Microlife MT 410 Digital Antimicrobial Thermometer

Model: MT 410

Description of this Thermometer

This Digital Antimicrobial Medical Thermometer provides highly accurate readings over the human body temperature range. It reduces microbial flora and minimizes the dispersion of contagious microorganisms, providing high safety to the user.

Antimicrobial Copper Properties

Surfaces made or covered by special copper alloys have strong antimicrobial properties against a wide variety of microorganisms*. Copper alloys emit antimicrobial copper ions (Cu+) that, upon contact with microbes and bacteria, rupture their cellular membranes, thus destroying these microorganisms. This activity reduces the microbial flora on the coated area and, due to the «halo phenomenon», simultaneously causes a drastic reduction in pathogens on the remaining body of the thermometer. Thermometers containing parts with antimicrobial copper alloys drastically reduce microbial flora, minimizing the dispersion of contagious microorganisms and thus providing high safety to the end user.

* Efstathiou A. Panos «The Role of Antimicrobial Copper Surfaces in Reducing Healthcare associated Infections», European Infectious Disease, Volume 5, Issue 2, Autumn 2011.

Important Safety Instructions

WARNING: The measurement result given by this device is not a diagnosis! Do not rely on the measurement result only.

Batteries and electronic devices must be disposed of in accordance with the locally applicable regulations, not with domestic waste.

Read the instructions carefully before using this device.

Type BF applied part

Turning on the Thermometer

To turn on the thermometer, press the ON/OFF button 1; a short beep signals «thermometer ON». A display test is performed. All segments should be displayed.

The last measurement reading will be shown on the display 2 automatically for 2 seconds with the «M» icon. Then at an ambient temperature of less than 32 °C, an «L» and a flashing «°C» appear at the display field 2. The thermometer is now ready for use.

Function Test

Correct functioning of the thermometer is tested automatically each time it is turned on. If a malfunction is detected (measurement inaccuracy), this is indicated by «ERR» on the display, and a measurement becomes impossible. In this case, the thermometer must be replaced.

Using the Thermometer

Before use, keep this thermometer out of any physical contact, for at least 2 hours. This utilizes the antimicrobial copper properties, as described in chapter «Antimicrobial Copper Properties». The use of antimicrobial copper is a supplement to and not a substitute for standard infectious control practices; Users must continue to follow all current infection control and cleaning practices. We recommend cleaning the thermometer as described in chapter «Cleaning and Disinfecting». Choose the preferred measuring method. When taking a measurement, the current temperature is continuously displayed and the «°C» symbol flashes. If the beep is heard 10 times and the «°C» is no longer flashing, this means that the measured increase in temperature is less than 0.1 °C in 16 seconds.

To prolong the battery life, turn off the thermometer by briefly pressing the ON/OFF button 1. Otherwise the thermometer will automatically turn off after about 10 minutes.

Storage of Measured Values

If the ON/OFF button 1 is pressed for more than 3 seconds when turning on the thermometer, the automatically stored maximum temperature during the last measurement will be displayed. At the same time, a «M» for memory will appear on the display. About 3 seconds after the button is released, the temperature value disappears and the thermometer is now ready for measurement.

Measuring methods / Normal body temperature

Cleaning and Disinfecting

For disinfection in a home use environment, use a 70% Isopropyl alcohol swab, or a cotton tissue moistened with 70% Isopropyl alcohol to wipe surface pollutants off the thermometer probe (note: consider the application and safety instruction of the disinfectant manufacturer). Always start wiping from the end of the thermometer probe (approx. at the middle of the thermometer) towards the thermometer tip. Afterwards the entire thermometer probe (see number 5 in the drawing) should be immersed in 70% Isopropyl alcohol for at least 5 minutes (max. 24 hours). After immersion, let the disinfectant dry off for 1 minute before next use. Avoid immersing or wiping the display to protect it from fading.

The thermometer is not intended for professional use.

Battery Replacement

When the «» symbol (upside-down triangle) appears in the display, the battery is flat and needs replacing. To replace the battery remove the battery compartment cover 3 from the thermometer. Insert the new battery with the + at the top. Make sure you have a battery of the same type to hand. Batteries can be purchased at any electrical store.

Technical Specifications

This device complies with the requirements of the Medical Device Directive 93/42/EEC.

Technical alterations reserved.

Guarantee

This device is covered by a 5 year guarantee from the date of purchase. During this guarantee period, at Microlife’s discretion, Microlife will repair or replace the defective product free of charge.

Opening or altering the device invalidates the guarantee.

The following items are excluded from the guarantee:

Should guarantee service be required, please contact the dealer from where the product was purchased, or your local Microlife service. You may contact your local Microlife service through our website: www.microlife.com/support

Compensation is limited to the value of the product. The guarantee will be granted if the complete product is returned with the original invoice. Repair or replacement within guarantee does not prolong or renew the guarantee period. The legal claims and rights of consumers are not limited by this guarantee.

Parts Identification

Models: MT 410, Antimicrobial Thermometer

File Info : application/pdf, 2 Pages, 1.97MB

PDF preview unavailable. Download the PDF instead.

ib-mt-410-s-v11-0521

References

Acrobat Elements 9.0.0 (Windows)

Related Documents

Preview Microlife MT 19F1 Digital Thermometer User Manual
Comprehensive instructions for using the Microlife MT 19F1 digital thermometer, including operation, safety precautions, measurement methods, cleaning, and technical specifications. Supports oral, rectal, and axillary temperature readings.
Preview Microlife MT 710 Digital Thermometer User Manual and Specifications
Comprehensive guide to the Microlife MT 710 digital thermometer, covering features, important safety instructions, technical specifications, usage methods, cleaning, and battery replacement.
Preview Microlife MT 800 Digital Thermometer - User Manual
Comprehensive instructions for using the Microlife MT 800 digital thermometer, including safety guidelines, measurement methods (oral, rectal, axillary), cleaning, battery replacement, technical specifications, and warranty information.
Preview Microlife MT 800 Digital Thermometer User Manual and Specifications
Detailed instructions and specifications for the Microlife MT 800 digital thermometer, covering operation, safety, cleaning, battery replacement, and warranty information.
Preview Microlife MT 100 Digital Thermometer: User Manual and Instructions
Comprehensive guide to the Microlife MT 100 digital thermometer, covering safety instructions, measurement methods (oral, rectal, axillary), cleaning, battery replacement, and technical specifications.
Preview Microlife MT 800 Digital Thermometer: User Manual and Specifications
Comprehensive user manual and technical specifications for the Microlife MT 800 digital thermometer. Learn how to use, clean, and maintain your device safely and effectively for accurate temperature readings.
Preview Microlife MT 600 Digital Thermometer: Instructions and Specifications
Comprehensive guide to the Microlife MT 600 digital thermometer, covering features, safety instructions, usage methods (oral, rectal, axillary), cleaning, battery replacement, technical specifications, and warranty information.
Preview Microlife MT 800 Digital Thermometer Instructions for Use
Comprehensive guide for the Microlife MT 800 digital thermometer, covering important safety instructions, operating procedures, measurement methods, cleaning, disinfection, battery replacement, technical specifications, and warranty information.