Safety Instructions
⚠️ WARNING - READ AND SAVE THIS INSTRUCTION BEFORE USING THIS PRODUCT.
Failure to follow these instructions may damage the appliance and/or void the warranty.
- Remove all packaging material and check for damage or missing items before operating.
- Ensure household power supply matches the appliance's specification.
- DO NOT operate with a damaged cord or plug. Discard or return for repair.
- Use only on GFCI protected receptacles. Consult a qualified electrician if necessary.
- DO NOT run the cord under carpeting, rugs, runners, or similar coverings. DO NOT route the cord under furniture or appliances. Keep the cord away from traffic areas to prevent tripping.
- Suitable for use with solid state speed control.
- DO NOT touch the appliance or plug with wet hands or while standing in water.
- DO NOT operate in pooled water.
- DO NOT use in areas with gasoline, paint, or other flammable goods.
- DO NOT insert objects into ventilation or exhaust openings.
- DO NOT cover the air inlet or outlet.
- DO NOT direct airflow at human faces or bodies.
- DO NOT allow children to play around or with the appliance.
- AUTOMATICALLY OPERATED DEVICE – Disconnect from power supply before servicing.
- Remove the power cord by grasping the plug-end only, DO NOT pull the cord directly.
- DO NOT attempt to repair or adjust electrical or mechanical functions.
- If the appliance is damaged or malfunctions, DO NOT continue use. Unplug and refer to troubleshooting or contact XPOWER.
- Store in a dry area, away from sunlight, extreme temperatures, and humidity.
- DO NOT stack more than four units.
- An electronic manual is available at www.xpower.com.
Items Included
- Axial Fan Body x 1*
- Axial Fan x 1**
- Owner's Manual x 1
- Rack x 1*
- Rubber Washer x 2*
- Rack Handle x 2*
* For model X-39AR, P-39AR only.
** For model X-47ATR only.
Parts Description
Diagram showing an exploded view of the axial fan with numbered components:
- (1) Front Grille Cover
- (2) Motor
- (3) Housing
- (4) Additional Electrical Receptacle
- (5) Capacitor
- (6) Housing Handle
- (7) Switch Plate
- (8) Rack Handle
- (9) Rubber Washer
- (10) Rack
- (11) Circuit Board
- (12) Fan
- (13) Rear End Cover
- (14) Rear Grille Cover
- (15) Power Cord
Axial Fan Introduction
- XPOWER Axial Fans offer efficient air circulation and ventilation with high and long-distance focused airflow.
- Ideal for air circulation and ventilation in janitorial/sanitation jobs, water damage restoration, and more.
Installation and Operation Guide
Installing the Rack*
Diagram showing rack installation:
- Fit rubber washers onto bolts on both sides of the unit.
- Align the rack onto the axial fan.
- Fasten the connection with the rack handle.
* For model X-39AR and P-39AR only.
Switch Plate
Diagram of a variable speed switch dial with positions: MAX, OFF, LOW.
Variable Speed Switch
- Turn to “OFF” to switch the fan OFF. Turn clockwise to any position between “MAX” and “LOW” to switch the fan ON.
- Speed is adjustable variably. “MAX” is the highest speed and “LOW” is the lowest speed.
Additional Electrical Receptacle (Daisy Chain)
Diagram showing two electrical outlets and a circuit breaker labeled "12A". Text indicates "TOTAL OUTPUT 12 AMPS MAX WITH THIS UNIT OFF, 10 AMPS MAX WITH THIS UNIT ON".
- Other appliances can be plugged into the additional receptacles and work whether the fan is on or off. The total amperage must be lower than the indicated amperage.
- If the fan or plugged-in appliance stops working, press the RESET BUTTON to reset the circuit.
Timer Switch*
Diagram of a timer dial with positions: 0, 60, 120, 180, ON.
- Turn clockwise to set the timer for minutes count down to an automatic stop.
- The timer can be set for up to 180 minutes (3 hours).
- When the timer reaches “0”, the unit stops working. On “ON”, it works constantly.
* For model X-47ATR only.
Adjust Operation Position
Diagrams showing the fan's 360° rotation and tilting capabilities, and airflow patterns.
- The Axial Fan features 360° Rotation. Tilt the Axial Fan to the desired angle and screw on rack handles to secure the fan's position.
Use without Rack*
Diagram showing the fan without the rack attached.
- Uninstall the rack and place the Axial Fan on a level surface.
* For model X-47ATR only.
Transportation
Diagram showing how to lift the fan by its handle.
- Lift the Axial Fan with the handle on the top.
User Maintenance Instructions
Frequent maintenance is recommended. Failure to follow instructions may cause failure or void the warranty.
- When not in use, unplug and store the appliance in a dry, cool indoor place, out of reach of children.
- Always disconnect the fan from its power source before performing maintenance or cleaning.
- Use a damp cloth to wipe the housing surface. Do not clean with water directly.
- Check grille covers for cleanliness. Remove dirt or objects blocking air inlet/outlet.
- DO NOT stack more than four units.
Fasten the Rack Handles
Diagrams showing how to secure the rack handles.
- To prevent injury, position the Axial Fan UPRIGHT when finished using it.
- Fasten the rack handle to lock the fan's position.
Organize the Power Cord
Diagrams showing how to wrap the power cord around the housing and clip it.
- Wrap the power cord around the housing.
- Clip the cord to the cord clip on the plug.
Troubleshooting Guide
PROBLEM | POSSIBLE CAUSE | SOLUTION |
---|---|---|
Axial fan does not start | No electricity. | Check for power supply. |
The power cord is not properly plugged in. | Remove and reconnect the power cord. | |
The circuit breaker on the additional electrical receptacle (Daisy chain) jumps. | Remove all appliances from the additional electrical receptacle and press "Reset". | |
The timer switch is set to "0" position.* | Set the timer switch to "ON" position. | |
Unit runs but the speed is abnormal | Air inlet or air outlet is blocked. | Remove blockage. |
*The timer function does not apply to all models mentioned in this manual.
If troubleshooting does not resolve your problem, contact XPOWER or authorized parties for further instructions.
Technical Specification
MODEL NUMBER | X-39AR | P-39AR | X-47ATR |
---|---|---|---|
Voltage/Frequency | 115 V~60 Hz | ||
Amperage | 1.6 A | 1.0 A | 2.8 A |
Motor Power | 1/4 HP | 1/3 HP | |
Rated Airflow | 2100 CFM | 3600 CFM | |
Speed Control | Variable Speeds | 4 Speeds | Variable Speeds |
Timer | N/A | 3 hours (OFF) | |
Additional Electrical Receptacles (Daisy Chain) | Yes | ||
Cord Length | 20 ft. / 6.1 m | ||
Housing | ABS | PP | ABS |
Unit Dimension (L) x (W) x (H) | 18.6 x 9.4 x 19.2 in. / 47.2 x 23.9 x 48.8 cm | 21.9 x 9.8 x 22.5 in. / 55.6 x 24.9 x 57.1 cm | |
Unit Weight | 16.5 lbs. / 7.5 kg | 14.5 lbs./ 6.57 kg | 22.2 lbs. / 10.1kg |
Safety Certification | ETL/C-ETL |
If your product(s) is not listed above, please visit www.xpower.com for more information.
XPOWER Limited Warranty (USA)
1 YEAR LIMITED WARRANTY
XPOWER-branded products purchased in the U.S. from authorized distributors include a 1-year limited warranty. Contact XPOWER to confirm warranty information.
This limited warranty covers defects in materials and workmanship for XPOWER-branded products purchased in the U.S. ONLY. Local warranty policy covers products purchased outside the U.S.
! IMPORTANT:
- Please complete online warranty registration before usage. Visit www.xpower.com/service-support/warranty-registration.
- This Limited Warranty applies with its own timeliness. Contact XPOWER or visit www.xpower.com for more information.
Items not covered by warranty:
- Power cord, filters, or other consumable parts.
- Normal wear and tear.
- Problems resulting from:
- External causes (accident, abuse, misuse, power supply issues).
- Unauthorized disassembly, servicing, or modification.
- Usage not in accordance with product instructions.
- Failure to follow instructions or lack of necessary maintenance.
Before contacting XPOWER:
- Consult this Owner's Manual and troubleshooting guide.
- Access www.xpower.com for advice and information.
For additional assistance from XPOWER:
- Email: info@xpower.com
- Call: XPOWER U.S. Customer Service at 855-855-8868 or other numbers on www.xpower.com.
- Visit: XPOWER U.S. Head Office at 668 S. 6th Ave., City of Industry, CA 91746 or the most current address on www.xpower.com.
Have your proof of purchase and serial number ready when contacting XPOWER.
Returning Unit for Service or Replacement:
- Request a RMA (Return-Merchandise-Authorization) number.
- Use original or equivalent packaging, prepay shipping charges to the address provided by XPOWER, including the RMA number.
- Include all original parts and components.
XPOWER will inspect and advise on repairs and costs. For warranted products, XPOWER pays shipping for repaired/replaced products within the Contiguous United States. Otherwise, shipping is at the customer's expense.
User Maintenance Instructions (Continued)
Stack Multiple Units
Diagram showing three fans stacked on their sides, with air inlets aligned.
- Stack Axial Fans on the sides, aligning the air inlets.
! ATTENTION
- DO NOT stack more than four units.
- Stacking is not secure during transportation.