Secop NLE10CNT Compressor
Model: NLE10CNT
Voltage: 220-230V 50Hz / 208-230V 60Hz
Configuration Type: RSCR (Primary focus, but others detailed)
Single Pack Code: 195B4560
Single Pack Components
Position | Title | Code | Amount |
---|---|---|---|
1 | Compressor NLE10CNT | 105H6179 | 1 |
2 | e-PTC starting device (220V, 25Ω, 4.8mm) | 103N0050 | 1 |
3 | Run capacitor holder | 117-0300 | 1 |
4 | Screw for bracket M4x8mm | 117-0301 | 1 |
5 | Run capacitor (4µF 320V, 4.8mm) | 117-7119 | 1 |
6 | Cord relief | 103N1010 | 1 |
7 | Cover | 103N2011 | 1 |
8 | Bolt joint for one compressor | M6 | Ø16mm | 118-1917 | 1 |
Compressor General Data
Model Designation: NLE10CNT
Sales Code: 105H6179
Refrigerant: R290
Compressor Design
Oil type | Polyolester |
---|---|
Oil viscosity | 32cST |
Oil quantity | 268cm³ / 9.1fl.oz |
Refrigerant charge - tech. limit | 400g / 14.1oz |
Free gas volume comp. | 2360cm³ / 79.8fl.oz |
Weight | 11.8kg / 26lbs |
Motor protection | 1# internal |
Winding resistance main | 4.47Ω (at 25°C) |
Winding resistance aux | 18.69Ω (at 25°C) |
Max. winding temp. | 125°C / 257°F |
Max. discharge temp. | 120°C / 248°F |
Displacement | 10.09cm³ / 0.62cu.in |
Compressors on pallet | 80 |
Compressor Dimensions
Diagram shows a side view of the compressor with labels A, B, C, D, E for housing dimensions and X, Y, Z for connector positions.
Dimension | Value (mm / in) |
---|---|
A Height | 203mm / 7.99in |
B Height | 197mm / 7.76in |
C Length shell | 205mm / 8.07in |
D Length w. cover | 254mm / 10in |
E Width | 166mm / 6.54in |
Connectors
Diagram shows connector positions X, Y, Z with angles and dimensions.
Position | |||
---|---|---|---|
Suction (X) | Discharge (Y) | Process (Z) | |
Diameter [mm] | Øi 8.11-8.29 | Øi 6.41-6.59 | Øi 6.41-6.59 |
(i:inside, o:outside) [in] | Øi 0.32-0.33 | Øi 0.25-0.26 | Øi 0.25-0.26 |
Material | copper | copper | copper |
Horizontal angle | +2° | 0° | 0° |
Vertical angle | +2° | 15° | 155° |
Position l/h/w [mm] | 132/69/57 | 94/102/81 | -109/94/72 |
Position l/h/w [in] | 5.2/2.7/2.2 | 3.7/4/3.2 | -4.3/3.7/2.8 |
Straight tube l. [mm] | 12 | 12 | 12 |
Straight tube l. [in] | 0.5 | 0.5 | 0.5 |
Compressor Fixation
Diagram illustrates mounting points and accessories.
Fixation Type | Baseplate [mm] | Baseplate [inch] | Large holes [mm] | Large holes [inch] | Small holes [mm] | Small holes [inch] |
---|---|---|---|---|---|---|
Baseplate | 204 | 8.03 | 132 | 5.2 | Ø 9.7 | Ø 0.38 |
Large holes | 165 | 6.5 | Ø 19 | Ø 0.75 | ||
Small holes | 170 | 6.7 | 70 | 2.76 | Ø 16 | Ø 0.63 |
Mounting Accessories
Accessory | One Comp. Code | Multi Pack Code |
---|---|---|
Bolt joint | M6 | Ø16mm | 118-1917 | 118-1918 |
Bolt joint | Ø1/4" | Ø16mm | 118-1946 | 118-1919 |
Bolt joint | Ø1/4" | Ø19mm | 118-1949 | |
Snap-on | Ø7.3 | Ø16mm | 118-1947 |
LRA value on compressor label and datasheet may differ due to different test conditions for UL approval. Provision for PE Grounding is located at the PE Stamp on the compressor.
