Morris MPH-12363 Air to Water Heat Pump
Technical Data
General Information
Model(s): | MPH-12363 |
Air-to-water heat pump: | yes |
Water-to-water heat pump: | no |
Brine-to-water heat pump: | no |
Low-temperature heat pump: | no |
Equipped with a supplementary heater: | yes (6kW) |
Heat pump combination heater: | no |
Declared climate condition: | average, warmer, colder |
Parameters are declared for low-temperature application. |
Technical Parameters - Heating
Item | Symbol | Value | Unit | Item | Symbol | Value | Unit |
---|---|---|---|---|---|---|---|
Rated heat output (*) | Prated | 10-12 | kW | Seasonal space heating energy efficiency | ηs | 116-253 | % |
Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature Tj | Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature Tj | ||||||
Tj = -7°C | Pdh | 6.7-10.7 | kW | Tj = -7°C | COP | 2.58-3.51 | |
Tj = + 2°C | Pdh | 4.0-12.1 | kW | Tj = + 2°C | COP | 3.68-4.53 | |
Tj = + 7°C | Pdh | 2.9-8.0 | kW | Tj = + 7°C | COP | 4.57-6.65 | |
Tj = + 12°C | Pdh | 3.3-4.3 | kW | Tj = + 12°C | COP | 6.59-8.92 | |
Tj = bivalent temperature | Pdh | 7.2-10.7 | kW | Tj = bivalent temperature | COP | 3.85-5.64 | |
Tj = operation limit temperature | Pdh | 4.7-11.4 | kW | Tj = operation limit temperature | COP | 1.21-2.90 | |
For air-to-water heat pumps: Tj = – 15°C (if TOL < -20°C) | Pdh | N/A | kW | For air-to-water heat pumps: Tj = – 15°C (if TOL < -20°C) | COPd | N/A | |
Bivalent temperature | Tbiv | -7 to 7 | °C | For air-to-water heat pumps: Operation limit temperature | TOL | -10 to 2 | °C |
Cycling interval capacity for heating | Pcych | N/A | kW | Cycling interval efficiency | COPcych | N/A | |
Degradation co-efficient (**) | Cdh | 0.9 | - | Heating water operating limit temperature | WTOL | 65 | °C |
Power Consumption (Modes other than active mode)
Mode | Symbol | Value | Unit |
---|---|---|---|
Off mode | POFF | 0.014 | kW |
Thermostat-off mode | PTO | 0.024 | kW |
Standby mode | PSB | 0.014 | kW |
Crankcase heater mode | PSK | 0.000 | kW |
Other Items
Item | Symbol | Value | Unit | Item | Symbol | Value | Unit |
---|---|---|---|---|---|---|---|
Capacity control | variable | For air-to-water heat pumps: Rated air flow rate, outdoors | 5000 | m³/h | |||
Sound power level, indoors/ outdoors | LWA | -/64 | dB | For water- or brine-to-water heat pumps: Rated brine or water flow rate, outdoor heat exchanger | N/A | m³/h | |
Annual energy consumption | QHE | 5256-8459 | kWh | For heat pump combination heater: | |||
Declared load profile | N/A | Water heating energy efficiency | ηwh | N/A | % | ||
Daily electricity consumption | Qelec | N/A | kWh | Daily fuel consumption | Qfuel | N/A | kWh |
Annual electricity consumption | AEC | N/A | kWh | Annual fuel consumption | AFC | N/A | GJ |
Current details
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9.
Information requirements for comfort chillers
Item | Symbol | Value | Unit | Item | Symbol | Value | Unit |
---|---|---|---|---|---|---|---|
Model(s): | MPH-12363 | ||||||
Outdoor side heat exchanger of chiller | Air to water | Indoor side heat exchanger chiller | Water | ||||
Type: | compressor driven vapour compression | Driver of compressor | Electric motor | ||||
Rated cooling capacity | Prated,c | 12 | kW | Seasonal space cooling energy efficiency | ηs,c | 119-276 | % |
Declared capacity for cooling for part load at given outdoor temperature Tj | Declared energy efficiency ratio for cooling for part load at given outdoor temperature Tj | ||||||
Tj = + 35°C | Pdc | 11.7-12.0 | kW | Tj = +35°C | EERd | 2.64-3.91 | - |
Tj = + 30°C | Pdc | 8.8-9.3 | kW | Tj = + 30°C | EERd | 4.09-5.67 | - |
Tj = + 25°C | Pdc | 5.9-5.7 | kW | Tj = + 25°C | EERd | 5.58-7.98 | - |
Tj = + 20°C | Pdc | 4.1-5.1 | kW | Tj = + 20°C | EERd | 8.01-11.37 | - |
Degradation co-efficient of chiller (*) | Cdc | 0.9 | - | Power consumption in modes other than "active mode" | |||
Off mode | POFF | 0.014 | kW | Crankcase heater mode | PSK | 0.000 | kW |
Thermostat-off mode | PTO | 0.024 | kW | Standby mode | PSB | 0.014 | kW |
Capacity control | variable | For air-to-water comfort chillers: air flow rate, outdoor measured | 5000 | m³/h | |||
Sound power level, indoors/outdoors | LWA | -/64 | dB | For water/brine-to-water chillers: Rated brine or water flow rate, outdoor side heat exchanger | N/A | m³/h | |
Emissions of nitrogen oxide (if applicable) | NOx(**) | mg/kWh input GCV | GWP of the refrigerant | 675 kg CO2 eq (100 years) | |||
Standard rating conditions used | Low temperature application, Medium temperature application |
Contact Details
Kalliopi Karyda & Co., LP
87A, 17is Noemvriou str.
55535, Pylea, Greece
Tel. 2316 006600
www.morris.gr
Καλλιόπη Καρύδα & ΣΙΑ Ε.Ε
17ης Νοεμβρίου 87Α,
55535, Πυλαία, Ελλάδα
Τηλ. 2316 006600
www.morris.gr