MEAN WELL FDL-65 Series 65W Constant Current Mode LED Driver
Features
- Constant Current mode output
- Metal housing design
- Built-in active PFC function
- No load power consumption < 0.5W
- IP65 rating for indoor or outdoor installations
- Output current adjustable via potentiometer
- 3 years warranty
Description
The FDL-65 series is a 65W LED AC/DC LED power supply featuring constant current mode output, targeting LED flood lighting applications. It operates from 180~295VAC and offers models for voltages up to 42V (1550mA model) and 36V (1800mA model). With high efficiency up to 90% and a fanless design, it operates from -40°C to +90°C case temperature under free air convection. The metal housing and IP65 ingress protection level make it suitable for indoor and outdoor applications. The FDL-65 is equipped with an output current adjustable function for design flexibility.
Model Encoding
The model encoding follows the pattern: FDL - 65 - [Rated Output Current (1550/1800mA)].
Specifications
Specification | FDL-65-1550 | FDL-65-1800 |
---|---|---|
RATED CURRENT | 1550mA | 1800mA |
RATED POWER | 65.1W | 64.8W |
CONSTANT CURRENT REGION | 25.2 ~ 42V | 21.6 ~ 36V |
OPEN CIRCUIT VOLTAGE (max.) | 50V | 45V |
CURRENT ADJ. RANGE | 0.77-1.55A | 0.9~1.8A |
CURRENT TOLERANCE | ±5.0% | ±5.0% |
SET UP TIME | 500ms/230VAC | 500ms/230VAC |
VOLTAGE RANGE | 180~295VAC | 180~295VAC |
FREQUENCY RANGE | 47~63Hz | 47~63Hz |
POWER FACTOR (Typ.) | PF≥0.95/230VAC, PF≥0.90/277VAC@full load | PF≥0.95/230VAC, PF≥0.90/277VAC@full load |
TOTAL HARMONIC DISTORTION | THD<20%(@load≥60%/230VAC; @load≥75%/277VAC) | THD<20%(@load≥60%/230VAC; @load≥75%/277VAC) |
EFFICIENCY (Typ.) | 90% | 90% |
AC CURRENT (Typ.) | 0.48A/230VAC | 0.39A/277VAC |
INRUSH CURRENT (Typ.) | COLD START 11A(twidth=35µs measured at 50% Ipeak)/230VAC | COLD START 11A(twidth=35µs measured at 50% Ipeak)/230VAC |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 26 units (type B) / 26 units (type C) at 230VAC | 26 units (type B) / 26 units (type C) at 230VAC |
LEAKAGE CURRENT | <0.75mA/277VAC | <0.75mA/277VAC |
NO LOAD POWER CONSUMPTION | <0.5W | <0.5W |
SHORT CIRCUIT PROTECTION | Hiccup mode, recovers automatically after fault condition is removed | Hiccup mode, recovers automatically after fault condition is removed |
OVER VOLTAGE PROTECTION | 46~56V | 40~48V |
OVER TEMPERATURE PROTECTION | Shut down o/p voltage, re-power on to recover | Shut down o/p voltage, re-power on to recover |
WORKING TEMP. | Tcase=-40~+90°C | Tcase=-40~+90°C |
MAX. CASE TEMP. | Tcase=+90°C | Tcase=+90°C |
WORKING HUMIDITY | 20~95% RH non-condensing | 20~95% RH non-condensing |
STORAGE TEMP., HUMIDITY | -40~+80°C, 10~95% RH | -40~+80°C, 10~95% RH |
TEMP. COEFFICIENT | ±0.03%/°C (0~60°C) | ±0.03%/°C (0~60°C) |
VIBRATION | 10~500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | 10~500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes |
SAFETY STANDARDS | LVD BS EN/EN61347-1, BS EN/EN61347-2-13 Independent, GB19510.1, GB19510.14, EAC TP TC 004, IP65 approved | LVD BS EN/EN61347-1, BS EN/EN61347-2-13 Independent, GB19510.1, GB19510.14, EAC TP TC 004, IP65 approved |
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC, I/P-FG:2KVAC, O/P-FG:1.5KVAC | I/P-O/P:3.75KVAC, I/P-FG:2KVAC, O/P-FG:1.5KVAC |
ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25°C/70% RH | I/P-O/P:100M Ohms / 500VDC / 25°C/70% RH |
