General Instructions
Read this manual carefully before using the device. Keep this manual for future reference.
Meaning of Symbols
The following warning symbols and/or signal words are used in this manual:
- DANGER! This means an imminent danger due to electric current. Failure to follow safety instructions can result in serious or fatal injury and/or serious damage to the product or environment.
- WARNING! This means a dangerous situation. Failure to follow safety instructions can result in moderate or minor personal injury and/or damage to the product or environment.
- NOTICE! This means caution, useful information or advice.
Symbols on the device:
- This device is suitable for outdoor use and can be used underwater up to a 2-metre depth.
- IP68 This device is waterproof.
- CE This device complies with all applicable EU standards.
- This device may not be disposed of with normal household waste but must be collected separately for recycling.
Use
Suitable for outdoor use, for pumping pond water within the pond and inline set-up.
- The temperature of the pond water being pumped should not exceed 35°C.
- Do not use for pumping salt water, sewage water, flammable, corrosive, or explosive liquids (e.g., petroleum, petrol, solvents), fats, oils, or foodstuffs.
- Never run the device without water.
- Do not use for swimming pools and do not connect to drinking water supplies.
Safety
Always follow the safety instructions below for safe use of the device. Failure to follow these instructions may endanger persons or the environment.
- This device must be protected by an earth leakage relay breaker with a leakage current of a maximum of 30mA.
- Ensure the voltage shown on the label matches the mains supply voltage.
- This device must be connected to an earthed socket.
- Protect the socket and plug against moisture. Use a drip loop to ensure water cannot reach the socket via the cord.
- Do not use the product if the device, cord, or plug is damaged. Return the device to your dealer for repair or recycling. A damaged cord or plug cannot be replaced.
- Be careful with the combination of water and electricity. Do not operate with wet hands. Dry hands before carrying out maintenance.
- Never use the device when there are people in the water.
- Always switch off all devices at the mains supply before maintenance. Unplug the device(s).
- Do not move or lift the device out of the water by the cord; only lift the device by the handle.
- This device can be used by children aged 8 years and above, and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge, if they have been given supervision or instructions concerning the safe use of the device and understand the hazards involved. Children shall not play with the device. Cleaning and maintenance shall not be done by children without supervision.
- Modifications to the device may affect safety and will void the warranty.
Function
The PondECO Plus E is an electronic pond pump for use with filters, skimmers, waterfalls, and water ornaments.
Run Dry Protection
The pump is equipped with a dry-running safety device, crucial for inline use. If there is no water flow for 10 seconds, the pump will automatically stop and restart after 10 seconds. This cycle repeats 5 times. If water flow is still absent, the pump stops completely. To restart, ensure water supply is restored, unplug the device for 60 seconds, and plug it back in.
Thermal Overload Protection
The pump has thermal overload protection. If the motor overheats, the pump switches off automatically. After a cooling down period of 15 to 20 minutes, it will automatically switch on again. To prevent damage, investigate and resolve the cause of overheating. Damage caused by overheating is not covered by the warranty.
Installation
Pond Installation
The PondECO E pump is suitable for pond hoses with diameters of 25, 32, 40 mm, or 40, 50 mm. Cut the multi-step hose connector to the desired diameter and fasten it onto the pump. Connect the pond hose to the connector using a hose clamp (not included).
Preferably install the pump in the deepest part of the pond (max. 2-metre depth), or at least 20 cm below the water surface. Ensure the pump stands horizontally and firmly on a flat surface to prevent it from falling over. Plug the pump into the socket and ensure there is a drip loop in the cord. Make sure no one can trip over the cord and that the cord cannot be damaged.
Inline Installation
For inline use, the pump section must be removed from the housing. Open the housing by pressing the latches at the front and back to release the upper shell. Remove the bracket over the pump by unscrewing the 2 screws and take out the pump. The inlet is at the front (hose connector not supplied), and the outlet is at the top (for the supplied hose connector).
Cut the hose connectors to the desired diameter and fasten them to the pump. Connect the pond hoses to the hose connectors using hose clamps (not included). Install the pump horizontally and firmly on a flat surface outside the pond. Ensure it cannot tip over; secure with screws if necessary. Plug the pump into the socket and ensure there is a drip loop in the cord. Make sure no one can trip over the cord and that the cord cannot be damaged.
