SECOP KLF7.7CND Compressor
Model Designation: KLF7.7CND
Sales Code: 106H2805
Power Supply: 220-240V / 50Hz, 1~
Compressor Design Specifications
Parameter | Value |
---|---|
Oil type | Polyolester |
Oil viscosity | 10,4 cSt |
Oil quantity | 170 cm³ / 5,7 fl.oz |
Refrigerant charge - tech. limit | 200g / 7,1oz |
Free gas volume comp. | 1575 cm³ / 53,3 fl.oz |
Weight | 9,6 kg / 21,2 lbs |
Motor protection | External |
Winding resistance main | 8,4 Ω (at 25°C) |
Winding resistance aux | 11,9 Ω (at 25°C) |
Max. winding temp. | 125°C / 257°F |
Max. discharge temp. | 130°C / 266°F |
Refrigerant(s) | R290 |
Displacement | 7,7 cm³ / 0,47 cu.in |
Compressors on pallet | 100 |
A SECOP KLF-Series compressor unit is depicted, showing the motor housing and cooling fins.
General Configurations
Configuration 1 (CSIR)
Parameter | Value |
---|---|
Motor configuration | CSIR |
Power supply (nominal) | 220-240V/50Hz |
Number of phases | 1 |
Voltage range | 198-254V |
Approvals | VDE, CCC |
Starting torque | HST |
Note | Housing with dip-tray fixture (omega bracket). |
Configuration 2 (RSCR)
Parameter | Value |
---|---|
Motor configuration | RSCR |
Power supply (nominal) | 220-240V/50Hz |
Number of phases | 1 |
Voltage range | 198-254V |
Approvals | VDE, CCC |
Starting torque | LST |
Note | Housing with dip-tray fixture (omega bracket). |
Applications
Configuration 1
Parameter | Value |
---|---|
Refrigerant | R290 |
Application | LBP+MBP |
System cooling | fan 3m/s |
Hot gas defrost | OK |
Long interval pull down | OK |
Configuration 2
Parameter | Value |
---|---|
Refrigerant | R290 |
Application | LBP+MBP |
System cooling | fan 3m/s |
Hot gas defrost | OK |
Long interval pull down | OK |
Electrical Data
Configuration 1
Parameter | Value |
---|---|
Starting device type | relay |
Run capacitor | -/- |
Start capacitor | 80μF |
LRA (locked rotor amps / 4s/ U(N)) | 13,2A |
RLA (rated load amps / 1s/ U(N)) | 2,1A |
Cut in current (U(N)) | 12,3A |
Configuration 2
Parameter | Value |
---|---|
Starting device type | PTC |
Run capacitor | 5μF |
Start capacitor | -/- |
LRA (locked rotor amps / 4s/ U(N)) | 13,2A |
RLA (rated load amps / 1s/ U(N)) | 2,1A |
Cut in current (U(N)) | 18,1A |
Compressor Dimensions
Dimension | Value (mm) | Value (in) |
---|---|---|
Housing A Height | 182 | 7,17 |
Housing B Height | 175 | 6,89 |
Housing C Length shell | 198 | 7,8 |
Housing D Length w. cover | 238 | 9,37 |
Housing E Width | 160 | 6,3 |
Diagrams illustrate housing dimensions and connector port details (Suction, Discharge, Process) with diameters (e.g., Suction: øi 8,11-8,29 mm / øi 0,32-0,33 in), material (copper), and angles (horizontal/vertical).
Compressor Fixation and Mounting
Compressor Fixation: Details baseplate dimensions (e.g., Bl: 204 mm / 8.03 in, Bw: 132 mm / 5.2 in) and hole sizes (Large holes: ØL 165 mm / 6.5 in, ØS 19 mm / 0.75 in; Small holes: ØE 170 mm / 6.7 in, ØS 16 mm / 0.63 in) for mounting.
Mounting Accessories: Lists available bolt joints and snap-on accessories with part numbers (e.g., Bolt joint M6 | Ø16mm: 118-1917, Snap-on | Ø7,3 | Ø16mm: 118-1947).
Diagrams show bolt joint and snap-on mounting methods, including components like washers, rubber grommets, clips, and steel pins.
Ambient and Operating Conditions
Ambient/Machine Room Temperatures
Parameter | Value |
---|---|
Ambient temperature range | 10 - 43°C / 50 - 110°F |
Machine room temperature range | 10 - 48°C / 50 - 119°F |
Compressor cooling | fan 3m/s |
Operation Pressure Range
Graphs illustrate the operation pressure range, plotting condensing pressure (in bar) against evaporation pressure (in bar). Lines indicate continuous and transitory operation zones, with corresponding temperature scales in °C and °F.