Configurations Overview
The NLE10CNT compressor is available in five configurations (Conf. 1-5) with varying motor configurations, power supplies, and electrical characteristics.
Feature | Conf. 1 | Conf. 2 | Conf. 3 | Conf. 4 | Conf. 5 |
---|---|---|---|---|---|
Motorconfiguration | CSIR | CSIR | RSIR | RSCR | RSCR |
Power supply (nominal) | 208-230V/60Hz | 220-230V/50Hz | 220-230V/50Hz | 208-230V/60Hz | 220-230V/50Hz |
Number of phases | 1 | 1 | 1 | 1 | 1 |
Voltage range | 187-253V | 187-242V | 187-242V | 187-253V | 187-242V |
Approvals | UL, CB, CCC | UL, CB, CCC | UL, CB | UL, CB | UL, CB |
Starting torque | HST | HST | LST | LST | LST |
Note | Important !! CSIR configuration uses different relays for 50Hz and 60Hz. Check accessories table. |
Applications
Feature | Conf. 1 | Conf. 2 | Conf. 3 | Conf. 4 | Conf. 5 |
---|---|---|---|---|---|
Refrigerant | R290 | R290 | R290 | R290 | R290 |
Application | LBP+MBP | LBP+MBP | LBP+MBP | LBP+MBP | LBP+MBP |
System cooling | fan 3m/s | fan 3m/s | fan 3m/s | fan 3m/s | fan 3m/s |
Hot gas defrost | OK | OK | OK | OK | OK |
Long interval pull down | OK | OK | OK | OK | OK |
Electrical Data
Parameter | Conf. 1 | Conf. 2 | Conf. 3 | Conf. 4 | Conf. 5 |
---|---|---|---|---|---|
Starting device type | relay | relay | PTC | PTC | PTC |
Run capacitor | -/- | -/- | -/- | 4µF | 4µF |
Start capacitor | 60µF | 60µF | -/- | -/- | -/- |
LRA (locked rotor amps / 4s) | 17.1A | 17.1A | 16.6A | 15.8A | 16.6A |
RLA (rated load amps / 1s) | 2.4A | 3.4A | 3.4A | 2.3A | 3A |
Cut in current | 17.1A | 17.1A | 20.7A | 19.6A | 20.7A |
Performance Data
Detailed performance tables are provided for various operating conditions (evaporating and condensing pressures, temperatures) across different configurations.
Configuration 1: CSIR (208-230V/60Hz)
Optimization + Standard Conditions
Conditions | Cooling Capacity | COP | EER | Power Consumption | Current Consumption | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | [A] | [kg/h] | |||
ASHRAE LBP -23°C/-10°F | 605.9 | 2069 | 521.4 | 1.63 | 5.57 | 1.40 | 371.6 | 2.36 | 6.14 | ||
cecomaf LBP -25°C/-13°F | 451.9 | 1543 | 388.9 | 1.27 | 4.32 | 1.09 | 357.0 | 2.31 | 5.63 | ||
EN12900 LBP -35°C/-31°F | 346.5 | 1183 | 298.2 | 1.29 | 4.40 | 1.11 | 268.7 | 2.06 | 3.96 | ||
ASHRAE MBP -7°C/20°F | 1077.8 | 3681 | 927.6 | 2.10 | 7.17 | 1.81 | 513.4 | 2.86 | 12.29 | ||
cecomaf MBP -10°C/14°F | 859.9 | 2937 | 740.1 | 1.76 | 6.01 | 1.51 | 488.7 | 2.77 | 10.88 | ||
EN12900 MBP -10°C/14°F | 947.0 | 3234 | 815.0 | 2.12 | 7.23 | 1.82 | 447.6 | 2.61 | 11.63 |
Performance Tables
Evap. Temp. [°C/°F] | Cond. Pressure [°C/°F] | Cooling Capacity | COP | EER | Power Consumption | Ref. Mass Flow [kg/h] | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | [A] | ||||
R290, 230V/60Hz, CSIR, fan 3m/s, UL, CB, CCC | |||||||||||
-35 / -31 | -23 / -10 | 330.1 | 1127 | 284.1 | 1.21 | 4.15 | 1.04 | 271.9 | 2.06 | 3.70 | |
-23 / -10 | -23 / -10 | 576.1 | 1968 | 495.8 | 1.62 | 5.53 | 1.39 | 356.0 | 2.31 | 6.51 | |
-15 / 5 | -15 / 5 | 814.7 | 2782 | 701.1 | 1.96 | 6.71 | 1.69 | 414.7 | 2.50 | 9.27 | |
-9 / 15 | -9 / 15 | 1006.2 | 3437 | 866.0 | 2.23 | 7.62 | 1.92 | 451.1 | 2.63 | 11.52 | |
-4 / 25 | -4 / 25 | 1225.8 | 4186 | 1055.0 | 2.53 | 8.65 | 2.18 | 484.0 | 2.75 | 14.14 | |
0 / 32 | 0 / 32 | 1397.1 | 4771 | 1202.4 | 2.77 | 9.46 | 2.38 | 504.5 | 2.82 | 16.21 | |
7.2 / 45 | 7.2 / 45 | 1756.1 | 5997 | 1511.3 | 3.28 | 11.20 | 2.82 | 535.3 | 2.95 | 20.63 | |
-35 / -31 | -23 / -10 | 257.8 | 881 | 221.9 | 0.96 | 3.29 | 0.83 | 267.5 | 2.03 | 3.19 | |
-23 / -10 | -23 / -10 | 489.9 | 1673 | 421.6 | 1.32 | 4.50 | 1.13 | 372.1 | 2.36 | 6.11 | |
-15 / 5 | -15 / 5 | 706.6 | 2413 | 608.1 | 1.58 | 5.41 | 1.36 | 446.2 | 2.61 | 8.88 | |
-9 / 15 | -9 / 15 | 878.1 | 2999 | 755.7 | 1.78 | 6.08 | 1.53 | 493.3 | 2.78 | 11.12 | |
-4 / 25 | -4 / 25 | 1073.2 | 3665 | 923.6 | 2.00 | 6.82 | 1.72 | 537.3 | 2.95 | 13.70 | |
0 / 32 | 0 / 32 | 1224.8 | 4183 | 1054.0 | 2.17 | 7.39 | 1.86 | 565.7 | 3.06 | 15.73 | |
7.2 / 45 | 7.2 / 45 | 1541.3 | 5264 | 1326.5 | 2.52 | 8.61 | 2.17 | 611.7 | 3.25 | 20.08 |
Configuration 2: CSIR (220-230V/50Hz)
Optimization + Standard Conditions
Conditions | Cooling Capacity | COP | EER | Power Consumption | Current Consumption | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | [A] | [kg/h] | |||
ASHRAE LBP -23°C/-10°F | 509.6 | 1740 | 438.6 | 1.49 | 5.08 | 1.28 | 342.4 | 2.73 | 5.16 | ||
cecomaf LBP -25°C/-13°F | 380.1 | 1298 | 327.1 | 1.16 | 3.95 | 1.00 | 328.7 | 2.68 | 4.73 | ||
EN12900 LBP -35°C/-31°F | 291.4 | 995 | 250.7 | 1.19 | 4.05 | 1.02 | 245.6 | 2.40 | 3.33 | ||
ASHRAE MBP -7°C/20°F | 907.2 | 3098 | 780.7 | 1.92 | 6.56 | 1.65 | 472.3 | 3.25 | 10.35 | ||
cecomaf MBP -10°C/14°F | 723.8 | 2472 | 622.9 | 1.61 | 5.49 | 1.38 | 450.2 | 3.16 | 9.16 | ||
EN12900 MBP -10°C/14°F | 795.4 | 2717 | 684.6 | 1.95 | 6.68 | 1.68 | 406.9 | 2.97 | 9.77 |
Performance Tables
Evap. Temp. [°C/°F] | Cond. Pressure [°C/°F] | Cooling Capacity | COP | EER | Power Consumption | Ref. Mass Flow [kg/h] | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | [A] | ||||
R290, 230V/50Hz, CSIR, fan 3m/s, UL, CB, CCC | |||||||||||
