CommScope 810010541/DB | C-006-LA-8W-M06BK/25D/C
Fiber Indoor/Outdoor Cable
Product Overview
This document details the specifications for the CommScope 810010541/DB C-006-LA-8W-M06BK/25D/C fiber optic cable. It is an indoor/outdoor cable featuring a Single Jacket and Single Armor construction with Low Smoke Zero Halogen (LSZH) properties. The cable contains 6 Singlemode fibers, conforming to G.652.D and G.657.A1 standards. It utilizes a Gel-Free, Stranded Loose Tube design, a black jacket with meter markings, and a Cca flame rating. The corrugated steel tape armor provides enhanced protection against crush and rodents.
A visual representation of the fiber optic cable shows its layered construction with a black outer jacket, corrugated steel tape armor, and internal buffer tubes containing optical fibers.
Product Classification
Regional Availability | Asia | Australia/New Zealand | EMEA | Europe | Latin America | North America |
---|---|
Portfolio | CommScope® |
Product Type | Fiber indoor/outdoor cable |
Product Series | Z-LA |
General Specifications
Armor Type | Corrugated steel |
---|---|
Cable Type | Stranded loose tube |
Construction Type | Armored |
Subunit Type | Gel-free |
Filler, quantity | 4 |
Jacket Color | Black |
Jacket Marking | Feet |
Subunit, quantity | 1 |
Fibers per Subunit, quantity | 6 |
Total Fiber Count | 6 |
Dimensions
Buffer Tube/Subunit Diameter | 2.5 mm | 0.098 in |
---|---|
Diameter Over Jacket | 13 mm | 0.512 in |
Cable Construction Diagram
A detailed cross-section diagram of the fiber optic cable illustrates the following layers from outside to inside: LSZH Outer Jacket, Steel Tape Armoring, Binder, Ripcord (2), Water Swellable Tape, Binder, 2.5mm Gel-Free Buffer Tubes containing 250-micron Fibers, and a Dielectric Strength Member.
Mechanical Specifications
Minimum Bend Radius, loaded | 195 mm | 7.677 in |
---|---|
Minimum Bend Radius, unloaded | 130 mm | 5.118 in |
Tensile Load, long term, maximum | 800 N | 179.847 lbf |
Tensile Load, short term, maximum | 2700 N | 606.984 lbf |
Compression | 44 N/mm² | 251.246 lb/in |
Compression Test Method | FOTP-41 | IEC 60794-1 E3 |
Flex | 25 cycles |
Flex Test Method | FOTP-104 | IEC 60794-1 E6 |
Impact | 5 N·m | 44.254 in·lb |
Impact Test Method | FOTP-25 | IEC 60794-1 E4 |
Strain | See long and short term tensile loads |
Strain Test Method | FOTP-33 | IEC 60794-1 E1 |
Twist | 10 cycles |
Twist Test Method | FOTP-85 | IEC 60794-1 E7 |
Vertical Rise, maximum | 461 m | 1,512.467 ft |
Optical Specifications
Fiber Type | G.652.D and G.657.A1 |
---|---|
Cabled Cutoff Wavelength, maximum | 1260 nm |
Point Defects, maximum | 0.05 dB |
Zero Dispersion Slope, maximum | 0.092 ps/[km·nm·nm] |
Zero Dispersion Wavelength, maximum | 1324 nm |
Zero Dispersion Wavelength, minimum | 1300 nm |
Attenuation, maximum | 0.20 dB/km @ 1550 nm | 0.23 dB/km @ 1,625 nm | 0.344 dB/km @ 1310 nm | 0.344 dB/km @ 1380 - 1385 nm |
Dispersion, maximum | 18 ps(nm·km) at 1550 nm | 22 ps(nm·km) at 1625 nm | 3.5 ps(nm·km) from 1285 nm to 1330 nm at 1310 nm |
Index of Refraction | 1.467 @ 1,310 nm | 1.467 @ 1,385 nm | 1.468 @ 1,550 nm |
Mode Field Diameter | 10.1 µm @ 1,550 nm | 9.0 µm @ 1,310 nm |
Mode Field Diameter Tolerance | ±0.2 µm @ 1310 nm | ±0.2 µm @ 1550 nm |
Polarization Mode Dispersion Link Design Value, maximum | 0.05 ps/sqrt(km) |
Standards Compliance | ITU-T G.652.D | ITU-T G.657.A1 |
Environmental Specifications
Installation temperature | -30 °C to +60 °C (-22 °F to +140 °F) |
---|---|
Operating Temperature | -40 °C to +70 °C (-40 °F to +158 °F) |
Storage Temperature | -40 °C to +75 °C (-40 °F to +167 °F) |
Heat Aging, maximum | 0.05 dB/km @ 85 °C |
Temperature Dependence, maximum | 0.05 dB/km |
Temperature Humidity Cycling, maximum | 0.05 dB/km |
Water Immersion, maximum | 0.05 dB/km @ 23 °C |
Environmental Test Specifications
Cable Freeze | -2 °C | 28.4 °F |
---|---|
Cable Freeze Test Method | FOTP-98 | IEC 60794-1 F15 |
Heat Age | -40 °C to +85 °C (-40 °F to +185 °F) |
Heat Age Test Method | IEC 60794-1 F9 |
Low High Bend | -30 °C to +60 °C (-22 °F to +140 °F) |
Low High Bend Test Method | FOTP-37 | IEC 60794-1 E11 |
Temperature Cycle | -40 °C to +70 °C (-40 °F to +158 °F) |
Temperature Cycle Test Method | FOTP-3 | IEC 60794-1 F1 |
Cable Qualification Standards
Cable Qualification Standards | ANSI/ICEA S-104-696 | EN 187105 | Telcordia GR-20 | Telcordia GR-409 |
---|---|
EN50575 CPR Cable EuroClass Fire Performance | Cca |
EN50575 CPR Cable EuroClass Smoke Rating | s1a |
EN50575 CPR Cable EuroClass Droplets Rating | d0 |
EN50575 CPR Cable EuroClass Acidity Rating | a1 |
Environmental Space | Aerial, lashed | Buried | Low Smoke Zero Halogen (LSZH) |
Flame Test Listing | EN 50399 | NEC OFC-ST1 (ETL) and c(ETL) |
Flame Test Method | EN 50399 | IEC 60332-3 | IEC 60754-2 | IEC 61034-2 | IEEE 1202 | UL 1685 |
Jacket UV Resistance | UV stabilized |
Water Penetration | 24 h |
Water Penetration Test Method | FOTP-82 | IEC 60794-1 F5 |
Packaging and Weights
Cable weight | 175 kg/km | 117.595 lb/kft |
---|
Included Products
- CS-8W-200-EMEA 8W-200um: Low Macrobending, Zero Water Peak, Dispersion-Unshifted Singlemode Fiber
Footnotes
Operating Temperature: Specification applicable to non-terminated bulk fiber cable.
Temperature Dependence, maximum: Temperature dependence is conducted at -60 °C to +85 °C (-76 °F to +185 °F).
Temperature Humidity Cycling, maximum: Temperature humidity cycling is conducted at -10 °C to +85 °C (+14 °F to +185 °F) up to 95% relative humidity.