Optimization + Standard Conditions
Configuration 1 (CSIR)
Conditions | Cooling Capacity | COP | EER | P1 [W] | I [A] | Ref. mass flow m [kg/h] | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W/W] | [Btu/Wh] | ||||
[°C] -23 [°F] -10 |
384,5 | 1313 | 330,9 | 1,52 | 5,18 | 1,30 | 253,7 | 1,68 | 3,89 | ||
[°C] -25 [°F] -13 |
287,6 | 982 | 247,5 | 1,18 | 4,02 | 1,01 | 244,6 | 1,65 | 3,58 | ||
[°C] -35 [°F] -31 |
222,6 | 760 | 191,6 | 1,20 | 4,12 | 1,04 | 184,8 | 1,49 | 2,54 | ||
[°C] -7 [°F] 20 |
687,7 | 2349 | 591,9 | 2,00 | 6,84 | 1,72 | 343,3 | 1,99 | 7,85 | ||
[°C] -10 [°F] 14 |
547,3 | 1869 | 471,0 | 1,67 | 5,71 | 1,44 | 327,5 | 1,93 | 6,92 | ||
[°C] -10 [°F] 14 |
608,6 | 2079 | 523,8 | 2,03 | 6,93 | 1,75 | 299,9 | 1,83 | 7,47 |
Performance Tables (Conf. 1)
Cond. Pressure | Return Gas Temp. | Liquid Temp. | Cooling Capacity | COP | EER | P1 [W] | I [A] | Ref. mass flow m [kg/h] | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W/W] | [Btu/Wh] | ||||||
pc= 45/113 | RGT= 32/90 | Tliq= 45/113 | -35 / -31 | 210,1 | 717 | 180,8 | 1,11 | 3,79 | 0,96 | 189,1 | 1,50 | 2,35 | |
-25 / -13 | 342,0 | 1168 | 294,3 | 1,46 | 4,98 | 1,26 | 234,3 | 1,62 | 3,86 | ||||
-15 / 5 | 523,0 | 1786 | 450,1 | 1,88 | 6,42 | 1,62 | 278,4 | 1,76 | 5,95 | ||||
-10 / 14 | 633,6 | 2164 | 545,3 | 2,11 | 7,22 | 1,82 | 299,9 | 1,83 | 7,25 | ||||
-5 / 23 | 758,6 | 2591 | 652,8 | 2,36 | 8,07 | 2,03 | 321,1 | 1,91 | 8,73 | ||||
0 / 32 | 898,6 | 3069 | 773,3 | 2,63 | 8,97 | 2,26 | 342,0 | 1,99 | 10,42 | ||||
7,2 / 45 | 1127,9 | 3852 | 970,7 | 3,04 | 10,37 | 2,61 | 371,3 | 2,10 | 13,25 | ||||
pc= 55/131 | RGT= 32/90 | Tliq= 55/131 | -35 / -31 | 170,7 | 583 | 146,9 | 0,92 | 3,13 | 0,79 | 186,0 | 1,49 | 2,11 | |
-25 / -13 | 287,6 | 982 | 247,5 | 1,18 | 4,02 | 1,01 | 244,6 | 1,65 | 3,58 | ||||
-15 / 5 | 448,6 | 1532 | 386,0 | 1,49 | 5,10 | 1,28 | 300,5 | 1,84 | 5,64 | ||||
-10 / 14 | 547,3 | 1869 | 471,0 | 1,67 | 5,71 | 1,44 | 327,5 | 1,93 | 6,92 | ||||
-5 / 23 | 659,1 | 2251 | 567,2 | 1,86 | 6,36 | 1,60 | 353,6 | 2,03 | 8,40 | ||||
0 / 32 | 784,6 | 2680 | 675,3 | 2,07 | 7,07 | 1,78 | 379,1 | 2,13 | 10,08 | ||||
7,2 / 45 | 991,0 | 3385 | 852,9 | 2,39 | 8,17 | 2,06 | 414,5 | 2,27 | 12,91 |
Electrical Accessories / Wiring Diagram
Configuration 1 (CSIR)
Diagram shows electrical components for Configuration 1: a current relay (T0377/L6-S1), a start capacitor (80μF, 6.3mm), and cover/clamp/screws. Alternative components include a 100x cover variant and a bagged version.