Maintenance
The pump should be cleaned regularly (minimum twice a year) for trouble-free operation. Scale deposits can cause the pump to seize. Failures due to dirty pumps or scale build-up caused by improper maintenance are not covered by warranty.
Always disconnect the power supply before performing any maintenance!
- Disconnect the pump from the pond hose and rinse the housing under a tap or garden hose.
- For proper cleaning and descaling, use SuperFish Pump & UVC Clean (Art. 07070500), available from your dealer. Mix the cleaner with clean tap water in a large bucket according to bottle instructions. Immerse the pump for 24 hours.
- Remove the pump from the bucket and let it drain before disassembling.
- Open the housing by pressing the latches at the front and back. Remove the bracket over the pump by unscrewing 2 screws.
- Dismantle the rotor housing by loosening the 4 screws on the front of the pump and remove the rotor.
- Brush and clean all parts and the housing thoroughly. Rinse with clean tap water and reassemble.
- Depending on usage, the rotor and rotor housing may wear out or get damaged; this is normal. Replacement parts are available from your dealer.
- NOTICE! During frost periods, remove the pump from the pond. Clean, dry, and store the pump frost-free.
Recycling
This symbol indicates that this product should not be disposed of with normal household waste. It must be handed in at an official collection centre (e.g., HWRC) or returned to the dealer when purchasing a similar new product. Follow your country's applicable rules for separate collection of electrical and electronic products. Separate collection and recycling are better for the environment, public health, and waste reduction.
Warranty
A 2-year manufacturer's warranty covers material and construction defects. Devices must be returned complete with all components and an official proof of purchase confirming the purchase date for any warranty claims. Incomplete devices or those without proof of purchase are not eligible. After receipt and inspection, SuperFish will determine if the device will be repaired or replaced. The remaining warranty period applies to repaired or replaced devices. Carefully read installation, use, and maintenance instructions. Damage due to incorrect use, contamination, lack of cleaning, wear and damage to the rotor, or damage to the cord are not covered by the warranty.
Always keep the proof of purchase; without it, the warranty is void!
Pick-up & Replace Warranty
This PondECO Plus E/RC pump includes a unique 2-year warranty with a 48-hour on-site Pick-up and Replace service. In case of a defect, the pump is picked up within 48 hours and immediately replaced free of charge with a new one (Monday-Friday, no weekend deliveries). This is subject to proper use and maintenance (regularly descaled and cleaned, cord and rotor not damaged).
To qualify for the 48-hour Pick-Up & Replace Warranty, you must register within 1 month of purchase by filling out the enclosed registration form and returning it with a copy of the purchase receipt to Aquadistri. Failure to register within the specified period means the 48-hour warranty will not apply, and the standard warranty will be valid. For warranty claims, contact your dealer.
The Pick-Up & Replace Warranty is applicable only in the Netherlands, Belgium, Luxembourg, Germany, France, and the United Kingdom. For residents of other countries, the normal warranty applies, requiring contact with the dealer where the pump was purchased.
Technical Specifications
PondECO Plus E | 3500 | 5000 | 8000 | 10000 | 12000 | 15000 | 20000 |
---|---|---|---|---|---|---|---|
Pump capacity | 3,500 l/h | 5,000 l/h | 7,800 l/h | 9,200 l/h | 11,200 l/h | 15,000 l/h | 19,500 l/h |
Head | 2.0 m | 3.0 m | 4.2 m | 5.8 m | 6.0 m | 6.5 m | 6.0 m |
Power | 14 Watt | 22 Watt | 41 Watt | 68 Watt | 85 Watt | 130 Watt | 150 Watt |
Hose connector Ø | 25/32/40 mm | 40/50 mm |
Spare Parts (Art. No.)
Model | 3500 | 5000 | 8000 | 10000 | 12000 | 15000 | 20000 |
---|---|---|---|---|---|---|---|
Rotor | 07070430 | 07070435 | 07070440 | 07070443 | 07070445 | 07070450 | 07070505 |
Rotor housing | 07070475 | 07070476 | 07070477 | 07070478 | 07070480 | 07070509 | |
Hose connector (OUTLET) | 07070485 | 07070487 | 07070492 | 07070511 | |||
Hose connector (INLET) | 07070485 | 07070487 | 07070487 | 07070511 |