JAPAN SPECIFIED RADIO TEST REPORT

Report No.: 18220WC20100602

General Information

1.1. Client Information

Applicant: Shenzhen Proscenic Technology Company Limited

Address: Floor 8, Block A, building 5, Tusincere Park, Longcheng street, Longgang district, Shenzhen City, China

1.2. Description of Device (EUT)

Product Name: Cordless Wet Dry Vacuum Cleaner

Model No.: F20, F21, F22, F20 pro, F21 pro, F20A, F21A, F20Steam, F21Steam, AC1, AC2, AC3, AC1 PRO, AC2 PRO, AC1compact, AC2compact, AC1Steam, AC2Steam, AC1combo

(Note: All samples are the same except the model number, so we prepare "F20" for test only.)

Trade Mark: PROSCENIC, Oltenic

Test Power Supply: AC 100V, 60Hz for Adapter

Test Sample No.: 1-2-1 (Normal Sample), 1-2-2(Engineering Sample)

Product Description:

  • Operation Frequency: BLE: 2402~2480MHz; WiFi 2.4G: 2412~2472MHz for 802.11b/g/n20
  • Number of Channel: BLE: 40 Channels; WiFi 2.4G: 13 Channels for 802.11b/g/n20
  • Modulation Type: BLE: GFSK; WiFi 2.4G: CCK, DQPSK, DBPSK for DSSS; 64QAM, 16QAM, QPSK, BPSK for OFDM
  • Antenna Type: BLE & WiFi 2.4G: PCB Antenna
  • Antenna Gain(Peak): BLE/ WiFi 2.4G: 2.5 dBi (Provided by customer)
  • Rated output Power: BLE: 10 mW Max.; 802.11b: 3 mW/MHz Max.; 802.11g: 3 mW/MHz Max; 802.11n20: 3 mW/MHz Max.

1.3. Auxiliary Equipment Used During Test

N/A

1.4. Description of Test Modes

The EUT has been tested under operating condition. Software used to control the EUT for staying in continuous transmitting and receiving mode is programmed.

  • IEEE802.11b: Channel 1(2412MHz), Channel 7(2442MHz) and Channel 13(2472MHz) with 11Mbps Worst data rate (worst case) are chosen for the final testing.
  • IEEE802.11g: Channel 1(2412MHz), Channel 7(2442MHz) and Channel 13(2472MHz) with 54Mbps data rate (the worst case) are chosen for the final testing.
  • IEEE802.11n (HT20): Channel 1(2412MHz), Channel7(2442MHz) and Channel 13(2472MHz) with 65Mbps Worst data rate (worst case) are chosen for the final testing.

This device have more than 1 subcarrier in 1MHz, compliance with the requirement.

1.5. Test Conditions

Normal Test Conditions Extreme Test Conditions
Temperature 15°C - 35°C -10°C ~ 45°C
Relative Humidity 20% - 75% N/A
Pressure Range 86-106kPa N/A

1.6. Test Voltage

Voltage Fluctuation Test Normal Voltage High Voltage +10% of Normal Voltage Low Voltage -10% of Normal Voltage
Input To EUT AC 100V AC 110V AC 90V
Output To RF Module DC 3.30V DC 3.30V DC 3.30V
Voltage Variation (%) -- 0.00% 0.00%

Note: Voltage Variation (%) = (Output High or Low Voltage - Output Normal Voltage)/ Output Normal Voltage* 100

For extreme voltage test, we have tested the relationship between the external power supply and RF IC power supply. Base on the test results, only the normal voltage was selected to perform all items.

1.7. Test Configuration

Diagram Description: The test setup includes a Temperature Chamber, an Antenna, an EUT (Equipment Under Test), a Spectrum Analyzer, an AC Power Supply, and a connection between the Antenna and EUT, and between the EUT and Spectrum Analyzer.

1.8. Test Equipment List

Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval
1. Artificial Power Network CYBERTEK EM5040DT E215040DT001 Jul 05, 2021 1 Year
2. EMI Test Receiver Rohde & Schwarz ESCI 100627 Oct. 22, 2021 1 Year
3. EMI Test Receiver Rohde & Schwarz ESR26 101481 Oct. 22, 2021 1 Year
4. RF Switching Unit Compliance Direction RSU-ME 38303 Oct. 22, 2021 1 Year
5. MAX Spectrum Analysis Agilent N9020A MY51170037 Oct. 22, 2021 1 Year
6. Preamplifier SKET Electronic BK1G18G30D KD17503 Oct. 22, 2021 1 Year
7. Double Ridged Horn Antenna Instruments corporation GTH-0118 351600 Oct. 22, 2021 2 Year
8. Bilog Broadband Antenna Schwarzbeck VULB9163 VULB 9163-289 Oct. 22, 2021 2 Year
9. Loop Antenna Schwarzbeck FMZB1519B 00053 Oct. 22, 2021 2 Year
10. Horn Antenna A-INFO LB-180400-KF J211060628 Oct. 22, 2021 1 Year
11. Pre-amplifier SONOMA 310N 186860 Oct. 22, 2021 1 Year
12. EMI Test Software EZ-EMC SHURPLE N/A N/A N/A N/A
13. RF Test Control System YIHENG YH3000 2017430 Oct. 22, 2021 1 Year
14. Power Sensor DAER RPR3006W 15100041SN045 Oct. 22, 2021 1 Year
15. Power Sensor DAER RPR3006W 15100041SN046 Oct. 22, 2021 1 Year
16. MXA Spectrum Analysis KEYSIGHT N9020A MY53280032 Oct. 22, 2021 1 Year
17. MXG RF Vector Signal Generator Agilent N5182A MY48180656 Oct. 22, 2021 1 Year
18. Signal Generator Agilent E4421B MY41000743 Oct. 22, 2021 1 Year
19. DC Power Supply IVYTECH IV3605 1804D360510 Oct. 22, 2021 1 Year
20. Constant Temperature Humidity Chamber ZHONGJIAN ZJ-KHWS80B N/A Oct. 22, 2021 1 Year

