Aigostar LED Sensor Slim Flood Light Instruction Manual
Product Overview
This document provides comprehensive instructions for the Aigostar LED Sensor Slim Flood Light. It details installation, operation, specifications, and troubleshooting.
Installation Diagrams
The installation process is illustrated through several diagrams:
- Diagram A: Shows the flood light and mounting bracket.
- Diagram B: Illustrates loosening bolts on the bracket.
- Diagram C: Depicts adjusting the flood light's angle.
- Diagram D: Shows tightening the bracket bolts.
- Diagram E: Demonstrates connecting the wiring.
Available Colors: The flood light is available in Brown (ES: Marrón, FR: Brun, DE: Braun, ES: Marrón, PL: Brązowy, IT: Marrone, PT: Castanho), Blue (ES: Azul, FR: Bleu, NL: Blauw, PT: Azul, PL: Niebieski, IT: Blu), and Yellow-green (ES: Amarillo/Verde, PL: Żółto-zielony, FR: Vert/Jaune, IT: giallo/Verde, PT: Amarelo verde).
Ground Connection: A ground connection symbol (⏚) is indicated.
Installation Method
The installation method is described in multiple languages:
- English: Installation method
- Spanish: Método de Instalación
- Polish: Sposób montażu
- Italian: Metodo di installazione
- German: Einbau
- Dutch: Installatie methode
- French: Méthode d' installation
- Portuguese: Método de instalação
Sensor Functionality & Controls
The sensor offers adjustable features for optimal performance:
- Sensitivity: Adjustable sensitivity is available, with options for "Good sensitivity" (ES: Mayor sensibilidad, PL: Dobra czułość, IT: buona sensibilità, DE: Gute Empfindlichkeit, NL: Goede gevoeligheid, FR: Bonne sensibilité, PT: Boa sensividade) and "Poor sensitivity" (ES: Menor sensibilidad, PL: Słaba czułość, IT: scarsa sensibilità, DE: geringe Empfindlichkeit, NL: Slechte gevoeligheid, FR: Sensibilité faible, PT: Pouca sensividade).
- Day/Night Operation: The sensor can identify day and night. Users can adjust the ambient light threshold. It operates continuously when set to the "sun" (max) position and only in low light (<3 LUX) when set to the "moon" (min) position.
- Adjustable SENS: The detection distance can be adjusted from 3m (low sensitivity) to 10m (high sensitivity), suitable for various room sizes.
- Time Delay: The time delay is continuously updated. If new motion is detected within the initial delay period, the timer resets.
Controls:
- TIME: Adjusts how long the light stays on after motion is detected (minimum to maximum).
- SENS: Adjusts the detection sensitivity or range (minimum (-) to maximum (+)).
- LUX: Adjusts the ambient light threshold for activation (minimum ? to maximum ☀️).
Specifications
Specification | 10W | 20W | 30W | 50W | 100W |
---|---|---|---|---|---|
Power(W) | 10W | 20W | 30W | 50W | 100W |
ERP certificate type (4000K) | FL01FN-10/840 | FL02FN-20/840 | FL03FN-30/840 | FL05FN-50/840 | FL10FN-100/840 |
ERP certificate type (6500K) | FL01FN-10/865 | FL02FN-20/865 | FL03FN-30/865 | FL05FN-50/865 | FL10FN-100/865 |
CE certificate type | SH-FL01FN-10-S | SH-FL02FN-20-S | SH-FL03FN-30-S | SH-FL05FN-50-S | SH-FL10FN-100-S |
Input Voltage(AC) | AC 220-240V | ||||
Input Current(mA) | 45mA | 90mA | 134mA | 219mA | 500mA |
Power Factor | > 0.8 | > 0.9 | > 0.9 | > 0.9 | > 0.9 |
Color Temperature(K) | 4000K/6500K | ||||
Energy efficiency class | F | ||||
Luminous Flux(Lm) | 950 | 2050 | 3160 | 5400 | 10950 |
CRI(Ra) | ≥80 |
Tools Required
- Adjustable spanner.
