CommScope 810010539/DB | C-096-LA-8W-M12BK/25D/B
Fiber indoor/outdoor cable, Single Jacket/Single Armor, Low Smoke Zero Halogen (LSZH), 96 fiber, Singlemode G.652.D and G.657.A1, Gel-Free, Stranded Loose Tube, Black jacket color, Meter jacket marking, B2ca flame rating.
Corrugated steel tape armor is strong yet flexible, providing additional crush and rodent protection.
Product Classification
Regional Availability: Asia | Australia/New Zealand | EMEA | Europe | Latin America | North America
Portfolio: CommScope®
Product Type: Fiber indoor/outdoor cable
Product Series: Z-LA
General Specifications
Armor Type | Corrugated steel |
Cable Type | Stranded loose tube |
Construction Type | Armored |
Subunit Type | Gel-free |
Jacket Color | Black |
Jacket Marking | Meter |
Subunit, quantity | 8 |
Fibers per Subunit, quantity | 12 |
Total Fiber Count | 96 |
Dimensions
Buffer Tube/Subunit Diameter | 2.5 mm | 0.098 in |
Diameter Over Jacket | 15 mm | 0.591 in |
Representative Image
A visual representation of the CommScope fiber optic cable shows a black outer jacket with a corrugated steel tape armor layer beneath it. Inside, multiple gel-free buffer tubes, each containing several optical fibers, are visible. A dielectric strength member is also present.
Cable Cross-Section Diagram
A cross-section diagram of the cable illustrates its construction: an LSZH outer jacket, steel tape armoring, binder, rip cord (2), water swellable tape, binder, 2.5mm gel-free buffer tubes, 250-micron fibers, and a dielectric strength member.
Mechanical Specifications
Minimum Bend Radius, loaded | 201 mm | 7.913 in |
Minimum Bend Radius, unloaded | 134 mm | 5.276 in |
Tensile Load, long term, maximum | 800 N | 179.847 lbf |
Tensile Load, short term, maximum | 2700 N | 606.984 lbf |
Compression | 44 N/mm | 251.246 lb/in |
Compression Test Method | FOTP-41 | IEC 60794-1 E3 |
Flex | 25 cycles |
Flex Test Method | FOTP-104 | IEC 60794-1 E6 |
Impact | 3 N-m | 26.552 in lb |
Impact Test Method | FOTP-25 | IEC 60794-1 E4 |
Strain | See long and short term tensile loads |
Strain Test Method | FOTP-33 | IEC 60794-1 L1 |
Twist | 10 cycles |
Twist Test Method | FOTP-85 | IEC 60794-1 E7 |
Vertical Rise, maximum | 428 m | 1,404.2 ft |
Optical Specifications
Fiber Type | G.652.D and G.657.A1 |
Environmental Specifications
Installation temperature | -30 °C to +60 °C (-22 °F to +140 °F) |
Operating Temperature | -40 °C to +70 °C (-40 °F to +158 °F) |
Storage Temperature
-40 °C to +75 °C (-40 °F to +167 °F)
Cable Qualification Standards
ANSI/ICEA S-104-696 | EN 187105 | Telcordia GR-20 | Telcordia GR-409
EN50575 CPR Cable Classification
Fire Performance | B2ca |
Smoke Rating | s1b |
Droplets Rating | d0 |
Acidity Rating | a1 |
Environmental Space
Aerial, lashed | Buried | Low Smoke Zero Halogen (LSZH)
Flame Test Information
Flame Test Listing: EN 50399 | NEC OFC-ST1 (ETL) and c(ETL)
Flame Test Method: EN 50399 | IEC 60332-3 | IEC 60754-2 | IEC 61034-2 | IEEE 1202 | UL 1685
Jacket UV Resistance
UV stabilized
Water Penetration
24 h
Water Penetration Test Method: FOTP-82 | IEC 60794-1 F5
Environmental Test Specifications
Cable Freeze | -2°C | 28.4 °F |
Cable Freeze Test Method | FOTP-98 | IEC 60794-1 F15 |
Heat Age | -40 °C to +85 °C (-40 °F to +185 °F) |
Heat Age Test Method | IEC 60794-1 F9 |
Low High Bend | -30 °C to +60 °C (-22 °F to +140 °F) |
Low High Bend Test Method | FOTP-37 | IEC 60794-1 E11 |
Temperature Cycle | -40 °C to +70 °C (-40 °F to +158 °F) |
Temperature Cycle Test Method | FOTP-3 | IEC 60794-1 F1 |
Packaging and Weights
Cable weight | 237 kg/km | 159.257 lb/kft |
Included Products
- CS-8W-200-EMEA 8W-200um: Low Macrobending, Zero Water Peak, Dispersion-Unshifted Singlemode Fiber
Footnotes
Operating Temperature Specification applicable to non-terminated bulk fiber cable.