Configuration 2 (RSCR)
Diagram shows electrical components for Configuration 2: a DAS1 (PTC, 6.3mm, T0377/L6 - S1), a run capacitor (5μF, 6.3mm), and cover/clamp/screws. Alternative components include a ZAS1 (PTC, 4.8mm, T0377/L6 - S1) and a 5μF run capacitor (4.8mm).
Optimization + Standard Conditions
Configuration 2 (RSCR)
Conditions | Cooling Capacity | COP | EER | P1 [W] | I [A] | Ref. mass flow m [kg/h] | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W/W] | [Btu/Wh] | ||||
[°C] -23 [°F] -10 |
387,4 | 1323 | 333,4 | 1,60 | 5,46 | 1,38 | 242,2 | 1,36 | 3,92 | ||
[°C] -25 [°F] -13 |
289,8 | 990 | 249,4 | 1,24 | 4,24 | 1,07 | 233,6 | 1,33 | 3,61 | ||
[°C] -35 [°F] -31 |
224,1 | 765 | 192,9 | 1,27 | 4,32 | 1,09 | 177,0 | 1,13 | 2,56 | ||
[°C] -7 [°F] 20 |
693,9 | 2370 | 597,2 | 2,12 | 7,26 | 1,83 | 326,6 | 1,69 | 7,92 | ||
[°C] -10 [°F] 14 |
552,0 | 1885 | 475,1 | 1,77 | 6,05 | 1,52 | 311,7 | 1,63 | 6,98 | ||
[°C] -10 [°F] 14 |
613,6 | 2096 | 528,1 | 2,15 | 7,33 | 1,85 | 285,9 | 1,53 | 7,53 |
Performance Tables (Conf. 2)
Cond. Pressure | Return Gas Temp. | Liquid Temp. | Cooling Capacity | COP | EER | P1 [W] | I [A] | Ref. mass flow m [kg/h] | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W/W] | [Btu/Wh] | ||||||
pc= 45/113 | RGT= 32/90 | Tliq= 45/113 | -35 / -31 | 211,5 | 722 | 182,0 | 1,17 | 3,99 | 1,00 | 181,2 | 1,14 | 2,37 | |
-25 / -13 | 344,5 | 1177 | 296,5 | 1,54 | 5,25 | 1,32 | 223,9 | 1,29 | 3,89 | ||||
-15 / 5 | 527,1 | 1800 | 453,7 | 1,98 | 6,78 | 1,71 | 265,6 | 1,44 | 6,00 | ||||
-10 / 14 | 638,8 | 2182 | 549,8 | 2,23 | 7,63 | 1,92 | 285,9 | 1,53 | 7,31 | ||||
-5 / 23 | 765,1 | 2613 | 658,4 | 2,50 | 8,54 | 2,15 | 305,9 | 1,61 | 8,81 | ||||
0 / 32 | 906,6 | 3096 | 780,2 | 2,79 | 9,51 | 2,40 | 325,4 | 1,69 | 10,52 | ||||
7,2 / 45 | 1138,6 | 3888 | 979,9 | 3,23 | 11,02 | 2,78 | 352,8 | 1,80 | 13,38 | ||||
pc= 55/131 | RGT= 32/90 | Tliq= 55/131 | -35 / -31 | 171,9 | 587 | 147,9 | 0,96 | 3,30 | 0,83 | 178,1 | 1,14 | 2,13 | |
-25 / -13 | 289,8 | 990 | 249,4 | 1,24 | 4,24 | 1,07 | 233,6 | 1,33 | 3,61 | ||||
-15 / 5 | 452,3 | 1545 | 389,2 | 1,58 | 5,39 | 1,36 | 286,4 | 1,53 | 5,69 | ||||
-10 / 14 | 552,0 | 1885 | 475,1 | 1,77 | 6,05 | 1,52 | 311,7 | 1,63 | 6,98 | ||||
-5 / 23 | 665,1 | 2271 | 572,4 | 1,98 | 6,75 | 1,70 | 336,3 | 1,73 | 8,47 | ||||
0 / 32 | 792,2 | 2706 | 681,8 | 2,20 | 7,51 | 1,89 | 360,0 | 1,83 | 10,18 | ||||
7,2 / 45 | 1001,3 | 3419 | 861,7 | 2,55 | 8,71 | 2,19 | 392,8 | 1,97 | 13,04 |