-25 / -13 | -25 / -13 | 449.0 | 1534 | 386.4 | 1.43 | 4.88 | 1.23 | 314.5 | 2.62 | 5.06 | |
-23 / -10 | -23 / -10 | 483.6 | 1651 | 416.2 | 1.49 | 5.08 | 1.28 | 325.3 | 2.66 | 5.46 | |
-15 / 5 | -15 / 5 | 684.1 | 2336 | 588.7 | 1.81 | 6.18 | 1.56 | 377.7 | 2.85 | 7.78 | |
-9 / 15 | -9 / 15 | 845.2 | 2887 | 727.4 | 2.06 | 7.04 | 1.77 | 410.0 | 2.98 | 9.68 | |
-4 / 25 | -4 / 25 | 1030.0 | 3518 | 886.5 | 2.34 | 8.01 | 2.02 | 439.3 | 3.10 | 11.88 | |
0 / 32 | 0 / 32 | 1174.2 | 4010 | 1010.5 | 2.57 | 8.77 | 2.21 | 457.4 | 3.18 | 13.62 | |
7.2 / 45 | 7.2 / 45 | 1476.2 | 5041 | 1270.4 | 3.04 | 10.39 | 2.62 | 485.1 | 3.30 | 17.34 | |
-25 / -13 | -23 / -10 | 380.1 | 1298 | 327.1 | 1.16 | 3.95 | 1.00 | 328.7 | 2.68 | 4.73 | |
-23 / -10 | -23 / -10 | 412.1 | 1407 | 354.6 | 1.20 | 4.11 | 1.03 | 342.8 | 2.73 | 5.14 | |
-15 / 5 | -15 / 5 | 594.7 | 2031 | 511.8 | 1.45 | 4.94 | 1.24 | 411.4 | 3.00 | 7.48 | |
-9 / 15 | -9 / 15 | 739.1 | 2524 | 636.1 | 1.63 | 5.56 | 1.40 | 454.3 | 3.18 | 9.36 | |
-4 / 25 | -4 / 25 | 903.3 | 3085 | 777.4 | 1.83 | 6.25 | 1.57 | 494.0 | 3.35 | 11.53 | |
0 / 32 | 0 / 32 | 1030.7 | 3520 | 887.0 | 1.98 | 6.78 | 1.71 | 519.3 | 3.46 | 13.24 | |
7.2 / 45 | 7.2 / 45 | 1296.5 | 4428 | 1115.7 | 2.31 | 7.91 | 1.99 | 560.1 | 3.65 | 16.89 |
Configuration 3: RSIR (220-230V/50Hz)
Optimization + Standard Conditions
Conditions | Cooling Capacity | COP | EER | Power Consumption | Current Consumption | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | [A] | [kg/h] | |||
ASHRAE LBP -23°C/-10°F | 509.6 | 1740 | 438.6 | 1.49 | 5.08 | 1.28 | 342.4 | 2.73 | 5.16 | ||
cecomaf LBP -25°C/-13°F | 380.1 | 1298 | 327.1 | 1.16 | 3.95 | 1.00 | 328.7 | 2.68 | 4.73 | ||
EN12900 LBP -35°C/-31°F | 291.4 | 995 | 250.7 | 1.19 | 4.05 | 1.02 | 245.6 | 2.40 | 3.33 | ||
ASHRAE MBP -7°C/20°F | 907.2 | 3098 | 780.7 | 1.92 | 6.56 | 1.65 | 472.3 | 3.25 | 10.35 | ||
cecomaf MBP -10°C/14°F | 723.8 | 2472 | 622.9 | 1.61 | 5.49 | 1.38 | 450.2 | 3.16 | 9.16 | ||
EN12900 MBP -10°C/14°F | 795.4 | 2717 | 684.6 | 1.95 | 6.68 | 1.68 | 406.9 | 2.97 | 9.77 |
Performance Tables
Evap. Temp. [°C/°F] | Cond. Pressure [°C/°F] | Cooling Capacity | COP | EER | Power Consumption | Ref. Mass Flow [kg/h] | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | [A] | ||||
R290, 230V/50Hz, RSIR, fan 3m/s, UL, CB | |||||||||||
-25 / -13 | -25 / -13 | 449.0 | 1534 | 386.4 | 1.43 | 4.88 | 1.23 | 314.5 | 2.62 | 5.06 | |
-23 / -10 | -23 / -10 | 483.6 | 1651 | 416.2 | 1.49 | 5.08 | 1.28 | 325.3 | 2.66 | 5.46 | |
-15 / 5 | -15 / 5 | 684.1 | 2336 | 588.7 | 1.81 | 6.18 | 1.56 | 377.7 | 2.85 | 7.78 | |
