Microlife MT 800 Digital Thermometer

This document provides important product operation and safety information regarding the Microlife MT 800 digital thermometer. Please read this document thoroughly before using the device and keep for future reference.

Important Safety Instructions

WARNING: The measurement result given by this device is not a diagnosis! Do not rely on the measurement result only.

Batteries and electronic devices must be disposed of in accordance with the locally applicable regulations, not with domestic waste.

Read the instructions carefully before using this device.

Type BF applied part

Turning on the Thermometer

To turn on the thermometer, press the ON/OFF button 1; a short beep signals "thermometer ON". A display test is performed. All segments should be displayed. The last measurement reading will be shown on the display 2 automatically for 2 seconds with the "M" icon. Then at an ambient temperature of less than 32 °C, an "L" and a flashing "C" appear at the display field 2. The thermometer is now ready for use.

Function Test

Correct functioning of the thermometer is tested automatically each time it is turned on. If a malfunction is detected (measurement inaccuracy), this is indicated by "ERR" on the display, and a measurement becomes impossible. In this case, the thermometer must be replaced.

Using the Thermometer

Choose the preferred measuring method. When taking a measurement, the current temperature is continuously displayed and the "C" symbol flashes. If the beep is heard 10 times and the "C" is no longer flashing, the end-temperature has been determined and the thermometer can be read now. 10 short beeps will sound when the temperature is higher than 37.5 °C in order to alert the patient that he/she may have fever. Reference: Oral temperature.

To achieve comparable results allow a 1 minute interval time between measurements.

To prolong the battery life, turn off the thermometer by briefly pressing the ON/OFF button 1. Otherwise the thermometer will automatically turn off after about 10 minutes.

Reviewing the last Measurement

When turning on the thermometer, the last measurement will be displayed with a "M" for memory.

Measuring methods / Normal body temperature

In the armpit (axillary)

Normal range: 34.7 - 37.3 °C

Wipe the underarm with a dry towel. Place the measuring sensor 4 under the arm into the center of the armpit so the tip is touching the skin and position the patient’s arm next to the patient’s body. This ensures that the room air does not affect the reading. Because the axillary takes more time to reach its stable temperature, wait at least 5 minutes, regardless of the beep sound.

In the mouth (oral)

Normal range: 35.5 - 37.5 °C

Do not eat or drink anything hot or cold 10 minutes before the measurement. The mouth should remain closed up to 2 minutes before starting a reading. Position the thermometer in one of the two pockets under the tongue, to the left or right of the root of the tongue. The measuring sensor 4 must be in good contact with the tissue. Close your mouth and breathe evenly through the nose to prevent the measurement from being influenced by inhaled/exhaled air. If this is not possible due to blocked airways, another method for measuring should be used.

Approx. measuring time: 10 seconds!

In the anus (rectal)

Normal range: 36.6 - 38.0 °C

Carefully insert the measuring sensor 4 of the thermometer 2 to 3 cm into the anal aperture. The use of a probe cover and the use of a lubricant is recommended. If you are unsure of this measurement method, you should consult a professional for guidance/training.

Approx. measuring time: 10 seconds!

Cleaning and disinfecting

Before and after each use, clean the thermometer probe 5 with lukewarm soapy water. Wipe dry with a clean soft tissue.

For home use: Disinfect the thermometer probe 5 by wiping the surface with an Isopropyl pad (70%) or use a cotton tissue moistened with Isopropyl (70%). Always start wiping from below the display towards the tip 4. Wipe a second time with a new pad/tissue following the same method.

For professional use: Immerse the thermometer probe 5 in Isopropyl (70%) for at least 5 minutes (max. 24 hours). Let the disinfectant dry off until the thermometer is completely dry. Apply probe covers (available as accessory) in the professional environment.

Important Notes on Cleaning:

Battery Replacement

When the [low battery indicator] symbol (upside-down triangle) appears in the display, the battery is flat and needs replacing. To replace the battery, remove the battery compartment cover 3 from the thermometer. Insert the new battery with the + at the top. Make sure you have a battery of the same type to hand. Batteries can be purchased at any electrical store.

Technical Specifications

FeatureSpecification
TypeMaximum thermometer
Measurement range32.0 °C to 43.9 °C
Temperature < 32.0 °CDisplay "L" (too low)
Temperature > 43.9 °CDisplay "H" (too high)
Measurement accuracy± 0.1 °C; 34 °C - 42 °C
± 0.2 °C; 32.0 - 33.9 °C and 42.1 - 43.9 °C
Operating conditions10 - 40 °C; 15 - 95 % relative maximum humidity
Storage conditions-25 - +60 °C; 15 - 95 % relative maximum humidity
BatteryLR41 (1.5V) / SR41 (1.55V)
Battery lifetimeapprox. 4500 measurements (using a new battery)
IP ClassIP67
Reference to standardsEN 12470-3, clinical thermometers;
ASTM E1112; IEC 60601-1;
IEC 60601-1-2 (EMC); IEC 60601-1-11
Expected service life5 years or 10000 measurements

This device complies with the requirements of the Medical Device Directive 93/42/EEC. Technical alterations reserved.

Guarantee

This device is covered by a 2 year guarantee from the date of purchase. During this guarantee period, at Microlife's discretion, Microlife will repair or replace the defective product free of charge.

Opening or altering the device invalidates the guarantee.

Items excluded from the guarantee:

Should guarantee service be required, please contact the dealer from where the product was purchased, or your local Microlife service. You may contact your local Microlife service through our website: www.microlife.com/support

Compensation is limited to the value of the product. The guarantee will be granted if the complete product is returned with the original invoice. Repair or replacement within guarantee does not prolong or renew the guarantee period. The legal claims and rights of consumers are not limited by this guarantee.

Models: MT 800, MT 800 Thermometer, MT 800, Thermometer

File Info : application/pdf, 2 Pages, 1.84MB

PDF preview unavailable. Download the PDF instead.

IB MT 800 N-V10 3625

References

Adobe PDF Library 15.0

Related Documents

Preview Microlife MT 710 Digital Thermometer User Manual and Specifications
Comprehensive guide to the Microlife MT 710 digital thermometer, covering features, important safety instructions, technical specifications, usage methods, cleaning, and battery replacement.
Preview Microlife MT 800 Digital Thermometer - User Manual
Comprehensive instructions for using the Microlife MT 800 digital thermometer, including safety guidelines, measurement methods (oral, rectal, axillary), cleaning, battery replacement, technical specifications, and warranty information.
Preview Microlife MT 800 Digital Thermometer Instructions for Use
Comprehensive guide for the Microlife MT 800 digital thermometer, covering important safety instructions, operating procedures, measurement methods, cleaning, disinfection, battery replacement, technical specifications, and warranty information.
Preview Microlife MT 19F1 Digital Thermometer User Manual
Comprehensive instructions for using the Microlife MT 19F1 digital thermometer, including operation, safety precautions, measurement methods, cleaning, and technical specifications. Supports oral, rectal, and axillary temperature readings.
Preview Microlife MT 800 Digital Thermometer: User Manual and Specifications
Comprehensive user manual and technical specifications for the Microlife MT 800 digital thermometer. Learn how to use, clean, and maintain your device safely and effectively for accurate temperature readings.
Preview Microlife MT 800 Digital Thermometer User Manual and Instructions
Comprehensive guide for the Microlife MT 800 digital thermometer, covering safety instructions, measurement methods (oral, rectal, axillary), cleaning, battery replacement, and technical specifications.
Preview 8-Second Dishwasher Safe Thermometer MT18L1-PRO - User Manual & Specifications
User manual and technical specifications for the Microlife MT18L1-PRO 8-Second Dishwasher Safe Thermometer. Learn about its features, how to use it, cleaning instructions, warranty information, and technical details.
Preview Microlife MT 100 Digital Thermometer: User Manual and Instructions
Comprehensive guide to the Microlife MT 100 digital thermometer, covering safety instructions, measurement methods (oral, rectal, axillary), cleaning, battery replacement, and technical specifications.