sole discretion. This is your sole and exclusive remedy for breach of this limited warranty.

Exclusion of Damages

THE COMPANY'S OBLIGATION TO PROVIDE REPLACEMENT PARTS, OR REPAIR, REPLACE OR REFUND, AT THE COMPANY'S OPTION, SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY AND THE COMPANY'S SOLE AND EXCLUSIVE OBLIGATION. THE COMPANY SHALL NOT BE LIABLE FOR INCIDENTAL, INDIRECT, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE PRODUCT, ITS USE OR PERFORMANCE. Incidental damages include but are not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if the Product does not work properly. THE COMPANY SHALL NOT BE LIABLE TO YOU, OR TO ANYONE CLAIMING UNDER YOU, FOR ANY OTHER OBLIGATIONS OR LIABILITIES, INCLUDING, BUT NOT LIMITED TO, OBLIGATIONS OR LIABILITIES ARISING OUT OF BREACH OF CONTRACT OR WARRANTY, NEGLIGENCE OR OTHER TORT OR ANY THEORY OF STRICT LIABILITY, WITH RESPECT TO THE PRODUCT OR THE COMPANY'S ACTS OR OMISSIONS OR OTHERWISE. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from jurisdiction to jurisdiction. The disclaimers, exclusions, and limitations of liability under this warranty will not apply to the extent prohibited by applicable law.

This warranty covers only replacement or repair of defective Products or parts thereof at the Company's main facility and does not include the cost of field service travel and living expenses.

Any assistance the Company provides to or procures for you outside the terms, limitations or exclusions of this limited warranty will not constitute a waiver of such terms, limitations or exclusions, nor will such assistance extend or revive the warranty.

The Company will not reimburse you for any expenses incurred by you in repairing or replacing any defective Product, except for those incurred with the Company's prior written permission.

How to Obtain Warranty Service

To qualify for warranty service, you must (a) notify the Company at the address or telephone number stated below within seven (7) days of discovering the covered defect, (b) give the model number and part identification and (c) describe the nature of any defect in the Product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. If you cannot provide a copy of the original written limited warranty, then the terms of the Company's most current written limited warranty for your particular product will control. The most current limited written warranties for the Company's products can be found at www.Broan-NuTone.com, www.broan.ca and www.nutone.ca.

Broan-NuTone LLC
926 West State Street, Hartford, WI 53027
www.Broan-NuTone.com
1-800-558-1711

Venmar Ventilation ULC
550 Lemire Blvd., Drummondville, Québec, Canada J2T 7W9
www.broan.ca
www.nutone.ca
1-877-896-1119

PDF preview unavailable. Download the PDF instead.

Install-BKDD-DF-SA2-SM-SR-CKSL-NKDF-SA-SH PDF-XChange Editor 8.0.333 PDF-XChange Core API SDK (8.0.333)

Related Documents

Preview Broan BCS3 and NCS3 Series Range Hoods: Installation, Use, and Care Manual
Comprehensive installation instructions, use and care guide, and safety information for Broan BCS3 and NCS3 Series Range Hoods, covering setup, operation, maintenance, and parts.
Preview Broan-NuTone WhispAire & Quiet Hood Installation, Safety, and Maintenance Guide
Comprehensive guide for installing, operating, and maintaining Broan-NuTone WhispAire (WA6500 Series) and Quiet Hood (QT20000 Series) range hoods. Includes safety warnings, installation steps with textual diagram descriptions, wiring, filter maintenance, replacement parts, and warranty information.
Preview Broan F40000 Series 4-Way Convertible Range Hood Installation Guide
Comprehensive installation guide for the Broan F40000 Series 4-Way Convertible Range Hood, covering ducting options, preparation, installation steps, and usage instructions. Includes safety warnings and maintenance tips.
Preview Broan BBN3306SS/SSC Powerpack Insert Range Hood: Installation, Use, and Care Guide
Comprehensive guide for installing, using, and maintaining the Broan BBN3306SS and BBN3306SSC powerpack insert range hoods. Includes safety warnings, operation instructions, and maintenance tips.
Preview Broan-NuTone Range Hood Installation, Use, and Care Manual
A quick start guide for installing, using, and maintaining Broan-NuTone range hoods. Includes safety warnings, installation steps, operation instructions, and cleaning recommendations.
Preview Broan 659 Owner's Manual: Installation, Use, and Care Guide
This manual provides comprehensive instructions for the Broan 659 heater, fan, and light unit, covering installation, operation, maintenance, and warranty information. It also details service parts for models 655, 655MX, 657, and 659.
Preview Broan 614804 Range Hood Owner's Manual and Installation Guide
Comprehensive owner's manual and installation guide for the Broan 614804 range hood, covering safety precautions, installation steps, wiring, maintenance, operation, and warranty information.
Preview Broan-NuTone F40000 Series Range Hood Installation and User Manual
Comprehensive guide for installing and using the Broan-NuTone F40000 Series 4-Way Convertible Range Hood. Covers ducting options, preparation, installation steps, and maintenance.