GREE Vireo Gen 3 Submittal Data
Product Models: 3VIR09HP230V1AH / 3VIR09HP230V1BO
System Type: 9000 BTU/H Wall Mounted Heat Pump System
Job Name: [Enter Job Name]
Purchaser: [Enter Purchaser Name]
Submitted to: [Enter Submission Details]
Unit Designation: [Enter Unit Designation]
Location: [Enter Location]
Engineer: [Enter Engineer Name]
For: [Enter Project Details]
Schedule No.: [Enter Schedule Number]
Included Units:
- YAP1F7F (Indoor Unit Model Reference)
- 3VIR09HP230V1AH (Indoor Unit)
- 3VIR09HP230V1BO (Outdoor Unit)
- XE71 (Optional Remote Controller)
General Features
- AHRI Certificate: 210278967
- High Efficiency DC Inverter Technology
- Compact and Quiet Design
- Auto-Clean Function on Indoor Unit
- Wireless Remote with LCD Display
- Wired Controller Options
- Wi-Fi Included (Factory Installed)
- Low Ambient Cooling down to -20°F (Range -20°F to 122°F)
- Low Ambient Heating down to -22°F (Range -22°F to 86°F)
- Coil (Indoor and Outdoor) Copper Tube / Aluminum Fin
- Blue Colored Fin - 500 Hrs Salt Spray Tested
Specifications, Features & Function Summary
System Performance
Specification | Model | Min - Max | Unit |
---|---|---|---|
Cooling Capacity @95°F | 3VIR09HP230V1AH | 1535 - 10747 | Btu/h |
3VIR09HP230V1BO | 9100 | Btu/h | |
Heating Capacity | 3VIR09HP230V1AH | 3412 - 14672 | Btu/h |
3VIR09HP230V1BO | 9100 | Btu/h | |
Capacity @5°F | 3VIR09HP230V1AH | 9100 | Btu/h |
Capacity @17°F | 3VIR09HP230V1AH | 7000 | Btu/h |
Capacity @47°F | 3VIR09HP230V1AH | 10500 | W |
SEER2 | 3VIR09HP230V1AH / 3VIR09HP230V1BO | 25.5 | |
EER2 | 3VIR09HP230V1AH / 3VIR09HP230V1BO | 14.7 | |
HSPF2 | 3VIR09HP230V1AH / 3VIR09HP230V1BO | 10.2 | |
COP @5°F | 3VIR09HP230V1AH / 3VIR09HP230V1BO | 1.9 | |
COP @47°F | 3VIR09HP230V1AH / 3VIR09HP230V1BO | 3.9 | |
Cooling Temperature Range | 3VIR09HP230V1AH / 3VIR09HP230V1BO | -20 - 122 | °F |
Heating Temperature Range | 3VIR09HP230V1AH / 3VIR09HP230V1BO | -22 - 86 | °F |
Refrigerant Type | 3VIR09HP230V1AH / 3VIR09HP230V1BO | R410A |
Indoor Unit (3VIR09HP230V1AH)
Specification | Value |
---|---|
Air flow (Min-Max) | 159 - 353 CFM |
Sound Pressure Level (Min - Max) | 25 - 40 dB(A) |
Dehumidification | 1.69 pt/hr |
External Dimensions (WxHxD) | 32-1/2 x 11-9/16 x 7-3/4 in |
Package Dimension (W x H x D) | 34-7/16 x 14-3/8 x 10-9/16 in |
Net Weight | 20.9 lbs |
Gross Weight | 25.4 lbs |
Outdoor Unit (3VIR09HP230V1BO)
Specification | Value |
---|---|
Compressor Type | GREE G-10 / 2 - STAGE INVERTER |
Sound Pressure Level | 52 dB(A) |
External Dimensions (WxHxD) | 31-5/8 x 21-7/8 x 13-13/16 in |
Package Dimension (W x H x D) | 34-3/8 x 24-7/16 x 15-11/16 in |
Net Weight | 70.6 lbs |
Gross Weight | 76.1 lbs |
Refrigerant Piping
Specification | Value |
---|---|
Refrigerant Charge - R410A | 35.3 oz |
Additional Charge | 0.2 oz/ft |
Line Set Size (Liquid - Gas) - Flared Connections | 1/4 - 3/8 in |
Pre-Charge Length | 25 ft |
Pipe Length (Min - Max) | 10 - 49 ft |
Max. Pipe Elevation | 33 ft |
Electrical
Specification | Value |
---|---|
Power Supply | 208-230V / 1Ph / 60Hz (Powered by the Outdoor Unit) |
Voltage Range (Min - Max) | 187 - 253 VAC |
Rated Current - Cooling | 4.7 A |
Rated Current - Heating | 6 A |
MCA | 10 A |
MOCP | 15 A |
Suggested Breaker Size | 10 A |
Main Power Wire Size | Per Local Code AWG |
Interconnecting Wire Size | 14/4 AWG |
System Features
Feature | 3VIR09HP230V1AH / 3VIR09HP230V1BO |
---|---|
Inverter Type | G10 |
Ultra Low Frequency Torque Control | Yes |
Power Factor Correction | Yes |
Compressor Type - Inverter | High Efficiency Rotary |
Basepan With Electric Heater | Yes |
Indoor & Outdoor Fin Coating (Blue Fin) | Yes |
Intelligent Defrosting | Yes |
Intelligent Preheating | Yes |
Low Voltage Startup | Yes |
Memory/Power Failure Recovery | Yes |
Self Diagnosis | Yes |
Wired Controller Interface (XE71 or XK76 optional) | Yes |
WiFi Included | Yes |
NEW! Easy Service Access | Yes |
Indoor Fan Type | Crossflow |
Multi Fan Speeds | 7 Speeds |
Indoor Unit Display | Yes |
Auxilary Electrical Heater | No |
Ventilation (Outdoor Air) | No |
Remote Controller Functions
Function | 3VIR09HP230V1AH / 3VIR09HP230V1BO |
---|---|
NEW! Auto Clean | Yes |
Auto Mode | Yes |
Auto Fan | Yes |
Auto Swing (Horizontal Auto Swing) | Yes |
Auto Swing - 180° (Vertical Auto Swing) | Yes |
Clock | Yes |
Dry Mode | Yes |
Dry Anti-Mildew (X-Fan) Mode | Yes |
Energy Saving Mode | Yes |
Dirty Filter Alert | No |
Fan Speed Control (7 Speeds) | Yes |
I Feel Function | Yes |
Privacy Lock | Yes |
Quiet Mode | Yes |
Room Temperature Display | No |
Sleep Mode | Yes |
3 Sleep Mode Options | Yes |
Timer Mode | Yes |
Turbo Mode | Yes |
Display On/Off Control | Yes |
Freeze Guard Mode | Yes |
Power Failure Mode | Yes |
Dimensions
Indoor Unit (3VIR09HP230V1AH)
Unit: inch
Dimensions:
- W: 32-1/2
- H: 11-9/16
- D: 7-3/4
- W1: 4-29/64
- W2: 21-11/32
- W3: 6-11/16
Diagram Description: A visual representation of the indoor unit showing its width (W), height (H), depth (D), and mounting bracket dimensions (W1, W2, W3). The diagram includes labels for these dimensions and shows the unit's overall form factor.
Outdoor Unit (3VIR09HP230V1BO)
Unit: inch
Dimensions:
- A: 29-21/64
- B: 31-5/8
- C: 21-7/8
- D: 11-13/16
- E: 13-13/16
- F: 20-5/32
- G: 13-5/64
Diagram Description: A visual representation of the outdoor unit showing its dimensions labeled A (width), B, C (height), D, E, F, and G. The diagram includes top, front, and side views of the unit.
Clearances
Indoor Unit Minimum Clearance
Diagram Description: An illustration showing the indoor unit mounted on a wall, with arrows indicating required clearances. It depicts space needed from the ceiling, wall, floor, and any obstructions to ensure proper airflow and operation.
- Space to the ceiling: at least 3 inches
- Space to the wall: at least 2 inches
- Space to the floor: at least 48 inches
- Space to the obstruction: at least 48 inches
Outdoor Unit Minimum Clearance
Diagram Description: An illustration showing the outdoor unit installed, with arrows indicating required clearances. It shows spacing needed from the wall and various obstructions to maintain airflow and prevent overheating.
- Space to the wall: at least 6 inches
- Space to the obstruction: at least 12 inches
- Space to the obstruction: at least 6 inches
- Space to the obstruction: at least 24 inches
- Space to the wall: at least 2 inches
NOTE: If the bottom of the unit is free of airflow obstructions similar to the mounting bracket figure, the clearance to the wall on the back can be reduced to 3 inches.
[ETL US Mark]
Specifications are subject to change without notice. Manufacturer reserves the right to discontinue or modify specifications or designs without notice or without incurring obligations. All Rights reserved.