EMC EMISSION | Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (load≥60%) ; BS EN/EN61000-3-3, GB17743, GB17625.1, EAC TP TC 020 | Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (load≥60%) ; BS EN/EN61000-3-3, GB17743, GB17625.1, EAC TP TC 020 |
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity: Line-Earth: 4KV, Line-Line:2KV), EAC TP TC 020 | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity: Line-Earth: 4KV, Line-Line:2KV), EAC TP TC 020 |
MTBF | 5409.5K hrs min. Telcordia SR-332 (Bellcore) | 596.6Khrs min. MIL-HDBK-217F (25°C) |
DIMENSION | 151*53*31.5mm (L*W*H) | 151*53*31.5mm (L*W*H) |
PACKING | 0.441Kg; 24pcs / 11.6Kg / 0.73CUFT | 0.441Kg; 24pcs / 11.6Kg / 0.73CUFT |
Diagrams and Characteristics
Block Diagram
The block diagram illustrates the internal components and signal flow of the FDL-65 series LED driver. It includes an EMI filter and rectifiers for input processing, followed by power switching and a PWM & PFC control unit. The output stage consists of rectifiers and a filter, with a detection circuit feeding back to the control unit. Protection circuits such as Over Voltage Protection (OVP), Over Temperature Protection (OTP), and Over Load Protection (OLP) are integrated. The unit also features Case Ground for EMC compliance.
Driving Methods of LED Module
This series operates in constant current mode to directly drive LEDs. The graph shows the 'Constant Current area' and 'Hiccup Protection' region. In the constant current region, the output voltage is dependent on the configuration of the end system.
Output Load vs Temperature
Two graphs illustrate the output load capacity relative to temperature. The first graph shows Load (%) versus Ambient Temperature (Ta in °C), indicating the operating range from -40°C to +70°C. The second graph shows Load (%) versus Case Temperature (Tcase in °C), with an operating range from -40°C to +90°C.
Static Characteristic
This graph displays the relationship between Input Voltage (V) and Load (%) at 60Hz. The FDL-65 series operates within an input voltage range of approximately 180V to 295V.
Power Factor (PF) Characteristic
The power factor is shown as a function of Load (%) at a case temperature of 80°C. Separate curves are provided for 230V and 277V input voltages, demonstrating a high power factor across the load range.
Total Harmonic Distortion (THD)
This graph illustrates the Total Harmonic Distortion (THD) as a function of Load (%) for the 1800mA model at a case temperature of 80°C. Curves are shown for 230VAC and 277VAC input, indicating THD is generally below 20% for loads above 60% (230VAC) or 75% (277VAC).
Efficiency vs Load
The efficiency of the FDL-65 series is presented as a function of Load (%) at a case temperature of 80°C. Curves for 230V and 277V input show that the efficiency reaches up to 90% in field applications.
Mechanical Specification
The mechanical specifications include the overall dimensions: 151mm (Length) x 53mm (Width) x 31.5mm (Height). Input connections are AC/N (Blue) and AC/L (Brown) using H05RN 1.0mm²*2C cables. Output connections are -V (Blue) and +V (Brown) also using H05RN 1.0mm²*2C cables. Mounting holes are indicated. The note specifies connecting the case to FG (Frame Ground) for complete EMC deliverance. The product is IP65 rated.
Installation Manual
For detailed installation instructions, please refer to the MEAN WELL website: http://www.meanwell.com/manual.html
Product Liability Disclaimer
For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx