Morris MPH-10331 Air to Water Heat Pump - Technical Data
This document provides the technical specifications for the Morris MPH-10331 Air to Water Heat Pump.
General Information
Model(s): | MPH-10331 |
Air-to-water heat pump: | yes |
Water-to-water heat pump: | no |
Brine-to-water heat pump: | no |
Low-temperature heat pump: | no |
Equipped with a supplementary heater: | yes |
Heat pump combination heater: | no |
Declared climate condition: | average / warmer / colder |
Parameters are declared for low-temperature application. |
Technical Parameters - Heating
Item | Symbol | Value | Unit | Item | Symbol | Value | Unit |
---|---|---|---|---|---|---|---|
Rated heat output (*) | Prated | 9 | kW | Seasonal space heating energy efficiency | ηs | 199 | % |
Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature Tj | Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature Tj | ||||||
Tj = -7°C | Pdh | 8.0 | kW | Tj = -7°C | COPd | 2.99 | - |
Tj = + 2°C | Pdh | 5.0 | kW | Tj = + 2°C | COP | 4.97 | - |
Tj = + 7°C | Pdh | 3.1 | kW | Tj = + 7°C | COP | 6.78 | - |
Tj = + 12°C | Pdh | 2.0 | kW | Tj = + 12°C | COP | 9.10 | - |
Tj = bivalent temperature | Pdh | 8.0 | kW | Tj = bivalent temperature | COP | 2.99 | - |
Tj = operation limit temperature | Pdh | 7.3 | kW | Tj = operation limit temperature | COPd | 2.72 | - |
For air-to-water heat pumps: Tj = – 15°C (if TOL < -20°C) | Pdh | N/A | kW | For air-to-water heat pumps: Tj = – 15°C (if TOL < -20°C) | COPd | N/A | - |
Bivalent temperature | Tbiv | -7 | °C | For air-to-water heat pumps: Operation limit temperature | TOL | -10 | °C |
Cycling interval capacity for heating | Pcych | N/A | kW | Cycling interval efficiency | COPcyc | N/A | - |
Degradation co-efficient (**) | Cdh | 0.9 | - | Heating water operating limit temperature | WTOL | 65 | °C |
Power Consumption and Other Items
Item | Symbol | Value | Unit | Item | Symbol | Value | Unit |
---|---|---|---|---|---|---|---|
Power consumption in modes other than active mode | Supplementary heater | ||||||
Off mode | POFF | 0.014 | kW | Rated heat output (**) | Psup | 1.7 | kW |
Thermostat-off mode | PTO | 0.024 | kW | Type of energy input | Electric | ||
Standby mode | PSB | 0.014 | kW | ||||
Crankcase heater mode | PCK | 0.000 | kW | ||||
Other items | |||||||
Capacity control | variable | For air-to-water heat pumps: Rated air flow rate, outdoors | 4500 | m³/h | |||
Sound power level, indoors/ outdoors | LWA | -/61 | dB | For water- or brine-to-water heat pumps: Rated brine or water flow rate, outdoor heat exchanger | - | N/A | m³/h |
Annual energy consumption | QHE | 3702 | kWh | For heat pump combination heater: | |||
Declared load profile | Water heating energy efficiency | ηwh | N/A | % | |||
Daily electricity consumption | Qelec | N/A | kWh | Daily fuel consumption | Qfuel | N/A | kWh |
Annual electricity consumption | AEC | N/A | kWh | Annual fuel consumption | AFC | N/A | GJ |
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj). (**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9. |
Technical Parameters - Cooling
Item | Symbol | Value | Unit | Item | Symbol | Value | Unit |
---|---|---|---|---|---|---|---|
Model(s): | MPH-10331 | ||||||
Outdoor side heat exchanger of chiller: | Air to water | ||||||
Indoor side heat exchanger chiller: | Water | ||||||
Type: | compressor driven vapour compression | ||||||
Driver of compressor: | Electric motor | ||||||
Rated cooling capacity | Prated,c | 8 | kW | Seasonal space cooling energy efficiency | ηs,c | 212 | % |
Declared capacity for cooling for part load at given outdoor temperature Tj | Declared energy efficiency ratio for cooling for part load at given outdoor temperature Tj | ||||||
Tj = + 35°C | Pdc | 8.1 | kW | Tj = +35°C | EERd | 3.16 | - |
Tj = + 30°C | Pdc | 6.6 | kW | Tj = + 30°C | EERd | 4.38 | - |
Tj = + 25°C | Pdc | 4.3 | kW | Tj = + 25°C | EERd | 6.18 | - |
Tj = + 20°C | Pdc | 1.9 | kW | Tj = + 20°C | EERd | 8.17 | - |
Degradation co-efficient of chiller (*) | Cdc | 0.9 | - | Power consumption in modes other than "active mode" | |||
Off mode | POFF | 0.014 | kW | Crankcase heater mode | PCK | 0.000 | kW |
Thermostat-off mode | PTO | 0.024 | kW | Standby mode | PSB | 0.014 | kW |
Other items | |||||||
Capacity control | variable | For air-to-water comfort chillers: air flow rate, outdoor measured | - | 4500 | m³/h | ||
Sound power level, indoors/ outdoors | LWA | -/61 | dB | For water/brine-to-water chillers: Rated brine or water flow rate, outdoor side heat exchanger | - | N/A | m³/h |
Emissions of nitrogen oxide (if applicable) | NOx(**) | mg/kWh input GCV | GWP of the refrigerant | 675 | kg CO2 eq (100 years) | ||
Standard rating conditions used | Low temperature application | ||||||
(*) If Cdc is not determined by measurement then the default degradation coefficient of chillers shall be 0.9. (**) From 26 September 2018. |