- May require parts of the power cable.
Important Notices & Warnings
- Outdoor Installation: A waterproof junction box is required for outdoor installations.
- Cable Integrity: The external flexible cable or cord of this luminaire cannot be replaced. If the cord is damaged, the luminaire must be destroyed.
- LED Source: The product contains a non-replaceable LED light source. The entire lamp must be replaced when the light source reaches its end of life.
- Energy Efficiency: This product contains a light source of energy efficiency class <F> (EU) 2019/2015.
- Wiring: Connection leads must be connected to the screw terminal block, which should be placed in a reinforced insulation terminal box.
- IP Rating: For outdoor use, the terminal box must pass IP65 testing.
- Electrical Safety: Pay attention to the rated voltage and connecting capacity of the terminal block when connecting the power cord.
- Mounting Height: The LED sensor slim flood light should be installed on the ground, wall, or a fixed bracket. The installation height should not exceed 9 meters.
- Switch Connection: The switch must be connected to the live wire.
Installation Instructions
- Install the brackets.
- Loosen the bolts on both sides of the bracket.
- Adjust the angle of the flood light.
- Tighten the bolts on both sides of the bracket.
- Connect the wiring of the flood light.
- Turn on the power to ensure the light is working.
Warranty
This product is warranted against manufacturing defects only for a period of two years from the date of purchase. This warranty does not cover damage caused by incorrect user installation or abnormal wear and tear. The company provides no warranty against damage to any surface due to incorrect removal or application of this product.
Infrared Motion Sensor - Instructions for Use
Functions
- Day/Night Operation: The user can adjust the ambient light sensitivity. The sensor can operate day and night when set to the "sun" (max) position. It can operate in ambient light less than 3 LUX when set to the "moon" (min) position. Refer to the test pattern for adjustment details.
- Adjustable Sensitivity (SENS): Sensitivity can be adjusted according to the installation location. Low sensitivity detection distance can be 3m, while high sensitivity can reach 10m, fitting larger rooms.
- Continuous Time Delay: The time delay is continuously updated. If a second induction signal is received within the first induction period, the timer will restart from that moment.
Installation Advice
As the detector is sensitive to temperature changes, avoid the following situations:
- Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors.
- Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, lights, etc. Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall plants, etc.
Test Procedure
- Turn the SENS knob clockwise to maximum (+). Turn the LUX knob clockwise to maximum (☀️). Turn the TIME knob counter-clockwise to minimum (-).
- Switch on the power. The sensor and connected lamp will have no signal initially. After a 30-second warm-up period, the sensor will begin to function. If the sensor receives an induction signal, the lamp will turn on. If no further induction signal is received, the load should stop working within 10sec ± 3sec, and the lamp will turn off.
- Turn the LUX knob counter-clockwise to minimum (?). If the ambient light is greater than 3 LUX, the sensor will not work, and the lamp will not turn on. If the ambient light is less than 3 LUX (darkness), the sensor will work. If no induction signal is detected, the sensor should stop working within 10sec ± 3sec.
Note: When testing in daylight, please turn the LUX knob to the "SUN" position, otherwise the sensor lamp may not work!
Problems and Solutions
1. The load does not work:
- Check if the power source and load connection are correct.
- Check if the load is functional.
- Check if the working light settings correspond to the ambient light.
2. Sensitivity is poor:
- Check if there are any obstructions in front of the detector that affect signal reception.
- Check if the ambient temperature is too high.
- Check if the induction signal source is within the detection field.
- Check if the installation height corresponds to the required height in the instructions.
- Check if the motion orientation is correct.
3. The sensor cannot automatically shut off the load:
- Check if there is a continuous signal in the detection field.
- Check if the time delay is set to the maximum position.
- Check if the power corresponds to the specifications.