1.9. Description of Test Facility

The test facility is recognized, certified, or accredited by the following organizations:

FCC-Registration No.: 184111

Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration No. 184111.

ISED-Registration No.: 8058A

Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registered and fully described in a report filed with the (ISED) Innovation, Science and Economic Development Canada. The acceptance letter from the ISED is maintained in our files. Registration 8058A.

Test Location

Shenzhen Anbotek Compliance Laboratory Limited.

1/F, Building D, Sogood Science and Technology Park, Sanwei Community, Hangcheng Street, Bao'an District, Shenzhen, Guangdong, China.518102

2. Summary Of Test Results

Test Items Subclause Required Results
General Provisions
Frequency Tolerance 5 Yes Complies
Occupied Bandwidth 6 Yes Complies
Spurious Emissions 7 Yes Complies
Transmitting equipment
Antenna power 14 Yes Complies
Frequency stabilization 15 Yes Complies
Transmitter antenna
Type, configuration, etc. of transmitting antenna 20 Yes Complies
Directional pattern of transmitting antenna 22 Yes Complies
Receiving equipment
Spurious emission of receiver 24 Yes Complies
Refer to all articles for transmitter antenna 26 Yes Complies
Operating frequency 2400-2483.5MHz
High Frequency/modulation section cannot be opened easily 49.20(1); a Yes Complies
Communication method 49.20(1); b Yes Complies
Modulation method 49.20(1); c Yes Complies
Spread spectrum method 49.20(1); d Yes Complies
Antenna power 49.20(1); e Yes Complies
Absolute gain of transmitting antenna 49.20(1); f(1) N/A N/A
Angular width of principal radiation (AWPR) 49.20(1); f(2) N/A N/A
Number of carriers within 1 MHz bandwidth in OFDM 49.20(1); g Yes Complies
Diffusion bandwidth 49.20(1); h Yes Complies
Spreading factor 49.20(1); i Yes Complies
Frequency retention time (FH employed) 49.20(1); j Yes Complies
EIRP 49.20(1); N/A N/A
Carrier sensing function -- Yes Complies
Interference prevention function -- Yes Complies

Note: "N/A" denotes test is not applicable in this Test Report.

3. Frequency Tolerance Test

3.1. Test Limit

±50 ppm

3.2. Test Equipment

Same as 1.7.

3.3. Test Configuration

Same as 1.6.

3.4. Test Data

PASS

Please refer to Appendix A of the Appendix Test Data.

4. Occupied Bandwidth (99%) Test

4.1. Test Limit

Under all test conditions Limit
FH: 83.5 MHz
FH + DS: 83.5 MHz
FH + OFDM: 83.5MHz
OFDM, DS: 26MHz
Others: 26MHz
OFDM equipment with 40MHz channel separation: 40MHz

4.2. Test Equipment

Same as 1.7 Frequency tolerance measurement.

4.3. Test Configuration

Same as 1.6 Frequency tolerance measurement.

4.4. Test Data

PASS

Please refer to Appendix C of the Appendix Test Data.

5. Spread-Spectrum Bandwidth (90%) Test

5.1. Test Limit

Test Limit Limit
Spreading factor: ≥ 5
Spread bandwidth: ≥500KHz

5.2. Test Equipment

Same as 1.7 Frequency tolerance measurement.

5.3. Test Configuration

Same as 1.6 Frequency tolerance measurement.

5.4. Test Data

Pass

Please refer to Appendix D of the Appendix Test Data.

6. Spurious Emissions Intensity Test

6.1. Test Equipment

Same as 1.7 Frequency tolerance measurement.

6.2. Test Configuration

Same as 1.6 Frequency tolerance measurement.

6.3. Test Data

Scanning Bandwidth
30~2387MHz
2387~2400MHz
2483.5~2496.5MHz
2496.5~12500MHz.

Pass

Please refer to Appendix E of the Appendix Test Data.

7. Carrier Sense

7.1. Test Equipment

Same as 1.7 Frequency tolerance measurement.

7.2. Test Setup

Diagram Description: The test setup consists of a Standard Signal Generator, a Divider, an EUT (Equipment Under Test), and a Spectrum Analyzer. Connections are made from the Standard Signal Generator to the Divider, from the Divider to the EUT, and from the EUT to the Spectrum Analyzer.

7.3. Test Configuration

1. Set the standard signal generator as follows:

  • Carrier frequency: Center frequency of received frequency band
  • Modulation: Non-modulation
  • Output level: declared level of applicant at the antenna input part of the EUT.

2. Set the spectrum analyzer as follows:

  • Frequency: Center frequency of received frequency band
  • Span: 50MHz
  • RBW: 1MHz
  • VBW: 1MHz
  • Triggered: Free run
  • Detector mode: Positive peak

7.4. Test Measurement procedure

  1. Confirm that EUT can transmit.
  2. Set EUT into Rx Mode.
  3. Signal Generator ON
  4. Confirm that EUT don't transmit.

7.5. Test Data

Describe as acceptance (Test pass)

8. Interference Prevention Function

8.1. Test Limit

The identification code shall be 48 bits long

8.2. Test Setup

Diagram Description: The test setup includes an EUT (Equipment Under Test), a Companion Equipment, and a Notebook. The EUT is linked up with the companion equipment.

8.3. Test Configuration

  1. Set EUT under operating mode and link up with companion equipment.
  2. Check communication status between EUT and companion equipment is normal
  3. Record the max. reading.
  4. Confirm the MAC address of EUT

8.4. Test Data

Test Mode ID Code Test Results
WiFi 2.4G A1:24:1A:45:C2:2B Pass

9. Antenna Power Test

9.1. Test Equipment

Same as 1.7 Frequency tolerance measurement.

9.2. Test Setup

Diagram Description: The test setup includes a Temperature Chamber, an Antenna, an EUT (Equipment Under Test), a Power Meter, and a Variable Power Supply. Connections are made from the Variable Power Supply to the EUT, from the Antenna to the EUT, and from the EUT to the Power Meter.

9.3. Test Data

Pass

Please refer to Appendix B of the Appendix Test Data.

10. Limitation Of Collateral Emissions Of Receiver Test

10.1. Test Equipment

Same as 1.7 Frequency tolerance measurement.

10.2. Test Configuration

Same as 1.6 Frequency tolerance measurement.

10.3. Test Data

Scanning Bandwidth
30~1000MHz
1000~12500MHz

Pass

Please refer to Appendix F of the Appendix Test Data.

Appendices

APPENDIX I -- TEST SETUP PHOTOGRAPH

Reference to the test report 18220WC20100601.

APPENDIX II -- EXTERNAL PHOTOGRAPH

Reference to the test report 18220WC20100601.

APPENDIX III -- INTERNAL PHOTOGRAPH

Reference to the test report 18220WC20100601.

APPENDIX IV – Appendix Test Data

This section contains appendix test data.

PDF preview unavailable. Download the PDF instead.

210-188738 02 007 WPS 文字

Related Documents

Preview Proscenic Wash Vac F20 Cordless Wet Dry Vacuum Cleaner Owner's Manual
This owner's manual provides comprehensive instructions for the Proscenic Wash Vac F20 Cordless Wet Dry Vacuum Cleaner, covering setup, operation, maintenance, troubleshooting, and product specifications.
Preview Proscenic Wash Vac F20 Cordless Wet Dry Vacuum Cleaner User Manual
User manual for the Proscenic Wash Vac F20 cordless wet and dry vacuum cleaner, detailing operation, maintenance, troubleshooting, and specifications for smart home cleaning.
Preview Proscenic Wash Vac F20 Cordless Wet Dry Vacuum Cleaner Owner's Manual
This owner's manual provides instructions for the Proscenic Wash Vac F20 Cordless Wet Dry Vacuum Cleaner, covering safety precautions, product information, operation, maintenance, and troubleshooting.
Preview Proscenic F20 A Cordless Wet Dry Vacuum Cleaner User Manual
User manual for the Proscenic F20 A Cordless Wet Dry Vacuum Cleaner. Covers setup, operation, maintenance, and troubleshooting for optimal cleaning performance. Includes safety precautions and product specifications.
Preview Proscenic Wash Vac F20 Cordless Wet Dry Vacuum Cleaner User Manual
User manual for the Proscenic Wash Vac F20 Cordless Wet Dry Vacuum Cleaner, covering precautions, product features, usage, maintenance, troubleshooting, and specifications.
Preview Proscenic F10 Pro Cordless Wet Dry Vacuum Cleaner User Manual
Comprehensive user manual for the Proscenic F10 Pro Cordless Wet Dry Vacuum Cleaner. Learn about safety instructions, product usage, maintenance, troubleshooting, and specifications for efficient cleaning.
Preview Proscenic P10 PRO Cordless Vacuum Cleaner: Instruction Manual and User Guide
Comprehensive guide for the Proscenic P10 PRO cordless vacuum cleaner, covering safety instructions, setup, usage, maintenance, troubleshooting, and technical specifications. Learn how to operate and care for your Proscenic vacuum.
Preview Proscenic M8 PRO Robot Vacuum Cleaner Instruction Manual
User manual for the Proscenic M8 PRO robot vacuum cleaner, covering setup, operation, features, maintenance, and troubleshooting for efficient automated home cleaning.