-9 / 15 | -9 / 15 | 845.2 | 2887 | 727.4 | 2.06 | 7.04 | 1.77 | 410.0 | 2.98 | 9.68 | |
-4 / 25 | -4 / 25 | 1030.0 | 3518 | 886.5 | 2.34 | 8.01 | 2.02 | 439.3 | 3.10 | 11.88 | |
0 / 32 | 0 / 32 | 1174.2 | 4010 | 1010.5 | 2.57 | 8.77 | 2.21 | 457.4 | 3.18 | 13.62 | |
7.2 / 45 | 7.2 / 45 | 1476.2 | 5041 | 1270.4 | 3.04 | 10.39 | 2.62 | 485.1 | 3.30 | 17.34 | |
-25 / -13 | -23 / -10 | 380.1 | 1298 | 327.1 | 1.16 | 3.95 | 1.00 | 328.7 | 2.68 | 4.73 | |
-23 / -10 | -23 / -10 | 412.1 | 1407 | 354.6 | 1.20 | 4.11 | 1.03 | 342.8 | 2.73 | 5.14 | |
-15 / 5 | -15 / 5 | 594.7 | 2031 | 511.8 | 1.45 | 4.94 | 1.24 | 411.4 | 3.00 | 7.48 | |
-9 / 15 | -9 / 15 | 739.1 | 2524 | 636.1 | 1.63 | 5.56 | 1.40 | 454.3 | 3.18 | 9.36 | |
-4 / 25 | -4 / 25 | 903.3 | 3085 | 777.4 | 1.83 | 6.25 | 1.57 | 494.0 | 3.35 | 11.53 | |
0 / 32 | 0 / 32 | 1030.7 | 3520 | 887.0 | 1.98 | 6.78 | 1.71 | 519.3 | 3.46 | 13.24 | |
7.2 / 45 | 7.2 / 45 | 1296.5 | 4428 | 1115.7 | 2.31 | 7.91 | 1.99 | 560.1 | 3.65 | 16.89 |
Configuration 4: RSCR (208-230V/60Hz)
Optimization + Standard Conditions
Conditions | Cooling Capacity | COP | EER | Power Consumption | Current Consumption | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | [A] | [kg/h] | |||
ASHRAE LBP -23°C/-10°F | 614.9 | 2100 | 529.2 | 1.72 | 5.87 | 1.48 | 358.1 | 2.09 | 6.23 | ||
cecomaf LBP -25°C/-13°F | 458.7 | 1567 | 394.8 | 1.33 | 4.55 | 1.15 | 344.0 | 2.05 | 5.71 | ||
EN12900 LBP -35°C/-31°F | 351.7 | 1201 | 302.7 | 1.36 | 4.64 | 1.17 | 258.9 | 1.83 | 4.02 | ||
ASHRAE MBP -7°C/20°F | 1094.0 | 3736 | 941.5 | 2.21 | 7.55 | 1.90 | 494.7 | 2.51 | 12.48 | ||
cecomaf MBP -10°C/14°F | 872.8 | 2981 | 751.2 | 1.85 | 6.33 | 1.59 | 470.9 | 2.44 | 11.04 | ||
EN12900 MBP -10°C/14°F | 961.2 | 3283 | 827.2 | 2.23 | 7.61 | 1.92 | 431.3 | 2.30 | 11.80 |
Performance Tables
Evap. Temp. [°C/°F] | Cond. Pressure [°C/°F] | Cooling Capacity | COP | EER | Power Consumption | Ref. Mass Flow [kg/h] | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | [A] | ||||
R290, 230V/60Hz, RSCR, fan 3m/s, UL, CB | |||||||||||
-35 / -31 | -35 / -31 | 335.0 | 1144 | 288.3 | 1.28 | 4.37 | 1.10 | 262.0 | 1.84 | 3.75 | |
-23 / -10 | -23 / -10 | 584.8 | 1997 | 503.3 | 1.70 | 5.82 | 1.47 | 343.1 | 2.04 | 6.60 | |
-15 / 5 | -15 / 5 | 826.9 | 2824 | 711.7 | 2.07 | 7.07 | 1.78 | 399.6 | 2.21 | 9.41 | |
-9 / 15 | -9 / 15 | 1021.3 | 3488 | 879.0 | 2.35 | 8.02 | 2.02 | 434.7 | 2.31 | 11.69 | |
-4 / 25 | -4 / 25 | 1244.2 | 4249 | 1070.8 | 2.67 | 9.11 | 2.30 | 466.4 | 2.41 | 14.35 | |
0 / 32 | 0 / 32 | 1418.1 | 4843 | 1220.4 | 2.92 | 9.96 | 2.51 | 486.1 | 2.48 | 16.45 | |
7.2 / 45 | 7.2 / 45 | 1782.5 | 6087 | 1534.0 | 3.46 | 11.80 | 2.97 | 515.8 | 2.58 | 20.94 | |
-35 / -31 | -23 / -10 | 261.7 | 894 | 225.2 | 1.02 | 3.47 | 0.87 | 257.8 | 1.82 | 3.24 | |
-23 / -10 | -23 / -10 | 497.2 | 1698 | 427.9 | 1.39 | 4.74 | 1.19 | 358.5 | 2.09 | 6.20 | |
-15 / 5 | -15 / 5 | 717.2 | 2449 | 617.3 | 1.67 | 5.70 | 1.44 | 430.0 | 2.31 | 9.02 | |
-9 / 15 | -9 / 15 | 891.3 | 3044 | 767.0 | 1.87 | 6.40 | 1.61 | 475.4 | 2.45 | 11.28 | |
-4 / 25 | -4 / 25 | 1089.3 | 3720 | 937.5 | 2.10 | 7.19 | 1.81 | 517.8 | 2.59 | 13.90 | |
0 / 32 | 0 / 32 | 1243.1 | 4246 | 1069.9 | 2.28 | 7.79 | 1.96 | 545.1 | 2.69 | 15.97 | |
7.2 / 45 | 7.2 / 45 | 1564.4 | 5343 | 1346.4 | 2.65 | 9.06 | 2.28 | 589.4 | 2.84 | 20.38 |
Configuration 5: RSCR (220-230V/50Hz)
Optimization + Standard Conditions
Conditions | Cooling Capacity | COP | EER | Power Consumption | Current Consumption | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | [A] | [kg/h] | |||
ASHRAE LBP -23°C/-10°F | 518.0 | 1769 | 445.8 | 1.54 | 5.25 | 1.32 | 337.0 | 2.50 | 5.25 | ||
cecomaf LBP -25°C/-13°F | 386.2 | 1319 | 332.4 | 1.19 | 4.08 | 1.03 | 323.2 | 2.45 | 4.81 | ||
EN12900 LBP -35°C/-31°F | 296.2 | 1011 | 254.9 | 1.23 | 4.21 | 1.06 | 240.0 | 2.20 | 3.38 | ||
ASHRAE MBP -7°C/20°F | 922.8 | 3151 | 794.1 | 1.99 | 6.79 | 1.71 | 464.0 | 2.98 | 10.53 | ||
cecomaf MBP -10°C/14°F | 736.3 | 2514 | 633.6 | 1.66 | 5.68 | 1.43 | 442.8 | 2.89 | 9.31 | ||
EN12900 MBP -10°C/14°F | 807.2 | 2757 | 694.7 | 2.04 | 6.97 | 1.76 | 395.5 | 2.72 | 9.91 |
Performance Tables
Evap. Temp. [°C/°F] | Cond. Pressure [°C/°F] | Cooling Capacity | COP | EER | Power Consumption | Ref. Mass Flow [kg/h] | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | [A] | ||||
R290, 230V/50Hz, RSCR, fan 3m/s, UL, CB | |||||||||||
-35 / -31 | -35 / -31 | 282.5 | 965 | 243.1 | 1.16 | 3.96 | 1.00 | 243.6 | 2.21 | 3.17 | |
-23 / -10 | -23 / -10 | 490.4 | 1675 | 422.0 | 1.54 | 5.27 | 1.33 | 317.8 | 2.44 | 5.54 | |
-15 / 5 | -15 / 5 | 694.0 | 2370 | 597.2 | 1.89 | 6.44 | 1.62 | 367.8 | 2.62 | 7.90 | |
-9 / 15 | -9 / 15 | 857.8 | 2930 | 738.3 | 2.15 | 7.35 | 1.85 | 398.4 | 2.73 | 9.82 | |
-4 / 25 | -4 / 25 | 1045.8 | 3571 | 900.0 | 2.45 | 8.38 | 2.11 | 426.1 | 2.84 | 12.06 | |
0 / 32 | 0 / 32 | 1192.4 | 4072 | 1026.2 | 2.69 | 9.18 | 2.31 | 443.4 | 2.91 | 13.83 | |
7.2 / 45 | 7.2 / 45 | 1499.3 | 5120 | 1290.3 | 3.19 | 10.90 | 2.75 | 469.8 | 3.03 | 17.62 | |
-35 / -31 | -23 / -10 | 219.8 | 751 | 189.2 | 0.93 | 3.18 | 0.80 | 236.0 | 2.18 | 2.72 | |
-23 / -10 | -23 / -10 | 418.8 | 1430 | 360.5 | 1.24 | 4.24 | 1.07 | 337.4 | 2.50 | 5.22 | |
-15 / 5 | -15 / 5 | 604.9 | 2066 | 520.6 | 1.49 | 5.10 | 1.28 | 405.1 | 2.75 | 7.61 | |
-9 / 15 | -9 / 15 | 751.8 | 2568 | 647.0 | 1.68 | 5.75 | 1.45 | 446.9 | 2.91 | 9.52 | |
-4 / 25 | -4 / 25 | 918.7 | 3138 | 790.7 | 1.89 | 6.47 | 1.63 | 485.0 | 3.07 | 11.72 | |
0 / 32 | 0 / 32 | 1048.1 | 3580 | 902.0 | 2.06 | 7.03 | 1.77 | 509.2 | 3.17 | 13.46 | |
7.2 / 45 | 7.2 / 45 | 1317.7 | 4500 | 1134.0 | 2.41 | 8.21 | 2.07 | 547.9 | 3.34 | 17.17 |
Electrical Accessories / Wiring Diagrams
Diagrams illustrate the electrical connections and components for different configurations.
Configuration 1 (CSIR)
Diagram shows main winding, winding protector, start winding, and components: a2 current relay (117U7050), c start capacitor (60µF) (117U5014), b plastic cover (103N2011), d cord relief (103N1010).
Configuration 2 (CSIR)
Diagram shows main winding, winding protector, start winding, and components: a2 current relay (117U7019), c start capacitor (60µF) (117U5014), b plastic cover (103N2011), d cord relief (103N1010).
Configuration 3 (RSIR)
Diagram shows main winding, winding protector, start winding, and components: a1 e-PTC starter (220V, 25Ohm, 4.8mm) (103N0050), b plastic cover (103N2011), d cord relief (103N1010).
Configuration 4 (RSCR)
Diagram shows main winding, winding protector, start winding, and components: a1 e-PTC starter (220V, 25Ohm, 4.8mm) (103N0050), e run capacitor (4µF, 4.8mm) (117-7119), b plastic cover (103N2011), d cord relief (103N1010), bracket for run capacitor (117-0300), screw M4x8mm (117-0301).
Configuration 5 (RSCR)
Diagram shows main winding, winding protector, start winding, and components: a1 e-PTC starter (220V, 25Ohm, 4.8mm) (103N0050), e run capacitor (4µF, 4.8mm) (117-7119), b plastic cover (103N2011), d cord relief (103N1010), bracket for run capacitor (117-0300), screw M4x8mm (117-0301).
Operating Pressure Ranges
Graphs illustrate the operating pressure ranges for different configurations, indicating continuous and transitory operation zones for evaporation and condensing pressures.
Service and Repair Information
The document includes service and repair guidelines, specifically mentioning handling of refrigerants R600a and R290, and detailed instructions for brazing on suction connectors.
Warning Symbols:
- ❗ Warning symbol for R600a refrigerant.
- ❗ Warning symbol for R290 refrigerant.
Brazing on Suction Connectors (Direct Intake):
Maximum temperature at socket: 150°C / 302°F. Brazing solder options: phosphor (LP7) or silver.
Refer to Product Bulletin: Brazing on Suction Connectors (Compressors with Direct Suction Intake).